ALTON BELLE CASINO II

ALTON BELLE CASINO II is a 1993 industrial vessel. The Coast Guard has recorded 191 inspections since 1993, most recently in July 2012, along with 306 deficiencies and 2 casualty investigations between 2008 and 2013.

Records from 1993 to 2013. Most recent: casualty investigation, 25 February 2013.

Built
1993
Last inspected
2 July 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBU4274
387813
Flag
UNITED STATES
367360330
Maury page id
psix-387813

Inspections, by type

…with no type recorded47
Years with a record 20 calendar years (1993–2012)
The 191 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it1187 - Regulatory (Subpart C or D), Gross Ton
3357 - Convention (Subpart B), Gross Ton
864 - Regulatory (Subpart C or D), Net Ton
1007 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WBU4274MMSI 367360330 · active · compulsorily equipped · granted 15 May 2018, expires 3 June 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ALTON BELLE CASINO II RESCUE BOAT 1 Industrial Vessel · MISLE 992896 · 2 March 2008 · activity 3295548ANASTASIA Passenger (Inspected) · MISLE 229491 · 28 September 2003 · activity 1945119

Inspection history · 191

2 July 2012 Re-Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4369603
12 December 2011 Re-Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4206515
20 September 2011 Re-Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4150015
10 January 2011 Re-Inspection · MTSA Verification · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3923916
6 December 2010 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3905308
30 November 2010 Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3900175
22 October 2010 Deficiency Check · Re-Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3873943
24 September 2010 Deficiency Check · In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3856241
30 March 2010 COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3702707
12 January 2010 Administrative Inspection · Deficiency Check · Re-Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3655835
28 July 2009 In-Service Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3549373
23 July 2009 MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3543318
21 July 2009 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3544385
7 July 2009 Re-Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3526036
12 May 2009 MTSA Verification · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3473342
3 April 2009 Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3443723
16 January 2009 Plan Review (Other than "T") · In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3395276
5 January 2009 Deficiency Check · Re-Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3388872
14 October 2008 Re-Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3345179
3 September 2008 Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3316738
31 July 2008 In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3270543
2 July 2008 Re-Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3253328
14 May 2008 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3210900
2 April 2008 MTSA Verification · In-Service Inspection · Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3175960
2 March 2008 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3295548
17 January 2008 Re-Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3126216
29 October 2007 Plan Review (Other than "T") · Construction Oversight
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3089313
16 October 2007 Re-Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3081073
12 July 2007 Administrative Inspection · Deficiency Check · Re-Inspection · In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2992443
14 March 2007 COI Inspection · MTSA Verification · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2885110
8 September 2006 Administrative Inspection · Periodic Inspection · In-Service Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2742703
19 July 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2718186
19 July 2006 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2718198
26 June 2006 MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2778836
14 June 2006 In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2666585
10 April 2006 In-Service Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2613469
16 March 2006 COI Inspection · MTSA Verification · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2584177
19 January 2006 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2561604
23 November 2005 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2539833
15 November 2005 Periodic Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2514725
28 October 2005 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2524009
12 October 2005 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2513157
19 September 2005 Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2456014
25 August 2005 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2474631
9 August 2005 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2455897
14 July 2005 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2406901
26 April 2005 In-Service Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2343408
8 April 2005 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2326071
1 March 2005 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2301428
17 February 2005 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2286824
28 December 2004 Plan Review (Other than "T")
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2265712
22 October 2004 Re-Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2226456
7 September 2004 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2189564
19 August 2004 MTSA Verification · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2108571
29 April 2004 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2055624
16 April 2004 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2045230
29 March 2004 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2033372
8 January 2004 Quarterly Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1958137
31 October 2003 Deficiency Check · In-Service Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1934369
8 October 2003 Quarterly Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1911810
28 September 2003 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1945119
15 July 2003 Quarterly Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1832216
27 May 2003 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1803021
16 April 2003 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1764562
4 April 2003 In-Service Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1772015
29 January 2003 Deficiency Check · Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1735103
17 January 2003 Examination of Repairs · Quarterly Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1729565
6 November 2002 Security Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1701832
28 October 2002 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1697000
16 October 2002 Quarterly Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1687737
26 September 2002 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1680568
8 August 2002 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1658367
23 July 2002 Quarterly Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1644149
23 July 2002 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1650864
16 April 2002 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1603080
25 March 2002 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1599027
14 February 2002 Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1493510
6 February 2002 Deadweight Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1486115
29 January 2002 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1482347
24 January 2002 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1479869
26 November 2001 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1473840
24 October 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1389494
2 October 2001 Underwater Inspection in lieu of Drydock
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1484248
20 September 2001 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1475628
24 July 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1413999
30 May 2001 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1070618
23 May 2001 Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1486886
9 May 2001 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1063329
19 April 2001 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1445804
12 February 2001 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 214775
24 January 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1432433
20 October 2000 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1454863
5 October 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1376442
13 July 2000 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1432357
6 June 2000 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1051092
20 April 2000 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1429338
26 January 2000 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1410227
25 January 2000 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1388993
15 December 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 65900
10 December 1999 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 812113
1 November 1999 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1423281
11 September 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 789028
6 September 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1119745
12 August 1999 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 783239
3 August 1999 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1450331
20 April 1999 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1391019
18 February 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 187182
26 January 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 214154
20 January 1999 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1461945
18 November 1998 Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 806224
3 November 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1381364
25 September 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1384043
22 August 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 803313
12 August 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1386321
5 June 1998 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1126115
30 April 1998 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1398896
8 March 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 87860
17 February 1998 Deficiency Check · Deadweight Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1129487
11 February 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1421456
23 January 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1120612
22 January 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1390702
17 November 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1108691
4 November 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1466485
2 October 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 784770
18 August 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 55262
13 August 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1450062
29 July 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 784132
22 July 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 780563
21 June 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1112298
2 June 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1109923
14 May 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 81713
3 May 1997 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1419770
19 March 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1098370
12 February 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 184045
6 February 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1455451
15 January 1997 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1100207
5 November 1996 Deficiency Check · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1380692
1 August 1996 Deficiency Check · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1442446
9 July 1996 Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1089023
3 May 1996 COI Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1447583
25 March 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 164214
12 March 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 170931
4 March 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 885421
21 February 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 113467
19 February 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 5677
14 February 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 878341
12 February 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 76859
11 February 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 84546
7 February 1996 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1449900
1 February 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 139962
7 January 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1098132
6 January 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 9766
4 January 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 153643
5 December 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 882354
1 November 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1407567
26 October 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 876319
30 September 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 75871
30 August 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 25791
17 August 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 100042
17 August 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1186705
14 August 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1405765
12 June 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 170916
3 May 1995 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1183091
4 April 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 35486
28 February 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1162083
17 February 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1155623
16 February 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1155786
1 February 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1138513
31 January 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 374825
12 January 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 56908
8 December 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1142629
7 November 1994 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 867097
19 October 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 871195
5 August 1994 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1179614
26 May 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 861890
6 May 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1173069
6 May 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1329914
3 May 1994 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1170528
4 April 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 857951
21 March 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 855878
14 March 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 4072
24 February 1994 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 853624
20 January 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 852948
22 December 1993 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1159422
30 September 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1155238
20 September 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1147698
9 September 1993 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1142865
28 May 1993 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 850019
28 May 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1151384
13 May 1993 Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1397911
5 May 1993 Initial Certification · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 832873

Deficiency record · 306

Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 16 July 2012 Resolved
One e-room tank is right at 10% agent loss due to leaking schrader valve. Replaced tank with new (already ordered) with observation by the USCG Inspector.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 20 August 2012
Resolution: See scanned tech report. System is fully operatonal as designed on this date.
Engineering › Fuel Oil Service System › Pump
Issued 3 July 2012 Resolved
Make permanent repair to remove fuel leak on hand pump iwo port fuel tank. Small leak is present.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 July 2012
Resolved 16 July 2012
Resolution: New pump was installed. At first leaks were found in the pump piping but after tightening all pipes the leaks stopped.
Engineering › Steam Boiler (auxiliary/waste heat) › Stack Casing
Issued 3 July 2012 Resolved
Make permanent repairs to remove exhaust leak on boiler exhasut ducting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 July 2012
Resolved 16 July 2012
Resolution: All leaks were fixed an area repainted.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 3 July 2012 Resolved
Prove proper (latching) opertion of fire screen doors #1 and # 13.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2012
Resolved 16 July 2012
Resolution: Doors were repaired on 3 July - this is first visit to vessel to verify. All doors shut properly as designed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 July 2012 Resolved
Post COD when it is received from Documentation Center.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 July 2012
Resolved 24 July 2012
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 3 July 2012 Resolved
Install e-light iwo 3rd deck employee stairwell to assist with crew egress/normal night transiting.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 July 2012
Resolved 16 July 2012
Resolution: New light bulbs in exsitng light fixtures lightened up the egress path. No light needs to be installed at this time. Follow up planned for next quarterly inspection.
