Records from 2007 to 2022. Most recent: inspection, 27 October 2022.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 June 2020
Resolved
ALL PROPULSION MACHINERY MUST BE FREE OF ALL F/O LEAKS. STBD MDE HAS A F/O LEAK ON THE INBOARD #3 CYL. VSL MUST FIX F/O LEAK. 46 CFR 50.05-10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 June 2020
Resolved
GENSETS MUST NOT BE SUBJECTED TO WATER CONSTANT WATER DRIPAGE. PORT SSDG J/W EXPANSION TANK IS OVERFLOWING AND LEAKING DIRECTLY ONTO PORT GENSET. VSL MUST RECTIFY CAUSE OF RAPID EXPANSION. 46 CFR 111.50-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 June 2020
Resolved
PROPULSION ENGINES SHALL BE FREE OF ALL FLUID LEAKS. PORT MDE HAS A MRG L/O LEAK. VSL MUST FIX LEAK. 46 CFR 58.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 11 June 2020
Resolved
SERVICING RECORDS AND CRANE LOGS ARE REQUIRED TO BE MAINTAINED FOR ALL CARGO LOADING CRANES ONBOARD CERTIFICATED VESSELS. VSL DID NOT HAVE ANY DOCUMENTATION FOR ANY MAINTENANCE OR DAILY INSPECTIONS FOR CRANE. VSL MUST MAINTAIN SERVICE RECORDS AND DAILY INSPECTION AND OPERATION LOGS FOR CRANE. 46 CFR 91.25-259 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 June 2020
Resolved
RESCUE BOAT DAVIT MUST HAVE MAINTENNCE RECORDS AND DAILY INSPECTION LOG KEPT. VSL DOES NOT HAVE SERVICE RECORDS OR DAILY LOG OF INSPECTIONS. VSL MUST ESTABLISH AND MAINTAIN PROPER MAINTENANCE RECORDS AND DAILY INSPECTION LOGS FOR RESCUE BOAT DAVIT. 46 CFR 199.190
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 May 2020
Resolved
IN CARGO VESSELS WITH TWO OR MORE IDENTICAL POWER UNITS, THE MAIN STEERING GEAR MUST BE CAPABLE OF MOVING THE RUDDER FROM 35 DEGREES ON EITHER SIDE TO 35 DEGREES ON THEIR OTHER WITH THE VESSEL AT ITS DEEPEST LOADLINE DRAFT AND RUNNING AT MAXIMUM AHEAD SERVICE SPEED, AND FROM 35 DEGREES ON EITHER SIDE TO 30 ON THE OTHER SIDE IN NOT MORE THAN 28 SECONDS UNDER THE SAME CONDITIONS; ONE HYDRALIC STEERING PUMP WAS INOPERABLE DURING MI'S ATTENDANCE AND MUST BE BROUGHT INTO COMPLIANCE AS STATED. 46 CFR 58.25-10 (e) (2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2020
Resolution: Sat steering test done all pumps, all modes, all locations.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 21 May 2020
Resolved
RESCUE BOAT DAVITS ARE REQUIRED TO BE TESTED EVERY 5-YEARS. VSL'S RESCUE BOAT DAVIT WAS NOT TESTED IN THE PRESENCE OF A MARINE INSPECTOR. VSL MUST CONDUCT A STATIC AND DYNAMIC WEIGHT TEST OF THE RESCUE BOAT DAVIT IN THE PRESENCE OF A CG MARINE INSPECTOR. 46 CFR 199.160
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2020
Resolution: Davit test performed in the presence of an MI
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 21 May 2020
Resolved
DECK CRANES ARE REQUIRED TO BE WEIGHT TESTED EVERY 5-YEARS. VSL'S CRANE WAS NOT TESTED IN THE PRESENCE OF A MARINE INSPECTOR. VSL MUST CONDUCT A WEIGHT TEST OF THE CRANE IN THE PRESENCE OF A MARINE INSPECTOR. 46 CFR 107.258
