Records from 1982 to 2023. Most recent: inspection, 2 August 2023.
Inspection history · 61
2 August 2023
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7758491
10 August 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7529628
2 June 2021
Internal Structural Exam · Hull Examination · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7213011
14 May 2020
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6953023
21 June 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6720868
31 May 2019
Drydock Exam · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6699109
13 August 2018
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6507155
8 August 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6215004
21 June 2016
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5933394
1 June 2016
Internal Structural Exam · Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5894075
12 June 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4886235
2 June 2014
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4874311
18 December 2008
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3376177
9 June 2008
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3233844
4 December 2007
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3109178
2 May 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3268524
7 April 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2903429
16 February 2007
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2873060
25 January 2007
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2861686
24 July 2006
Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2723214
21 February 2006
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2589111
13 February 2006
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2584526
27 September 2005
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2502507
9 November 2004
Examination of Repairs · Internal Structural Exam · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2237332
4 November 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1941958
25 November 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1711544
3 August 2001
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366446
3 March 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 104317
15 August 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382004
2 August 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 692486
9 July 1999
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452535
12 May 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 183044
12 May 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 222491
7 August 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 766567
22 June 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470154
23 February 1998
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383783
21 February 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 202008
13 January 1998
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1115703
5 January 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 23212
7 July 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465925
24 June 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1087340
14 June 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405926
20 June 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422527
10 June 1994
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412634
21 April 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1167692
24 September 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 939568
3 July 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362638
6 May 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370476
9 May 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 923398
8 May 1990
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1225716
14 December 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1212367
18 May 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 970852
8 January 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1241134
6 May 1988
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1042513
14 May 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1334737
22 December 1986
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1028372
16 June 1986
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 997596
5 September 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992298
19 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284918
8 December 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 969424
5 February 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277940
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 August 2023
Resolved
MACHINERY CAPABLE OF INJURY SHALL BE PROVIDED WITH ADEQUATE GUARDS. FOUND ROTATING PTO ON STBD GEN UNGUARDED. REPAIR/REPLACE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2023
Resolved 21 August 2023
Resolution: Replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2023
Resolved
ELECTRICAL INSTALLATIONS ON VESSELS MUST ENSURE PROTECTION OF PERSONNEL FROM HAZARDS. FOUND EXTENSIVE LOOSE WIRING UNDER HELM CONSOLE; REPAIR/REPLACE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2023
Resolved 21 August 2023
Resolution: Removed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 August 2023
Resolved
MACHINERY CAPABLE OF INJURY SHALL BE PROVIDED WITH ADEQUATE GUARDS. FOUND WASTED COVER ON JACKET WATER RESEVOIR TANK. REPAIR/REPLACE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2023
Resolved 21 August 2023
Resolution: Replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 August 2023
Resolved
MACHINERY CAPABLE OF INJURY SHALL BE PROVIDED WITH ADEQUATE GUARDS. FOUND WASTED PIPING ON HOT WATER HEATER OUTLET. REPAIR/REPLACE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2023
Resolved 21 August 2023
Resolution: Replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 August 2022
Resolved
The general construction of the vessel shall be as such to minimize fire hazards.
Fuel leak on the sentinel valve on the STBD MDE. Excessive fuel in the engine room bilge.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 August 2022
Resolved 15 August 2022
Resolution: The leaking sentinel valve was replaced by Diesel tech and testes sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 10 August 2022
Resolved
The bulkhead in the machinery space of each OSV must be watertight.
The overhead in the engine room had a leak that had temporary repair. Permanent repair required. Emergency escape hatch in engine room was not water tight.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2022
Resolved 12 August 2022
Resolution: Witnessed NDT on deck insert and verified hatch gasket.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 August 2022
Resolved
Circuit breakers required on switchboard. Circuit breaker switch is cracked on main switch board. Port aft circuit breaker panel was missing blank.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2022
Resolved 12 August 2022
Resolution: Added blanks to the circuit breaker.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 August 2022
Resolved
Wiring must be supported to prevent damage.
Wiring for navigation equipment on the outside of the pilot house was not supported.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2022
Resolved 12 August 2022
Resolution: Verified wire supports installed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 August 2022
Resolved
Suitable guards must be installed in dangerous places.
Lagging was missing from starboard main engine.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2022
Resolved 12 August 2022
Resolution: Verified lagging replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 August 2022
Resolved
Emergency lighting shall be available at all times crew are aboard the vessel.
