LEADER is a 1980 offshore supply vessel. The Coast Guard has recorded 61 inspections since 1982, most recently in August 2023, along with 50 deficiencies and 3 casualty investigations between 2006 and 2013.

Records from 1982 to 2023. Most recent: inspection, 2 August 2023.

Built
1980
Last inspected
2 August 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH8342
Flag
UNITED STATES
367012480, 367110440 (licence lapsed)
Maury page id
psix-51269

Inspections, by type

…with no type recorded14
Years with a record 35 calendar years (1982–2023)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDH8342MMSI 367110440 · expired · compulsorily equipped · granted 12 February 2015, cancelled 19 April 2025
WDD2064MMSI 367110440 · cancelled · compulsorily equipped · granted 29 April 2006, cancelled 6 February 2015
WDC3685MMSI 367012480 · expired · voluntarily equipped · granted 20 January 2005, cancelled 28 March 2015
WCY5596MMSI not assigned · expired · voluntarily equipped · granted 4 August 1999, cancelled 20 September 2008
WCW6804MMSI not assigned · expired · voluntarily equipped · granted 19 June 1996, cancelled 19 August 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GULF JUSTICE Industrial Vessel · MISLE 49525 · 7 April 2007 · activity 2903429TESLA Passenger (Inspected) · MISLE 52158 · 7 April 2007 · activity 2903429SOPHIE Freight Ship · MISLE 386814 · 5 January 1998 · activity 23212

Inspection history · 61

2 August 2023 Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7758491
10 August 2022 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7529628
2 June 2021 Internal Structural Exam · Hull Examination · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7213011
14 May 2020 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6953023
21 June 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6720868
31 May 2019 Drydock Exam · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6699109
13 August 2018 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6507155
8 August 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6215004
21 June 2016 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5933394
1 June 2016 Internal Structural Exam · Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5894075
12 June 2014 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4886235
2 June 2014 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4874311
18 December 2008 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3376177
9 June 2008 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3233844
4 December 2007 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3109178
2 May 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3268524
7 April 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2903429
16 February 2007 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2873060
25 January 2007 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2861686
24 July 2006 Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2723214
21 February 2006 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2589111
13 February 2006 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2584526
27 September 2005 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2502507
9 November 2004 Examination of Repairs · Internal Structural Exam · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2237332
4 November 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1941958
25 November 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1711544
3 August 2001 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366446
3 March 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 104317
15 August 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382004
2 August 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 692486
9 July 1999 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452535
12 May 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 183044
12 May 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 222491
7 August 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 766567
22 June 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470154
23 February 1998 Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383783
21 February 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 202008
13 January 1998 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1115703
5 January 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 23212
7 July 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465925
24 June 1996 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1087340
14 June 1996 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405926
20 June 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422527
10 June 1994 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412634
21 April 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1167692
24 September 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 939568
3 July 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362638
6 May 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370476
9 May 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 923398
8 May 1990 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1225716
14 December 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1212367
18 May 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 970852
8 January 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1241134
6 May 1988 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1042513
14 May 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1334737
22 December 1986 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1028372
16 June 1986 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 997596
5 September 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992298
19 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284918
8 December 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 969424
5 February 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277940

