Records from 1996 to 2021. Most recent: inspection, 18 July 2021.
Inspection history · 51
18 July 2021
Damage Survey · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7260202
18 July 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7275926
29 March 2021
Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7164859
19 February 2021
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7143138
1 February 2021
Type not recorded
No type recorded · USCGC MANATEE (WPB 87363) · USCG Southeast District (CGD-SE) · Activity 7135109
31 March 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6934381
27 February 2020
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6934394
18 January 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6611540
22 March 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6376212
31 January 2018
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6346026
1 April 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6115728
8 December 2016
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6054449
20 October 2016
DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6028263
29 March 2016
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5843060
15 March 2016
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5833395
18 March 2014
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4811855
19 July 2012
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 4388224
17 January 2012
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 4228448
11 January 2012
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4220042
2 February 2011
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3936100
1 July 2009
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3520162
10 February 2009
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3415779
17 March 2008
Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3166621
30 January 2008
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3138052
4 January 2007
Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2849906
8 March 2006
Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2596777
7 March 2006
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2603415
21 March 2005
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2315070
23 February 2005
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2297502
3 June 2004
Simplified Stability Test
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2087736
6 May 2004
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2060460
8 March 2004
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2020154
27 February 2003
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1750124
14 February 2002
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1486410
31 January 2002
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1488446
6 April 2001
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1366256
3 March 2000
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 815987
12 February 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 50690
9 February 2000
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1046934
21 January 2000
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1369493
18 January 2000
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1436326
29 January 1999
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 790355
7 January 1999
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1404673
24 February 1998
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 780083
28 January 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 783232
6 January 1998
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 782131
25 July 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 781545
7 March 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1091219
28 February 1996
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1081388
10 January 1996
Hull Examination · Initial Certification · Plan Review "T" Boat
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 883883
4 January 1996
Inclining Experiment
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 880835
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 18 January 2019
Resolved
Alarm for installed fire supression not operational at control station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2019
Resolved 24 January 2019
Construction/Loadline › Hull › Side Shell
Issued 16 March 2016
Resolved
Renew as original starboard side rub rail due to delamination.
Action required: 705 - Other - as specified
Due 30 March 2016
Resolved 17 March 2016
Resolution: Vessel renewed as original starboard side rub rail due to delamination.
Construction/Loadline › Penetrations › Flange Pad
Issued 16 March 2016
Resolved
Renew as original swim platform strut support pads on hull stern.
Action required: 705 - Other - as specified
Due 30 March 2016
Resolved 17 March 2016
Resolution: Vessel renewed as original swim platform strut support pads on hull stern.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 11 January 2012
Resolved
Provide documentation for the re-qualification visual inspection for the fixed "Fireboy" fire fighting system. The visual inspection is in lieu of the required 12 year cylinder hydro test. Last hydro 2/99.
Due 18 January 2012
Resolved 13 January 2012
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 January 2012
Resolved
Prove proper operation of the portside sidelight (nav light).
Due 11 January 2012
Resolved 11 January 2012
Resolution: Corrected on the spot. Owner/operator renewed bulb in kind.
Electrical › Electric Supply System (service) › Cable
Issued 30 January 2008
Resolved
Remove all deadend wires from engine room and under control station.
Action required: 705 - Other - as specified
Due 13 February 2008
Resolved 14 February 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 30 January 2008
Resolved
Properly repair searchlight.
Action required: 705 - Other - as specified
Due 30 January 2008
Resolved 14 February 2008
Electrical › Electric Supply System (service) › Cable
Issued 30 January 2008
Resolved
Properly connect all wires associated with transmission pressure system and properly ground.
Action required: 705 - Other - as specified
Due 13 February 2008
Resolved 14 February 2008
Engineering › Lubricating Oil Service System › Hose
Issued 30 January 2008
Resolved
Scale down fittings on hoses in engine room and make ready for USCG Marine Inspectors exam at Dry-dock.
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 14 February 2008
Engineering › Fuel Oil Service System › Tank
Issued 30 January 2008
Resolved
Scale down corrosion on top of both port and starboard fuel tanks and make ready for USCG Marine Inspectors exam at dry-dock.
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 14 February 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 11 January 2007
Resolved
Provide 01 BII Fire extinguisher prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2007
Resolved 19 January 2007
Resolution: fax
Documentation › Certificates/Documents › FCC SSL
Issued 11 January 2007
Resolved
Provide current Radio Telephony certificate.
