Records from 1993 to 2009. Most recent: inspection, 24 January 2009.
Inspection history · 56
24 January 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3399364
23 November 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3367892
17 September 2008
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3326832
25 January 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3136273
12 January 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3131251
21 October 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3085688
10 September 2007
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3054141
1 September 2006
COC-MODU Renew · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2761952
16 November 2005
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2535840
17 September 2004
COC-MODU Renew
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2198089
17 October 2003
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1930742
21 April 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1777763
20 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1760092
27 September 2002
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1690791
3 September 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1670115
29 August 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1913833
17 November 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1076147
6 November 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1076218
2 October 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417394
26 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073162
12 January 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 769233
2 October 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1054894
27 September 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 822452
30 August 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 771915
23 August 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 203008
22 August 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 203009
14 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1053171
7 May 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 694910
9 February 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 721647
25 January 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 57932
12 November 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 806507
6 October 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468535
5 July 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1420
2 February 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1125543
4 January 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 813739
6 October 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375511
22 May 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1126251
19 February 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778338
11 November 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785466
29 September 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1115137
25 September 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435990
12 March 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 133461
29 October 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 762106
1 October 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 193512
27 September 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380650
5 August 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 29705
2 January 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 754886
21 December 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 203007
4 December 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 203010
4 December 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 753856
4 December 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 754101
1 December 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 203006
18 May 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458160
25 January 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 855138
1 June 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 159087
20 May 1993
Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 848781
Construction/Loadline › Structures › Machinery Space Opening
Issued 17 September 2008
Resolved
Make approved repairs to Muti-Cable transits in bulkhead at SCR room and stairway at CSC-4.
Action required: 705 - Other - as specified
Due 1 November 2008
Resolved 10 October 2008
Resolution: 10/20/08 Received email and photos from [name withheld] and consulted with ABS, who looked at the Muti-Cable transit repair. Cleared 835.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 1 September 2006
Resolved
Identify/repair grounds on 440 bus panel to the satisfaction of class society.
Action required: 705 - Other - as specified
Due 7 September 2006
Resolved 5 September 2006
Resolution: Identified (#2 A/C Fan Motor for generator room) and repaired ground to the satisfaction of the attending ABS surveyor. Documentation submitted.
Electrical › Electric Generation Source (emergency) › Generator
Issued 1 September 2006
Resolved
Demonstrate proper operation of emergency generator to the satisfaction of attending class society.
Action required: 705 - Other - as specified
Due 7 September 2006
Resolved 5 September 2006
Resolution: Proper operation of emergency generator demonstrated to the attending ABS surveyor. Documentation submitted.
Fire Fighting › Fire Main › Condition
Issued 1 September 2006
Resolved
Verify integrity of fire main to the satisfaction of attending class society.
Action required: 705 - Other - as specified
Due 7 September 2006
Resolved 5 September 2006
Resolution: Hydrostatic test of fire main verified integrity to attending ABS surveyor. Documentation submitted.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 1 September 2006
Resolved
Repair air bottles in lifeboats #1 and #3 to the satisfaction of the attending class society.
Action required: 705 - Other - as specified
Due 7 September 2006
Resolved 5 September 2006
Resolution: Air bottles were repaired and documentation submitted from attending ABS surveyor.
Electrical › Electric Generation Source (emergency) › Circuit Breaker
Issued 15 November 2005
Resolved
Prove operation of emergency generator auto bus transfer.
Due 21 November 2005
Resolved 22 November 2005
Resolution: ABS witnessed proper operation of auto bus transfer.
Construction/Loadline
Issued 2 October 2001
Resolved
crop and renew wasted angles under paint locker deck.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Lifesaving
Issued 2 October 2001
Resolved
Repair/replace leaking hydraulic accumulator pump.
Condition: Unknown
Due 2 October 2001
Resolved 18 October 2001
Lifesaving
Issued 2 October 2001
Resolved
Replace exhaust insulation with proper insulation per manuf. specs.
Condition: Unknown
Due 10 October 2001
Resolved 18 October 2001
Unknown
Issued 6 October 1999
Resolved
Conduct and log satisfactory test of total rig emergency shut-down.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Unknown
Issued 6 October 1999
Resolved
Complete requirements issued by ABS surveyor's report dated September 19, 1999.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Lifesaving
Issued 6 October 1999
Resolved
Install emergency lights that illuminate lifeboats when in the water at allstations.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Lifesaving
Issued 6 October 1998
Resolved
REPAIR EMERGENCY ESCAPE LADDERS ON COLUMN EXTERIORS WHERE DAMAGED.
Condition: Unknown
Due 7 October 1998
Resolved 13 October 1998
Lifesaving
Issued 6 October 1998
Resolved
PROVIDE CLASSIFICATION AND U.S.C.G. ACCEPTANCE ON FRP GRATING IN MACHINERY SPACE. SUBMIT APPROVAL TO [name withheld].
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Lifesaving
Issued 6 October 1998
Resolved
RE-WRAP LIFEBOAT #1 WIRE FALL (INBOARD WINCH) WHERE WIRE HAS JUMPED LAY. IFDAMAGED, REPLACE TO SATISFACTION OF ATTENDING CLASS SURVEYOR OR U.S.C.G. INSPECTOR.
Condition: Unknown
Due 7 October 1998
Resolved 13 October 1998
Fire Fighting
Issued 6 October 1998
Resolved
REPAIR OR REPLACE MOTOR CONTROLLER SWITCH TO NUMBER ONE FIRE PUMP IN MACHINERY SPACE.