Deficiency record · 50

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 August 2023 Resolved
MACHINERY CAPABLE OF INJURY SHALL BE PROVIDED WITH ADEQUATE GUARDS. FOUND ROTATING PTO ON STBD GEN UNGUARDED. REPAIR/REPLACE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2023
Resolved 21 August 2023
Resolution: Replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2023 Resolved
ELECTRICAL INSTALLATIONS ON VESSELS MUST ENSURE PROTECTION OF PERSONNEL FROM HAZARDS. FOUND EXTENSIVE LOOSE WIRING UNDER HELM CONSOLE; REPAIR/REPLACE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2023
Resolved 21 August 2023
Resolution: Removed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 August 2023 Resolved
MACHINERY CAPABLE OF INJURY SHALL BE PROVIDED WITH ADEQUATE GUARDS. FOUND WASTED COVER ON JACKET WATER RESEVOIR TANK. REPAIR/REPLACE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2023
Resolved 21 August 2023
Resolution: Replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 August 2023 Resolved
MACHINERY CAPABLE OF INJURY SHALL BE PROVIDED WITH ADEQUATE GUARDS. FOUND WASTED PIPING ON HOT WATER HEATER OUTLET. REPAIR/REPLACE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2023
Resolved 21 August 2023
Resolution: Replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 August 2022 Resolved
The general construction of the vessel shall be as such to minimize fire hazards. Fuel leak on the sentinel valve on the STBD MDE. Excessive fuel in the engine room bilge.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 August 2022
Resolved 15 August 2022
Resolution: The leaking sentinel valve was replaced by Diesel tech and testes sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 10 August 2022 Resolved
The bulkhead in the machinery space of each OSV must be watertight. The overhead in the engine room had a leak that had temporary repair. Permanent repair required. Emergency escape hatch in engine room was not water tight.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2022
Resolved 12 August 2022
Resolution: Witnessed NDT on deck insert and verified hatch gasket.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 August 2022 Resolved
Circuit breakers required on switchboard. Circuit breaker switch is cracked on main switch board. Port aft circuit breaker panel was missing blank.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2022
Resolved 12 August 2022
Resolution: Added blanks to the circuit breaker.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 August 2022 Resolved
Wiring must be supported to prevent damage. Wiring for navigation equipment on the outside of the pilot house was not supported.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2022
Resolved 12 August 2022
Resolution: Verified wire supports installed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 August 2022 Resolved
Suitable guards must be installed in dangerous places. Lagging was missing from starboard main engine.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2022
Resolved 12 August 2022
Resolution: Verified lagging replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 August 2022 Resolved
Emergency lighting shall be available at all times crew are aboard the vessel. 02 emergency lighting in engine room were inoperable
Action required: 10 - Deficiency Rectified
Due 10 August 2022
Resolved 10 August 2022
Resolution: Crew replaced the battery in one of the light and the bulb on the other light.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 August 2022 Resolved
Each section of fire hose must conform to UL 19 standard. Fire hose in the engine room had leak at the connection point.
Action required: 10 - Deficiency Rectified
Due 10 August 2022
Resolved 10 August 2022
Resolution: Crew replaced damaged fire hose with a new hose.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 June 2021 Resolved
The emergency lighting required by paragraph (a) of this section must automatically actuate upon failure of the main lighting; Emergency light in the main engine room passageway leading up to main accommodations area was inoperable.
Action required: 10 - Deficiency Rectified
Resolved 23 June 2021
Resolution: Retested emegency light prior to departing the vessel and confirmed its operability
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 June 2021 Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead-front type; Switchboard in the engine room had an exposed opening.
Action required: 10 - Deficiency Rectified
Resolved 23 June 2021
Resolution: Prior to the end of the inspection, a new blank was installed on the switchboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 June 2019 Resolved
Renew supply fuel/oil hoses on both main diesel engines. Complete to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2019
Resolved 21 June 2019
Resolution: Hoses were renewed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 June 2019 Resolved
Provide new hardware for securing the port side of the mast to guidewire. Corrected to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2019
Resolved 21 June 2019
Resolution: Guidewire to mast attach point was refabricated and made anew.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2019 Resolved
Provide cotter pins to the identified securing points of the steering system as intended by engineered design. Completed to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2019
Resolved 21 June 2019
Resolution: All cotter pins were installed as system intended.
Engineering › Fuel Oil Service System › Valve
Issued 8 August 2017 Resolved
While testing the remote fuel shutdown, the cable connected to the fuel line valve parted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2017
Resolution: New cable was purchased and replaced. Tested satisfactorily
Stability › Watertight Integrity › General
Issued 8 August 2017 Resolved
Watertight bulkhead penetrations were not properly sealed. Pipe penetration on port side of W/T door between E/R and passageway as well as cable penetrations on stbd side of same door.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2017
Resolution: Crew had packing material on hand and made repairs.
Engineering › Pressure Vessel › Pressure Gauge
Issued 21 June 2016 Resolved
The upper limit on both air receiver pressure gauges is not between 1.2 and 2 times the relief valve setting as required by 46 CFR 54.15-5(f). Replace air receiver pressure gauges with gauges having an upper limit between 210 – 350 psi.
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 21 July 2016
Resolution: Installed pressure gauges complying with 46 CFR 54.15-5.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 12 June 2014 Resolved
Generator overspeeds on both generators were inop. Neither overspeed went off before 115%. Required vessel to service, replace, or repair overspeeds to allow for proper function. To be cleared by an attending marine inspector prior to sail.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2014
