MAURY USCG vessel records Sign in
← All vessels

FOREST STAR

FOREST STAR is a 1974 freight ship. The Coast Guard has recorded 25 inspections since 1995, most recently in May 2001, along with 38 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 1995 to 2001. Most recent: inspection, 10 May 2001.

Built
1974
Last inspected
10 May 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7382794 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HP-6265
430005
Flag
PANAMA
—
Maury page id
psix-430005

Inspections, by type

…with no type recorded25
…past their stated due date1
Years with a record 7 calendar years (1995–2001)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1199 - Regulatory (Subpart C or D), Gross Ton
958 - Regulatory (Subpart C or D), Net Ton
2800 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

UNNAMED (FL1280HS) Commercial Fishing Vessel · MISLE 461387 · 26 March 1997 · activity 29803BLIND SQUIRREL Passenger (Inspected) · MISLE 386536 · 27 July 1996 · activity 140608

Inspection history · 25

10 May 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 289766
15 March 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 288340
12 October 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 284366
15 September 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 282145
1 September 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 281622
29 February 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 275125
5 September 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 86376
18 August 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 431706
1 March 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 425856
25 September 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 421101
3 March 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 532595
12 February 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 412680
13 January 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 505733
24 October 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 512479
9 June 1997 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 404643
26 March 1997 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 29803
31 January 1997 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 400001
7 January 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 399228
27 July 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 140608
29 April 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 390594
5 April 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 389651
29 February 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 388212
8 December 1995 Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 385869
1 November 1995 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 384122
24 October 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 384119