Condition: Unknown
Due 7 October 1998
Resolved 13 October 1998
Documentation
Issued 6 October 1998
Resolved
PROVIDE SAFE MANNING CERTIFICATE WITH NAME CHANGE FROM FLAG ADMINISTRATION.SUBMIT COPY TO [name withheld].
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Lifesaving
Issued 6 October 1998
Resolved
CONDUCT OPERATIONAL TEST OF LIFEBOAT RELEASE GEAR UNDER A LOAD OF 1.1 TIMESTHE TOTAL MASS OF THE BOAT WHEN LOADED WITH ITS FULL COMPLEMENT OF EQUIPMENT AND CAPACITY. ALTERNATIVE TESTING MAY BE SUBMITTED TO [name withheld].
Condition: Unknown
Due 8 October 1998
Resolved 8 October 1998
Lifesaving
Issued 6 October 1998
Resolved
REPAIR WATER LEAK IN HEAT EXCHANGER LINE TO DRAWWORKS BRAKE.
Condition: Unknown
Due 7 October 1998
Resolved 13 October 1998
Electrical
Issued 25 September 1997
Resolved
REPAIR AND TEST SAFETY SHUTDOWNS ON GENERATOR NO. 5.
Condition: Unknown
Due 25 September 1997
Resolved 25 September 1997
Lifesaving
Issued 25 September 1997
Resolved
CONDUCT 10% OVERLOAD WEIGHT TEST OF LIFEBOAT NO. 3 FALLS.
Condition: Unknown
Due 25 September 1997
Resolved 25 September 1997
Electrical
Issued 25 September 1997
Resolved
LOCATE AND REPAIR ELECTRICAL GROUND ON NO. 1 SECONDARY SYSTEM.
Condition: Unknown
Due 25 September 1997
Resolved 25 September 1997
Electrical
Issued 25 September 1997
Resolved
REPLACE PLASTIC WIRE TIES WITH APPROPRIATE METAL BANDINGS IN SHALE SHAKER AREA.
Condition: Unknown
Due 25 September 1997
Resolved 25 September 1997
Fire Fighting
Issued 25 September 1997
Resolved
PLACE AN A-CLASS DOOR IN GALLEY ENTRANCE. MAKE GALLEY DOORS SELF-CLOSING AND CAPABLE OF LATCHING.
Condition: Unknown
Due 25 September 1997
Resolved 25 September 1997
Construction/Loadline
Issued 27 September 1996
Resolved
REPAIR/COMPLETE INSTALLATION OF OILY WATER SEPARATOR .
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Electrical
Issued 27 September 1996
Resolved
ISOLATE AND REPAIR GROUND INDICATED ON SECONDARY GROUND DETECTION IN SCR ROOM.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Documentation
Issued 27 September 1996
Resolved
PROVIDE APPROVED EMERGENCY EVACUATION PLAN.,
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Electrical
Issued 27 September 1996
Resolved
SECURE FERRULE THROUGH BOX GIRDER IN NEW MUD PIT ROOM AND FERRULE IN STBD. BULKHEAD OF OLD MUD PIT ROOM PRIOR TO OPERATION.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Engineering
Issued 27 September 1996
Resolved
INSTALL A FUELING HOSE/DEADMAN NOZZLE AND FOUR LB. DRY CHEM. FIRE EXT. AT FORKLIFT REFUELING AREA.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Fire Fighting
Issued 27 September 1996
Resolved
OIM SUBMIT TRAINING PLAN FOR NEXT TWO MONTHS TO OCMI. AT END OF PERIOD SUBMIT COPIES OF LOGS VERIFYING ADHERANCE TO PLAN.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Fire Fighting
Issued 27 September 1996
Resolved
INSTALL FIXED CO2 SYSTEM IN PAINT LOCKER PRIOR TO STOWAGE OF PAINT AND SOLVENTS. UPDATE HAZARDOUS AREAS PLAN TO REFLECT ADDITION OF PAINT LOCKER. SUBMIT REVISED PLAN TO OCMI.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Electrical
Issued 27 September 1996
Resolved
REPLACE ALL PLASTIC WIRE TIES WITH METAL STRAPS ON DRILL FLOOR AS NEC. INSTALL PANEL IN DIST. BOX, INSTALL BLANK IN DIST. BOX, REMOVE UNUSED WIRES, AND PROPERLY STRAP ALL WIRING IN DRILL FLOOR ELEC. ROOM. SECURE BOP CONTROL PANEL, DRILL FLOOR.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Lifesaving
Issued 27 September 1996
Resolved
REPAIR LIMIT SWITCH FOR L/B #1 AND MAKE PERMANENT REPAIRS TO CRACK IN FIBERGLASS DECK.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Electrical
Issued 18 May 1994
Resolved
REPAIR AS NECESSARY, PROVE PROPER OPERATION OF LIFEBOAT EMBARKATION LIGHTING ON EMERGENCY CIRCUIT.
Condition: Unknown
Due 27 May 1994
Resolved 27 May 1994
Electrical
Issued 18 May 1994
Resolved
REPAIR GROUND FAULT IN 120V CIRCUIT.
Condition: Unknown
Due 27 May 1994
Resolved 27 May 1994
Lifesaving
Issued 18 May 1994
Resolved
PROVIDE DOCUMENTATION OF APPROVAL FOR ROCKET TYPE LINE THROWING DEVICES.
Condition: Unknown
Due 27 May 1994
Resolved 27 May 1994
Electrical
Issued 18 May 1994
Resolved
INSTALL PERMANENT LIGHT ON EMERGENCY CIRCUIT IN BALLAST CONTROL ROOM.
Condition: Unknown
Due 27 May 1994
Resolved 27 May 1994