Records from 1993 to 2026. Most recent: inspection, 31 March 2026.
Documentation record
Registered dimensions (L × B × D)121.4 ft × 27.0 ft × 11.7 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)121.4 ft × 27.0 ft × 11.7 ft
ITC tonnagegross 250 / net 75
BuilderBREAUX BROS ENTERPRISES · LOREAUVILLE, LA, UNITED STATES · built 1993
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 31 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it250 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
75 - Convention (Subpart B), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 54
31 March 2026
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8327737
25 March 2025
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8097228
12 March 2025
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8092723
1 April 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7887000
28 February 2023
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7643343
8 February 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7634199
26 April 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7436091
7 April 2021
Annual Inspection · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7170172
16 December 2020
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7112635
15 December 2020
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7112835
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108437
13 April 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6948032
19 April 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6665913
1 April 2019
Administrative Inspection · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6653724
27 March 2018
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6379307
6 April 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6118628
30 March 2017
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6114645
14 June 2016
Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5907311
25 June 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4899485
26 July 2012
Administrative Inspection · Annual Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4391344
19 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4227777
26 March 2010
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3702295
7 July 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3526052
24 March 2009
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3434874
11 December 2008
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3378256
11 December 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3656910
29 April 2008
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3194788
7 April 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3179277
5 March 2007
Damage Survey · Re-Inspection · Hull Examination · Examination of Repairs · Internal Structural Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2881824
13 February 2007
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2871644
12 February 2007
Damage Survey · Examination of Repairs · Administrative Inspection · Permit to Proceed
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2871628
23 October 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806539
7 August 2006
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2739072
20 April 2005
Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2339149
12 May 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2065962
21 May 2003
COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1798137
12 June 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1629794
16 August 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1362394
30 June 2000
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423400
27 April 2000
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1048775
13 April 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 163192
13 April 2000
Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1050994
1 June 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423187
5 August 1998
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460219
9 July 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 778417
6 June 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1386011
6 September 1996
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1380639
7 June 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1359166
12 June 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 874447
9 June 1995
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1455271
5 April 1995
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 843298
3 February 1995
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1412755
16 June 1994
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1335898
17 June 1993
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1420784
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 February 2023
Resolved
Vessel must carry adequate and up to date charts.
Vessel has not corrected charts since April of 2022.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 March 2023
Resolution: Vessel purchased new charts for area of operation
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 February 2023
Resolved
Irrespective of build date, a vessel to which this subchapter applies must meet 46 CFR 181.405, 181.450, 181.500, 185.364, and 185.420(b), if it is not a ferry, and if it is operating on a Coastwise or Oceans route.
Propose plan and install fire detection system to the satisfaction of attending USCG Marine Inspector
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2023
Resolved 16 August 2023
Resolution: Received tech report for fire dectection and alarms installation/testing - Main deck, wheel house, bunk rooms, galley, engine and generator rooms.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 April 2022
Resolved
EPIRB tests are required to be conducted and logged monthly. EPIRB tests were only conducted and logged quarterly.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 April 2022
Resolved 26 April 2022
Resolution: Conducted training with vessel master on EPIRB testing and logging requirements.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 26 April 2022
Resolved
Rotating machinery must be protected by a cover, guard, or rail. Neither generator (two total) had rotating machinery guards in place.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2022
Resolved 26 April 2022
Resolution: Guards installed. (See Documents)
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 7 April 2021
Resolved
Each self-propelled vessel must have a navigation light indicator panel with audible and visual alarm. Visual alarm was not functioning on indicator panel. Vsl rep fixed deficiency on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 April 2021
Resolved 21 April 2021
Resolution: Vsl rep corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 April 2021
Resolved
Each life float must be fitted with a light. Life float did not have operational light. Vsl rep fixed deficiency on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 April 2021
Resolved 21 April 2021
Resolution: Vessl rep fixed on the spot
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 December 2020
Resolved
Repairs or alterations to the hull, machinery or equipment that affect the safety of the vessel must not be made with out the approval of the OCMI. Vessel sustained damage to the underwater body of the hull, repairs are to be inspected prior to departure from shipyard.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2020
Resolved 18 December 2020
Resolution: Vessel provided a captain witness statement attesting the dye penetration test passed. Vessel provided photographic evidence of the completed hull repair.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 6 April 2017
Resolved
Provide servicaeable fuel reach rod cable.
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 7 April 2017
Resolution: Pictures recieved, to include old, new reach rod. As well as recpit of purchase for new reach rod.
Communications › Radio Communications › EPIRB
Issued 14 June 2016
Resolved
EPIRB antenna protective casing was rotted and wire was exposed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2016
Resolved 14 June 2016
Resolution: Certified third party rep was onboard vessel and replaced EPRIB antenna before MI departure from vessel.
Fire Fighting › Fire Hoses › Condition
Issued 7 July 2009
Resolved
Provide (01) fire hose on weather deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2009
Resolution: Provided receipt showing the purchase of new fire hose.
Operations/Management › Vessel Traffic Service › Sailing Plan
Issued 7 July 2009
Resolved
Provide voyage plan IAW 46 CFR 185.503.
Action required: 705 - Other - as specified
Resolved 26 March 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Crankshaft
Issued 29 April 2008
Resolved
Provide covers on front of #3 & #4 MDE to protect personel from injury from rotating machinery.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2008
Communications › Public Address System › Loudspeaker
Issued 29 April 2008
Resolved
Repair or Replace PA speaker for lower cabin area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2008
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 29 April 2008
Resolved
Repair 3/4 level visual indicator and show proper operation.
Due 29 May 2008
Resolved 5 May 2008
Fire Fighting › Means of Escape › Emergency Lighting
Issued 29 April 2008
Resolved
Install additional emergency lighting in the main deck passenger compartment and to of stairway going to engine room
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2008
Operations/Management › Pollution › Control of Garbage
Issued 29 April 2008
Resolved
Post Waste Management Plan
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2008
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 29 April 2008
Resolved
Update Pollution Prevention Plan with diagram of fuel system
Action required: 703 - Prior to bunkering operations
Resolved 5 May 2008
Construction/Loadline › Hull › Hull Plating
Issued 12 February 2007
Resolved
Bow cleaved through iwo peak tank fwd of collision bulkhead. Make proper permanent repairs.
Action required: 705 - Other - as specified
Due 27 February 2007
Resolved 17 April 2007
Resolution: All repairs completed.
Construction/Loadline
Issued 6 June 1997
Resolved
PROPERLY MAKE CABLE PENETRATION LOCATED STARBOARD SIDE OF #2 WATERTIGHT BULKHEAD, WATERTIGHT IAW 46 CFR 171.114(2)
Condition: Unknown
Due 6 June 1997
Resolved 6 June 1997