MAURY USCG vessel records Sign in
← All vessels

SAFARI DIVER

SAFARI DIVER is a 1995 passenger vessel (inspected). The Coast Guard has recorded 51 inspections since 1996, most recently in July 2021, along with 87 deficiencies and 3 casualty investigations between 2012 and 2021.

Records from 1996 to 2021. Most recent: inspection, 18 July 2021.

Built
1995
Last inspected
18 July 2021
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC4166
430688
Flag
UNITED STATES
367020180 (licence lapsed)
Maury page id
psix-430688

Inspections, by type

…with no type recorded7
Years with a record 23 calendar years (1996–2021)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)34.0 ft × 12.0 ft × 4.0 ft
Registered tonnagegross 10 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGRANTS FIBERGLASSING INC · MIAMI, FL, UNITED STATES · built 1995
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPOMPANO BEACH, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC4166MMSI 367020180 · expired · compulsorily equipped · granted 23 December 2014, cancelled 3 May 2025
WCU8114MMSI not assigned · expired · compulsorily equipped · granted 5 October 1995, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

AMORAY DIVER Passenger (Inspected) · MISLE 386062 · 12 February 2000 · activity 50690

Inspection history · 51

18 July 2021 Damage Survey · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7260202
18 July 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7275926
29 March 2021 Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7164859
19 February 2021 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7143138
1 February 2021 Type not recorded
No type recorded · USCGC MANATEE (WPB 87363) · USCG Southeast District (CGD-SE) · Activity 7135109
31 March 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6934381
27 February 2020 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6934394
18 January 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6611540
22 March 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6376212
31 January 2018 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6346026
1 April 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6115728
8 December 2016 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6054449
20 October 2016 DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6028263
29 March 2016 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5843060
15 March 2016 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5833395
18 March 2014 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4811855
19 July 2012 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 4388224
17 January 2012 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 4228448
11 January 2012 Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4220042
2 February 2011 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3936100
1 July 2009 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3520162
10 February 2009 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3415779
17 March 2008 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3166621
30 January 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3138052
4 January 2007 Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2849906
8 March 2006 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2596777
7 March 2006 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2603415
21 March 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2315070
23 February 2005 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2297502
3 June 2004 Simplified Stability Test
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2087736
6 May 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2060460
8 March 2004 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2020154
27 February 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1750124
14 February 2002 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1486410
31 January 2002 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1488446
6 April 2001 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1366256
3 March 2000 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 815987
12 February 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 50690
9 February 2000 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1046934
21 January 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1369493
18 January 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1436326
29 January 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 790355
7 January 1999 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1404673
24 February 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 780083
28 January 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 783232
6 January 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 782131
25 July 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 781545
7 March 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1091219
28 February 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1081388
10 January 1996 Hull Examination · Initial Certification · Plan Review "T" Boat
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 883883
4 January 1996 Inclining Experiment
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 880835