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2020
Resolution: Crane test performed in the presence of an MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 May 2020
Resolved
FUEL OIL TRANSFER PUMPS SHOULD BE FREE OF ANY LEAKS. VSL #2 FUEL OIL TRANSFER PUMP IS LEAKING FUEL OIL. FUEL OIL TRANSFER PUMP MUST BE LEAK FREE IN ALL OPERATIONAL CONDITIONS. 46 CFR 61.01-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 May 2020
Resolved
WATERTIGHT DOORS LEADING TO INTERIOR OF MAIN DECK AND TO ENGINE ROOM HAD IMPROPERLY INSTALLED GASKETS; CREW TO INSTALL PROPER WATERTIGHT GASKETS TO ENSURE WATERTIGHT INTEGRITY. 46 CFR 170.270 (b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2020
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 21 May 2020
Resolved
THE GENERAL ARRANGEMENT AND PLANS IN 46CFR97.36.1 (C) SHALL BE KEPT UP-TO-DATE, ANY ALTERATION BEING RECORDED IN THE APPLICABLE MEDIUM AS SOON AS POSSIBLE; THE VESSEL'S FIRE CONTROL PLAN HAD MULTIPLE DISCREPANCIES AND ERRORS; MAKE CORRECTIONS PER 46CFR97.36-1(A); TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR. 46 CFR 97.36-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 21 May 2020
Resolved
LOAD LINE MARKINGS ARE REQUIRED TO BE PERMANENTLY MARKED ON VSL HULL VIA WELDMENTS OR PINGED MARKINGS. VSL DOES NOT HAVE LOAD LINE PERMENENTLY MARKED. VSL MUST PERMENENTLY MARK LOAD LINE TREE ON VSL HULL. 46 CFR 97.40
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2020
Resolved
LIFE RINGS MUST BE MAINTAINED IN SERVICEABLE CONDITION. LIEFERING ON PORT SIDE WAS FOUND TO BE NOT SERVICEABLE VSL MUST PROVIDE SERVICEABLE LIFE RING BUOY. 46 CFR 94.43
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 May 2020
Resolved
BATTERIES MUST BE SECURED. BATTERIES LOCATED AFT OF BRIDGE WERE NOT PROPERLY SECURED. VSL MUST PROPERLY SECURE BATTERIES. 46 CFR 111.15-5
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 May 2020
Resolved
FLEXIBLE HOSES MUST BE MAINTAINED IN ACCORDANCE WITH SAE J1942; FUEL SERVICE FLEX HOSES ON BOTH GENERATORS REQUIRE CHAFING GEAR TO ENSURE CONTINUED INTEGRITY. 46 CFR 56.60-25
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2020
Resolved
TWO 440V DISTRIBUTION PANELS, ONE LOCATED IN BOW THRUSTER AREA AND ONE LOCATED IN GALLEY, ARE NOT BEING MAINTAINED IN ACCORDANCE WITH IEE 45-2002; DISTRIBUTION CONTD. PANELS MUST BE MADE OF DEADFRONT TYPE. 46 CFR 111.40-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 May 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Fast Rescue Boats
Issued 15 March 2020
Resolved
STANDARD FAST RESQ BOAT MAY ONLY HAVE STANDARD OUTBOARD MOTORS INSTALLED. VSL HAD NON AUTHORIZED MERCURY 20 HP MOTOR WHICH DID NO PERFORM IAW LSA REQUIREMENTS. VSL MUST PROVIDE APPROVED OUTBOARD MOTOR WHICH PERFORMS IAW LSA REQURIEMENTS.
