Records from 2007 to 2026. Most recent: inspection, 26 February 2026.
Inspection history · 26
26 February 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8320673
25 July 2025
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8194365
28 April 2025
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8102813
28 January 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8069596
13 May 2024
Examination of Repairs · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7912657
31 July 2023
Examination of Repairs · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7757704
5 May 2023
Damage Survey · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7685456
24 January 2023
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7635024
10 January 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7619606
6 December 2022
Deficiency Check · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7605069
7 October 2022
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7573487
14 June 2022
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7477375
2 March 2022
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7404722
3 November 2021
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7344805
15 July 2021
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7256674
5 April 2021
Plan Review "T" Boat · Examination of Repairs · In-Service Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7169902
26 January 2021
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7130877
10 July 2020
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7002890
13 June 2019
Administrative Inspection · Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6712866
18 January 2019
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6611586
17 May 2018
Internal Structural Exam · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6571072
21 September 2017
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294387
26 May 2017
Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 6156372
26 May 2017
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6566794
13 February 2017
Administrative Inspection · COI Inspection · Internal Structural Exam · DAPI Audit · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6126328
2 June 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5882141
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 February 2026
Resolved
01 Fire bucket is missing a lanyard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 February 2026
Resolved
Water tight container holding flares needs to be mark as "DISTRESS SIGNALS'
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 February 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2024
Resolved
Both port and starboard bilge pumps would not work. Must make repairs and test to the satisfaction of attending CG Marine inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 May 2024
Resolved
Vessel is required to have 3 fire buckets. Vessel was found with only 2 and one of those had a missing lanyard. Must replace missing fire bucket and make sure all 3 have proper size lanyards prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2024
Resolved
13 life jackets were found in non serviceable condition. Must replace 13 adult life jackets and label with vessel's name. Passenger count is reduced my 13 until cleared by attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 14 May 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2024
Resolved
Anchor light was not working. Must make repairs and test to the satisfaction of attending CG Marine Inspector. Vessel is limited to daylight hours only.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 14 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2024
Resolved
Starboard side emergency fuel shut off valve is not working properly and the fitting from valve to tank is loose. Must make repairs to the satisfaction of attending CG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 May 2023
Resolved
Must conduct satisfactory sea trials after repower prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 24 January 2023
Resolved
Both life floats are faded/worn/paint cracking exposing the foam. Must conduct repairs or replace both life floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 9 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 January 2023
Resolved
3 Adult life jackets were found unusable and must be replaced. Total passenger count reduced by 3 until replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 9 February 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 January 2023
Resolved
First aid kit had expired aspirin. Must replace aspirin.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 9 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 January 2023
Resolved
Both life rings on the bow have dry-rotted grab lines. Must replace grab lines or replace both life rings.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 9 February 2023
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 6 December 2022
Resolved
Master does not possess MROP.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2022
Resolved 8 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 December 2022
Resolved
08 out 12 flares found expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2022
Resolved 6 December 2022
Resolution: 08 flares purchased, and within service dates. 08 expired flares removed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 December 2022
Resolved
02 out of 03 floatlights found non-operational. Depleted batteries. Vessel operations restricted to daylight hours.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2022
Resolved 15 December 2022
Resolution: 02 new floatlights purchased, replaced 02 non-functional floatlights.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 6 December 2022
Resolved
EPIRB NOAA registration found expired. Renew registration.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2022
Resolved 6 December 2022
Resolution: Owner provided NOAA documentation of renewed EPIRB registration.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 December 2022
Resolved
01 fire buckets out of 03 missing. Replace with new labelled bucket.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2022
Resolved 6 December 2022
Resolution: Labelled fire bucket with lanyard replaced. 03 fire buckets accounted for.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 March 2022
Resolved
1 adult life jacket was torn and un usable. Must replace 1 adult life jacket. Total passenger count reduced by 1.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2022
Resolved 22 April 2022
Resolution: New life jacket onboard and labeled with vessels name.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 July 2021
Resolved
Both life floats had excess cracking. Must make repairs to the satisfaction of attending CG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2021
Resolved 23 July 2021
Resolution: Operator submitted photographic imagery of repairs conducted on the lifefloats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 July 2021
Resolved
Life ring buoy retro was faded and worn. Replace all retro tape with SOLAS retro
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2021
Resolved 23 July 2021
Resolution: Operator submitted photographic imagery of newly applied retroflective SOLAS tape on lifering buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 July 2021
Resolved
Life ring floating light lanyard was dry rotted. Replace line with CG approved 3-6 foot line floating line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2021
Resolved 23 July 2021
Resolution: Operator submitted photographic imagery of newly replaced floatlight lanyard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 July 2021
Resolved
Vessel does not have a CG approved NAV chart onboard. GPS latest software installed is version 7.0. Must update GPS to lastest softward (13.4) or have a CG approved paper NAV chart onboard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2021
Resolved 23 July 2021
Resolution: Operator submitted photographic imagery of updates uploaded to the GARMIN ECHOMAP Plus 74cv. Current software is version 7.00.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 July 2021
Resolved
First aid kit had expired/missing items. Must update kit to meet requirements of 46 CFR 160.041.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2021
Resolved 31 August 2021
Resolution: Sent email with pictures showing the missing items ordered and onboard vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 January 2021
Resolved
Collision bulkhead has a approx 2 inch hole drilled to allow wiring to pass through from manufacture and is not water tight. Add fire retardant sealant to make watertight.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2021
Resolved 5 February 2021
Resolution: Recieved picture of hole filled with sealant.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 July 2020
Resolved
One life float buoyant apparatus condemned do to condition, one life float needs repairs or replaced prior to carrying passengers. 46 CFR 180.202
11 July update. One new lifefloat replaced. 30 days to repair other lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2020
Resolved 26 August 2020
Resolution: Replaced one life float, and conducted repairs/paint other life float
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 July 2020
Resolved
Both weak links for life floats were for 21 or more persons and each life float was for 15 persons each. Either replace both weak links for correct size or tie both painters to one weak link prior to carrying passengers. 46 CFR 180.130
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2020
Resolved 11 July 2020
Resolution: Tied both lifefloat painters to one weak link
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 July 2020
Resolved
1 life float paddle missing and other 3 where dry rotted and splitting apart. Replace all paddles with new in accordance with 46 CFR 180.175 prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2020
Resolved 11 July 2020
Resolution: Bought 4 new paddles.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 July 2020
Resolved
Light list and Coast Pilot were 2018. Update all NAV pubs and charts with current edition. 46 CFR 184.420
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2020
Resolved 26 August 2020
Resolution: Printed out current edition of Light list and down loaded Coast Pilot
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 July 2020
Resolved
1 adult life jacket was found deteriorated. Reduce passenger count by 1 until life jacket is replaced with new.
