Records from 1993 to 2006. Most recent: inspection, 4 August 2006.
Inspection history · 18
4 August 2006
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2735721
21 May 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2654467
3 February 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2578851
26 January 2006
Type not recorded
No type recorded · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 2573680
25 January 2006
Deficiency Check
Physical examination · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 2573939
23 January 2006
NPV Safety Exam · ISPS II Exam
Physical examination · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 2573139
22 January 2006
Type not recorded
No type recorded · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 2573147
1 December 2005
Deficiency Check
Physical examination · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 2543812
6 September 2005
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2485535
18 July 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 418991
5 March 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 413513
20 February 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 687654
19 February 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 412908
13 January 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 726332
7 January 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 411802
5 January 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 23212
9 December 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 486635
2 April 1993
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 357306
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 23 January 2006
Resolved
Vsl had minor cracking in vicinity of aft port quarter about 1 1/2 meter above the water line which allowed very minor fuel leakage from vsl's fuel oil storage tank. This has created an unsafe condition. The vsl is required to provide written proposal to the COTP which details the to be followed to effect permanent repairs to this cracking in the hull. It must be approved by Class also.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2006
Resolution: Vsl submiited plan and had tank gas freed and commercial welders make repairs to crack in day tank. Class society rep was present during entire evolution and submitted attestaion report to the COTP. See scanned documents for more info.
Documentation › Logs/Records › Enhanced Survey Report File
Issued 23 January 2006
Resolved
Prior to vsl resuming commercial operations, or departure from current location the vsl shall provide written class society report detailing measures taken to effect repairs, and assessment of the vsl's condition to continue on it's intended route and service.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2006
Resolution: Class attended vsl and provided all information as per requested. See scanned documents of received documents from Class and Vsl and Insurance co.
Navigation
Issued 19 February 1998
Resolved
CONDUCT AND LOG EMERGENCY STEERING DRILL WITHIN 48 HOURS OF ENTRERING NEXT U.S. PORT AS REQUIRED BY 33 CFR 164.25
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Fire Fighting
Issued 19 February 1998
Resolved
PROVIDE BOLTS FOR INTERNATIONAL SHORE CONNECTION IAW SOLAS 74 II-2/19 PRIORTO NEXT U.S. PORT.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 19 February 1998
Resolved
CHANGE SHIPS NAME ON MUSTER LISTS TO REFLECT "SOPHIE" IAW SOLAS 74 III/53.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Navigation
Issued 19 February 1998
Resolved
LOG PREARRIVAL TESTS IN SHIPS LOG WITHIN 12 HOURS OF ENTERING NEXT U.S. PORT AS REQUIRED BY 33 CFR 164.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Navigation
Issued 19 February 1998
Resolved
OBTAIN CHART 11417 OR BA CHARTS 3847 AND 3848 PRIOR TO DEPARTING.
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Fire Fighting
Issued 19 February 1998
Resolved
SHOW PROPER LOCATION OF INTERNATIONAL SHORE CONNECTION ON FIRE CONTROL PLANIAW SOLAS 74 II-2/20.1 PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Documentation
Issued 7 January 1998
Resolved
Vessel's Oil transfer procedures incomplete.
Condition: Unknown
Due 7 January 1998
Resolved 13 January 1998
Navigation
Issued 7 January 1998
Resolved
Vessel missing Tide Table Volume 2.
Condition: Unknown
Due 10 January 1998
Resolved 13 January 1998
Navigation
Issued 7 January 1998
Resolved
The Agent, Seagull Marine Inc, on behalf of the vessel, failed to report the vessel operating with one engine down on the vessel arrival notice.
Condition: Unknown
Due 7 January 1998
Resolved 13 January 1998
Navigation
Issued 7 January 1998
Resolved
Vessel's gyro compass repeaters on both bridge wings were greater than 100 degrees out of alignment with main gyro. The repeaters must be maintained in alignment as required by 33 CFR 164.11.
Condition: Unknown
Due 10 January 1998
Resolved 13 January 1998
Navigation
Issued 7 January 1998
Resolved
Vessel's maneuvering information missing required warning label.
Condition: Unknown
Due 10 January 1998
Resolved 13 January 1998