46 CFR 199.190
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2020
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 12 March 2020
No resolution recorded
COAST GUARD OR RO APPROVAL IS REQUIRED PRIOR TO THE INSTALLATION OF PORTABLE ACCOMMODATION MODULES (PAM). SUCH APPROVALS ARE REQUIRED TO BE MADE AVAILABLE TO THE COAST GUARD UPON REQUEST. VESSEL HAS TWO (2) PAMS INSTALLED ON THE MAIN CARGO DECK AND HAS BEEN UNABLE TO PROVIDE CONSTRUCTION APPROVALS, STRUCTURAL AND STABILITY EVALUATIONS, INSTALLATION APPROVALS OR INSTALLATION OVERSITE DOCUMENTATION OF SAID PAMS. VSL MUST PROVIDE THE AFOREMENTIONED DOCUMENTATION WITHIN 30 DAYS OR REMOVE THE PAMS. 46 CFR 91.25-50
Action required: 50 - Rectify deficiencies w/in 30 days
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 12 March 2020
No resolution recorded
EXISTING PORTABLE ACCOMMODATION MODULES (PAM) SHOULD BE MAINTAINED IAW SECTIONS 5B THROUGH 5D OF THE “POLICY” IN DISTRICT-8 POLICY LETTER 01-16 “PORTABLE ACCOMMODATIONS MODULE GUIDANCE”. VSL HAS TWO (02) EXISTING PAM INSTALLED ON THE MAIN CARGO DECK WHICH HAVE BEEN PURPOSELY MODIFIED TO ACCOMMODATE DIVE OPERATIONS, CONSEQUENTLY DEGRADING THE STRUCTURAL FIRE PROTECTION (SFP) OF THE PAM. VSL MUST MAINTAIN ALL EXISTING PAM IAW SECTIONS 5B THROUGH 5D OF THE “POLICY” IN DISRICT-8 POLICY LETTER 01-16 “PORTABLE ACCOMMODATIONS MODULE GUIDANCE”. 46 CFR 91.25-50
Action required: 50 - Rectify deficiencies w/in 30 days
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 November 2019
No resolution recorded
TEMPORARY WIRING BEING USED AS PERMANENT. VSL IS USING AN EXTENTION CORD TO POWER FREEZER IN GALLEY. VSL MUST PROVIDE PERMANENT WIRING FOR FREEZER. 46 CFR 111.60-13
Action required: 16 - Rectify deficiencies w/in 14 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 November 2019
No resolution recorded
FUEL SUPPLY FITTING MUST MEET ASTM F1201 (88) REAPPROVED 2010. PLASTIC BOWLS ARE INSTALLED IN FUEL FILTERS IN ENGINE COMPARTMENTS WHICH DO NOT MEET STANDARDS. VSL MUST PROVIDE FUEL WATER SEPERATING EQUIPMENT WHICH MEETS THE STANDARD.
46 CFR 56.60-1
Action required: 16 - Rectify deficiencies w/in 14 days
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 November 2019
No resolution recorded
SPLICED WIRING CONNECTIONS MUST BE MADE IN JUNCTION BOXES. JUNCTION BOX ABOVE BOW THRUSTER IS NOT SECURECD AND BATTERY CHARGER IN ENGINE ROOM HAS A SPLICE NOT IN A JUNCTION BOX. VSL MUST MAKE CONNECTIONS IN JUNCTION BOX. 46 CFR 111.60-11
Action required: 16 - Rectify deficiencies w/in 14 days
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 November 2019
No resolution recorded
WATERTIGHT DOORS MUST BE WATERTIGHT. ENGINE ROOM DOOR SEAL IS NOT SERVICEABLE. VSL MUST PROVIDE SERVICEABLE SEAL.
46 CFR 170.248
Action required: 16 - Rectify deficiencies w/in 14 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 November 2019
No resolution recorded
GROUND DETECTION REQUIRED. GROUND PRESENT 30 AMP 110 PANEL IN ENGINE ROOM. 46 CFR 111.05-21
Action required: 16 - Rectify deficiencies w/in 14 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 November 2019
No resolution recorded
PRESSURE VSL GAUGES ARE REQUIRED TO BE 1.2 TO 2 TIME THE SET PRESSURE OF THE RELIEF VALVE. THE GAUGE ON THE PORT AIR RECIEVER WAS 0-200 PSI. VSL MUST PROVIDE A GAUGE THAT COMPLIES WITH AN APPROPRATE SCALE. 46 CFR 54.15-5
Action required: 50 - Rectify deficiencies w/in 30 days
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 November 2019
No resolution recorded
HEAT DETECTOR ABOVE THE STBD GENERATOR IS INOPERABLE.
VSL MUST PROVIDE OPERABLE HEAT DETECTOR. 46 CFR 95.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 November 2019
No resolution recorded
GUARDS OR LAGGING MUST BE INSTALLED TO PREVENT BURNS ON SURFACES WHICH REACH TEMPERATURES IN EXCESS OF 150 DEGREES. VSL IS MISSING LAGGING ON STBD JACKET WATER PIPING.
