Records from 1982 to 2011. Most recent: inspection, 18 February 2011.
Inspection history · 37
18 February 2011
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3948050
10 July 2008
Annual Inspection · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3276699
3 December 2007
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3108559
30 April 2007
COI Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2920558
24 October 2006
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2807554
26 June 2006
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2691942
21 June 2006
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2687200
14 June 2006
Annual Inspection · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2679883
4 October 2005
Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2508370
3 October 2005
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2507826
25 August 2005
Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2474455
19 January 2005
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2277792
13 August 2004
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2181131
29 July 2004
Periodic Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2149135
27 July 2004
Hull Examination · Internal Structural Exam
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2146970
1 June 2004
Drydock Extension
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2085981
7 October 2003
Administrative Inspection
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1922859
3 June 2003
Periodic Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1809545
3 August 2001
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1075041
13 July 2001
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1067685
12 June 2001
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1468223
2 June 2000
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1418718
28 June 1999
Administrative
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1078586
4 June 1999
COI Inspection · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1449189
27 July 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1470952
22 April 1997
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428748
4 August 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1089088
31 August 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355446
23 July 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 879600
7 March 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 858561
25 March 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414273
17 August 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 843025
30 June 1993
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436777
11 May 1992
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 952462
4 April 1991
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911816
12 March 1986
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1020274
12 March 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965073
Personnel › Training › First Aid/CPR
Issued 10 July 2008
Resolved
Provide Red Cross First-Aid/CPR card for a minimum of 50% of vessel crew IAW NVIC 1-91.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 12 July 2008
Resolution: Rcvd faxed confirmation of training.
Fire Fighting › Fire Bucket › Availability
Issued 30 April 2007
Resolved
Add one fire bucket to the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2007
Resolved 28 June 2007
Resolution: buckets onboard
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 14 June 2006
Resolved
Provide crewmam who is CPR certified
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2006
Personnel › Manning/Qualifications › First Aid Certified Personnel
Issued 14 June 2006
Resolved
provide crewman first aid qualified
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 June 2006
Resolved
demonstrate operation of stern light
Due 28 June 2006
Resolved 26 June 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 June 2006
Resolved
replace line on light float
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2006
Engineering › Bilge Water Management System › Pump
Issued 14 June 2006
Resolved
demonstrate operation of bilge pump
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 June 2006
Resolved
cap off all dead end wires in engine room compartment and forward compartment at operators station
Due 28 June 2006
Resolved 26 June 2006
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 14 June 2006
Resolved
install insulation on port MDE exhaust
Due 28 June 2006
Resolved 26 June 2006
Engineering › Fuel Oil Service System › Valve
Issued 14 June 2006
Resolved
replace fuel shut off valve in MDE compartment
Due 28 June 2006
Resolved 19 June 2006
Resolution: INstalled new valve handle
Construction/Loadline › Hull › Hull Plating
Issued 4 October 2005
Resolved
1. Prior to carrying passengers make temporary repairs to starboard gunwale and deck in way of
way mid-ship
2. Make permanent repairs to gunwale and deck in way of mid-ship after permanent repairs are completed on P/V LELA
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 August 2005
Resolved
Engineroom bilge alarm not producing audible and visual alarm in cabin.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 September 2005
Resolved 8 September 2005
Resolution: Replaced bilge alarm; alarms satisfactory in cabin.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 29 July 2004
Resolved
Provide and post an Emergency Instructions list in accordance with 46 CFR 185.510.
Condition: Unknown
Due 25 August 2004
Resolved 30 July 2004
Resolution: Observed and posted.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 July 2004
Resolved
Prior to operating at night or in reduced visibility, prove the proper operation of the vessel's neavigation lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 July 2004
Resolution: Tested sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 July 2004
Resolved
Provide on board a first aid kit in accordance with 46 CFR 184.710 or provide your own first aid kit supplied in accordance with 46 CFR 160.410.
Condition: Improper/Lack of Maintenance
Due 5 August 2004
Resolved 14 June 2006
Engineering › Bilge Water Management System › Pump
Issued 29 July 2004
Resolved
Prove the proper operatin of the vessel's bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2004
Resolution: Tested sat.
Stability › Weathertight Integrity › General
Issued 27 July 2004
Resolved
CG 835 issued to require operator to renew gaskets for engine room access doors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 13 August 2004
Resolution: Gaskets renewed, inspected satisfactorly.
Construction/Loadline
Issued 12 June 2001
Resolved
Make proper permanent repairs IWO hole in main deck approx 2ft aft of port engine (under wood decking).
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Fire Fighting
Issued 12 June 2001
Resolved
Properly mount fire extinguisher in engineroom and aft main cabin.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Documentation
Issued 12 June 2001
Resolved
Post stability letter.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Engineering
Issued 12 June 2001
Resolved
Make proper permanent repairs IWO crack at port engine mount #4 outboard gusset.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Lifesaving
Issued 12 June 2001
Resolved
Properly mark ring buoy with vessel name and hailing port.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Engineering
Issued 12 June 2001
Resolved
Label emergency fuel shutoff valve.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Construction/Loadline
Issued 12 June 2001
Resolved
Make proper permanent repairs IWO cracks in port side longitudinal frames #1,2,3,4 aft of forward engineroom bulkhead and #4 starboard side longitudinal aft of forward engineroom bulkhead.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Lifesaving
Issued 12 June 2001
Resolved
Post lifejacket donning and use instructions in a conspicuous location.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Lifesaving
Issued 12 June 2001
Resolved
Mount at operating station, emergency instructions as per 46 CFR 185.510.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Engineering
Issued 12 June 2001
Resolved
Make proper permanent repairs IWO cracks at stbd engine mount #3,4 inboard gussets and #4 outboard gusset.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Navigation
Issued 4 June 1999
Resolved
REPAIR RADAR TO FUNCTION PROPERLY, SWEEP STICKING AND INTERMITENT.
Condition: Unknown
Due 28 June 1999
Resolved 14 June 1999
Construction/Loadline
Issued 4 June 1999
Resolved
INSTALL BILGE ALARM SYSTEM PER NEW REQUIREMENT.
Condition: Unknown
Due 28 June 1999
Resolved 14 June 1999
Engineering
Issued 4 June 1999
Resolved
REPLACE WASTED STUFFING BOX LOCKS ON PORT AND STBD SHAFTS.
Condition: Unknown
Due 28 June 1999
Resolved 14 June 1999
Construction/Loadline
Issued 4 June 1999
Resolved
INSTALL WATERPROOF SEALS IN ENG RM THROUGH BULKHEAD TO PAX COMPARTMENT IN WAY OF HOSE PENETRATIONS.
Condition: Unknown
Due 28 June 1999
Resolved 14 June 1999
Lifesaving
Issued 22 April 1997
Resolved
REGISTER THE NEWLY INSTALLED 406 MHZ CLASS I EPIRB RADIO BEACON WITH NOAA_x001C_ AS REQUIRED BY 47 CFR SUBPART 80.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Documentation
Issued 22 April 1997
Resolved
OBTAIN AND PLACE ON BOARD A VALID F.C.C. RADIO TELEPHONY SAFETY CERTIFICATE.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 31 August 1995
Resolved
REPLACE HATCH SEAT/COAMING DUE TO CRACKING.
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995