MAURY USCG vessel records
← All vessels

BLIND SQUIRREL

Built
1993
Last inspected
27 January 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 January 2026
…with no type recorded3
Operational controls 1 with no removal date recorded
Years with a record 10 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK2367
386536
Flag
UNITED STATES
Maury page id
psix-386536

Documentation record

Registered dimensions (L × B × D)53.7 ft × 20.0 ft × 7.2 ft
Registered tonnagegross 78 / net 53
ITC dimensions (L × B × D)53.7 ft × 20.0 ft × 7.2 ft
ITC tonnageNot recorded
BuilderFREEPORT SHPBLDG & MARINE · FREEPORT, FL, UNITED STATES · built 1993
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portKEY WEST, FL
Endorsements, as the file codes themcw_un, rec
DocumentationValid · issued 9 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it78 - Regulatory (Subpart C or D), Gross Ton
53 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 23 inspections, each with its date, unit and type; 82 deficiencies with the resolution recorded against each; 1 operational control with no removal date recorded; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

27 January 2026 In-Service Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8302081
6 October 2025 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8247265
22 July 2025 Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 8192309
28 January 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8071747
3 March 2024 Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 7873507
1 November 2023 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7836430
8 September 2023 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7791066
6 September 2023 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7786268
27 August 2023 Administrative Inspection · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7777518
1 November 2022 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7586441
26 August 2022 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7554946
26 January 2022 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7381985
9 August 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7263054
11 March 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7154048
23 November 2020 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7101423
17 March 2020 Administrative Inspection · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6919691
17 September 2019 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6813874
9 September 2019 Administrative Inspection · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6807303
13 December 2018 Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6595932
1 May 2018 Administrative Inspection · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6411306
27 October 2017 Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6296402
30 March 2017 Internal Structural Exam · Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6110765
17 March 2017 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6106547

Deficiency record · 82

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 October 2025 Resolved
Prove operation of the vessel's watch keeping monitoring devices used to ensure the wakefulness of the watchmen prior to carrying overnight passengers.
Action required: 705 - Other - as specified
Resolved 5 November 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 October 2025 Resolved
Prove operation of the vessel's interconnected fire detection system prior to carrying overnight passengers or operating beyond 20 miles from a harbor of safe refuge.
Action required: 705 - Other - as specified
Resolved 5 November 2025
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 January 2025 Resolved
Mount the new EPIRB in a float free location prior to operating beyond three miles from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 January 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 January 2025 Resolved
Prove operation of the vessel's watch keeping monitoring devices used to ensure the wakefulness of the watchmen prior to carrying overnight passengers.
Action required: 705 - Other - as specified
Resolved 6 October 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 January 2025 Resolved
Provide a valid FCC Safety Radio Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 10 February 2025
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 28 January 2025 Resolved
Provide suitable insulation around the hot piping on the starboard engine exhaust.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 29 January 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 January 2025 Resolved
Permanently mount the submersible electronic bilge pump located in the lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 29 January 2025
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 September 2023 Resolved
Identified a cracked weld on the plate insert below the port generator exhaust outlet. Crack is on the forward and forward upper side of the insert and visible on exterior and interior side of the weld. Instructed owner to grind out weld area as marked for further inspection.
Action required: 705 - Other - as specified
Resolved 7 September 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2023 Resolved
Vessel Captain reported a malfunction in the starboard shifter module causing the starboard engine to go into and remain in neutral.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 1 November 2022 Resolved
Provide a suitable Rescue Ladder in lieu of a Rescue Boat prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2022
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 1 November 2022 Resolved
Conduct satisfactory Man Overboard drill prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 November 2022 Resolved
Provide proof of pre-employment chemical testing for all crewmembers prior to them working in a safety sensitive position.