Action required: 705 - Other - as specified
Due 25 January 2007
Resolved 19 January 2007
Resolution: fax
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 11 January 2007
Resolved
Provide Fixed fire extinguisher system annual servicing report.
Action required: 705 - Other - as specified
Due 1 March 2007
Resolved 2 March 2007
Resolution: Fax
Construction/Loadline › Structures › End Bulkhead
Issued 8 March 2006
Resolved
Properly repair wasted supports to swim platform and wasted wood backing plate.
Condition: Improper/Lack of Maintenance
Due 8 March 2006
Resolved 9 March 2006
Construction/Loadline › Hull › Side Shell
Issued 8 March 2006
Resolved
Properly repair areas in bow and stern fiberglass.
Condition: Damaged By Earlier Event
Due 8 March 2006
Resolved 9 March 2006
Construction/Loadline › Hull › Keel Plate
Issued 8 March 2006
Resolved
Properly repair wasted end of keel strut.
Condition: Improper/Lack of Maintenance
Due 8 March 2006
Resolved 9 March 2006
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 8 March 2006
Resolved
Properly tighten prop nuts.
Condition: Improper/Lack of Maintenance
Due 8 March 2006
Resolved 9 March 2006
Engineering › Steering Gear System › Rudder
Issued 8 March 2006
Resolved
Install proper rudder stop.
Condition: Placed in Improper Service
Due 8 March 2006
Resolved 9 March 2006
Construction/Loadline › Structures › Machinery Space Opening
Issued 8 March 2006
Resolved
Properly seal bulkhead openings in aft engine room bulkhead.
Condition: Placed in Improper Service
Due 8 March 2006
Resolved 9 March 2006
Documentation › Certificates/Documents › FCC SSL
Issued 23 February 2005
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 21 March 2005
Navigation › Piloting/Steering › Marine Charts
Issued 23 February 2005
Resolved
Provide proof of current Coast Pilot [name withheld], and updated area Charts.
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 21 March 2005
Communications › Audible Communications › SPD (Other)
Issued 23 February 2005
Resolved
Provide adequate Sound Producing Device.
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 21 March 2005
Lifesaving › Lifejacket/PFD (Type IV) › Condition
Issued 23 February 2005
Resolved
Replace Life ring grab line and remove old name.
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 21 March 2005
Lifesaving › Rescue Boat Equipment › First Aid Kit
Issued 23 February 2005
Resolved
Provide complete First Aid Kit.
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 21 March 2005
Engineering › Bilge Water Management System › Not Installed
Issued 23 February 2005
Resolved
Properly label Bilge Alarm indicator lights.
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 23 February 2005
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 23 February 2005
Resolved
Provide proof of completion of outstanding Drug Audit items,
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 21 March 2005
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 23 February 2005
Resolved
Provide 2 serviceable PFD's.
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 23 February 2005
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 23 February 2005
Resolved
Provide means of securing sewage overboard valve.
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 23 February 2005
Stability › Incline Test › General
Issued 6 May 2004
Resolved
Complete a satisfactory simplified stability test in the presence of a CG inspector. Vessel's current stability letter is invalid due to installation of bimini top.
Condition: Placed in Improper Service
Due 6 May 2004
Resolved 10 June 2004
Resolution: Completed successful stability test. Letter pending.
Stability › Freeing Ports › General
Issued 6 May 2004
Resolved
Provide plans and calculations to meet drainage requirements for well-deck vessel.
Condition: Placed in Improper Service
Due 6 May 2004
Resolved 10 June 2004
Construction/Loadline › Structures › Deck Plating
Issued 6 May 2004
Resolved
Crop back rotted deck and renew as original, include hatch and wooden plank at aft of engine space.
Condition: Improper/Lack of Maintenance
Due 6 May 2004
Resolved 23 February 2005
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 6 May 2004
Resolved
Make installed toilet operational, or remove same.
Condition: Improper/Lack of Maintenance
Due 6 May 2004
Resolved 23 February 2005
Engineering › Bilge Water Management System › Valve
Issued 6 May 2004
Resolved
Install closure devices (valves) IWO submersible pump penetrations.
Condition: Placed in Improper Service
Due 6 May 2004
Resolved 23 February 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 6 May 2004
Resolved
Remove dead-end wire IWO MSD mascerator pump.
Condition: Improper/Lack of Maintenance
Due 6 May 2004
Resolved 23 February 2005
Engineering › Lubricating Oil Storage/Transfer System › Inlet
Issued 6 May 2004
Resolved
Renew transmission lube oil fittings (wasted).