02 emergency lighting in engine room were inoperable
Action required: 10 - Deficiency Rectified
Due 10 August 2022
Resolved 10 August 2022
Resolution: Crew replaced the battery in one of the light and the bulb on the other light.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 August 2022
Resolved
Each section of fire hose must conform to UL 19 standard.
Fire hose in the engine room had leak at the connection point.
Action required: 10 - Deficiency Rectified
Due 10 August 2022
Resolved 10 August 2022
Resolution: Crew replaced damaged fire hose with a new hose.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 June 2021
Resolved
The emergency lighting required by paragraph (a) of this section must automatically actuate upon failure of the main lighting; Emergency light in the main engine room passageway leading up to main accommodations area was inoperable.
Action required: 10 - Deficiency Rectified
Resolved 23 June 2021
Resolution: Retested emegency light prior to departing the vessel and confirmed its operability
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 June 2021
Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead-front type; Switchboard in the engine room had an exposed opening.
Action required: 10 - Deficiency Rectified
Resolved 23 June 2021
Resolution: Prior to the end of the inspection, a new blank was installed on the switchboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 June 2019
Resolved
Renew supply fuel/oil hoses on both main diesel engines. Complete to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2019
Resolved 21 June 2019
Resolution: Hoses were renewed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 June 2019
Resolved
Provide new hardware for securing the port side of the mast to guidewire. Corrected to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2019
Resolved 21 June 2019
Resolution: Guidewire to mast attach point was refabricated and made anew.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2019
Resolved
Provide cotter pins to the identified securing points of the steering system as intended by engineered design. Completed to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2019
Resolved 21 June 2019
Resolution: All cotter pins were installed as system intended.
Engineering › Fuel Oil Service System › Valve
Issued 8 August 2017
Resolved
While testing the remote fuel shutdown, the cable connected to the fuel line valve parted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2017
Resolution: New cable was purchased and replaced. Tested satisfactorily
Stability › Watertight Integrity › General
Issued 8 August 2017
Resolved
Watertight bulkhead penetrations were not properly sealed. Pipe penetration on port side of W/T door between E/R and passageway as well as cable penetrations on stbd side of same door.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2017
Resolution: Crew had packing material on hand and made repairs.
Engineering › Pressure Vessel › Pressure Gauge
Issued 21 June 2016
Resolved
The upper limit on both air receiver pressure gauges is not between 1.2 and 2 times the relief valve setting as required by 46 CFR 54.15-5(f). Replace air receiver pressure gauges with gauges having an upper limit between 210 – 350 psi.
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 21 July 2016
Resolution: Installed pressure gauges complying with 46 CFR 54.15-5.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 12 June 2014
Resolved
Generator overspeeds on both generators were inop. Neither overspeed went off before 115%. Required vessel to service, replace, or repair overspeeds to allow for proper function. To be cleared by an attending marine inspector prior to sail.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2014
Resolution: CIV Landry attended vessel and verified proper operation of both generator overspeeds. All sat. Cleared 835.
Electrical › Electrical Distribution System (service) › Cable
Issued 12 June 2014
Resolved
Vessel has had numerous wiring and cables installed that are not properly supported horizontally every 24" with metal supports. Vessel to properly support wires and have installations verified by an attending marine inspector within 7 days.
Condition: Improper Installation
Due 18 June 2014
Resolved 13 June 2014
Resolution: CIV Landry attended vessel and verified all wiring and cable was supported as required evey 24". All sat. Cleared 835.
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 December 2008
Resolved
Demonstrate proper operation of emergency Fuel stop.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2009
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 18 December 2008
Resolved
Demonstrate proper operation of Rudder angle indicator
Due 28 December 2008
Resolved 6 June 2011
Electrical › Electrical Distribution System (service) › Cable
Issued 18 December 2008
Resolved
Remove unapproved electrical wiring from under console at operation station.
Due 28 December 2008
Resolved 19 December 2008
Documentation › Logs/Records › Logbook (official)
Issued 18 December 2008
Resolved
Make proper entries into offficial log book iaw 46 cfr 97.35-3 and 97.35-5. To be inspected at next re-inspection of COI
Action required: 705 - Other - as specified
Resolved 6 June 2011
Engineering › Fuel Oil Service System › Filter
Issued 4 December 2007
Resolved
Insert plugs in all fuel filter drains/petcocks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2007
Engineering › Fuel Oil Service System › Piping
Issued 4 December 2007
Resolved
Repair leaking fuel service piping at the stbd MDE fuel filter connection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2007
Lifesaving › Hand Flares › Not on Board
Issued 4 December 2007
Resolved
Replace one missing red flare for a total of twelve combined flares.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2007
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 4 December 2007
Resolved
Provide a proper non-conducting mat in front of the electrical distribution panel in the e/r/.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2007
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 4 December 2007
Resolved
Provide required alcohol test strips for onboard crew testing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 13 February 2006
Resolved
Failure to secure Type III MSD prior to operating in area where the discharge of untreated sewage is prohibited by EPA.