Action required: 705 - Other - as specified
Resolved 3 November 2022
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 November 2022 Resolved
On vessel's with overnight accommodations, Fire fighting training must include monthly emergency egress drills. Conduct and log or otherwise document the training.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 November 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 November 2022 Resolved
Provide a valid FCC Safety Radio Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 November 2022
14 - Pollution Prevention › 141 - MARPOL Annex I › Segregation of oil and water ballast
Issued 1 February 2022 Resolved
Clean excess oil from bilges. Do not pump bilge until rectified except in emergency.
Action required: 705 - Other - as specified
Due 1 February 2022
Resolved 2 February 2022
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 1 February 2022 Resolved
Provide lighted or photoluminescent signage to mark egress from pax accommodation space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2022
Resolved 2 February 2022
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 1 February 2022 Resolved
Log man overboard drill.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 1 November 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 February 2022 Resolved
Remark fire buckets
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 2 February 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 February 2022 Resolved
Remark life ring
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2022
Resolved 2 February 2022
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 March 2021 Resolved
The battery for the Emergency Position Indicating Radiobeacon was expired. Vessel restricted to operating within 3 miles from shore. Rectify deficiency by 11APR21.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 April 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 March 2021 Resolved
Abandonship, Man Overboard, and Fire Fighting training and drills were not being logged. Conduct and log training to include the date the training or drill occurred as well as a general description and list of attendees.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 March 2021 Resolved
Provide a total of six hand red flare distress signals and six hand orange smoke distress signals (or 12 hand red flare distress signals meeting 46 CFR 160.021).
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 March 2021 Resolved
Provide a first-aid kit approved under approval series 160.401 or its equivalent contents and instructions.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 March 2020 Resolved
Repair/replace steaming white navigation light. Vessel restricted from operating in times of reduced visibility (sunset-sunrise).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 March 2020 Resolved
Repair/replace all-around anchor white navigation light. Vessel restricted from operating in times of reduced visibility (sunset-sunrise).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 March 2020 Resolved
Replace battery for floating waterlight supplied to 22pax life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2020
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 17 March 2020 Resolved
Program VHF radio with current MMSI#
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2020
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 March 2020 Resolved
Provide up to date publications (Coast Pilot [name withheld], Tide/Current tables)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2020
Resolution: Pubs onboard
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 March 2020 Resolved
Repair top 22 pax life float, top of life float is no longer international orange due to sun damage. Life float may be repaired by painting using approved [name withheld] paint.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 May 2020
Resolution: Received photo of life float painted.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 March 2020 Resolved
Label High water alarm locations (Laz, Engine Room, Accommodations)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2020
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 March 2020 Resolved
Replace hydrostatic release for EPIRB, hydro found expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2020
Resolution: replaced
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 March 2020 Resolved
Provide a first aid kit with all required contents and that are not expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 23 December 2019 Resolved
Demonstrate aluminum hull inserts on Port and STBD side are sound and leak free. While conducting high water pressure test, leaks were visible on the top welds just below the exhaust.
Action required: 705 - Other - as specified
Resolved 24 December 2019
Resolution: Ground out bad sections and rewelded.
09 - Working and Living Conditions › 091 - Living Conditions › Berth dimensions, etc.
Issued 9 October 2019 Resolved
Each berth must measure atleast 74 inches, by 24 inches and have at least 24 inches clear space above. Two berths are less than the required 24inches of clear head space. Provide a written plan to the OCMI on how the vessel will achieve compliance or equivalent level of safety with these required standards within 30 days (09NOV2019).
Action required: 705 - Other - as specified
Resolved 2 March 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 October 2019 Resolved
Means of escape must be adequately marked both inside and out. Escape hatch is not adequately marked on outside. Ensure that hatch is marked with two inch lettering "Emergency Escape - Keep Clear"
Action required: 705 - Other - as specified
Resolved 24 December 2019
Resolution: Marked
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 October 2019 Resolved
Each vessel shall have a suitable number of watchmen to ensure that patrols are conducted during night time, whether or not the vessel is underway, to guard against, and give alarm in case of , a fire, man overboard, or other dangerous situation. For these watchmen, provide a list of areas/ procedures to use while on watch. Additionally, provide an entry in the log for watch relief.