Condition: Improper/Lack of Maintenance
Due 6 May 2004
Resolved 23 February 2005
Construction/Loadline › Penetrations › Valve Flange
Issued 6 May 2004
Resolved
Double clamp MSD suction line IWO hull penetration/valve.
Condition: Placed in Improper Service
Due 6 May 2004
Resolved 23 February 2005
Engineering › Bilge Water Management System › Not Operational
Issued 6 May 2004
Resolved
Make high level alarm IWO fuel tank compartment (continuous bilge) operable. Wire prevents float movement.
Condition: Placed in Improper Service
Due 6 May 2004
Resolved 23 February 2005
Engineering › Steering Gear System › Bracket/Clamp
Issued 6 May 2004
Resolved
Provide a means of auxilliary steering.
Condition: Placed in Improper Service
Due 6 May 2004
Resolved 23 February 2005
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 6 May 2004
Resolved
Make repairs to the port gunwhale IWO damage.
Condition: Damaged By Earlier Event
Due 6 May 2004
Resolved 23 February 2005
Fire Fighting › Ventilation Systems › Ducts
Issued 6 May 2004
Resolved
Provide vent closures IWO engine room vents.
Condition: Improper Installation
Due 6 May 2004
Resolved 23 February 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 6 May 2004
Resolved
Provide a portable fire extinghuisher IWO the forward cabin.
Condition: Unknown
Due 6 May 2004
Resolved 23 February 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 6 May 2004
Resolved
Prove proper operation of the overide for the installed fixed fire fighting system.
Condition: Unknown
Due 6 May 2004
Resolved 23 February 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 May 2004
Resolved
Renew battery IWO the waterlight and install halyard clip.
Condition: Improper/Lack of Maintenance
Due 6 May 2004
Resolved 23 February 2005
Operations/Management › Equipment Service/Testing › EPIRB
Issued 6 May 2004
Resolved
Renew EPIRB registration, and renew EPIRB battery, and prove hydrostatic release is current.
Condition: Improper/Lack of Maintenance
Due 6 May 2004
Resolved 23 February 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 May 2004
Resolved
Install a stern light to meet navigation regulations.
Condition: Placed in Improper Service
Due 6 May 2004
Resolved 23 February 2005
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 6 May 2004
Resolved
Provide proof of drug program for crew, and/or MIS report attesting same.
Condition: Placed in Improper Service
Due 6 May 2004
Resolved 23 February 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 May 2004
Resolved
Conduct satisfactory fire and MOB drills in the presence of a CG Inspector.
Condition: Improper/Lack of Maintenance
Due 6 May 2004
Resolved 23 February 2005
Operations/Management › Drug and Alcohol Testing
Issued 27 February 2003
Resolved
Provide complete and current drug & alcohol testing program LEGACY COMPONENT DESC: Employee Coverage
Condition: Improper/Lack of Maintenance
Due 7 March 2003
Resolved 18 March 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 27 February 2003
Resolved
Provide rail coarsings I.A.W. 177.35-1(c) or 177.900 (g) LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Due 28 March 2003
Resolved 28 March 2003
Operations/Management › Passenger Operations
Issued 27 February 2003
Resolved
Provide method of accomplishing passenger count & emergency POC LEGACY COMPONENT DESC: Passenger Count
Condition: Improper/Lack of Maintenance
Due 3 March 2003
Resolved 18 March 2003
Lifesaving › Hand Flares › Quantity
Issued 27 February 2003
Resolved
Provide three additional smoke flares
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2003
Navigation › Piloting/Steering
Issued 27 February 2003
Resolved
Provide current navigation publications LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Improper/Lack of Maintenance
Due 3 March 2003
Resolved 18 March 2003
Navigation › Collision/Grounding Avoidance
Issued 27 February 2003
Resolved
Relocate side lights I.A.W. COLREGS LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper Installation
Due 10 March 2003
Resolved 18 March 2003
Lifesaving › Lifejacket/PFD (General)
Issued 27 February 2003
Resolved
Relocate life jackets for appropriate dispersion throughout vessel LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 10 March 2003
Resolved 18 March 2003
Engineering › Bilge Water Management System
Issued 27 February 2003
Resolved
Install valves on the thru-hull fittings for two electric submersible pumps LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Due 10 March 2003
Resolved 18 March 2003
Engineering › Bilge Water Management System
Issued 27 February 2003
Resolved
Ensure bilge pump electrical wiring connections are waterproof LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 5 March 2003
Resolved 18 March 2003
Engineering › Bilge Water Management System
Issued 27 February 2003
Resolved
Properly label bilge high water alarms LEGACY COMPONENT DESC: Pump
Due 1 March 2003
Resolved 18 March 2003
Electrical › Lighting (emergency)
Issued 27 February 2003
Resolved
Provide two flashlights LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2003
