MAURY USCG vessel records Sign in
← All vessels

MATILDA

MATILDA is a 1993 freight ship. The Coast Guard has recorded 47 inspections since 1993, most recently in September 2007, along with 19 deficiencies and 6 operational controls.

Records from 1993 to 2007. Most recent: inspection, 15 September 2007.

Built
1993
Last inspected
15 September 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9011935 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
386558
Flag
LIBERIA
—
Maury page id
psix-386558

Inspections, by type

…with no type recorded29
Years with a record 14 calendar years (1993–2007)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it41189 - Convention (Subpart B), Gross Ton
41189 - Simplified, Gross Ton
25692 - Convention (Subpart B), Net Ton
25692 - Simplified, Net Ton
89758 - Displacement, Ton
74868 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

AKRONEOS Freight Ship · MISLE 228263 · 22 February 1997 · activity 108826MISS SHANNON Commercial Fishing Vessel · MISLE 200065 · 27 February 1995 · activity 12536

Inspection history · 47

15 September 2007 ISPS II Exam · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3058079
13 September 2007 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3057442
13 February 2007 COC-TVE Annual
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2871571
3 February 2007 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2866606
31 May 2006 Random ISPS/MTSA-No PSC
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2665882
20 May 2006 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2650752
24 February 2006 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2591611
16 February 2006 MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS III Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2586106
10 December 2005 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2560467
5 December 2005 Random ISPS/MTSA/PSC
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2546244
4 December 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2543175
15 July 2005 Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2427949
23 February 2005 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2297856
22 February 2005 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2297301
20 February 2005 COC-TVE Annual · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2295950
15 February 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2293030
17 February 2004 Certificate of Compliance · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2008086
30 March 2003 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1766842
10 February 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1742829
15 October 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1694432
10 May 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1615823
20 February 2002 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1487640
3 November 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 21675
2 January 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 285722
2 January 2001 Tank Vessel Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1056987
2 January 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 273386
11 October 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 421562
9 October 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 421308
14 July 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 406249
24 February 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 400939
22 February 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 108826
15 May 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 391107
2 December 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 385435
18 April 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 377311
27 February 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 12536
19 May 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 366870
19 May 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 860301
12 May 1994 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1169758
29 April 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 692535
25 March 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 146633
18 March 1994 Tank Vessel Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1164872
26 January 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 364008
17 August 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 360220
11 August 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 359810
26 May 1993 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 839011
7 April 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 357485
1 April 1993 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1147975