Communications › Internal Communications System › Sound-powered Telephone
Issued 10 January 2011 Resolved
Update all telephone emergency number decals vessel wide.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 10 February 2011
Resolution: All phone lists were updated and provided for e-phones.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 10 January 2011 Resolved
Stencil main deck EGRESS Scuttle mats ensuring that they remain accessable during emergencies.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 10 February 2011
Resolution: Mats were stenciled as required.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 January 2011 Resolved
Prove proper operation of Fire Screen Door # 3-9. Door was originally designed to close tightly when tripped and needs slight adjustment to make it work correctly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 10 February 2011
Resolution: Operational ck was sat.
Lifesaving › Launching Appliances › Davit
Issued 10 January 2011 Resolved
Prove proper operaton of the rescue boat winch. The amb outside temp was below freezing which caused the operation problem and the river was ice jammed removing the urgency for immediate repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 10 February 2011
Resolution: Boat winch working normally during this visit.
Electrical › Electrical Distribution System (emergency) › Switch
Issued 10 January 2011 Resolved
Replace the toggle switch on Bridge that acctuates F/S door release. Doors release with fire alram actuation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 10 January 2011
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 10 January 2011 Resolved
Provide proper documentation that the electrical alterations iwo the three aft deck smoke rooms have been submitted and approved via Marine Safety Center and local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2011
Resolved 23 June 2011
Resolution: MSC Approval was achieved and construction was satisfactory.
Fire Fighting › Ventilation Systems › Fans
Issued 10 January 2011 Resolved
Clean the 3rd deck fan motors and squirrel cages at aft fire screen doors. The curtain ventilation motors/fans are overwhelmed with dust and dirt and could easily casue a fire.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 10 February 2011
Resolution: Motors and fans were cleaned.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 January 2011 Resolved
Make the light fixture for laft 3rd deck lifejacket storage operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 10 February 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 January 2011 Resolved
Update the bridge first aid kid to reflect full inventory requirement as posted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 10 February 2011
Resolution: Kit was updated.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 10 January 2011 Resolved
Ensure all Emergency lights on board are operational as designed. Several lights were inop due to the extreme low amb air temperature.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 10 February 2011
Resolution: Lights are now operational.
Fire Fighting › Ventilation Systems › Ducts
Issued 30 November 2010 Resolved
Ventilation for 4th deck A/C unit unable to properly close. Repair or replace closure system to ensure proper operation.
Action required: 705 - Other - as specified
Due 30 December 2010
Resolved 12 January 2011
Resolution: Ventilation closed as designed when tested.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 22 October 2010 Resolved
3rd deck stbd side exterior passageway outlet showed an open neutral when tested.
Action required: 705 - Other - as specified
Due 29 October 2010
Resolved 30 November 2010
Engineering › Pressure Vessel › Shell Plate
Issued 22 October 2010 Resolved
Liquor room pressure vessel unavailable for complete internal inspection due to inability to remove fitting.
Action required: 705 - Other - as specified
Due 5 November 2010
Resolved 30 November 2010
Resolution: New Pressure Vessel Installed.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 22 October 2010 Resolved
Ventilation system duck hatches (fire dampeners) unavailable for inspection. Make all fire dampers available for inspection.
Action required: 705 - Other - as specified
Due 22 November 2010
Resolved 30 November 2010
Resolution: All dampers and vent openings available for inspection.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 22 October 2010 Resolved
No record of tests conducted by third party of fixed fire suppression systems (3).
Action required: 705 - Other - as specified
Due 5 November 2010
Resolved 30 November 2010
Resolution: Reviewed third party (Weber Fire & Safety Equipment Co.) fire servicing report dated 7/27/10 for Halon systems in Engine Room, Bow thruster space and Generator Room. All Satisfactory.
Electrical › Electric Generation Source (service) › Generator
Issued 22 October 2010 Resolved
Prove proper operation of the STBD generator and reverse power relays on both generators.
Action required: 705 - Other - as specified
Due 29 October 2010
Resolved 30 November 2010
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 October 2010 Resolved
Repair the port sewage room E-light, light was inop and the diffuser was broken.
Action required: 705 - Other - as specified
Due 22 November 2010
Resolved 30 November 2010
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 October 2010 Resolved
Install an additional E-light, 1st deck, stbd stern around slot machine row 26.
Action required: 705 - Other - as specified
Due 22 November 2010
Resolved 30 November 2010
Resolution: Overhead lighting near slot machine row 26 placed on emergency circuit and satisfactorily tested.
Fire Fighting › Structural - A Class Divisions › Sidescuttles
Issued 22 October 2010 Resolved
Prove proper operation of FSD #3. Striker plate was catching the door.
Action required: 705 - Other - as specified
Due 29 October 2010
Resolved 30 November 2010
Resolution: Striker plate replaced and satisfactorily tested.
Engineering › Bilge Water Management System › Piping
Issued 22 October 2010 Resolved
Provide physical access (minimum 18") to the soft count void high level bilge alarm and bilge suction.
Action required: 705 - Other - as specified
Due 22 November 2010
Resolved 30 November 2010
Engineering › Bilge Water Management System › Not Operational
Issued 22 October 2010 Resolved
Prove proper operation of the engineroom, fire pump bilge suction system.
Action required: 705 - Other - as specified
Due 22 November 2010
Resolved 30 November 2010
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 22 October 2010 Resolved
Ensure the vessel's heating boiler flame failure alarm has an audible and visual indicator.
Action required: 705 - Other - as specified
Due 6 November 2010
Resolved 30 November 2010
Accommodation/Occupational Safety › Heating › Heating Fuel
Issued 22 October 2010 Resolved
Prior to operating, ensure the portable LPG heaters in the smoking huts meet the requirements of 46CFR58.16
Action required: 705 - Other - as specified
Due 22 November 2010
Resolved 30 November 2010
Resolution: All portable LPG heating units removed from the vessel.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 22 October 2010 Resolved
Provide proof that the vessel's automation test procedures have been approved by the Coast Guard as per 46CFR61.40.
Action required: 705 - Other - as specified
Due 1 July 2011
Resolved 23 June 2011
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 22 October 2010 Resolved
Prove proper operation of the Port MDE reduction gear high temperature alarm.
Action required: 705 - Other - as specified
Due 22 November 2010
Resolved 30 November 2010
Communications › Visual Communication › Red Warning Signal
Issued 22 October 2010 Resolved
Install an amber engine alarm indicator light in the generator room.
Action required: 705 - Other - as specified
Due 22 November 2010
Resolved 30 November 2010
Resolution: Amber light installed and satisfactorily tested.
Navigation › Collision/Grounding Avoidance › Radar
Issued 24 September 2010 Resolved
Surface radar is not working properly. Repair/replace radar.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2010
Resolved 22 October 2010
Resolution: Radar demonstrated operational.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 24 September 2010 Resolved
Local Notice to Mariners is over 1 month old. Update and keep current.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2010
Resolved 22 October 2010
Resolution: LNMs updated.
Electrical › Electrical Distribution System (emergency) › Cable
Issued 24 September 2010 Resolved
Aft bulkhead cable brackets to bilge pump / fire pump control panel missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2010
Resolved 22 October 2010
Resolution: Brackets repaired/replaced.
Electrical › Electric Generation Source (service) › Generator
Issued 24 September 2010 Resolved
Hi-temp shutdown for generator is not operational, repair to operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2010
Resolved 22 October 2010
Resolution: Shutdown demonstrated operational.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 30 March 2010 Resolved
Require MOB be conducted in the presence of the attending marine inspector. Drill not conducted during COI due to high water. Original 835 date issued for correction by 30APR10, extended to 30MAY10 due to extended high water.
Action required: 705 - Other - as specified
Due 30 May 2010
Resolved 24 June 2010
Resolution: Vessel crew conducted successful man over board drill.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 12 January 2010 Resolved
Properly remove paint from ASME labels on both pressure vessels (air tanks).
Action required: 705 - Other - as specified
Due 26 January 2010
Resolved 29 January 2010
Engineering › Compressed Air System (start air) › Compressor
Issued 12 January 2010 Resolved
Properly repair oil leak on #2 air compressor.
Action required: 705 - Other - as specified
Due 26 January 2010
Resolved 29 January 2010
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 12 January 2010 Resolved
Properly conduct maintenenace on both drain plugs on the #1 pressure vessel (air tank)
Action required: 705 - Other - as specified
Due 26 January 2010
Resolved 29 January 2010
Personnel › Training › First Aid/CPR
Issued 7 July 2009 Resolved
Properly provide first aid/CPR training to at least 50% of the marine crew.
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 7 July 2009
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 7 July 2009 Resolved
Properly remove water from battery boxes in the engine room.
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 28 July 2009
Lifesaving › Inflatable Liferafts › Markings
Issued 7 July 2009 Resolved
Properly stencil name of vessel on life raft.
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 7 October 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 July 2009 Resolved
Replace worn PFD instruction placards at storage locations.
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 7 October 2009
Navigation › Collision/Grounding Avoidance › Radar
Issued 3 April 2009 Resolved
Provide technicians report stating proper operation of radar. This requirement must be corrected prior to getting underway.
Action required: 705 - Other - as specified
Due 3 May 2009
Resolved 20 May 2009
Resolution: [name withheld] verified, see attached documents for reciept
Electrical › Electric Supply System (service) › Battery Installation
Issued 3 April 2009 Resolved
Repair/replace stbd bank of batteries on the vessel's bridge. This must be corrected before getting underway.
