Records from 2010 to 2025. Most recent: inspection, 19 May 2025.
Documentation record
Registered dimensions (L × B × D)60.0 ft × 26.0 ft × 8.0 ft
Registered tonnagegross 104 / net 83
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSISCO MARINE LLC · PANAMA CITY, FL, UNITED STATES · built 2006
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portMEMPHIS, TN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it83 - Simplified, Net Ton
104 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
19 May 2025
TPO Audit
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8156480
15 November 2023
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7825487
15 November 2023
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7825803
20 September 2023
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7795277
20 September 2023
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7810842
9 May 2023
COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7684858
17 October 2022
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7579040
23 February 2022
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7400916
1 October 2021
Administrative Inspection · Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7325067
1 October 2021
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7325163
26 January 2021
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7150547
7 January 2021
TPO Audit
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7135196
22 November 2019
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6868813
3 April 2019
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6656003
2 January 2019
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6604896
2 January 2019
Administrative Inspection · Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6604899
6 October 2018
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6557421
15 August 2018
Initial Certification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6513179
12 April 2018
MTSA Verification · Industry Initiated Exam · Administration
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6390556
20 September 2017
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6270894
4 August 2016
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6042272
2 August 2015
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5231315
15 April 2015
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5138183
13 February 2015
Industry Initiated Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5070756
25 October 2012
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4472338
8 December 2010
DAPI Audit · Industry Initiated Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3907664
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 November 2023
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: (1) Be maintained to ensure proper operation.
The LARRY BARBER's port main diesel engine overheated and seized. Make repairs to the satisfaction of the TPO. Provide objective evidence of the repairs to the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 November 2023
Resolved 30 November 2023
Resolution: Received objective evidence of satisfactory repairs from the TPO.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 May 2023
Resolved
Fuel shutoff requirements.
(b) To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. (d) The valve must be operable from a safe place outside the space where the valve is installed.
Remote fuel shut off valve was found to be seized and inoperable.
Make repairs to remote fuel shut off valve to provide proper operation.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 May 2023
Resolution: Cleared by TVIB
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 23 May 2023
Resolved
Machinery space fire prevention.
(b) Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components.
Port Main Engine turbocharger missing exhaust lagging.
Renew exhaust lagging to properly insulate.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 May 2023
Resolution: Cleared by TVIB
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2023
Resolved
General.
(a) Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Electrical cable bundle from main distribution panel in aft engine room has a 1 ft. section of outer jacketing that shows signs of burning/overheating.
Determine/investigate source of burning/overheating and affect repairs to ensure safe operation of electrical system.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 May 2023
Resolution: Cleared by TVIB
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 May 2023
Resolved
Fire pumps, fire mains, and fire hoses.
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d) of this section; or a portable pump, and hoses and nozzles, in accordance with paragraphs (e) and (f) of this section.
Suction hose for portable fire pump has a tear through the side of the hose.
Renew suction hose for portable fire pump.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 May 2023
Resolution: Cleared by TVIB
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 October 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The starboard generator had a fire.
Please work with your TPO (TVIB) to clear the deficiency IAW CG-CVC Policy Letter 17-10 prior to vessel movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 October 2021
Resolution: Received satisfactory tech report and causal analysis from TPO (TVIB).
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 2 January 2019
Resolved
Forward fuel tank suffered a fuel leak into the bow void.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 January 2019
Resolved 21 January 2019
Resolution: Permanent repairs were made to the fuel tank.
4 August 2016Routine · role: Involved in a Marine Casualty · activity 6042272
20 September 2017Routine · role: Involved in a Marine Casualty · activity 6270894
6 October 2018Routine · role: Transiting Vicinity of Primary Subject · activity 6557421
2 January 2019Routine · role: Involved in a Marine Casualty · activity 6604896
3 April 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6656003
1 October 2021Routine · role: Involved in a Marine Casualty · activity 7325163
17 October 2022Routine · role: Involved in a Marine Casualty · activity 7579040
20 September 2023Routine · role: Subject to Marine Inspection · activity 7810842
15 November 2023Routine · role: Involved in a Marine Casualty · activity 7825803
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source:
IIR, through 2026.