Records from 1998 to 2024. Most recent: inspection, 6 August 2024.
Documentation record
Registered dimensions (L × B × D)66.1 ft × 20.1 ft × 6.7 ft
Registered tonnagegross 104 / net 71
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBRYANT BOATS INC · BAYOU LA BATRE, AL, UNITED STATES · built 1956
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMEMPHIS, TN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it104 - Regulatory (Subpart C or D), Gross Ton
71 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 28
6 August 2024
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7977297
29 June 2022
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7491565
14 April 2022
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7431620
21 March 2022
Initial Certification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7416600
17 September 2021
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7316675
24 May 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7205682
4 January 2018
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6332382
4 October 2017
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6295495
24 April 2015
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5111528
6 December 2012
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4498050
6 June 2012
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4335729
16 May 2012
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4317562
2 April 2012
DAPI Audit
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4277362
29 March 2012
Administration
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4274787
29 March 2012
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4274824
23 January 2012
Administration
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4230236
23 January 2012
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4230253
25 September 2009
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3617778
8 January 2009
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3391004
7 January 2009
Administration
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3390412
27 October 2006
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2809307
13 September 2006
MTSA Verification · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2781017
26 June 2006
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2692270
3 October 2005
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2507826
24 May 2005
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2366636
19 May 2005
Administrative Inspection
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2362530
11 January 2005
Type not recorded
No type recorded · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2274838
8 January 1998
Type not recorded
No type recorded · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 412021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 March 2022
Resolved
Each towing vsl must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. None of the alarms required by 46CFR143.230 are currently operational due to the replacement of the alarm panel. The vessel must staff a second deckhand to act as an engine room watch while the vessel is in operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2022
Resolved 29 June 2022
Resolution: Vessel POC provided SLMR with written and video evidence that the alarms required by 46 CFR 143.230 are installed and working as required.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 March 2022
Resolved
The design of the fire detection system and its installation must be certified by a registered professional engineer with experience in fire detection system design, a NICET Level IV fire alarm engineering tech, or by an authorized class society with equivalent experience. A new fire detection system has been installed onboard the vessel and has not been certified as per 46CFR142.330(a)(7).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2022
Resolved 8 April 2022
Resolution: SEC LMR recd a copy of the PE Letter issued to the vessel on 08APR2022.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 May 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 August 2021
Resolved 20 September 2021
Resolution: Vessel O/O requested vessel be put in laid up status. SEC LMR completed documentation of laid up status IAW with 17SEP2021.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 13 September 2006
Resolved
Place plug in intrinsically safe outlet box for fuel transfer pump in engine room.
Action required: 705 - Other - as specified
Due 13 October 2006
Resolved 27 October 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 September 2006
Resolved
Place cover on battery box in engine room.
Action required: 705 - Other - as specified
Due 13 October 2006
Resolved 27 October 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 13 September 2006
Resolved
Replace light covers on lights in engine room.
Action required: 705 - Other - as specified
Due 13 October 2006
Resolved 27 October 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 13 September 2006
Resolved
Replace batteries for emergency lighting in engine room.
Action required: 705 - Other - as specified
Due 13 October 2006
Resolved 27 October 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 September 2006
Resolved
Resecure emergency lighting above port generator in engine room.
Action required: 705 - Other - as specified
Due 13 October 2006
Resolved 27 October 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 13 September 2006
Resolved
Place BV extinguisher at engine room door on the inside or outside of engine room at the door.
Action required: 705 - Other - as specified
Due 13 October 2006
Resolved 27 October 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 13 September 2006
Resolved
Replace covers on all turbo air intakes for all diesel engines.
Action required: 705 - Other - as specified
Due 13 October 2006
Resolved 27 October 2006
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 13 September 2006
Resolved
Make smoke detector operable in washroom or remove.
Action required: 705 - Other - as specified
Due 13 October 2006
Resolved 27 October 2006
Construction/Loadline › Hull › Hull Plating
Issued 13 September 2006
Resolved
Repair cracks on stbd gunwale and stern box.
Action required: 705 - Other - as specified
Due 13 October 2006
Resolved 27 October 2006
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 13 September 2006
Resolved
Cover stern voids to avoid water ingress.
Action required: 705 - Other - as specified
Due 13 October 2006
Resolved 27 October 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 September 2006
Resolved
Mark all life rings with vessel name.
Action required: 705 - Other - as specified
Due 13 October 2006
Resolved 27 October 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 September 2006
Resolved
Make up one life ring with buoy light.
Action required: 705 - Other - as specified
Due 13 October 2006
Resolved 27 October 2006