Action required: 705 - Other - as specified
Due 17 June 2009
Resolved 7 July 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 April 2009 Resolved
Properly renew navigation light on #2 rescue boat to provide good connection.
Action required: 705 - Other - as specified
Due 3 May 2009
Resolved 20 May 2009
Resolution: [name withheld] Operation
Electrical › Lighting (service) › Lighting Fixture
Issued 3 April 2009 Resolved
Ensure all emergency exterior lights are marked with "E" that are on the emergency circuit.
Action required: 705 - Other - as specified
Due 3 May 2009
Resolved 20 May 2009
Resolution: [name withheld] Verified
Operations/Management › Drills/Instruction › Not Conducted
Issued 3 April 2009 Resolved
Appoint VSO as collateral duty for vessel master. Pass a drill (MTSA) by 17APR09 with Coast Guard marine inspectors present.
Action required: 705 - Other - as specified
Due 17 April 2009
Resolved 20 May 2009
Resolution: [name withheld] Verified
Operations/Management › Drills/Instruction › Not Conducted
Issued 3 April 2009 Resolved
Provide training to VSOs and properly document.
Action required: 705 - Other - as specified
Due 3 May 2009
Resolved 20 May 2009
Resolution: CWO brown Verified see attached files
Electrical › Electrical Distribution System (emergency) › Panelboard
Issued 14 January 2009 Resolved
Ground amp meter reading 10+ on distribution panel for the Emergency Generator.
Action required: 705 - Other - as specified
Due 14 February 2009
Resolved 20 January 2009
Communications › Internal Communications System › Sound-powered Telephone
Issued 14 January 2009 Resolved
No voice transmission to/from bridge.
Action required: 705 - Other - as specified
Due 14 February 2009
Resolved 20 January 2009
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 14 January 2009 Resolved
Anchor line severely worn at both ends of line.
Action required: 705 - Other - as specified
Due 14 February 2009
Resolved 3 April 2009
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 January 2009 Resolved
No Coast Guard approval for installed pre-engineered FM-200 fire suppression system in the computer room.
Action required: 705 - Other - as specified
Due 1 January 2010
Resolved 12 January 2011
Resolution: FM-200 fire system disconnected as required and no longer used for protective service. Company will not attempt to get system approved.
Personnel › Training › Familiarization Training
Issued 14 January 2009 Resolved
Crew unfamiliar with newly installed FM-200 pre-engineer fire suppression system in computer room.
Action required: 705 - Other - as specified
Due 14 February 2009
Resolved 20 January 2009
Construction/Loadline › Structures › Door
Issued 17 July 2007 Resolved
Three exterior doors on starboard side, first deck are damaged, corroded, and unable to properly close compromising ability to achieve a weather tight seal.
Action required: 705 - Other - as specified
Resolved 17 October 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 17 July 2007 Resolved
First deck aft slot cage requires addition of an emergency lighting fixture.
Action required: 705 - Other - as specified
Resolved 17 October 2007
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 12 July 2007 Resolved
Fire suppression systems (3) out of compliance with required inspection schedule.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Resolution: Wintessed third party operational test/inspection of equipment.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (air motor)
Issued 30 April 2007 Resolved
Port generator engine: Fuel, used to lubricate diesel engine's air starter blew out back of starter in direct vicinity of engine when activated.
Action required: 705 - Other - as specified
Due 15 May 2007
Resolved 10 May 2007
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 14 March 2007 Resolved
Exhaust pipe for port generator diesel engine leaking in steering pump room.
Action required: 705 - Other - as specified
Due 14 April 2007
Resolved 30 April 2007
Communications › Internal Communications System › Sound-powered Telephone
Issued 14 March 2007 Resolved
Pilot house sound powered phone inoperable.
Action required: 705 - Other - as specified
Due 14 April 2007
Resolved 30 April 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 14 March 2007 Resolved
Transmission from VHF radio labled "normal" was unreadable during radio check.
Action required: 705 - Other - as specified
Due 14 April 2007
Resolved 30 April 2007
Resolution: Radio attenna reported to have be in down position.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 14 March 2007 Resolved
2 Ring buoys on 2nd deck at stern of vessel unservicable; 1 ring buoy on 4th deck at stern requires restenciling.
Action required: 705 - Other - as specified
Due 15 May 2007
Resolved 10 May 2007
Fire Fighting › Structural - Horizontal Zones › General
Issued 8 September 2006 Resolved
Fire Door # 12 failed to adequately close once remotely swung.
Action required: 705 - Other - as specified
Due 22 September 2006
Resolved 14 March 2007
Resolution: Inspectors witnessed all fire doors operating satisfactorily.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Service
Issued 8 September 2006 Resolved
Documentation confirming service of extinguisher missing.
Action required: 705 - Other - as specified
Due 22 September 2006
Resolved 10 May 2007
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 5 June 2006 Resolved
Fire suppression systems (3) out of compliance with required inspection schedule.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 7 June 2006
Resolution: Independent fire service personnel inspected and tested engine room, bow thruster room, and emergency generator room fixed fire suppression systems. All systems certified by fire service technician.
Engineering › Steam Boiler (auxiliary/waste heat) › Refractory
Issued 10 April 2006 Resolved
Repair refractory
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 21 April 2006
Resolution: Refractory repaired
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 10 April 2006 Resolved
Replace relief valve mounting bolts showing signs of necking.
Action required: 705 - Other - as specified
Due 20 April 2006
Resolved 20 May 2006
Resolution: Repalced
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 March 2006 Resolved
Forward section of second deck bar, service wiring passes through opening in bar near bulkhead approximatly 3 feet from floor. Protective layer of wiring completely worn away exposing inner wiring (no bare wiring) subject to excess wear. Repair wiring.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 10 April 2006
Resolution: Completed.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 16 March 2006 Resolved
Draft marks were worn and no longer in a contrasting color to the vessel's hull. Properly paint hull marks in a contrasting color.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 1 April 2006
Resolution: Completed.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 16 March 2006 Resolved
Three of four SCBA air bottles were less then half full. Service bottles.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 16 March 2006
Resolution: Recharged same day.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 16 March 2006 Resolved
Fuel oil leak at tank for emergency generator.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 13 April 2006
Resolution: Repaired same day
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 16 March 2006 Resolved
Vessel operator to submit plan for weight testing cable and davit; vessel is restricted from allowing personnel in the rescue boat while suspended until equipment is successfully weight tested.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 10 April 2006
Resolution: Weight test completed
Operations/Management › Passenger Operations › Safety Orientation
Issued 16 March 2006 Resolved
Vessel operator failed to perform evacuation drill; operator to submit plan for pax count and date for drill to OCMI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 10 April 2006
Resolution: plans submitted wit date.
Operations/Management › Passenger Operations › Safety Orientation
Issued 16 March 2006 Resolved
Install emergency exit signs with battery backup at aft sections of passenger areas on all interior decks of vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 10 April 2006
Resolution: installed
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (air start)
Issued 16 March 2006 Resolved
Air equipped hoses on starboard main engine missing chaffing gear.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 10 April 2006
Resolution: Completed
Engineering › Compressed Air System (control) › Valve
Issued 16 March 2006 Resolved
Relief valve on starboard side compressed failed during testing. Valve required to be repaired/replaced. Until corrected, keep cross tank connect valve open.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 10 April 2006
Resolution: Resolved
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 16 March 2006 Resolved
1 PFD found with ripped outer cover & 1 PFD found with unreadable vessel name. Both PFDs from 4th deck PFD storage lockers. PFDs removed from service until replaced/re-stenciled.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 10 April 2006
Resolution: Resolved
Fire Fighting › Automatic Sprinkler System › Piping
Issued 13 February 2006 Resolved
Properly repair leaking section of sprinkler piping from the pressure tank to the main sprinkler line.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 February 2006
Resolved 16 March 2006
Resolution: Vessel personnel reported that leak was fixed on 13FEB2006 and proved proper operation of sprinkler piping during COI inspection.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 November 2005 Resolved
Properly mark lifering on 3rd deck port side with name of vessel.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 24 January 2006
Resolution: Lifering properly marked
Lifesaving › Lifebuoys › Serviceable
Issued 15 November 2005 Resolved
Properly repair/replace missing reflective tape on life rings located on the 3rd deck port side and 4th deck aft.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 19 January 2006
Resolution: Reflective tape properly replaced on life rings.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 15 November 2005 Resolved
Properly repair fire damper located on 3rd deck, 3rd damper aft of the pilot house port side so that is operates more easily allowing easy use in an emergency.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 19 January 2006
Resolution: Fire damper repaired for easire operation.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 15 November 2005 Resolved
Properly install exhaust lagging on al marine diesel engines turbo exhaust manifolds.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 16 March 2006
Resolution: Witnessed property installed exhaust lagging on all marine diesel engine turbo exhaust manifolds.