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 21 February 2006
Resolution: Provide chain with lock. Valve secured.
Engineering › Fuel Oil Service System › Tank
Issued 13 February 2006
Resolved
Repair fuel leak iwo fuel starboard fuel tank. Unable to locate location of leak due to ventalation trunk.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2006
Resolution: Repaired
Engineering › Steering Gear System › Rudder
Issued 16 December 2004
Resolved
Adjust steering system to avoid hitting port rudder stop.
Action required: 705 - Other - as specified
Due 16 January 2005
Resolved 17 December 2004
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 16 December 2004
Resolved
Make corrections and provide updated fire control plan for approval.
Action required: 705 - Other - as specified
Due 16 January 2005
Resolved 17 December 2004
Lifesaving › Buoyant Apparatus
Issued 4 November 2003
Resolved
Have 12 man life float serviced. LEGACY COMPONENT DESC: Service
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2003
Resolved 5 November 2003
Communications › Radio Communications
Issued 4 November 2003
Resolved
Provide new antennae for EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 4 December 2003
Resolved 5 November 2003
Lifesaving › Lifebuoys
Issued 4 November 2003
Resolved
Renew life ring on starboard side of vessel's aft deck. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2003
Resolved 5 November 2003
Engineering › Fuel Oil Service System
Issued 4 November 2003
Resolved
Provide handles for Raycor filters on port main engine. LEGACY COMPONENT DESC: Valve
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2003
Resolved 5 November 2003
Electrical › Lighting (emergency)
Issued 4 November 2003
Resolved
Adjust battle lantern at engine room ladder. LEGACY COMPONENT DESC: Battery Operated Lantern
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2003
Resolved 5 November 2003
Fire Fighting › Fire Pumps › Power Source
Issued 25 November 2002
Resolved
RENEW FIRE PUMP MOTOR.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 December 2002
Resolved 26 November 2002
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 25 November 2002
Resolved
PROVIDE METALLIC BOWL FOR RACOR FILTER FOR PORT GENERATOR.
Due 25 December 2002
Resolved 26 November 2002
Electrical › Lighting (service) › Lighting Fixture
Issued 25 November 2002
Resolved
REPAIR LIGHT FIXTURE IN PASSAGEWAY TO ENGINEROOM.
Due 25 December 2002
Resolved 26 November 2002
Engineering
Issued 14 June 1996
Resolved
PROVE PROPER OPERATION OF PORT AND STARBOARD MDE OVERSPEEDS.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Deck/Cargo
Issued 6 May 1992
Resolved
MAKE REPAIRS AND PROVE OPERATION OF ANCHOR WINCH.
Condition: Unknown
Due 6 May 1992
Resolved 6 May 1992
Documentation
Issued 6 May 1992
Resolved
PLACE CURRENT CERTIFICATE OF DOCUMENTATION ONBOARD VESSEL.
Condition: Unknown
Due 6 May 1992
Resolved 6 May 1992
Navigation
Issued 8 May 1990
Resolved
REINSTALL RUDDER ANGLE INDICATORS FOR PILOT HOUSE AND AFT STEERING STATIONS.
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Unknown
Issued 8 May 1990
Resolved
REPAIR MAIN ENGINE OVERSPEEDS AND GENERATOR OVERSPEEDS PER ABS RULE 34.11.6
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Engineering
Issued 14 December 1989
Resolved
REPLACE PLASTIC RACOR FILTER PETCOCKS WITH STEEL PETCOCKS.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Engineering
Issued 14 December 1989
Resolved
REMOVE OR REPLACE PLASTIC SIGHT GLASSES ON ENGINE ROOM LUBE OIL SYSTEM WITH GLASS SIGHT GLASSES.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Accommodation/Occupational Safety
Issued 14 December 1989
Resolved
MAKE GALLEY AND ENGINE ROOM EMERGENCY LIGHTS OPERATIONAL.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989