Records from 1981 to 2025. Most recent: inspection, 10 November 2025.
Inspection history · 77
10 November 2025
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8331224
4 November 2025
Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8264142
22 July 2025
Cargo Tank Internal · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8183118
20 June 2025
Administrative Inspection · Drydock Extension · Load Line/Change of Employment · In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8167327
9 May 2025
Administrative Inspection · Drydock Extension
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8134846
22 April 2025
Administrative Inspection · Load Line/Change of Employment
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8130497
12 September 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7994934
4 June 2024
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7938587
31 July 2023
Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7756727
15 May 2023
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7688652
26 April 2023
Drydock Extension · Internal Structural Exam · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7676763
3 April 2023
Administrative Inspection · Drydock Extension · Internal Structural Exam · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7661865
23 June 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7484826
20 May 2021
Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7202293
15 March 2021
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7156595
7 July 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6999185
13 March 2020
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6926053
10 June 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6709152
16 May 2018
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6416087
4 January 2018
Cargo Tank Internal · Administrative Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6332430
15 June 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6176343
6 September 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5993067
15 October 2015
Damage Survey · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5743183
23 September 2015
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5726773
19 August 2015
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5220286
16 June 2014
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4890004
19 June 2012
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4348082
4 October 2010
Administrative Inspection · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3862812
29 October 2008
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3353465
18 June 2008
Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3248937
13 September 2006
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2777120
29 August 2005
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2475539
13 June 2005
Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2382909
18 January 2005
Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2277255
3 August 2004
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2155375
29 July 2004
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2149036
21 July 2004
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2140267
28 June 2004
MTSA/ISPS Verification
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2114035
26 April 2004
In-Service Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2053004
30 April 2003
Inclining Experiment
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1784137
17 March 2003
Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1759205
29 May 2002
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1622446
21 February 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1487863
13 October 2001
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 1521965
4 April 2001
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1440472
24 October 2000
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 769310
30 September 2000
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 198572
20 April 2000
COI Inspection · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369618
13 April 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 163192
13 April 2000
Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 819316
29 June 1999
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375825
4 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 793083
16 June 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411699
12 May 1997
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446485
9 April 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 64899
7 May 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1431636
10 May 1995
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1363287
24 May 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465146
27 May 1993
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434009
4 August 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472648
6 November 1991
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1249281
24 September 1991
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1246058
20 August 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1252246
21 August 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 902726
4 April 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 983695
22 August 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1033475
9 September 1988
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1042619
31 August 1988
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1041516
23 September 1987
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318050
17 February 1987
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1006620
24 September 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015046
24 September 1985
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 994084
18 September 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284666
14 September 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964006
31 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966582
15 September 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272606
21 September 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 968622
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 November 2025
No resolution recorded
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in § 176.500(b)(1) [annual inspection within 3 months before or after each anniversary date] and your Certificate of Inspection must be endorsed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2025 — due date passed with no resolution recorded
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 September 2024
Resolved
Every vessel must have a detailed inspection on radio installations by an FCC-licensed technician every 5 years. Vessel did not have a Safety Radiotelephony Certificate. Provide MI with certificate.
47CFR173.15(a)(1) - 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2024
Resolved 18 September 2024
Resolution: Vessel had inspection and provided Safety Radiotelephony Certificate.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 September 2024
Resolved
Portable fire estinguishers must be maintained IAW NFPA 10. Fire extinguishers shall be inspected atleast once per calendar month. Did not have log of monthly inspections.
46CFR176.810(b)/NFPA 10/7.2.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2024
Resolved 17 September 2024
Resolution: Vessel purchased inspection tags to track the monthly inspections.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 September 2024
Resolved
No person may use a vessel unless it has a number issued on a certificate of number by the issuing authority in the state of principal operation. Vessel did not have FL registration.
33CFR173.15(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2024
Resolved 16 October 2024
Resolution: Received FL registration.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 31 July 2023
Resolved
A hydraulic release used in the installation of any liferaft, inflatable liferaft, lifefloat, or buoyant apparatus shall undergo the periodic servicing and testing … every 12 months. Both hydrostatic releases for both liferafts were found by MI’s to be overdue for inspection. Vessel must replace or properly inspect 2 hydrostatic releases.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2023
Resolution: Hydrostatic release dates replaced, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 31 July 2023
Resolved
At each initial and subsequent inspection for certification and reinspection the firefighting equipment of all vessels shall be inspected and all deficiencies found shall be corrected. MI’s discovered that the fire panel will consistently sound at all times, and can only be turned off by silencing the panel. Vessel must fix the fire detection panel so that it will operate as intended.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2023
Resolution: Fire panel repaired, tested, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 April 2023
Resolved
The owner or managing operator shall make a vessel available for dry dock examinations, internal structural examinations required by this section. Vessel has gone past its dry dock date.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2023
Resolution: Issued dry dock extension approval letter following satisfactory ISE.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 23 June 2022
Resolved
Each item of survival craft equipment must be of good quality and efficient for the purpose it is intended to serve. STBD side life raft hydrostatic release is expired.