Fire Fighting › Firemans Outfit › Axe
Issued 15 November 2005 Resolved
Properly restencil fire axe sign on crew break room 3rd deck aft. Sign indicates that fire axe is located inside of the storage space.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 24 January 2006
Resolution: Fire ax sign was properly re-stenciled.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 July 2005 Resolved
Properly replace donning instructions on 4th deck life jacket storage boxes.
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 9 August 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 July 2005 Resolved
Properly replace line on life ring water light on stbd side of the 3rd deck.
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 23 August 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 15 July 2005 Resolved
Properly repair electric outlet on 2nd deck Mississippi room stbd side fwd (prong stuck in ground outlet) & outlet in hard count room (prong stuck in ground outlet) & outlet next to 1st deck mens room (reverse polarity) & outlet in employee stairwell 3rd deck (reverse polarity).
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 9 August 2005
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 15 July 2005 Resolved
Properly replace retro-reflective tape on life rings 1st deck stern and 3rd deck port side.
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 9 August 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 July 2005 Resolved
Properly stencil vessel name on life buoy 3rd deck port side.
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 9 August 2005
Documentation › Markings/Placards › Oil Discharge Placard
Issued 14 July 2005 Resolved
Properly post new oil discharge placard next to the bilge pump controller in the engine room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 9 August 2005
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 29 April 2005 Resolved
Prove proper operation of fixed firefighting system (halon) in the engine room/aux spaces. Prove halon cylinder is adequate to be used in system (hydro/gauge cylinder). The engine/aux spaces shall be manned at all times. The space will remained manned until the fixed firefighting system in the above spaces have been inspected by an attending U.S. Coast Guard marine inspector.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 16 May 2005
Resolution: New halon bottle installed.
Accommodation/Occupational Safety › Ventilation › General
Issued 8 April 2005 Resolved
Prove proper operation of ventilation fan in bow thruster room.
Due 15 April 2005
Resolved 29 April 2005
Lifesaving › Lifebuoys › Serviceable
Issued 8 April 2005 Resolved
Properly repair fourth deck, stbd side life ring bouy grab line (broken).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 29 April 2005
Fire Fighting › Firemans Outfit › Axe
Issued 8 April 2005 Resolved
Properly repair second deck port side aft fire axe head .
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 29 April 2005
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 8 April 2005 Resolved
Properly repair open ground on the stbd side, third deck, weather deck, 110 vt recepticle aft of the crews breakroom.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 29 April 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 April 2005 Resolved
Properly stencil the vessels name on the two third deck port side aft life rings.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 29 April 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 April 2005 Resolved
Properly install a corrosion resistant clip on the third deck portside lifering bouy float light.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 29 April 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 8 April 2005 Resolved
Properly clean trash and liquid from under the second deck bar.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 29 April 2005
Accommodation/Occupational Safety › Potable Water System › General
Issued 8 April 2005 Resolved
Properly repair sink drain (leaking water) third deck bar.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 29 April 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 8 April 2005 Resolved
Properly clean deck/repair leak in liquor dispensing room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 29 April 2005
Fire Fighting › Firemans Outfit › Axe
Issued 8 April 2005 Resolved
Properly repair loose fire axe head on the first deck, port side aft.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 29 April 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 April 2005 Resolved
Properly stencil the vessels name on the third deck port side life ring.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 29 April 2005
Communications › Internal Communications System › Sound-powered Telephone
Issued 17 February 2005 Resolved
Properly repair vessels sound powered telephone system.
Condition: Damaged By Earlier Event
Due 17 March 2005
Resolved 18 March 2005
Communications › Internal Communications System › Sound-powered Telephone
Issued 17 February 2005 Resolved
Properly repair battery back up system for ships public announcement system.
Condition: Unknown
Due 17 March 2005
Resolved 18 March 2005
Fire Fighting › Firemans Outfit › Axe
Issued 17 February 2005 Resolved
Properly repair loose fire axe head in crews break room, 3rd deck, stbd side.
Condition: Damaged By Earlier Event
Due 17 March 2005
Resolved 18 March 2005
Fire Fighting › Fire Hoses › Condition
Issued 17 February 2005 Resolved
Properly stencil vessels name on all ships fire hoses.
Condition: Placed in Improper Service
Due 17 March 2005
Resolved 18 March 2005
Lifesaving › Visual Distress Signals (General) › Condition
Issued 17 February 2005 Resolved
Properly repair/renew bouyant light on the 3rd deck.
Condition: Improper/Lack of Maintenance
Due 17 March 2005
Resolved 18 March 2005
Lifesaving › Hand Flares › Not on Board
Issued 17 February 2005 Resolved
Properly replace missing hand flares and stow in an approved container.
Condition: Unknown
Due 17 March 2005
Resolved 18 March 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 17 February 2005 Resolved
Properly repair two extinguished emergency lights; 1) port side aft, first deck, ovehead and 2) port side aft, second deck, overhead.
Condition: Unknown
Due 17 March 2005
Resolved 18 March 2005
Electrical › Electrical Distribution System (service) › Switch
Issued 17 February 2005 Resolved
Prove proper operation of reverse power relays on # 1 and 2 generators.
Condition: Unknown
Due 17 March 2005
Resolved 18 March 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 17 February 2005 Resolved
Properly repair electric box in bow thruster compartment.
Due 17 March 2005
Resolved 18 March 2005
Lifesaving › Buoyant Apparatus › Marking
Issued 17 February 2005 Resolved
Properly mark life ring on the 2nd deck aft (vessel name).
Condition: Improper/Lack of Maintenance
Due 17 March 2005
Resolved 18 March 2005
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 16 November 2004 Resolved
Properly prove operation of emergency electrical systems.
Condition: Unknown
Due 23 November 2004
Resolved 18 November 2004
Resolution: Conducted test of all emergency systems under power of the emergency generator.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 16 November 2004 Resolved
Repair reverse polarity on the lower 110v recepticle located next to black jack table 30.
Condition: Placed in Improper Service
Due 23 November 2004
Resolved 18 November 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 16 November 2004 Resolved
Replace missing electric cover on the 110 outlet in the engine control room.
Condition: Unknown
Due 23 November 2004
Resolved 18 November 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 16 November 2004 Resolved
Properly repair faulty ground that was found in the liquor locker room 110v electrical outlet.
Condition: Placed in Improper Service
Due 23 November 2004
Resolved 18 November 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 November 2004 Resolved
Replace missing items for the ships first aid kit. I provided the vessels safety officer with list of required items.
Condition: Improper/Lack of Maintenance
Due 23 November 2004
Resolved 18 November 2004
Communications › Internal Communications System › Portable Radios
Issued 16 November 2004 Resolved
Correct ineffective comms problem between the deck crew and security during emergency drills.
Condition: Unknown
Due 23 November 2004
Resolved 18 November 2004
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 16 November 2004 Resolved
Prove proper operation of liferaft releasing system.
Condition: Placed in Improper Service
Due 23 November 2004
Resolved 18 November 2004
Lifesaving › Launching Appliances › Davit
Issued 16 November 2004 Resolved
Renew port side first deck boat davit cable, damaged and needs to be renewed.
Condition: Damaged By Earlier Event
Due 23 November 2004
Resolved 18 November 2004
Fire Fighting › Firemans Outfit › Axe
Issued 16 November 2004 Resolved
Re-stencil vsls name, that is worn off of the aft first deck fire axe.
Condition: Damaged By Earlier Event
Due 23 November 2004
Resolved 18 November 2004
Electrical › Electric Generation Source (service) › Ground Detection
Issued 19 August 2004 Resolved
Properly repair open grounds (three). 1. Third deck bar stbd side. 2. 1st deck port side aft receptacle. 3. Pilot house receptacle stbd side outboard of helm.
Due 19 September 2004
Resolved 8 September 2004
Lifesaving › Buoyant Apparatus › Marking
Issued 19 August 2004 Resolved
Restencil vessel's name on two life rings. 1. 2nd deck portside. 2. Port bridge wing.
Condition: Improper/Lack of Maintenance
Due 19 September 2004
Resolved 8 September 2004
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 19 August 2004 Resolved
Properly maintain current notice to mariners in the pilot house.
Due 19 September 2004
Resolved 8 September 2004
Engineering › Lubricating Oil Service System › Gauge
Issued 19 August 2004 Resolved
Properly repair stbd eng lube oil pressure gauge in the pilot house.
Due 19 September 2004
Resolved 8 September 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 19 August 2004 Resolved
Replace tamper glass on halon system in the engine room.
Due 19 September 2004
Resolved 8 September 2004
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 19 August 2004 Resolved
Replace electrical outlet cover in vault room.
Due 19 September 2004
Resolved 8 September 2004
Accommodation/Occupational Safety › Ventilation › General
Issued 19 August 2004 Resolved
Properly clean vents in vault room.
Due 19 September 2004
Resolved 8 September 2004
Electrical › Electric Generation Source (service)
Issued 29 March 2004 Resolved
Prove proper operation of number 1 and 2 generators.
Due 16 April 2004
Resolved 16 April 2004
Electrical › Electric Generation Source (service)
Issued 29 March 2004 Resolved
Prove proper operation of reverse power relay. LEGACY COMPONENT DESC: Reverse power relay
Due 16 April 2004
Resolved 16 April 2004
Electrical › Electric Generation Source (emergency)
Issued 29 March 2004 Resolved
Prove proper operation of emergency electrical systems.