46 CFR 92.25-15
Action required: 16 - Rectify deficiencies w/in 14 days
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 25 November 2019
No resolution recorded
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 November 2019
No resolution recorded
ALL ELECTRICAL INSTALLATION ON THE VSL MUST ENSURE MAINTENANCE OF SERVICES NECESSARY FOR SAFETY UNDER ALL CONDITIONS AND PROVIDE PROTECTION OF CREW FROM ELECTRICAL HAZARDS. MULTIPLE ELECTRICAL HAZARDS EXISTED ON THE BRIDGE INCLUDEING BROKEN OUTLETS WITH EXPOSED
WIRING, POOR CIRCUIT LABELING, MULTIPLE POWER STRIPS.
46 CFR 111.01-1
Action required: 17 - Rectify deficiencies prior to departure
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 November 2019
No resolution recorded
AT LEAST TWO LIFEBUOYS, EACH WITH SELF ACTIVATING SMOKE SIGNALS MUST BE STOWED WHERE THEY CAN BE QUICKLY RELEASED FROM THE NAVIGATING BRIDGE AND SHOULD, WHEN RELEASED, FALL DIRECTLY INTO THE WATER WITHOU STRIKING THE VSL. VSL DOES NOT HAVE BRIDGE BUOYS INSTALLED. VSL MUST PROVIDE TWO BRIDGE BUOYS WITH SMOKE MARKERS. 46 CFR 199.70
Action required: 50 - Rectify deficiencies w/in 30 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 September 2019
No resolution recorded
Nonmetallic flexible hoses must be fire rated iaw SAE J1942. F/O supply line for the bow thruster prime mover is cotton jacketed w/ no fire sleeve. VSL must provide proof that hose is fire rated. 46CFR56.60-25 (b) (1)
Action required: 50 - Rectify deficiencies w/in 30 days
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 September 2019
No resolution recorded
Portable fire extinguishers must be serviceable iaw NFPA 10. CO2 fire extinguisher located on messdeck has a cracked hose. VSL must provide serviceable fire extinguisher. 46CFR95.05-12
Action required: 50 - Rectify deficiencies w/in 30 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 September 2019
No resolution recorded
Nonmetallic flexible hoses must not exceed 30" in length. Both MDE F/O supply lines exceed 30" in length. VSL must arrange F/O supply system so nonmetallic fuel lines do not exceed 30" 46CFR56.60-25 (b) (4)
Action required: 50 - Rectify deficiencies w/in 30 days
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 September 2019
No resolution recorded
Emergency lighting lanterns must be provided for egress in the event of a loss of power. VSL has an inoperable emergency lighting lantern in the main passageway. VSL must provide a serviceable emergency lantern in the main passage way. 46CFR112.39-3 5.Cabling must be secured using metal retention bands or clamps. Iaw IEEE 45/2
Action required: 50 - Rectify deficiencies w/in 30 days
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 September 2019
No resolution recorded
Hi voltage cabling located in the engine room was secured using plastic zip ties. VSL must secure cabling with metal bands or clamps. 46CFR111.60-5
Action required: 50 - Rectify deficiencies w/in 30 days
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 13 September 2019
No resolution recorded
Grab rails must be installed on electric ranges iaw IEEE 45/19.1.1. Grab rails are currently not installed on range. VSL must properly install grab rails. 46CFR110.10-1
Action required: 50 - Rectify deficiencies w/in 30 days
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 13 September 2019
No resolution recorded
Electrical switchboards must be of the dead front type iaw IEEE 45/8.2. Engine room lighting panel face is not sufficiently secured. VSL must properly secure face of switchboard. 46CFR111.30-1
Action required: 50 - Rectify deficiencies w/in 30 days
Lifesaving › Rescue Boat › Propulsion Starting System
Issued 26 July 2017
Resolved
Each rescue boat must be ready for launching in not more than 5 minutes. The rescue boat on the vessel engined stalls when placed in gear.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2017
Resolution: Vessel crew demonstrated timely use of rescue boat without failure during drills.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 26 July 2017
Resolved
A Fixed CO2 System must be installed in paint locker. Vessel system wasted bracket on deck, system not attached.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2017
Resolution: Paint locker fixed CO2 system installed to satisfaction of attending marine inspector.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 26 July 2017
Resolved
Vessel must have an approved line throwing appliance under approval 160.040. 04 charges. All charges are expired. 2014
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2017
Resolution: Vessel purchased 4 new line throwing guns with charges.