Deficiency record · 19

Construction/Loadline › Markings › Load Line Mark
Issued 13 February 2007 Resolved
Loadline needs to be ICLL 66 permanently marked in accordance with the International Loadline Certificate. Rectify deficiency prior to loading cargo assigned to that loadline, to the satisfaction of the administration.
Action required: 705 - Other - as specified
Due 15 May 2007
Resolved 16 September 2007
Resolution: Inspection of Load Line revealed a center punch had been used to outline markings accordingly, and painted in a contrasting color.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 23 February 2005 Resolved
Conduct repairs and full function test of the Port Anchor Windlass. See attached class report.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 May 2005
Resolved 15 July 2005
Resolution: Received class report from DNV satisfying requirement.
Deck/Cargo › Crude Oil Washing Systems › Crude Oil Washing Machine
Issued 20 February 2005 Resolved
Tank washing machine No. 8 forward is not properly afixed to the butterworth opening, allowing IG and cargo vapors to vent onto the open deck. Immediately effect temporary repairs with non-sparking tools and materials to stop the the release of these hazardous vapors.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2005
Resolved 21 February 2005
Resolution: A soft patch and sealant were applied to the defective flange. Class to propose proper repairs prior to departure.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 20 February 2005 Resolved
IGG O2 anylizer not capable of being properly calibrated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2005
Resolved 21 February 2005
Resolution: Vessel engineer cleared liquid in sample line. MI observed proper calibration of anylizer.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 20 February 2005 Resolved
MSD chlorinator tubes found empty. No chlorine tablets on board. Vessel ordered to retain all waste water onboard until the approved MSD can be operated as designed.
Condition: Improper/Lack of Maintenance
Due 21 February 2005
Resolved 21 February 2005
Resolution: Chlorine tablets arrived on board and MSD now operated properly to the satisfaction of attending MI.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 15 February 2005 Resolved
The subject vessel reported a malfunction to its port anchor windlass resulting in an inability to lower and raise the vessel's port anchor. The uncertainty of the satisfactory operating condition of the vessel's anchor system poses a potential navigation hazard to the Port of New York.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2005
Resolution: The vessel submitted a causal analysis report identifying the problem with the anchor windless failure.
Deck/Cargo › Cargo Stowage › General
Issued 15 February 2005 Resolved
However, the vessel is restricted from carrying further liquid cargo in U. S. waters until the temporarily repaired flange to the No. 8 forward crude oil wash (cow) machine has been permanently repaired to the satisfaction of the vessel's classification society, and a report that verifies these repairs have been completed, is received by the U. S. Coast Guard.
Action required: 705 - Other - as specified
Due 31 March 2005
Resolved 15 July 2005
Resolution: Received class report from DNV satisfying requirement.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 15 October 2002 Resolved
Vsl was issued a Letter of Deviation to enter the Port of Corpus Christi with an inoperable automatic radar (33 CFR 164.38(b)(1).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2002
Resolution: Rec''d faxed service report from technician (Litton Marine Systems) attesting to satisfactory repairs/operation of automatic radar.
Lifesaving
Issued 2 January 2000 Resolved
Prior to departure from port, provide proof of inspection of all liferafts to the satisfaction of the OCMI.
Condition: Unknown
Due 31 January 2000
Resolved 18 January 2000
Deck/Cargo
Issued 15 May 1996 Resolved
UPDATE OIL TRANSFER PROCEDURES TO INCLUDE PROCEDURES FOR HIGH LEVEL AND OVERFLOW ALARM OPERATIONS. 33 CFR 155.750
Condition: Unknown
Due 24 June 1996
Resolved 24 June 1996
Deck/Cargo
Issued 15 May 1996 Resolved
STENCIL CARGO MANIFOLD WITH THE WORD "VAPOR" ON THE VAPOR CONTROL SYSTEM PIPING.
Condition: Unknown
Due 15 May 1996
Resolved 21 May 1996
Deck/Cargo
Issued 15 May 1996 Resolved
CONDUCT AND PROVIDE DOCUMENTATION TO HYDROSTATICALLY TEST CARGO PIPING SYSTEM TO ONE AND A HALF TIMES THE MAWP. 33 CFR 156.170 (c)
Condition: Unknown
Due 24 June 1996
Resolved 24 June 1996
Documentation
Issued 18 March 1994 Resolved
PRIOR TO NEXT U. S. PORT, PROVIDE "OIL DISCHARGE PROHIBITED" PLACARD IN CARGO CONTROL ROOM.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Deck/Cargo
Issued 18 March 1994 Resolved
AT NEXT U. S. PORT, PROVE PROPER OPERATION OF INERT GAS SYSTEM TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Deck/Cargo
Issued 18 March 1994 Resolved
AT NEXT U. S. PORT, PROVE PROPER OPERATION OF CARGO PUMP EMERGENCY SHUT- DOWN IN THE PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Deck/Cargo
Issued 18 March 1994 Resolved
PRIOR TO NEXT U. S. PORT, AMEND OIL TRANSFER PROCEDURES AS PER _x001C_ 33 CFR 155.750.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Accommodation/Occupational Safety
Issued 18 March 1994 Resolved
NEXT U. S. VOYAGE, PROVIDE DOCUMENTATION TO THE COGNIZANT OCMI/COTP THAT HAMWORTHY SUPERTINDENT SEWAGE TREATMENT UNIT IS IN COMPLIANCE WITH 33 CFR 159.7, IS CERTIFICATED UNDER 33 CFR 159.12 AND HAS A LABELO ON THE MSD PER 33 CFR 159.16.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Documentation
Issued 1 April 1993 Resolved
DRAFT/DEVELOP A VESSEL RESPONSE PLAN AND SUBMIT SAME TO COMMANDANT _x001C_ (G-MEP-6) FOR APPROVAL. A COPY OF THE REQUIRED SECTIONS OF THE VESSEL RESPONSE PLAN SHALL BE PLACED/MAINTAINED ONBOARD THE VESSEL AFTER DEVELOPMENT PENDING FINAL COAST GUARD APPROVAL.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Lifesaving
Issued 1 April 1993 Resolved
DEVELOP AND PLACE A COPY OF OIL TRANSFER PROCEDURES ONBOARD THE VESSEL PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993

Ownership record