46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2020
Resolved 26 August 2020
Resolution: Replaced life jacket with new type 1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2020
Resolved
2 of the 4 12V batteries were not secured. Secured the two batteries to prevent from moving around while underway. 46 CFR 183.350
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2020
Resolved 30 July 2020
Resolution: Installed all battery hold down clamps on all 4 12V batteries. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 July 2020
Resolved
One of the life floats floating lights was not working. Conduct repairs or replace life float light prior to operations at night. 46 CFR 180.175
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2020
Resolved 15 July 2020
Resolution: replaced battery, sent video of both lights side by side flashing.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 13 June 2019
Resolved
Vessel must carry 6 day and 6 night, or 12 day/night distress signals onboard. The vessel had only 4 day/night and 1 day distress signal on board Bilge high level alarms are inoperable. Repair/replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2019
Resolution: The proper amount of flares were purchased, placed on the vessel, and a photo was sent clearing the deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 June 2019
Resolved
FCC Safety Certificate is expired. Provide an updated certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2019
Resolution: FCC Safety Certificate was renewed and verified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2019
Resolved
Provide new post-accident alcohol tests.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2019
Resolution: New post-accident alcohol test devices were provided and verified.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 June 2019
Resolved
Update tide tables, Light List, and Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2019
Resolution: Tide tables, light list, and coast pilot was printed and stored on the vessel. Validated by photo to clear the deficiency.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 June 2019
Resolved
Link VHF radio to GPS, or renew radio to provide GPS position.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2019
Resolution: A new VHF radio with integrated GPS and MMSI# was purchased, and MMSI# was verified installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 June 2019
Resolved
Bilge pump must send a signal to operating station to show automatic operations light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2019
Resolution: Visual alarm for automatic bilge pump is in proper working order.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2018
Resolved
Both life floats need new painter line. Renew per manufactures specs.
Action required: 10 - Deficiency Rectified
Resolved 4 June 2018
Resolution: New line was installed, including new weak links.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 May 2018
Resolved
EPIRB has been installed in a position that will not allow it to float free and self deploy. Reposition so that it will float free.
Action required: 10 - Deficiency Rectified
Resolved 4 June 2018
Resolution: EPIRB was moved to a new location and will float free.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2018
Resolved
Life ring line is wasted and must be renewed.
Action required: 10 - Deficiency Rectified
Resolved 4 June 2018
Resolution: New line was provided.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 17 May 2018
Resolved
Emergency broadcast placard is missing. Provide and post.
Action required: 10 - Deficiency Rectified
Resolved 4 June 2018
Resolution: Placard was provided and posted near the radio.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 May 2018
Resolved
Alcohol swabs are expired. provide new swabs or other approved means of testing for alcohol.
Action required: 10 - Deficiency Rectified
Resolved 4 June 2018
Resolution: New DOT approved alcohol swabs were provided.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 April 2017
Resolved
Vessel had 42 adult and 3 child PFD that are not serviceable. Vessel is restricted to 15 passengers until new PFD are supplied and marked.
Action required: 705 - Other - as specified
Resolved 19 April 2017
Resolution: 42 new adult PFD, and 3 new Child PFD were placed into service.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 April 2017
Resolved
STBD and stern nav lights are broken, and must be repaired/replaced.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 19 April 2017
Resolution: New lights were installed and tested all sat.
Navigation › Piloting/Steering › Magnetic Compass
Issued 17 April 2017
Resolved
Magnetic compass is required to be lit, light is extinguished. Repair/replace.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 17 May 2017
Resolution: Compas was replaced, new compass light operates correctly.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 17 April 2017
Resolved
Emergency instructions list is missing. Provide and post.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 17 May 2017
Resolution: List was provided and posted.
Lifesaving › Lifebuoys › Approval
Issued 17 April 2017
Resolved
Life ring is missing reflective tape. Replace.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 17 May 2017
Resolution: New SOLAS tape was applied and is sat.
Lifesaving › Lifefloat › Retroreflective Material
Issued 17 April 2017
Resolved
Life float needs new tape, markings, and general maintenance.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 17 May 2017
Resolution: Life floats were completely rebuilt and repainted and marked.