46CFR180.175(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2022
Resolution: Operator provided evidence via photo of hydrostatic release replacement.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 15 March 2021
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that... man overboard drill be held under simulated emergency conditions. Vessel was unable to complete man overboard drill due to not meeting their minimum safe manning.
46 CFR 176.808(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2021
Resolution: Vessel safely completed man overboard drills
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 15 March 2021
Resolved
Each overnight accommodation space on a vessel with overnight accommodations for passengers must be fitted with an independent modular smoke detection and alarm unit. The vessel was missing smoke detectors in overnight accommodation spaces.
46 CFR 181.405(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2021
Resolution: Vessel installed additional smoke detectors
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 16 May 2018
Resolved
Provide all items required for drug testing program as listed in chemical testing audit. 46 CFR 16.260
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2018
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 16 May 2018
Resolved
Renew retro-reflective tape on all lifebuoys. 46 CFR 185.604
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2018
Lifesaving › Lifebuoys › Serviceable
Issued 15 June 2017
Resolved
Retro-reflective tape on lifering is worn. Renew retro-tape on port and starboard liferings.
Due 15 June 2017
Resolved 15 June 2017
Resolution: Retro-tape renewed.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 15 June 2017
Resolved
Missing 1-red and 3-orange distress signals. Provide adequate number of distress signals.
Due 15 June 2017
Resolved 15 June 2017
Resolution: Proper number of distress signals were provided.
Communications › Radio Communications › EPIRB
Issued 6 September 2016
Resolved
Hydrostatic release for EPIRB has expired. Renew hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2016
Resolved 7 September 2016
Resolution: a new Hammar EPIRB type hydrostatic release was purchased and placed in service.
Engineering › Fuel Oil Service System › Filter
Issued 6 September 2016
Resolved
Extension cord used for hydraulic filter pump. Either remove extension cord or provide permanent installation.
Action required: 705 - Other - as specified
Due 20 September 2016
Resolved 7 September 2016
Resolution: extension cord was removed from improper service.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 August 2015
Resolved
Request amended COI to reflect authorized oceans route for international voyage.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 September 2015
Resolved 10 September 2015
Resolution: Received request from operator for oceans intl endorsement.
Electrical › Electric Supply System (service) › Cable
Issued 19 August 2015
Resolved
Provide electrical instillation in accordance with 46CFR183. Namely remove power strips from behind console and in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2015
Resolved 18 September 2015
Resolution: Navigational equipment rewired with marine grade wiring and all non-marine wires removed.
Lifesaving › Lifebuoys › Immediately Available
Issued 19 August 2015
Resolved
Provide corrosion resistance clip for port side ring buoy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2015
Resolved 10 September 2015
Resolution: Vessel provided corrosion resistane clip for waterlight
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 19 August 2015
Resolved
Provide MAWP for the Air System
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 September 2015
Resolved 10 September 2015
Resolution: Operator provided plans indicating MAWP, then labeled receiver to reflect.
Engineering › Compressed Air System (control) › Valve
Issued 19 August 2015
Resolved
Provide data documentation set point of relief valve for air receiver.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 September 2015
Resolved 10 September 2015
Resolution: Operator purchased new relief valve meeting system requirement IAW provided plan.
Operations/Management › Drills/Instruction › Not Conducted
Issued 16 June 2014
Resolved
Conduct satisfactory fire/man overboard drill with crew.
Action required: 705 - Other - as specified
Due 15 July 2014
Resolved 8 July 2014
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 16 June 2014
Resolved
Complete DAPI compliance checklist.
Action required: 705 - Other - as specified
Due 15 July 2014
Resolved 8 July 2014
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 16 June 2014
Resolved
Provide current FCC certificates as required. (to include Bridge to Bridge as both expired February 2014)
Action required: 705 - Other - as specified
Due 15 July 2014
Resolved 8 July 2014
Lifesaving › Lifebuoys › Stowage
Issued 16 June 2014
Resolved
Mount aft ring/lifebuoy.
Action required: 705 - Other - as specified
Due 15 July 2014
Resolved 8 July 2014
Lifesaving › Lifebuoys › Stowage
Issued 16 June 2014
Resolved
Remove port ring/lifebuoy light to accessible location.