Deficiency record · 38

Construction/Loadline
Issued 15 March 2001 Resolved
Class to provide report attesting to the structural integrity of the hull in regards to the port side stern. ILLC 66
Condition: Unknown
Due 15 March 2001
Resolved 20 March 2001
Documentation
Issued 15 March 2001 Resolved
Provide a properly licensed Chief mate in accordance with safe manning Document. STCW 95 I/10
Condition: Unknown
Due 15 March 2001
Resolved 20 March 2001
Fire Fighting
Issued 15 March 2001 Resolved
Prove proper operation of portable emergency fire pump to USCG inspector. SOLAS 60 II/ 65
Condition: Unknown
Due 15 March 2001
Resolved 20 March 2001
Fire Fighting
Issued 15 March 2001 Resolved
Provide proper operational emergency fire pump in accordance with vsl's_x001C_ fire control plan. SOLAS 60 II/65
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Electrical
Issued 1 September 2000 Resolved
REPLACE CRACKED AND MISSING LIGHT COVERS THROUGHOUT CARGO HOLDS. SOLAS 60/II 27
Condition: Unknown
Due 1 October 2000
Resolved 20 November 2000
Engineering
Issued 1 September 2000 Resolved
REPAIR AS ORIGINAL CONTROLLABLE PITCH PROPELLER AND GENERATOR COOLING LINESIN ENGINE ROOMS WHERE SALT DEPOSITS ARE PREVALENT. (SALT DEPOSITS CAUSED BY SALT WATER LEAKING FROM PIPES) SOLAS 60 I/11
Condition: Unknown
Due 1 November 2000
Resolved 15 September 2000
Engineering
Issued 1 September 2000 No resolution recorded
REPAIR AS ORIGINAL SEA CHEST PIPING DURING NEXT DRY DOCK, BUT NO LATER THAN31 JUN 01. SOLAS 60 I/11
Condition: Unknown
Due 30 June 2001 — due date passed with no resolution recorded
Electrical
Issued 1 September 2000 Resolved
REMOVE ELECTRICAL PLUG LEADING INTO ENGINE ROOM TO SUPPLY POWER TO OVERHEADLIGHT AND PERMANENTLY REPAIR AS ORIGINAL. SOLAS 60 II/27
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Fire Fighting
Issued 1 September 2000 Resolved
PROVIDE COVERS OVER OPEN FIRE HYDRANT ON DECK TO PROTECT FROM THE ELEMENTS.SOLAS 60 II/66
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Construction/Loadline
Issued 1 September 2000 Resolved
RENEW WATERTIGHT INTEGRITY OF PORT AND STARBOARD WATERTIGHT DOORS LEADING FROM SUPERSTRUCTURE TO WEATHERDECK. GASKETS DON'T PROPERLY SEAT ON KNIFE EDGE. ILLC 66 ANNEX I/15
Condition: Unknown
Due 1 October 2000
Resolved 15 September 2000
Construction/Loadline
Issued 1 September 2000 Resolved
PROVIDE PROPER CLASS A STRUCTURAL FIRE PROTECTION INTEGRITY FOR PORT/STBD WATERTIGHT DOORS PER FIRE CONTROL PLAN. DOORS ARE FIBERGLASS VICE STEEL INAN A-CLASS SUBDIVISION. SOLAS 60 II/36
Condition: Unknown
Due 1 October 2000
Resolved 20 November 2000
Fire Fighting
Issued 1 September 2000 Resolved
PROVIDE PROPER IMO SYMBOLOGY ON FIRE CONTROL PLAN. SOLAS 74 AMEND II- 2/20.1
Condition: Unknown
Due 1 October 2000
Resolved 20 November 2000
Fire Fighting
Issued 1 September 2000 Resolved
REPAIR BROKEN CO2 FIREFIGHTING OUTLET PIPING THAT IS LOCATED OVERHEAD FORWARD IN UPPER HOLD. SOLAS 60 II/66
Condition: Unknown
Due 1 October 2000
Resolved 15 September 2000
Accommodation/Occupational Safety
Issued 1 September 2000 Resolved
SECURE LADDER LEADING FROM MAIN DECK TO UPPER HOLD. ILLC 66 ANNEX I/25
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Electrical
Issued 1 September 2000 Resolved
PROPERLY SECURE/ENCASE ELECTRICAL WIRES IN JUNCTION BOXES IN ENGINE ROOM. SOLAS 60 II/27.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Construction/Loadline
Issued 1 September 2000 Resolved
REPAIR/REPLACE PORT SIDE WATERTIGHT DOOR WHERE LIGHT CAN BE SEEN THROUGH DOOR WHERE BY WATERTIGHT INTEGRITY IS COMPROMISED. ILLC 66 ANNEX I/15
Condition: Unknown
Due 1 October 2000
Resolved 20 November 2000
Electrical
Issued 1 September 2000 Resolved
PROPERLY SECURE ELECTRICAL WIRES LEADING INTO EXPLOSION PROOF FITTING IN ENGINE ROOM. SOLAS 60 II/27
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Navigation
Issued 25 September 1998 Resolved
PROPERLY REPAIR THE RUDDER ANGLE INDICATOR ON THE BRIDGE SO THAT IT COINCIDES WITH THE INDICATOR IN THE STEERING GEAR ROOM. BRIDGE INDICATOR PRESENTLY READS UP TO 5 DEGREES MORE THAN INDICATOR IN STEERING ROOM._x001C_ SOLAS 74 (amended) V/12(M)
Condition: Unknown
Due 15 March 1999
Resolved 15 March 1999
Fire Fighting
Issued 25 September 1998 Resolved
REPAIR/RENEW AS ORIGINAL DETERIORATED SECTION OF FIREMAIN PIPING IN WAY OF_x001C_LOWER LEVEL ENGINEROOM OVERHEAD WHERE SOFT PATCH IS PRESENTLY LOCATED._x001C_ SOLAS 74 (amended) II-2/21