Action required: 705 - Other - as specified
Resolved 18 March 2020
Resolution: Procedures in place.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 9 October 2019 Resolved
On a vessel of more than 24 hours duration, passengers shall don lifejackets and and go to the appropriate embarkation station. Ensure that emergency escape drills are conducted each time overnight passengers are embarked to ensure their understanding of emergency escape routes and how to use hatch. These drills should be logged in the ship's log.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: procedures in place
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 October 2019 Resolved
Vertical means of escape from passenger accommodation spaces do not have adequate ladder steps to facilitate an efficient evacuation in the event of an emergency, 31" from top ladder rung to main deck. Provide adequate steps to the satisfaction of the Marine Inspector.
Action required: 705 - Other - as specified
Resolved 24 December 2019
Resolution: Step installed to break up gap above top rack to escape hatch.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 9 October 2019 Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape. Vessel emergency lighting currently does not have power to demonstrate a power failure to facilitate a safe evacuation in the event of an emergency. Provide automatically actuating lighting to facilitate escape in an emergency.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: Operational
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 9 October 2019 Resolved
Mattresses are to be treated to give it fire resistant properties. There is no indication that the current mattresses are in any way flame resistant. Provide verification of fire resistance of mattresses.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: new mattresses ordered
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 9 October 2019 Resolved
Vessel must have a public address system that is audible in all accommodation spaces. Demonstrate Public address system is audible in the all accommodation spaces.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: Operational
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 October 2019 Resolved
Forward hatch that is used as a means of escape shall have instructions labeled "PUSH UP - TURN LEFT" in direct vicinity of hatch at least 2 inches high.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: Label in place
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 October 2019 Resolved
Ensure at least 74" of clearance is available in doorway exiting forward overnight passenger accommodations.
Action required: 705 - Other - as specified
Resolved 24 December 2019
Resolution: Corrected by removing trim board
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 9 October 2019 Resolved
Replace lighting branch circuit breakers with breakers rated at not more than 15amphers, lighting circuits had 20amp breakers installed.
Action required: 705 - Other - as specified
Resolved 24 December 2019
Resolution: Replaced fuse with 15amp
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 9 October 2019 Resolved
Vertical and horizontal surfaces within 3 feet of cooking appliances must be covered with a material that has a ASTM E-84 flame spread rating of not more than 75. Vessel has proposed coating the surfaces with FX FlameGuard. Follow prescribed application procedures from manufacture.
Action required: 705 - Other - as specified
Resolved 24 December 2019
Resolution: Surfaces treated with FX FlameGuard
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 9 October 2019 Resolved
Carryout repair proposal that was submitted on October 1st, 2019 to crop and renew the Port and STBD aft quarters and forward doublers. Repairs for a aluminum hull (5086) must be at a minimum 18" by 18" area and span at least 1 frame. Corners shall be radius or use relief cuts at a minimum 6". Fit-up shall have no more than a 1/8" root gap and beveled at 60 degrees. Make vessel available for re-inspection when fit-up is complete for each cutout prior to conducting full penetration welds.
Action required: 705 - Other - as specified
Resolved 24 December 2019
Resolution: Repair completed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 25 September 2019 Resolved
Submit plans to local OCMI for repairs to vessels aluminum hull on both Port and STBD aft hulls below exhaust. Plans must include aluminum thickness and number (ie 5086), dimensions, filler metal (rod) to be used. Previous hull inserts were found with deteriorated and cracked welds. Approval must be made prior to conducting repairs. Repairs for an aluminum hull must be at a minimum 18" by 18" area and span at least 1 frame. Corners shall be radius or use relief cuts at a minimum 6". Fit-up shall have no more than a 1/8" root gap and beveled at 60 degrees.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 September 2019 Resolved
Remove small circle doublers on Port and STBD bottom hull near the bow for re-inspection by attending MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 September 2019 Resolved
Make internal of vessel available for Internal Structural Exam (ISE), and demonstrate proper operation of thru-hull fittings.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 September 2019 Resolved
Conduct in-service overnight accommodation inspection
Action required: 705 - Other - as specified
Resolved 27 May 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 September 2019 Resolved
Waste receptacles must be constructed of non-combustible materials. Trash cans in heads are made of plastic. Provide non combustible waste receptacles any time they are used below the main deck.