Lifesaving › Lifebuoys › Stowage
Issued 26 July 2017
Resolved
At least 2 lifebuoys each with attached self activating smoke signals must be stowed where they can be quickly released, fall directly into the water without striking any part of the vessel. Must weigh 4kg per Q specs.
Condition: Improper Installation
Due 26 August 2017
Resolved 26 April 2018
Resolution: Resolved by act 6290260 IAW with narrative.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 26 July 2017
Resolved
Vessel must have at least one pump installed to discharge oily mixtures through a fixed piping system accessible from the weather deck with a stop valve at outlet. Vessel dirty oil pump not functioning.
Condition: Improper/Lack of Maintenance
Due 26 August 2017
Resolved 31 July 2017
Resolution: Vessel crew made satisfactory repairs to oily discharge pump to satisfaction of attending marine inspector.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 25 July 2017
Resolved
Employees must maintain a record of chemical testing as provided by 49 CFR 40.337 and must make records available to USCG upon request.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2017
Resolution: Company provided records of employees enrollment in an approved drug and alcohol program. Also provided record of drug and alchol testing with negative results.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 16 August 2016
Resolved
issue 835 for rescue boat obstruction to port side pilot house. Rescue boat did not have a review stuctural plans.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2016
Resolution: vsl rep was able to provide proper plan approved plans for stucture and documentation showing a davit test was complete in the last five years.
Stability › Weathertight Integrity › General
Issued 16 August 2016
Resolved
replace weather tight gaskets located on navigation bridge.
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 17 August 2016
Resolution: replaced gaskets
Engineering › Bilge Water Management System › Not Operational
Issued 5 August 2016
Resolved
Bow thruster tunnel bilge alarm not operating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2016
Resolved 16 August 2016
Personnel › Training › Personal Safety/Social Responsibilities
Issued 5 August 2016
Resolved
Post the muster list/ station bill
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 September 2016
Resolved 16 August 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 August 2016
Resolved
Rearrange equipment on the bridge/ add more current to the bridge in order to get rid of extension cords and power strips
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 September 2016
Resolved 16 August 2016
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 5 August 2016
Resolved
Placard for emergency instructions/ instructions for lowering the rescue boat need to be posted outside
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 September 2016
Resolved 16 August 2016
Lifesaving › Lifebuoys › Serviceable
Issued 5 August 2016
Resolved
Ring buoys need to have retro-reflective material replaced throughout the vessel
Condition: Improper/Lack of Maintenance
Due 16 September 2016
Resolved 17 August 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 August 2016
Resolved
Four navigation lights were not operating (upper top port side, upper and lower starboard side, and mast head light)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2016
Resolved 16 August 2016
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 5 August 2016
Resolved
All accommodation spaces were missing life jacket donning instruction placards (two different types of lifejackets were onboard; instructed the crew and captain that the placards need to be specific to the type of life jacket on board
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 September 2016
Resolved 16 August 2016
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 August 2016
Resolved
Vessel did not have Drug and Alcohol testing strips/equipment
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 September 2016
Resolved 16 August 2016
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 5 August 2016
Resolved
Three plugged but deteriorated penetration in the stores locker/collision bulkhead
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2016
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 5 August 2016
Resolved
Bunk lights not operating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2016
Resolved 16 August 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 August 2016
No resolution recorded
Port side running movement due to rescue boat obstruction blocking possible visibility.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 September 2016 — due date passed with no resolution recorded
Engineering › Steering Gear System › Rudder
Issued 13 July 2016
Resolved
Rudder was not assembled with correct nuts and bolts. Packing gland was missing a plate and shifting during rudder operation.
Condition: Improper Installation
Due 13 August 2016
Resolved 14 July 2016
Resolution: repair on steering gear; new plate added to starboard packing gland, new bolts, new nuts, and washers were added.