Deficiency record · 87

07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 18 January 2019 Resolved
Alarm for installed fire supression not operational at control station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2019
Resolved 24 January 2019
Construction/Loadline › Hull › Side Shell
Issued 16 March 2016 Resolved
Renew as original starboard side rub rail due to delamination.
Action required: 705 - Other - as specified
Due 30 March 2016
Resolved 17 March 2016
Resolution: Vessel renewed as original starboard side rub rail due to delamination.
Construction/Loadline › Penetrations › Flange Pad
Issued 16 March 2016 Resolved
Renew as original swim platform strut support pads on hull stern.
Action required: 705 - Other - as specified
Due 30 March 2016
Resolved 17 March 2016
Resolution: Vessel renewed as original swim platform strut support pads on hull stern.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 11 January 2012 Resolved
Provide documentation for the re-qualification visual inspection for the fixed "Fireboy" fire fighting system. The visual inspection is in lieu of the required 12 year cylinder hydro test. Last hydro 2/99.
Due 18 January 2012
Resolved 13 January 2012
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 January 2012 Resolved
Prove proper operation of the portside sidelight (nav light).
Due 11 January 2012
Resolved 11 January 2012
Resolution: Corrected on the spot. Owner/operator renewed bulb in kind.
Electrical › Electric Supply System (service) › Cable
Issued 30 January 2008 Resolved
Remove all deadend wires from engine room and under control station.
Action required: 705 - Other - as specified
Due 13 February 2008
Resolved 14 February 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 30 January 2008 Resolved
Properly repair searchlight.
Action required: 705 - Other - as specified
Due 30 January 2008
Resolved 14 February 2008
Electrical › Electric Supply System (service) › Cable
Issued 30 January 2008 Resolved
Properly connect all wires associated with transmission pressure system and properly ground.
Action required: 705 - Other - as specified
Due 13 February 2008
Resolved 14 February 2008
Engineering › Lubricating Oil Service System › Hose
Issued 30 January 2008 Resolved
Scale down fittings on hoses in engine room and make ready for USCG Marine Inspectors exam at Dry-dock.
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 14 February 2008
Engineering › Fuel Oil Service System › Tank
Issued 30 January 2008 Resolved
Scale down corrosion on top of both port and starboard fuel tanks and make ready for USCG Marine Inspectors exam at dry-dock.
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 14 February 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 11 January 2007 Resolved
Provide 01 BII Fire extinguisher prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2007
Resolved 19 January 2007
Resolution: fax
Documentation › Certificates/Documents › FCC SSL
Issued 11 January 2007 Resolved
Provide current Radio Telephony certificate.
Action required: 705 - Other - as specified
Due 25 January 2007
Resolved 19 January 2007
Resolution: fax
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 11 January 2007 Resolved
Provide Fixed fire extinguisher system annual servicing report.
Action required: 705 - Other - as specified
Due 1 March 2007
Resolved 2 March 2007
Resolution: Fax
Construction/Loadline › Structures › End Bulkhead
Issued 8 March 2006 Resolved
Properly repair wasted supports to swim platform and wasted wood backing plate.
Condition: Improper/Lack of Maintenance
Due 8 March 2006
Resolved 9 March 2006
Construction/Loadline › Hull › Side Shell
Issued 8 March 2006 Resolved
Properly repair areas in bow and stern fiberglass.
Condition: Damaged By Earlier Event
Due 8 March 2006
Resolved 9 March 2006
Construction/Loadline › Hull › Keel Plate
Issued 8 March 2006 Resolved
Properly repair wasted end of keel strut.
Condition: Improper/Lack of Maintenance
Due 8 March 2006
Resolved 9 March 2006
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 8 March 2006 Resolved
Properly tighten prop nuts.
Condition: Improper/Lack of Maintenance
Due 8 March 2006
Resolved 9 March 2006
Engineering › Steering Gear System › Rudder
Issued 8 March 2006 Resolved
Install proper rudder stop.
Condition: Placed in Improper Service
Due 8 March 2006
Resolved 9 March 2006
Construction/Loadline › Structures › Machinery Space Opening
Issued 8 March 2006 Resolved
Properly seal bulkhead openings in aft engine room bulkhead.
Condition: Placed in Improper Service
Due 8 March 2006
Resolved 9 March 2006
Documentation › Certificates/Documents › FCC SSL
Issued 23 February 2005 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 21 March 2005
Navigation › Piloting/Steering › Marine Charts
Issued 23 February 2005 Resolved
Provide proof of current Coast Pilot [name withheld], and updated area Charts.
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 21 March 2005
Communications › Audible Communications › SPD (Other)
Issued 23 February 2005 Resolved
Provide adequate Sound Producing Device.
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 21 March 2005
Lifesaving › Lifejacket/PFD (Type IV) › Condition
Issued 23 February 2005 Resolved
Replace Life ring grab line and remove old name.
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 21 March 2005
Lifesaving › Rescue Boat Equipment › First Aid Kit
Issued 23 February 2005 Resolved
Provide complete First Aid Kit.
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 21 March 2005
Engineering › Bilge Water Management System › Not Installed
Issued 23 February 2005 Resolved
Properly label Bilge Alarm indicator lights.
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 23 February 2005
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 23 February 2005 Resolved
Provide proof of completion of outstanding Drug Audit items,
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 21 March 2005
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 23 February 2005 Resolved
Provide 2 serviceable PFD's.
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 23 February 2005