Action required: 705 - Other - as specified
Resolved 24 December 2019
Resolution: Replaced with metal trashcans
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 September 2019 Resolved
Demonstrate proper operation of thru-hull positive shutoff valves for Port and STBD main engine raw water supply. Valves were not closing completely, estimated 85% closure.
Action required: 705 - Other - as specified
Resolved 24 December 2019
Resolution: Conducted maintenance on valve and demonstrated complete closure.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 9 September 2019 Resolved
Multiple hull welds were found with corrosion, filler metal appears to have more potential for galvanic corrosion than base metal. Grind out identified welds for attending MI to re-inspect prior to conducting any welding. Provide welding rod specifics.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 December 2018 Resolved
Repair/replace two 25 person fiberglass Lifefloats (L/F), both L/F's are constructed with FRP and the shape has been altered from original construction. Vessel is restricted to 3nm from land.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2019
Resolution: Two 25 person Life floats replaced and properly installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 December 2018 Resolved
Demonstrate ability to securely close Engine Room ventilation on STBD side, rod holder that was installed is preventing vent closure device from securing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2018
Resolution: Rod holder that was blocking vent cover was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 December 2018 Resolved
Install circuit breaker or cover for missing circuit breaker on 110 panel in accommodation area, opening poses risk of shock.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2019
Resolution: Covers installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 December 2018 Resolved
Operational Life floats shall be installed as per 180.137(See NVIC 01-83 as provided). Paddles shall be labeled with current vessel name, SOLAS tape needed on multiple areas.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2019
Resolution: New Life Floats outfitted and stowed properly.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 December 2018 Resolved
Post all pages of Stability Letter (02)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 March 2019
Resolution: Both pages posted.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 December 2018 Resolved
Provide FCC Safety Certificate for vessel
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2019
Resolution: FCC cert provided
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 December 2018 Resolved
Tubular gauge glasses, if fitted to diesel fuel tanks must be provided with devices that will automatically close in the event of rupture of the gauge or gauge lines. Currently vessel has manual screw down valves on top and bottom of glass gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2019
Resolution: Special note added.
Lifesaving › Lifefloat › Serviceable
Issued 3 November 2017 Resolved
Found life floats in no service conditions, service life floats to the satisfaction of attending marine inspector. 46CFR180.15(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2017
Resolved 27 November 2017
Resolution: Deficiency cleared
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 November 2017 Resolved
Found lifeline on ring life buoy not been buoyant, replace with right lifeline to the satisfaction of attending marine inspector. 46CFR180.70
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Resolution: Deficiency cleared
Documentation › Markings/Placards › Lifejacket Placard
Issued 3 November 2017 Resolved
Found placards containing instructions for the donning and use of the life jackets to be the wrong type, provide and post right type of placards to the satisfaction of attending marine inspector. 46CFR185.516
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Resolution: Deficiency cleared
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 November 2017 Resolved
Found port side exhaust cooling system hoses in non serviceable condition, install new cooling system hoses to the satisfaction of attending marine inspector. 46CFR176.804(c)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 November 2017
Resolved 27 November 2017
Resolution: Deficiency cleared
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 3 November 2017 Resolved
Found smoke detecting unit not in compliance, install UL217 smoke detectors to the satisfaction of attending marine inspector. 46CFR181.450
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Resolution: Deficiency cleared.