Due 16 April 2004
Resolved 16 April 2004
Electrical › Electric Generation Source (service)
Issued 8 October 2003 Resolved
Show proper operation of #1 Ship's Service Diesel Generator speed control. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Due 8 November 2003
Resolved 31 October 2003
Electrical › Electrical Distribution System (service)
Issued 8 October 2003 Resolved
Properly conduct reverse power relays on both generators. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper/Lack of Maintenance
Due 8 November 2003
Resolved 31 October 2003
Lifesaving › Inflatable Liferafts
Issued 8 October 2003 Resolved
Replace hold down straps on all life rafts. LEGACY COMPONENT DESC: Securing Strap
Condition: Improper/Lack of Maintenance
Due 8 November 2003
Resolved 31 October 2003
Fire Fighting › Firemans Outfit
Issued 8 October 2003 Resolved
Show proper repairs to SCBA regulator. LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Condition: Improper/Lack of Maintenance
Due 8 November 2003
Resolved 14 November 2003
Operations/Management › Vessel Safety Management
Issued 8 October 2003 Resolved
Vessel shall be manned at all times passengers and/or personnel are embarked in accordance with vessel COI, with a competent crew able to respond to all emergencies as determined by the cognizant [name withheld]: Emergency Preparedness
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 October 2003
Resolved 31 October 2003
Personnel › Training
Issued 16 April 2003 Resolved
Provide proof of training for all senior deckhands to include First Aid/CPR as required by NVIC 1-91. LEGACY COMPONENT DESC: First Aid/CPR
Due 16 May 2003
Resolved 27 May 2003
Electrical › Electrical Distribution System (service)
Issued 16 April 2003 Resolved
Remove dead end wiring in the first deck cage. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Due 16 May 2003
Resolved 27 May 2003
Documentation › Logs/Records
Issued 16 April 2003 Resolved
Provide proof of senior deckhand designation letters in accordance with NVIC 1-91.
Due 16 May 2003
Resolved 27 May 2003
Electrical › Electrical Distribution System (service)
Issued 16 April 2003 Resolved
Repair loose outlet in the aft bulkhead of the redemption cage. LEGACY COMPONENT DESC: Outlet Box
Condition: Unknown
Due 16 May 2003
Resolved 27 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 16 April 2003 Resolved
Replace broken window in the wheelhouse.
Condition: Unknown
Due 16 May 2003
Resolved 27 May 2003
Fire Fighting › Fixed Halon Fire Extinguishing System › Control Valve
Issued 4 April 2003 Resolved
Service halon bottle for engineroom which released during testing and re-install.
Due 15 April 2003
Resolved 10 April 2003
Engineering › Diesel Engine (auxiliary)
Issued 17 January 2003 Resolved
Show proper operation of #1 ship's service diesel generator jacket water shut down alarm. LEGACY COMPONENT DESC: Shutdown
Condition: Unknown
Due 17 February 2003
Resolved 29 January 2003
Fire Fighting › Automatic Sprinkler System
Issued 17 January 2003 Resolved
Replace the two sprinkler heads on 2nd deck mounted on the forward passneger bathroom bulkheads with the correct heads as approved. LEGACY COMPONENT DESC: Sprinklers
Condition: Improper Installation
Due 17 February 2003
Resolved 29 January 2003
Electrical › Electric Supply System (service)
Issued 16 October 2002 Resolved
Remove/clean battery acid from general alarm batteries in engine room LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Due 16 November 2002
Resolved 28 October 2002
Engineering › Bilge Water Management System
Issued 16 October 2002 Resolved
Repair/replace fire pump bilge suction foot valve and show proper operation of bilge suction with fire pump. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 16 November 2002
Resolved 28 October 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 16 October 2002 Resolved
Show proper operation of starboard MDE expansion tank low level alarm. LEGACY COMPONENT DESC: Waste Heat Recovery
Condition: Improper/Lack of Maintenance
Due 16 November 2002
Resolved 28 October 2002
Engineering › Bilge Water Management System
Issued 16 October 2002 Resolved
Post bilge system piping diagram in engine room and relabel bilge valves. LEGACY COMPONENT DESC: Manifold
Condition: Improper/Lack of Maintenance
Due 16 November 2002
Resolved 28 October 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 16 October 2002 Resolved
Replace expired items in first aid kits. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 16 November 2002
Resolved 28 October 2002
Electrical › Electrical Distribution System (service)
Issued 23 July 2002 Resolved
Remove all material blocking or obstructing means of access to circuit breaker panels within hard count room. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper/Lack of Maintenance
Due 2 August 2002
Resolved 12 August 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 23 July 2002 Resolved
Remove and replace expired items in all first aid kits and EMT bags. LEGACY COMPONENT DESC: Supplies
Condition: Improper/Lack of Maintenance
Due 23 August 2002
Resolved 12 August 2002
Fire Fighting › Automatic Sprinkler System
Issued 23 July 2002 Resolved
Show proper operation of the fire sprinkler system pump. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 2 August 2002
Resolved 12 August 2002
Fire Fighting › Ventilation Systems
Issued 16 April 2002 Resolved
Prove proper operation of all ventilation closures. LEGACY COMPONENT DESC: Operating Controls
Condition: Unknown
Due 16 May 2002
Resolved 6 May 2002
Electrical › Electrical Distribution System (service)
Issued 16 April 2002 Resolved
Properly mount electrical box located at C-stud 16 day table. LEGACY COMPONENT DESC: Junction Box
Condition: Improper Installation
Due 16 May 2002
Resolved 6 May 2002
Electrical › Electrical Distribution System (service)
Issued 16 April 2002 Resolved
Properly mount wire bundle located at 3 card #5 Day table. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 16 May 2002
Resolved 6 May 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 16 April 2002 Resolved
Properly clean behind Ice machine located in 2nd deck bar. LEGACY COMPONENT DESC: Open Deck Space
Condition: Improper/Lack of Maintenance
Due 16 May 2002
Resolved 6 May 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 16 April 2002 Resolved
Properly clean floor under ice machine located in 1st deck bar. LEGACY COMPONENT DESC: Open Deck Space
Condition: Improper/Lack of Maintenance
Due 16 May 2002
Resolved 6 May 2002
Engineering › Reduction Gearing/Clutches
Issued 16 April 2002 Resolved
Show proper operation of starboard reduction gear alarms. LEGACY COMPONENT DESC: Alarms
Due 16 May 2002
Resolved 6 May 2002
Electrical › Electrical Distribution System (service)
Issued 16 April 2002 Resolved
Properly repair/replace busted receptacle in soft count. LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Due 16 May 2002
Resolved 6 May 2002
Stability › Watertight Integrity
Issued 16 April 2002 Resolved
Relabel upper control station to WTD 2A. LEGACY COMPONENT DESC: Class III Water Tight Doors
Condition: Placed in Improper Service
Due 16 May 2002
Resolved 6 May 2002
Electrical › Electrical Distribution System (service)
Issued 16 April 2002 Resolved
Remove all obstructions from in front of electrical panels in hard count. LEGACY COMPONENT DESC: Panelboard
Condition: Placed in Improper Service
Due 16 May 2002
Resolved 6 May 2002
Electrical › Electric Supply System (service)
Issued 15 February 2002 Resolved
Properly support all star light wire runs. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 2 March 2002
Resolved 25 March 2002
Resolution: Inspected overhead of 1st and 2nd deck.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 29 January 2002 Resolved
Hydro test both 300 pound halon tanks for engineroom space halon system. LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Due 1 March 2002
Resolved 6 February 2002
Resolution: Tanks were inspected IAW 49 CFR 173.34. This site allows for a visual inspection every five years in lieu of hydrostatic testing every twelve years. Vessel was able to produce documentation to back up testing being completed. See NAVIC 3-95
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 29 January 2002 Resolved
Post approved system drawings for halon systems located in engineroom, emergency generator space, and bow thruster space. LEGACY COMPONENT DESC: Operating Controls
Condition: Unknown
Due 1 March 2002
Resolved 6 February 2002
Resolution: System drawings were mounted for each halon system.
Fire Fighting
Issued 20 April 2000 Resolved
Prove proper operation of all fire dampers.
Condition: Unknown
Due 20 April 2000
Resolved 20 April 2000
Documentation
Issued 20 April 2000 Resolved
Ensure vessel has accurate means of determining amount of passengers onboard and that the count is logged in the vessel log.
Condition: Unknown
Due 20 April 2000
Resolved 20 April 2000
Fire Fighting
Issued 1 November 1999 Resolved
REPAIR OR REPLACE INOPERATIVE PORTABLE SMOKE DETECTOR AND ENSURE ALL SMOKE DETECTORS ON BOARD ARE IN GOOD WORKING CONDITION.