Lifesaving › Line-Throwing Appliances › Lines
Issued 27 February 2003
Resolved
Replace lifeline for ring life buoy
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2003
Lifesaving › Buoyant Apparatus › Projectiles
Issued 27 February 2003
Resolved
Replace ring life buoy
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2003
Navigation › Collision/Grounding Avoidance
Issued 27 February 2003
Resolved
Provide bell for navigation purposes LEGACY COMPONENT DESC: Bell
Condition: Improper/Lack of Maintenance
Due 5 March 2003
Resolved 18 March 2003
Pollution Prevention/Response › Prevention Equipment
Issued 14 February 2002
Resolved
Renew broken MSD vent where it penetrates the hull. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Unknown
Due 1 March 2002
Resolved 21 February 2002
Pollution Prevention/Response › Prevention Equipment
Issued 14 February 2002
Resolved
Install positive shut off valve in the MSD over board hull penetration. LEGACY COMPONENT DESC: Sewage System Valve
Due 1 March 2002
Resolved 21 February 2002
Navigation
Issued 6 April 2001
Resolved
Prior to 30APR01, provide means to prevent rudder from going hard left to prvent leaking from rudder post packing.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Accommodation/Occupational Safety
Issued 6 April 2001
Resolved
Prior to 30APR01, repair all seats for the safety of passengers.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Accommodation/Occupational Safety
Issued 6 April 2001
Resolved
Prior to 30APR01, provide 12 inch coursing on FWD and AFT rails.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Construction/Loadline
Issued 6 April 2001
Resolved
Prior to 30APR01, make AFT hatch operable by hand.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Construction/Loadline
Issued 6 April 2001
Resolved
Prior to 30APR01, label bilge high level alarms for voids covered.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Lifesaving
Issued 6 April 2001
Resolved
Prior to the carriage of passengers, provide a life float IAW 46 CFR 180.15.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Fire Fighting
Issued 21 January 2000
Resolved
Provide closures to the engine room vents._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Navigation
Issued 21 January 2000
Resolved
Repair the tiller._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Lifesaving
Issued 21 January 2000
Resolved
Provide a watertight container for the distress flares._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Lifesaving
Issued 21 January 2000
Resolved
Provide new retro-reflective tape on all PFDs as needed._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Lifesaving
Issued 21 January 2000
Resolved
Provide a current registration for the EPIRB._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Engineering
Issued 7 January 1999
Resolved
Mark fuel shut off valves._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1999
Resolved 29 January 1999
Engineering
Issued 7 January 1999
Resolved
Repair shaft vibration._x001C_ _x001C_ This item to be corrected prior to carrying passengers for hire._x001C_ _x001C_
Condition: Unknown
Due 7 February 1999
Resolved 29 January 1999
Navigation
Issued 7 January 1999
Resolved
Repair the stern and anchor light._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1999
Resolved 29 January 1999
Lifesaving
Issued 7 January 1999
Resolved
Provide new retro-reflective tape on all PFDs._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1999
Resolved 29 January 1999
Documentation
Issued 7 January 1999
Resolved
Provide a vessel log book with all required entires._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1999
Resolved 29 January 1999
Documentation
Issued 7 January 1999
Resolved
Provide proof of a current drug testing program._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1999
Resolved 29 January 1999
Lifesaving
Issued 7 January 1999
Resolved
Provide a proper holder for the waterlight on the life float._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1999
Resolved 29 January 1999
Lifesaving
Issued 28 January 1998
Resolved
Provide 1 red flare._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Lifesaving
Issued 28 January 1998
Resolved
Provide an emergency broadcast placard._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Lifesaving
Issued 10 January 1996
Resolved
Stencil lifefloat capacity on lifefloat.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Lifesaving
Issued 10 January 1996
Resolved
Paint over old stencil for child lifejacket stowage area._x001C_ Stencil new lifejacket stowage area.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Navigation
Issued 10 January 1996
Resolved
Remount magnetic compass on upper control station._x001C_ Calibrate both compasses, magnetic on upper station and digital on lower station.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Accommodation/Occupational Safety
Issued 10 January 1996
Resolved
Provide a positive means to lock the MSD overboard valve.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996