Resolution: CIV Landry attended vessel and verified proper operation of both generator overspeeds. All sat. Cleared 835.
Electrical › Electrical Distribution System (service) › Cable
Issued 12 June 2014 Resolved
Vessel has had numerous wiring and cables installed that are not properly supported horizontally every 24" with metal supports. Vessel to properly support wires and have installations verified by an attending marine inspector within 7 days.
Condition: Improper Installation
Due 18 June 2014
Resolved 13 June 2014
Resolution: CIV Landry attended vessel and verified all wiring and cable was supported as required evey 24". All sat. Cleared 835.
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 December 2008 Resolved
Demonstrate proper operation of emergency Fuel stop.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2009
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 18 December 2008 Resolved
Demonstrate proper operation of Rudder angle indicator
Due 28 December 2008
Resolved 6 June 2011
Electrical › Electrical Distribution System (service) › Cable
Issued 18 December 2008 Resolved
Remove unapproved electrical wiring from under console at operation station.
Due 28 December 2008
Resolved 19 December 2008
Documentation › Logs/Records › Logbook (official)
Issued 18 December 2008 Resolved
Make proper entries into offficial log book iaw 46 cfr 97.35-3 and 97.35-5. To be inspected at next re-inspection of COI
Action required: 705 - Other - as specified
Resolved 6 June 2011
Engineering › Fuel Oil Service System › Filter
Issued 4 December 2007 Resolved
Insert plugs in all fuel filter drains/petcocks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2007
Engineering › Fuel Oil Service System › Piping
Issued 4 December 2007 Resolved
Repair leaking fuel service piping at the stbd MDE fuel filter connection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2007
Lifesaving › Hand Flares › Not on Board
Issued 4 December 2007 Resolved
Replace one missing red flare for a total of twelve combined flares.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2007
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 4 December 2007 Resolved
Provide a proper non-conducting mat in front of the electrical distribution panel in the e/r/.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2007
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 4 December 2007 Resolved
Provide required alcohol test strips for onboard crew testing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 13 February 2006 Resolved
Failure to secure Type III MSD prior to operating in area where the discharge of untreated sewage is prohibited by EPA.
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 21 February 2006
Resolution: Provide chain with lock. Valve secured.
Engineering › Fuel Oil Service System › Tank
Issued 13 February 2006 Resolved
Repair fuel leak iwo fuel starboard fuel tank. Unable to locate location of leak due to ventalation trunk.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2006
Resolution: Repaired
Engineering › Steering Gear System › Rudder
Issued 16 December 2004 Resolved
Adjust steering system to avoid hitting port rudder stop.
Action required: 705 - Other - as specified
Due 16 January 2005
Resolved 17 December 2004
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 16 December 2004 Resolved
Make corrections and provide updated fire control plan for approval.
Action required: 705 - Other - as specified
Due 16 January 2005
Resolved 17 December 2004
Lifesaving › Buoyant Apparatus
Issued 4 November 2003 Resolved
Have 12 man life float serviced. LEGACY COMPONENT DESC: Service
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2003
Resolved 5 November 2003
Communications › Radio Communications
Issued 4 November 2003 Resolved
Provide new antennae for EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 4 December 2003
Resolved 5 November 2003
Lifesaving › Lifebuoys
Issued 4 November 2003 Resolved
Renew life ring on starboard side of vessel's aft deck. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2003
Resolved 5 November 2003
Engineering › Fuel Oil Service System
Issued 4 November 2003 Resolved
Provide handles for Raycor filters on port main engine. LEGACY COMPONENT DESC: Valve
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2003
Resolved 5 November 2003
Electrical › Lighting (emergency)
Issued 4 November 2003 Resolved
Adjust battle lantern at engine room ladder. LEGACY COMPONENT DESC: Battery Operated Lantern
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2003
Resolved 5 November 2003
Fire Fighting › Fire Pumps › Power Source
Issued 25 November 2002 Resolved
RENEW FIRE PUMP MOTOR.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 December 2002
Resolved 26 November 2002
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 25 November 2002 Resolved
PROVIDE METALLIC BOWL FOR RACOR FILTER FOR PORT GENERATOR.
Due 25 December 2002
Resolved 26 November 2002
Electrical › Lighting (service) › Lighting Fixture
Issued 25 November 2002 Resolved
REPAIR LIGHT FIXTURE IN PASSAGEWAY TO ENGINEROOM.
Due 25 December 2002
Resolved 26 November 2002
Engineering
Issued 14 June 1996 Resolved
PROVE PROPER OPERATION OF PORT AND STARBOARD MDE OVERSPEEDS.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Deck/Cargo
Issued 6 May 1992 Resolved
MAKE REPAIRS AND PROVE OPERATION OF ANCHOR WINCH.
Condition: Unknown
Due 6 May 1992
Resolved 6 May 1992
Documentation
Issued 6 May 1992 Resolved
PLACE CURRENT CERTIFICATE OF DOCUMENTATION ONBOARD VESSEL.
Condition: Unknown
Due 6 May 1992
Resolved 6 May 1992
Navigation
Issued 8 May 1990 Resolved
REINSTALL RUDDER ANGLE INDICATORS FOR PILOT HOUSE AND AFT STEERING STATIONS.
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Unknown
Issued 8 May 1990 Resolved
REPAIR MAIN ENGINE OVERSPEEDS AND GENERATOR OVERSPEEDS PER ABS RULE 34.11.6
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Engineering
Issued 14 December 1989 Resolved
REPLACE PLASTIC RACOR FILTER PETCOCKS WITH STEEL PETCOCKS.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Engineering
Issued 14 December 1989 Resolved
REMOVE OR REPLACE PLASTIC SIGHT GLASSES ON ENGINE ROOM LUBE OIL SYSTEM WITH GLASS SIGHT GLASSES.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Accommodation/Occupational Safety
Issued 14 December 1989 Resolved
MAKE GALLEY AND ENGINE ROOM EMERGENCY LIGHTS OPERATIONAL.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989

Casualty record · 3

2 December 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2832980
7 April 2007Routine · role: Involved in a Marine Casualty · activity 2903429
16 July 2013Routine · role: Involved in a Marine Casualty · activity 4654863
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.