Engineering › Bilge Water Management System › Valve
Issued 3 November 2017 Resolved
Found overboard valve aft frozen, prove proper operation to the satisfaction of attending marine inspector. 46CFR182.520(e)(7)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Resolution: Deficiency cleared.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 3 November 2017 Resolved
Found alternate current pumps improperly connected, prove proper pumps connection to the satisfaction of attending marine inspector. 46CFR183.01-15
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Resolution: Deficiency cleared.
Construction/Loadline › Structures › Door
Issued 3 November 2017 Resolved
Found broken glass door at accommodation, replace glass to the satisfaction of attending marine inspector. 46CFR177.800
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Resolution: Deficiency cleared.
Engineering › Steering Gear System › Ram
Issued 3 November 2017 Resolved
Found starboard steering ram leaking, repair ram to the satisfaction of attending marine inspector. 46CFR176.25-35
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Resolution: Deficiency cleared
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 3 November 2017 Resolved
Found DAPI program not in compliance, prove compliance to the satisfaction of attending marine inspector. 46CFR16
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 30 June 2019
Resolution: Vessel found to be in compliance.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 November 2017 Resolved
FCC documents missing information or having wrong information, update FCC documents to the satisfaction of attending marine inspector. 47CFR80
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Resolution: Deficiency cleared
Communications › Radio Communications › VHF Radiotelephone
Issued 3 November 2017 Resolved
MMSI number not entered in VHF radio, enter MMSI number in VHF radio to the satisfaction of attending marine inspector. 47CFR80
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 30 June 2019
Resolution: Vessel found to be in compliance.
Communications › Radio Communications › VHF Radiotelephone
Issued 3 November 2017 Resolved
Found no emergency broadcast placard posted, post emergency broadcast placard to the satisfaction of attending marine inspector. 46CFR184.506
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Resolution: Deficiency cleared
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 3 November 2017 Resolved
Navigation rules missing, provide navigation rules to the satisfaction of attending marine inspector. 33CFR88.05
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Resolution: Deficiency cleared
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 3 November 2017 Resolved
Nav Charts not up-to-date, up-date nav charts to the satisfaction of attending marine inspector. 46CFR184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Resolution: Deficiency cleared
Documentation › Certificates/Documents › Stability Letter
Issued 3 November 2017 Resolved
Stability Letter not posted at operating station, post stability letter to the satisfaction of attending marine inspector. 46CFR176.306
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Resolution: Deficiency cleared
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 October 2017 Resolved
Found stern light housing broken, replace stern light to the satisfaction of attending marine inspector. 33CFR84.25
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Resolution: Deficiency cleared
Engineering › Bilge Water Management System › Valve
Issued 30 March 2017 Resolved
Positive action valves handle broken, replace to the satisfaction of the attending marine inspector, valves forward starboard side
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 11 October 2017
Resolution: Deficiency cleared.
Construction/Loadline › Hull › Hull Plating
Issued 30 March 2017 Resolved
Pitting around thru hull fittings on port and staboard side, clean for inspection of the attending marine inspector 46 CFR 176.612
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 15 August 2017
Resolution: Deficiency cleared.
Construction/Loadline › Hull › Hull Plating
Issued 30 March 2017 Resolved
Hull welding port and starboard, clean for inspection of the attending MI. 46 CFR 176.612
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 15 August 2017
Resolution: Deficiency cleared.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 March 2017 Resolved
Vessel is overdue for annual inspection that was required between 12/5/15 and 6/5/2016. Vessel's COI is no longer valid and a COI renewal inspection must be completed prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2017
Resolved 30 June 2019
Resolution: Old deficiency from prior [name withheld] never closed out.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 March 2017 Resolved
Submit application for inspection to schedule COI renewal inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2017
Resolved 30 June 2019
Resolution: Deficiency from prior OCMI zone. Completed

Ownership record