Action required: 705 - Other - as specified
Due 15 July 2014
Resolved 8 July 2014
Fire Fighting › Fire Main › Condition
Issued 16 June 2014
Resolved
Renew 2" pipe where wasted below fire monitor.
Action required: 705 - Other - as specified
Due 15 July 2014
Resolved 8 July 2014
Communications › Radio Communications › VHF Radiotelephone
Issued 18 June 2008
Resolved
VHF radio could only operate on back-up power. Repair VHF radio prior to operation.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 21 August 2008
Resolution: Vsl provided technician''''s report for repair of VHF radio; witness test of VHF radio on CH16 & CH11.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 18 June 2008
Resolved
Provide documentation attesting to portable CO2 servicing IAW 46CFR176.810(b)(1) and NFPA 10.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 18 June 2008
Resolution: Vsl provided management plan for weighing and logging CO2 extinguishers.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 18 June 2008
Resolved
Provide VRP approval ltr & plan.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 August 2008
Resolution: Vsl provided VRP - verified to have necessary info & CG approval ltr.
Stability › Incline Test › General
Issued 29 July 2004
Resolved
PROVIDE STABILITY LETTER/BOOKLET DATED 19 JUNE 2003
Due 5 August 2004
Resolved 18 January 2005
Resolution: Stability letter/booklet dated 19 June 2003 on board vessel and available to Master.
Personnel › Training › First Aid/CPR
Issued 29 July 2004
Resolved
PROVIDE CPR/FIRST AID TRAINING FOR CREW.
Due 5 August 2004
Resolved 29 July 2004
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 29 July 2004
Resolved
MAKE PRESSURE VESSEL AVAILABLE FOR INSPECTION.
Due 5 August 2004
Resolved 29 July 2004
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 29 July 2004
Resolved
COMPLETE EMERGENCY DRILLS
Due 30 July 2004
Resolved 29 July 2004
Construction/Loadline › Structures › Deck Plating
Issued 29 July 2004
Resolved
MAKE ANCHOR LOCKER DECK AVAILABLE FOR INSPECTION.
Due 5 August 2004
Resolved 29 July 2004
Construction/Loadline › Penetrations › Gasket
Issued 29 July 2004
Resolved
PROVIDE CAPTURE DEVICE FOR FORWARD HATCH.
Due 5 August 2004
Resolved 29 July 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 July 2004
Resolved
RENEW EYE WASH STATION.
Due 5 August 2004
Resolved 29 July 2004
Engineering › Feedwater/Condensate Water System › Pump
Issued 29 July 2004
Resolved
RENEW SANITARY PUMP HOUSING.
Due 5 August 2004
Resolved 29 July 2004
Engineering › Fuel Oil Service System
Issued 10 June 2003
Resolved
PROVIDE METALLIC PLUG FOR PORT GENERATOR FUEL FILTER RAYCOR UNIT. LEGACY COMPONENT DESC: Filter
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2003
Resolved 11 June 2003
Engineering › Bilge Water Management System › Manifold
Issued 10 June 2003
Resolved
LABEL ALL BILGE MANIFOLD VALVES.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2003
Resolved 11 June 2003
Fire Fighting › Means of Escape › Escape Route Signs
Issued 10 June 2003
Resolved
LABEL EMERGENCY ESCAPE IN ENGINE ROOM.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2003
Resolved 11 June 2003
Communications › Radio Communications
Issued 10 June 2003
Resolved
PROVIDE OPERATIONAL SINGLE SIDE BAND RADIO. LEGACY COMPONENT DESC: Radiotelephone Transceiver (2-4 MHz)
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2003
Resolved 11 June 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 June 2003
Resolved
PROVIDE NOT UNDER COMMAND LIGHTS.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2003
Resolved 11 June 2003
Stability › Watertight Integrity
Issued 10 June 2003
Resolved
RENEW GASKETS ON BOTH MAIN DECK WATER TIGHT DOORS. LEGACY COMPONENT DESC: DOOR GASKETS
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2003
Resolved 11 June 2003
Stability › Watertight Integrity
Issued 10 June 2003
Resolved
INSTALL INVERTED CHECK BALL VENTS ON ALL DECK VENT PIPES. LEGACY COMPONENT DESC: DECK VENTS
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2003
Resolved 11 June 2003
Construction/Loadline › Structures
Issued 21 February 2002
Resolved
Port and stbd E/R soft patches wasted, requiring replacement. Port soft patch had a corrosion hole that had a doubler plate installed. Issued 835 to renew E/R soft patches prior to 24 Mar 2002 LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2002
Resolved 17 March 2003