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 23 February 2005 Resolved
Provide means of securing sewage overboard valve.
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 23 February 2005
Stability › Incline Test › General
Issued 6 May 2004 Resolved
Complete a satisfactory simplified stability test in the presence of a CG inspector. Vessel's current stability letter is invalid due to installation of bimini top.
Condition: Placed in Improper Service
Due 6 May 2004
Resolved 10 June 2004
Resolution: Completed successful stability test. Letter pending.
Stability › Freeing Ports › General
Issued 6 May 2004 Resolved
Provide plans and calculations to meet drainage requirements for well-deck vessel.
Condition: Placed in Improper Service
Due 6 May 2004
Resolved 10 June 2004
Construction/Loadline › Structures › Deck Plating
Issued 6 May 2004 Resolved
Crop back rotted deck and renew as original, include hatch and wooden plank at aft of engine space.
Condition: Improper/Lack of Maintenance
Due 6 May 2004
Resolved 23 February 2005
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 6 May 2004 Resolved
Make installed toilet operational, or remove same.
Condition: Improper/Lack of Maintenance
Due 6 May 2004
Resolved 23 February 2005
Engineering › Bilge Water Management System › Valve
Issued 6 May 2004 Resolved
Install closure devices (valves) IWO submersible pump penetrations.
Condition: Placed in Improper Service
Due 6 May 2004
Resolved 23 February 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 6 May 2004 Resolved
Remove dead-end wire IWO MSD mascerator pump.
Condition: Improper/Lack of Maintenance
Due 6 May 2004
Resolved 23 February 2005
Engineering › Lubricating Oil Storage/Transfer System › Inlet
Issued 6 May 2004 Resolved
Renew transmission lube oil fittings (wasted).
Condition: Improper/Lack of Maintenance
Due 6 May 2004
Resolved 23 February 2005
Construction/Loadline › Penetrations › Valve Flange
Issued 6 May 2004 Resolved
Double clamp MSD suction line IWO hull penetration/valve.
Condition: Placed in Improper Service
Due 6 May 2004
Resolved 23 February 2005
Engineering › Bilge Water Management System › Not Operational
Issued 6 May 2004 Resolved
Make high level alarm IWO fuel tank compartment (continuous bilge) operable. Wire prevents float movement.
Condition: Placed in Improper Service
Due 6 May 2004
Resolved 23 February 2005
Engineering › Steering Gear System › Bracket/Clamp
Issued 6 May 2004 Resolved
Provide a means of auxilliary steering.
Condition: Placed in Improper Service
Due 6 May 2004
Resolved 23 February 2005
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 6 May 2004 Resolved
Make repairs to the port gunwhale IWO damage.
Condition: Damaged By Earlier Event
Due 6 May 2004
Resolved 23 February 2005
Fire Fighting › Ventilation Systems › Ducts
Issued 6 May 2004 Resolved
Provide vent closures IWO engine room vents.
Condition: Improper Installation
Due 6 May 2004
Resolved 23 February 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 6 May 2004 Resolved
Provide a portable fire extinghuisher IWO the forward cabin.
Condition: Unknown
Due 6 May 2004
Resolved 23 February 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 6 May 2004 Resolved
Prove proper operation of the overide for the installed fixed fire fighting system.
Condition: Unknown
Due 6 May 2004
Resolved 23 February 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 May 2004 Resolved
Renew battery IWO the waterlight and install halyard clip.
Condition: Improper/Lack of Maintenance
Due 6 May 2004
Resolved 23 February 2005
Operations/Management › Equipment Service/Testing › EPIRB
Issued 6 May 2004 Resolved
Renew EPIRB registration, and renew EPIRB battery, and prove hydrostatic release is current.
Condition: Improper/Lack of Maintenance
Due 6 May 2004
Resolved 23 February 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 May 2004 Resolved
Install a stern light to meet navigation regulations.
Condition: Placed in Improper Service
Due 6 May 2004
Resolved 23 February 2005
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 6 May 2004 Resolved
Provide proof of drug program for crew, and/or MIS report attesting same.
Condition: Placed in Improper Service
Due 6 May 2004
Resolved 23 February 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 May 2004 Resolved
Conduct satisfactory fire and MOB drills in the presence of a CG Inspector.
Condition: Improper/Lack of Maintenance
Due 6 May 2004
Resolved 23 February 2005
Operations/Management › Drug and Alcohol Testing
Issued 27 February 2003 Resolved
Provide complete and current drug & alcohol testing program LEGACY COMPONENT DESC: Employee Coverage
Condition: Improper/Lack of Maintenance
Due 7 March 2003
Resolved 18 March 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 27 February 2003 Resolved
Provide rail coarsings I.A.W. 177.35-1(c) or 177.900 (g) LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Due 28 March 2003
Resolved 28 March 2003
Operations/Management › Passenger Operations
Issued 27 February 2003 Resolved
Provide method of accomplishing passenger count & emergency POC LEGACY COMPONENT DESC: Passenger Count
Condition: Improper/Lack of Maintenance
Due 3 March 2003
Resolved 18 March 2003
Lifesaving › Hand Flares › Quantity
Issued 27 February 2003 Resolved
Provide three additional smoke flares
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2003
Navigation › Piloting/Steering
Issued 27 February 2003 Resolved
Provide current navigation publications LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Improper/Lack of Maintenance
Due 3 March 2003
Resolved 18 March 2003
Navigation › Collision/Grounding Avoidance
Issued 27 February 2003 Resolved
Relocate side lights I.A.W. COLREGS LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper Installation
Due 10 March 2003
Resolved 18 March 2003
Lifesaving › Lifejacket/PFD (General)
Issued 27 February 2003 Resolved
Relocate life jackets for appropriate dispersion throughout vessel LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 10 March 2003
Resolved 18 March 2003
Engineering › Bilge Water Management System