Condition: Unknown
Due 16 November 1999
Resolved 16 November 1999
Engineering
Issued 3 August 1999 Resolved
Repair oil leaks on the outboard side #2 S/S generator.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Fire Fighting
Issued 3 August 1999 Resolved
Make 3rd deck port side sprinkler zone ready for testing.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Construction/Loadline
Issued 3 August 1999 Resolved
Repair oil leak on #1A water tight door at through wall fitting above door.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Construction/Loadline
Issued 3 August 1999 Resolved
Repair damage deck outside beer cooler threshold.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Fire Fighting
Issued 20 January 1999 Resolved
Provide updated copy of fire control plan.
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Electrical
Issued 20 January 1999 Resolved
Repair lighting portside forepeak locker.
Condition: Unknown
Due 17 February 1999
Resolved 18 February 1999
Electrical
Issued 20 January 1999 Resolved
Properly mount light & outlet box under bridge controls, port side.
Condition: Unknown
Due 17 February 1999
Resolved 18 February 1999
Electrical
Issued 20 January 1999 Resolved
Remove 4th deck "E" lights from switch in bridge.
Condition: Unknown
Due 17 February 1999
Resolved 18 February 1999
Lifesaving
Issued 20 January 1999 Resolved
Ensure proper operation of 3rd deck interior PA system.
Condition: Unknown
Due 17 February 1999
Resolved 18 February 1999
Electrical
Issued 20 January 1999 Resolved
Properly secure cut 110v wires in 1st, 2nd and 3rd deck cages.
Condition: Unknown
Due 17 February 1999
Resolved 18 February 1999
Electrical
Issued 20 January 1999 Resolved
Properly secure wires/outlet box in overhead of Mississippi Room above the high speed slot.
Condition: Unknown
Due 17 February 1999
Resolved 18 February 1999
Electrical
Issued 20 January 1999 Resolved
Remove extension cord and properly wire ATM machine outside second deck cage.
Condition: Unknown
Due 17 February 1999
Resolved 18 February 1999
Fire Fighting
Issued 20 January 1999 Resolved
Conduct satisfactory fire and man overboard drills.
Condition: Unknown
Due 17 February 1999
Resolved 18 February 1999
Engineering
Issued 20 January 1999 Resolved
Repair L/O leak on starboard generator at the line leading to the L/O cooler.
Condition: Unknown
Due 17 February 1999
Resolved 18 February 1999
Engineering
Issued 20 January 1999 Resolved
Repair F/O leak port generator outboard side at the cylinder head.
Condition: Unknown
Due 17 February 1999
Resolved 18 February 1999
Documentation
Issued 20 January 1999 Resolved
Conduct deadweight survey or provide CG with alternate documentation of weight additions/modifications to vessel.
Condition: Unknown
Due 17 February 1999
Resolved 18 February 1999
Lifesaving
Issued 20 January 1999 Resolved
Remove plywood from cages or provide evidence that vessel fireload has not been exceeded.
Condition: Unknown
Due 17 February 1999
Resolved 18 February 1999
Lifesaving
Issued 20 January 1999 Resolved
Prove operation of General Alarm strobe in forward crew lounge male restroom.
Condition: Unknown
Due 17 February 1999
Resolved 18 February 1999
Lifesaving
Issued 20 January 1999 Resolved
Prove prper operation of PA system in crew break area.
Condition: Unknown
Due 17 February 1999
Resolved 18 February 1999
Electrical
Issued 12 August 1998 Resolved
Properly secure wiring in crew's break room overhead._x001C_
Condition: Unknown
Due 12 August 1998
Resolved 12 August 1998
Accommodation/Occupational Safety
Issued 12 August 1998 Resolved
Remove Rubatex insulation from chill water/hot water piping and replace with proper insulation.
Condition: Unknown
Due 12 August 1998
Resolved 12 August 1998
Fire Fighting
Issued 12 August 1998 Resolved
Prove proper operation of general alarm strobe light on 2nd deck (aft).
Condition: Unknown
Due 12 August 1998
Resolved 12 August 1998
Lifesaving
Issued 12 August 1998 Resolved
Ensure music system deactivates when PA System is activated.
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Fire Fighting
Issued 12 August 1998 Resolved
Make sprinkler system head tank available for inspection.
Condition: Unknown
Due 12 August 1998
Resolved 12 August 1998
Electrical
Issued 12 August 1998 Resolved
Adjust emergency generator start up time so that it starts in less than 18 seconds after loss of main power.
Condition: Unknown
Due 12 August 1998
Resolved 12 August 1998
Engineering
Issued 12 August 1998 Resolved
Prove proper operation of propulsion, steering, and bow thruster systems.
Condition: Unknown
Due 12 August 1998
Resolved 12 August 1998
Accommodation/Occupational Safety
Issued 30 April 1998 Resolved
Replace broken valve handle (wheel) on potable water tank suction valve in potable water room.
Condition: Unknown
Due 30 May 1998
Resolved 22 June 1998
Accommodation/Occupational Safety
Issued 30 April 1998 Resolved
Prove proper operation of all exterior and elevator public announcement speakers.
Condition: Unknown
Due 12 May 1998
Resolved 12 May 1998
Lifesaving
Issued 30 April 1998 Resolved
Provide 120 pound oscar dummy to be used for man-overboard drills.
Condition: Unknown
Due 30 May 1998
Resolved 22 June 1998
Fire Fighting
Issued 30 April 1998 Resolved
Prove proper operation of all port side exterior fire dampers.
Condition: Unknown
Due 30 May 1998
Resolved 22 June 1998
Electrical
Issued 30 April 1998 Resolved
Properly secure or remove hot wire (K-9) in stbd void fwd.
Condition: Unknown
Due 30 May 1998
Resolved 22 June 1998
Lifesaving
Issued 30 April 1998 Resolved
Install white reflective tape on 4th deck life rings.
Condition: Unknown
Due 30 May 1998
Resolved 22 June 1998
Electrical
Issued 11 February 1998 Resolved
Remove cashier (computer) wire from under rubber mat in 3rd deck bar.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Accommodation/Occupational Safety
Issued 4 November 1997 Resolved
Clean all exhaust ventilation registers throughout the vessel.
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Lifesaving
Issued 13 August 1997 Resolved
Install proper length of line for water lights installed to life buoys.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Accommodation/Occupational Safety
Issued 13 August 1997 Resolved
Provide MSD's for all cleaning lockers.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Electrical
Issued 13 August 1997 Resolved
Install electrical outlet covers in hard count.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Electrical
Issued 13 August 1997 Resolved
Remove outlet strips in slot office and casino managers office.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Electrical
Issued 13 August 1997 Resolved
Install "E" on all interior emergency lights on 2nd deck.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Electrical
Issued 13 August 1997 Resolved
Install "E" on all exterior emergency lights._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Lifesaving
Issued 13 August 1997 Resolved
Repair 2nd deck fwd phone.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Lifesaving
Issued 13 August 1997 Resolved
Repair 3rd deck port exterior fwd speaker.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Accommodation/Occupational Safety
Issued 13 August 1997 Resolved
Remove all plastic garbage cans.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Electrical
Issued 13 August 1997 Resolved
Remove power strip from vault.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Electrical
Issued 13 August 1997 Resolved
Complete circuit directory card for panel "Y" in hard count.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Electrical
Issued 13 August 1997 Resolved
Repair "E" light in hard count.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Electrical
Issued 3 May 1997 Resolved
Prove proper operation of all temporary (24vdc) emergency power lighting.
Condition: Unknown
Due 3 May 1997
Resolved 3 May 1997
Fire Fighting
Issued 3 May 1997 Resolved
Prove proper operation of fire screen doors #3 and #9.
Condition: Unknown
Due 2 June 1997
Resolved 6 May 1997
Accommodation/Occupational Safety
Issued 3 May 1997 Resolved
Provide filtration for 2nd and 3rd deck return air ductwork.
Condition: Unknown
Due 3 May 1997
Resolved 3 May 1997
Electrical
Issued 3 May 1997 Resolved
Remove temporary surge protectors from thye following spaces: 2nd deck cashiers cage, 2nd deck cigarette vending machine, 1st deck cigarette vending machine, Phone room, Surveilence room, Illinois gaming board office, Employee break room.
Condition: Unknown
Due 6 June 1997
Resolved 6 June 1997
Engineering
Issued 3 May 1997 Resolved
Repair MDE gear box oil leak IWO stbd MDE gear box oil switch.
Condition: Unknown
Due 3 May 1997
Resolved 3 May 1997
Engineering
Issued 3 May 1997 Resolved
Clean all MDE and SSG fuel filters.
Condition: Unknown
Due 6 June 1997
Resolved 6 June 1997
Electrical
Issued 3 May 1997 Resolved
Prove proper operatin of PA system under emergency power and dead ship condition.
Condition: Unknown
Due 3 May 1997
Resolved 3 May 1997
Navigation
Issued 3 May 1997 Resolved
Prove proper operation of steering gear room sound power phone.