Condition: Unknown
Due 15 March 1999
Resolved 15 March 1999
Construction/Loadline
Issued 12 February 1998 Resolved
CONDUCT CLASS INSPECTION OF TEMPORARY CEMENT REPAIRS TO PORT AND STARBOARD HAWSERPIPES (FORECASTLE) AND PROVIDE DOCUMENTAION TO SHIP'S CLASS REPORT NOLATER THAN 12MAR98._x001C_ ICLL 66
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Lifesaving
Issued 7 January 1997 Resolved
At next U.S. port provide annual servicing for the 16 person liferaft.
Condition: Unknown
Due 6 March 1997
Resolved 6 March 1997
Lifesaving
Issued 7 January 1997 Resolved
At next U.S. port perform fire fighting and abandon ship drills.
Condition: Unknown
Due 6 March 1997
Resolved 6 March 1997
Construction/Loadline
Issued 5 April 1996 Resolved
RENEW LOADLINE MARKINGS IN A CONTRASTING COLOR TO THE VESSELS HULL._x001C_ ILLC 66 ANNEX I/8
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Lifesaving
Issued 5 April 1996 Resolved
RENEW/REPAIR RETRO-REFLECTIVE TAPE ON LIFEBUOYS THROUGHOUT VESSEL._x001C_ SOLAS 74 AMENDED III/30.2.7
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Navigation
Issued 5 April 1996 Resolved
PROVIDE ON BOARD TIDAL CURRENT TABLES PUBLICATION FOR U.S. WATERS. _x001C_ 33 C.F.R. 164.33(b)
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Lifesaving
Issued 24 October 1995 Resolved
Service or renew outdated hydrostatic release to starboard inflatable liferaft._x001C_ SOLAS 74 AMENDED III/19.8.1_x001C_ _x001C_
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Fire Fighting
Issued 24 October 1995 Resolved
Provide and mount key/hammer for CO2 control station located on main deck aft outside CO2 room. Plexiglass shall be removed and breakable glass installed for access of control in an emergency sitution._x001C_ SOLAS 74 AMENDED II/2-21_x001C_
Condition: Unknown
Due 26 October 1995
Resolved 27 October 1995
Lifesaving
Issued 24 October 1995 Resolved
Poster or signs shall be provided on or in the vicinity of survival craft and their launching controls in. SOLAS 74 AMENDED III/9_x001C_ All symbols related to life saving appliance._x001C_ IMO Resolution A.603(15)_x001C_
Condition: Unknown
Due 13 December 1995
Resolved 13 December 1995
Engineering
Issued 24 October 1995 Resolved
Provide oil transfer procedures on board vessel.
Condition: Unknown
Due 26 October 1995
Resolved 27 October 1995
Fire Fighting
Issued 24 October 1995 Resolved
Service fixed fire extinguishing system._x001C_ SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 24 October 1995
Resolved 2 November 1995
Lifesaving
Issued 24 October 1995 Resolved
Provide and install hydrostatic release to EPIRB._x001C_ SOLAS 74 AMENDED III/19.9_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 October 1995
Resolved 27 October 1995
Lifesaving
Issued 24 October 1995 Resolved
Provide on board equipment for port and starboard lifeboats._x001C_ SOLAS 74 AMENDED III/41.8
Condition: Unknown
Due 26 October 1995
Resolved 27 October 1995
Lifesaving
Issued 24 October 1995 Resolved
Renew retro-reflective tape to port and starboard lifeboat._x001C_ SOLAS 74 AMENDED III/30.2.7_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 October 1995
Resolved 27 October 1995
Lifesaving
Issued 24 October 1995 Resolved
Renew and prove operation of manual pump to port lifeboat._x001C_ SOLAS 74 AMENDED III/41.8
Condition: Unknown
Due 26 October 1995
Resolved 27 October 1995
Fire Fighting
Issued 24 October 1995 Resolved
Renew all firehoses throughout vessel as noted and pressure test to satisfaction of attending U.S. Coast Guard Marine Inspector.
Condition: Unknown
Due 26 October 1995
Resolved 27 October 1995
Lifesaving
Issued 24 October 1995 Resolved
Provide muster list and emergency instruction for engine room._x001C_ SOLAS 74 AMENDED III/8/53
Condition: Unknown
Due 26 October 1995
Resolved 27 October 1995
Lifesaving
Issued 24 October 1995 Resolved
Renew retro-reflective material to all lifejackets, renew 7 lights and 1 whistle to lifejackets.
Condition: Unknown
Due 26 October 1995
Resolved 27 October 1995
Lifesaving
Issued 24 October 1995 Resolved
Provide and post operating instructions for steering gear in steering gear compartment._x001C_ SOLAS 74 AMENDED V/19-2(c)(i)
Condition: Unknown
Due 26 October 1995
Resolved 27 October 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.