Issued 27 February 2003 Resolved
Install valves on the thru-hull fittings for two electric submersible pumps LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Due 10 March 2003
Resolved 18 March 2003
Engineering › Bilge Water Management System
Issued 27 February 2003 Resolved
Ensure bilge pump electrical wiring connections are waterproof LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 5 March 2003
Resolved 18 March 2003
Engineering › Bilge Water Management System
Issued 27 February 2003 Resolved
Properly label bilge high water alarms LEGACY COMPONENT DESC: Pump
Due 1 March 2003
Resolved 18 March 2003
Electrical › Lighting (emergency)
Issued 27 February 2003 Resolved
Provide two flashlights LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2003
Lifesaving › Line-Throwing Appliances › Lines
Issued 27 February 2003 Resolved
Replace lifeline for ring life buoy
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2003
Lifesaving › Buoyant Apparatus › Projectiles
Issued 27 February 2003 Resolved
Replace ring life buoy
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2003
Navigation › Collision/Grounding Avoidance
Issued 27 February 2003 Resolved
Provide bell for navigation purposes LEGACY COMPONENT DESC: Bell
Condition: Improper/Lack of Maintenance
Due 5 March 2003
Resolved 18 March 2003
Pollution Prevention/Response › Prevention Equipment
Issued 14 February 2002 Resolved
Renew broken MSD vent where it penetrates the hull. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Unknown
Due 1 March 2002
Resolved 21 February 2002
Pollution Prevention/Response › Prevention Equipment
Issued 14 February 2002 Resolved
Install positive shut off valve in the MSD over board hull penetration. LEGACY COMPONENT DESC: Sewage System Valve
Due 1 March 2002
Resolved 21 February 2002
Navigation
Issued 6 April 2001 Resolved
Prior to 30APR01, provide means to prevent rudder from going hard left to prvent leaking from rudder post packing.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Accommodation/Occupational Safety
Issued 6 April 2001 Resolved
Prior to 30APR01, repair all seats for the safety of passengers.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Accommodation/Occupational Safety
Issued 6 April 2001 Resolved
Prior to 30APR01, provide 12 inch coursing on FWD and AFT rails.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Construction/Loadline
Issued 6 April 2001 Resolved
Prior to 30APR01, make AFT hatch operable by hand.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Construction/Loadline
Issued 6 April 2001 Resolved
Prior to 30APR01, label bilge high level alarms for voids covered.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Lifesaving
Issued 6 April 2001 Resolved
Prior to the carriage of passengers, provide a life float IAW 46 CFR 180.15.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Fire Fighting
Issued 21 January 2000 Resolved
Provide closures to the engine room vents._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Navigation
Issued 21 January 2000 Resolved
Repair the tiller._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Lifesaving
Issued 21 January 2000 Resolved
Provide a watertight container for the distress flares._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Lifesaving
Issued 21 January 2000 Resolved
Provide new retro-reflective tape on all PFDs as needed._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Lifesaving
Issued 21 January 2000 Resolved
Provide a current registration for the EPIRB._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Engineering
Issued 7 January 1999 Resolved
Mark fuel shut off valves._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1999
Resolved 29 January 1999
Engineering
Issued 7 January 1999 Resolved
Repair shaft vibration._x001C_ _x001C_ This item to be corrected prior to carrying passengers for hire._x001C_ _x001C_
Condition: Unknown
Due 7 February 1999
Resolved 29 January 1999
Navigation
Issued 7 January 1999 Resolved
Repair the stern and anchor light._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1999
Resolved 29 January 1999
Lifesaving
Issued 7 January 1999 Resolved
Provide new retro-reflective tape on all PFDs._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1999
Resolved 29 January 1999
Documentation
Issued 7 January 1999 Resolved
Provide a vessel log book with all required entires._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1999
Resolved 29 January 1999
Documentation
Issued 7 January 1999 Resolved
Provide proof of a current drug testing program._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1999
Resolved 29 January 1999
Lifesaving
Issued 7 January 1999 Resolved
Provide a proper holder for the waterlight on the life float._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1999
Resolved 29 January 1999
Lifesaving
Issued 28 January 1998 Resolved
Provide 1 red flare._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Lifesaving
Issued 28 January 1998 Resolved
Provide an emergency broadcast placard._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Lifesaving
Issued 10 January 1996 Resolved
Stencil lifefloat capacity on lifefloat.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Lifesaving
Issued 10 January 1996 Resolved
Paint over old stencil for child lifejacket stowage area._x001C_ Stencil new lifejacket stowage area.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Navigation
Issued 10 January 1996 Resolved
Remount magnetic compass on upper control station._x001C_ Calibrate both compasses, magnetic on upper station and digital on lower station.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Accommodation/Occupational Safety
Issued 10 January 1996 Resolved
Provide a positive means to lock the MSD overboard valve.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996

Casualty record · 3

20 December 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4535271
1 April 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6115728
18 July 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7275926
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.