Condition: Unknown
Due 6 June 1997
Resolved 6 June 1997
Fire Fighting
Issued 6 February 1997 Resolved
Ensure CG inspectors witness next halon witness next halon fixed f/f systemtesting/servicing_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Construction/Loadline
Issued 6 February 1997 Resolved
Mark all emergency egress hatches with operating instructions._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Lifesaving
Issued 6 February 1997 Resolved
Replace life rings on 03 deck.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Fire Fighting
Issued 6 February 1997 Resolved
REPLACE FIRE DAMPER CLOSED SIGN ON 02 DECK STBD SIDE
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Fire Fighting
Issued 6 February 1997 Resolved
ADJUST FOR PROPER OPERATION FIRE DAMPER O2 DECK STBD SIDE AFT.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Accommodation/Occupational Safety
Issued 6 February 1997 Resolved
Rplace all plastic trash cans.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Accommodation/Occupational Safety
Issued 6 February 1997 Resolved
Clean 01 deck bar.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Electrical
Issued 6 February 1997 Resolved
Completely fill out a circuit directory card in panel z 02 deck.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Accommodation/Occupational Safety
Issued 6 February 1997 Resolved
Adjust for proper operation WTD IWO mens head, main deck.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Lifesaving
Issued 5 November 1996 Resolved
Re-stencil life ring IWO second deck aft, stbd side.
Condition: Unknown
Due 5 December 1996
Resolved 6 December 1996
Lifesaving
Issued 5 November 1996 Resolved
Repair latch on lifejacket locker main deck aft.
Condition: Unknown
Due 5 December 1996
Resolved 6 December 1996
Electrical
Issued 5 November 1996 Resolved
Provide a circuit directory card for distribution panel "N".
Condition: Unknown
Due 5 December 1996
Resolved 6 December 1996
Construction/Loadline
Issued 5 November 1996 Resolved
Repair hydraulic oil leaks on #1A WTD.
Condition: Unknown
Due 5 December 1996
Resolved 6 December 1996
Electrical
Issued 5 November 1996 Resolved
Remove all temporary surge protectors in all cashier cages.
Condition: Unknown
Due 5 December 1996
Resolved 6 December 1996
Fire Fighting
Issued 5 November 1996 Resolved
Provide firefighting training to all deckhands on firefighting crew.
Condition: Unknown
Due 5 November 1996
Resolved 5 November 1996
Accommodation/Occupational Safety
Issued 5 November 1996 Resolved
Repair lock assembly on third deck employee door (port side).
Condition: Unknown
Due 5 December 1996
Resolved 6 December 1996
Documentation
Issued 5 November 1996 Resolved
Prior to taking on fuel, or getting underway provide proof of a current COFR.
Condition: Unknown
Due 7 November 1996
Resolved 6 December 1996
Electrical
Issued 5 November 1996 Resolved
Prove proper operation of #2 S/S Gen. Reverse Power Relay.
Condition: Unknown
Due 5 November 1996
Resolved 5 November 1996
Accommodation/Occupational Safety
Issued 5 November 1996 Resolved
Repair stuffing tubes IWO junction boxes on elevator reservior.
Condition: Unknown
Due 5 November 1996
Resolved 6 December 1996
Electrical
Issued 5 November 1996 Resolved
Install "E" letter emergency light on first deck bar aft and aft stbd door.
Condition: Unknown
Due 5 December 1996
Resolved 6 December 1996
Fire Fighting
Issued 5 November 1996 Resolved
Prove proper operation of FSD's #4, 1, 10.
Condition: Unknown
Due 5 December 1996
Resolved 6 December 1996
Accommodation/Occupational Safety
Issued 1 August 1996 Resolved
Repair or replace door 2nd deck, aft, stbd side.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Engineering
Issued 1 August 1996 Resolved
Prove proper operation of Bow Thruster water temperature gauge on engine.
Condition: Unknown
Due 4 September 1996
Resolved 15 August 1996
Accommodation/Occupational Safety
Issued 1 August 1996 Resolved
Repair door to forward crew space, 1st deck.
Condition: Unknown
Due 4 September 1996
Resolved 15 August 1996
Electrical
Issued 1 August 1996 Resolved
Lock all electrical panals in passenger spaces.
Condition: Unknown
Due 4 September 1996
Resolved 15 August 1996
Fire Fighting
Issued 1 August 1996 Resolved
Adjust or repair fire screen doors #1 and #5.
Condition: Unknown
Due 4 September 1996
Resolved 15 August 1996
Fire Fighting
Issued 1 August 1996 Resolved
Properly adjust fire dampers, 3rd deck, portside.
Condition: Unknown
Due 4 September 1996
Resolved 15 August 1996
Lifesaving
Issued 1 August 1996 Resolved
Remove combustible trash cans through out the passenger spaces.
Condition: Unknown
Due 4 September 1996
Resolved 15 August 1996
Electrical
Issued 1 August 1996 Resolved
Properly lable LTG panal "U", directory card, IWO security office.
Condition: Unknown
Due 4 September 1996
Resolved 15 August 1996
Electrical
Issued 1 August 1996 Resolved
Permanently install outlet 3rd deck Delli.
Condition: Unknown
Due 4 September 1996
Resolved 15 August 1996
Electrical
Issued 1 August 1996 Resolved
Properly lable blower motor conyroller in Bow Thruster space.
Condition: Unknown
Due 4 September 1996
Resolved 15 August 1996
Fire Fighting
Issued 3 May 1996 Resolved
REMOVE ALL LIQUOR FROM DISPENSING ROOM WHICH IS IN EXCESS OF DAILY USE LIMITS OR INSTALL SPRINKLER AND FIRE DETECTION SYSTEMS.
Condition: Unknown
Due 3 June 1996
Resolved 24 July 1996
Electrical
Issued 3 May 1996 Resolved
PROPERLY LABEL BREAKERS IN EDG PANEL "HH".
Condition: Unknown
Due 3 June 1996
Resolved 24 July 1996
Construction/Loadline
Issued 3 May 1996 Resolved
PROPERLY MARK PORT WING VOID W/"CONFINED SPACE-DO NOT ENTER" IN STEERING MOTOR ROOM.
Condition: Unknown
Due 3 June 1996
Resolved 24 July 1996
Electrical
Issued 3 May 1996 Resolved
REPLACE/REPAIR EMERGENCY LIGHTING IN EMS SPACE.
Condition: Unknown
Due 3 June 1996
Resolved 24 July 1996
Lifesaving
Issued 3 May 1996 Resolved
REMOVE/REPLACEHAMMER HYDROSTATIC RELEASE ON ALL LIFERAFTS
Condition: Unknown
Due 3 June 1996
Resolved 24 July 1996
Electrical
Issued 14 February 1996 Resolved
PROVE PROPER OPERATION OF #2 GENERATOR AND PRIME MOVER. VESSEL RESTRICTED TO DOCKSIDE PASSENGER OPERATIONS UNTIL CORRECTED.
Condition: Unknown
Due 14 February 1996
Resolved 14 February 1996
Fire Fighting
Issued 7 February 1996 Resolved
PROPERLY IDENTIFY FIRE STATION #14.
Condition: Unknown
Due 12 February 1996
Resolved 12 February 1996
Lifesaving
Issued 7 February 1996 Resolved
PROVIDE 90' LINE FOR THE TWO RING BOUY REQUIRED TO HAVE A LINE ATTACHED.
Condition: Unknown
Due 7 February 1996
Resolved 7 February 1996
Navigation
Issued 7 February 1996 Resolved
REPAIR LEAKING PORT STEERING RAM.
Condition: Unknown
Due 7 February 1996
Resolved 7 February 1996
Accommodation/Occupational Safety
Issued 7 February 1996 Resolved
PROPERLY MARK EMERGENCY ESCAPE IN VICINITY OF SLOT OFFICE.
Condition: Unknown
Due 12 February 1996
Resolved 12 February 1996
Lifesaving
Issued 7 February 1996 Resolved
REPLACE (2) WASTED RING BOUYS ON 4TH DECK.
Condition: Unknown
Due 12 February 1996
Resolved 12 February 1996
Electrical
Issued 7 February 1996 Resolved
PROVE PROPER OPERATION OF #1 (STBD) GENERATOR REVERSE POWER RELAY. PARALLELGENERATOR OPERATION PROHIBITED UNTIL CORRECTED.
Condition: Unknown
Due 7 February 1996
Resolved 7 February 1996
Lifesaving
Issued 1 November 1995 Resolved
REMOVE COMBUSTIBLE MATERIALS FROM PORT SIDE STAIR TOWER, MAIN DECK TO HOLD DECK.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Fire Fighting
Issued 1 November 1995 Resolved
PROVE PROPER OPERATION OF FSD #9
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Lifesaving
Issued 1 November 1995 Resolved
PREVENT FIRE STATION #8 DOOR FROM BLOCKING EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Accommodation/Occupational Safety
Issued 14 August 1995 Resolved
Properly mark all WTds on both sides of door or door frame. Amend fire plan accordingly.
Condition: Unknown
Due 14 August 1995
Resolved 14 August 1995
Engineering
Issued 3 May 1995 Resolved
PROVIDE PROOF OF HEATING BOILER SERVICE, I.E., RELIEF VALVE, SHUTDOWN, AND HYDRO TESTING, INTERNAL EXAMINATION.
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Lifesaving
Issued 3 May 1995 Resolved
MARK ALL MATS COVERING ESCAPE HATCH COVERS WITH APPROPRIATE NOTICE TO KEEP CLEAR.
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Fire Fighting
Issued 3 May 1995 Resolved
MAKE SPRINKLER HEAD TANK AVAILABLE FOR HYDROSTATIC TESTING, OR INTERNAL EXAMINATION.
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Documentation
Issued 3 May 1995 Resolved
UPDATE VESSEL OIL TRANSFER PROCEDURES WITH NEW FUEL PIPING/TANK DIAGRAM, AND SPECIAL INSTRUCTIONS CONCERNING TANK LEVELS.
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Lifesaving
Issued 17 February 1995 Resolved
PROVE RELIABILITY OF VESSEL RESCUE BOAT, VESSEL NOT TO GET UNDERWAY UNTIL SUCH TIME RESCUE BOAT IS PROVEN RELIABLE, OR OTHER APPROVED RESCUE BOATS ARE OBTAINED.
Condition: Unknown
Due 20 February 1995
Resolved 20 February 1995
Lifesaving
Issued 1 February 1995 Resolved
REPLACE DAMAGED RING BOUY, TOP DECK, PORT SIDE.
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Electrical
Issued 1 February 1995 Resolved
REPLACE "TEMPORARY" EXTENSION CORD WITH APPROVED HARD WIRING, CORD SUPPLIESEQUIPMENT LOCATED UNDER PILOT HOUSE, _x001C_
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Electrical
Issued 1 February 1995 Resolved
RERUN A/C COMPUTER CONTROL WIRING FROM CONTROLLER BOX, LOCATED BELOW PILOT HOUSE, THRU APPROVED BOX FITTINGS.
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Lifesaving
Issued 7 November 1994 Resolved
REPAIR BELL CRANK FOR BOW LOOKOUT'S SOUND POWERED PHONE.
Condition: Unknown
Due 7 November 1994
Resolved 7 November 1994
Electrical
Issued 7 November 1994 Resolved
PROVIDE PROPER/APPROVED MATERIAL I.E. FIRE STOP, ROX, CAULK, FOR THRU DECK PENETRATION AT PORT CORNER OF ENGINEROOM.
Condition: Unknown
Due 7 November 1994
Resolved 7 November 1994
Lifesaving
Issued 5 August 1994 Resolved
TROUBLESHOOT WEAK VOICE TRANSMISSION/RECEPTION IN VESSEL SOUND POWERED TELEPHONE SYSTEM.
Condition: Unknown
Due 5 August 1994
Resolved 5 August 1994
Lifesaving
Issued 5 August 1994 Resolved
REPLACE BURNT OUT BULB IN 3RD DECK FWD STBD EXIT LIGHT.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 5 August 1994 Resolved
REPAIR INDICATOR PANEL LIGHT ON BRIDGE PANEL FOR REMOTE INDICATOR LIGHT FORWATER TIGHT DOORS.
Condition: Unknown
Due 5 August 1994
Resolved 5 August 1994
Fire Fighting
Issued 5 August 1994 Resolved
PROVE PROPER OPERATION OF FSD #10, DOOR WILL NOT LATCH IN CLOSED POSITION AUTOMATICALLY.
Condition: Unknown
Due 5 August 1994
Resolved 5 August 1994
Deck/Cargo
Issued 3 May 1994 Resolved
CONTACT OCMI TO SCHEDULE ANCHOR DRILL.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Fire Fighting
Issued 3 May 1994 Resolved
TEST ALL VESSEL SMOKE DETECTORS IN ENGINEERING SPACES.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Unknown
Issued 3 May 1994 Resolved
PROVIDE [name withheld] WITH COPY OF VESSEL SPECIFIC EMERGENCY CONTINGENCY PLAN. ITEMS TO BE COVERED ARE IN INSPECTION DEPT POLICY LETTER 01-94 PROVIDED TO VESSEL REP.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Construction/Loadline
Issued 24 February 1994 Resolved
PROVE PROPER LOCAL OPERATION OF WTD AT FRAME 44.
Condition: Unknown
Due 24 February 1994
Resolved 24 February 1994
Electrical
Issued 22 December 1993 Resolved
TEST SHIP SERVICE GENERATOR OVERSPEED TRIP AND OTHER ASSOCIATED SHUTDOWNS IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 22 December 1993
Resolved 22 December 1993
Fire Fighting
Issued 9 September 1993 Resolved
PROVIDE INFORMATION TO USCG MARINE SAFETY CENTER CONCERNING COMPLETE AND CORRECT BILL OF MATERIALS FOR SPRINKLER SYSTEM AS PER MSC LTR DTD 07JUL93 SERIAL NUMBER M-30372.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Fire Fighting
Issued 9 September 1993 Resolved
PROVIDE INFORMATION TO USCG MARINE SAFETY CENTER CONCERNING SPRINKLER SYSTEM HEAD TANK AS PER MSC LTR DTD 07JUL93 SERIAL NUMBER M-30263.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Fire Fighting
Issued 9 September 1993 Resolved
RECHARGE HALON BOTTLE IN EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Engineering
Issued 9 September 1993 Resolved
PROVIDE TO COAST GUARD MARINE SAFETY CENTER INFORMATION ON AIR DAMPER CONTROL FLUID FOR VESSEL'S BOILER AS PER MSC LTR DTD 10MAY93 SERIAL NUMBER M-30246.
Condition: Unknown
Due 9 October 1993
Resolved 20 September 1993
Electrical
Issued 9 September 1993 Resolved
PER MSC LTR DTD 01MAR93 SERIAL NUMBER E-30090 PROVIDE INFORMATION TO [name withheld] THAT CABLE FOR POWER DISTRIBUTION TO PANELS IS EITHER UL APPROVEDFOR SHIPBOARD USE OR MEETS 46 CFR 111.60.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Lifesaving
Issued 5 May 1993 Resolved
PRIOR TO CARRYING PASSENGERS, CONDUCT FIRE AND BOAT DRILL IN PRESENCE OF COGNIZANT OCMI.
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Documentation
Issued 5 May 1993 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE AND POST ORIGINAL STABILITY LETTER INPILOTHOUSE. (46 CFR 78.12-1)
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Documentation
Issued 5 May 1993 Resolved
POST ALL REQUIRED CERTIFICATES AND LICENCES IN PILOTHOUSE. (46 CFR 71.01-5)
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Fire Fighting
Issued 5 May 1993 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE AND POST PERMANENT, APPROVED FIRE CONTROL PLAN. (46 CFR 78.45)
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Accommodation/Occupational Safety
Issued 5 May 1993 Resolved
REMOVE TEMPORARY RANGES, REFRIGERATOR AND ASSOCIATED TEMPORARY WIRING FROM DEALER'S LOUNGE UPON ARRIVAL IN ALTON, IL.
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Engineering
Issued 5 May 1993 Resolved
PROVIDE APPROVED PLANS FOR BOILER AND BOILER AUTOMATION TEST PROCEDURE. REFER TO MARINE SAFETY CENTER COMMENT LETTER DATED 22MAR93. (46 CFR 71.65)
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Fire Fighting
Issued 5 May 1993 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE AND POST IN PILOTHOUSE ADJACENT TO SPRINKLER SYSTEM ALARM PANEL, A DIAGRAM OR CHART INDICATING LOCATION OF DETECTING ZONES AND TESTING OF SYSTEM. (46 CFR 76.25-35 (J))
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Documentation
Issued 5 May 1993 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE APPROVED PLANS AND SATISFY ALL RELATED COMMENT LETTERS FROM MARINE SAFETY CENTER CONCERNING AUTOMATIC SPRINKLER SYSTEM. SYSTEM INSTALLED IN ACCORDANCE WITH PLAN 2118 SHEET 1, REV 3 AND SHEET 2, REV 5. (46 CFR 71.65)
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Lifesaving
Issued 5 May 1993 Resolved
PRIOR TO CARRYING PASSENGERS, INSTALL AND PROVE PROPER OPERATION OF ELEVATOR TELEPHONE SYSTEM IN ACCORDANCE WITH ASME A17.1A CODE FOR ELEVATORS.
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Fire Fighting
Issued 5 May 1993 Resolved
PRIOR TO CARRYING PASSENGERS, INSTALL AND PROVE PROPER OPERATION OF SPRINKLER SYSTEM PRESSURE TANK LOW PRESSURE ALARM. (46 CFR 76.25-20)
Condition: Unknown
Due 7 May 1993
Resolved 7 May 1993
Fire Fighting
Issued 5 May 1993 Resolved
PRIOR TO CARRYING PASSENGERS, INSTALL AND PROVE PROPER OPERATION OF ENGINEROOM SPRINKLER SYSTEM AUDIBLE ALARM FOR FIRE INDICATION AND SYSTEM TROUBLE. (46 CFR 76.25-35)
Condition: Unknown
Due 7 May 1993
Resolved 7 May 1993
Documentation
Issued 5 May 1993 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE APPROVED PLANS AND SATISFY ALL RELATED COMMENT LETTERS FROM MARINE SAFETY CENTER CONCERNING ELEVATOR INSTALLATION. (46 CFR 71.65)
Condition: Unknown
Due 7 May 1993
Resolved 7 May 1993
Navigation
Issued 5 May 1993 Resolved
INSTALL AND PROVE PROPER OPERATION OF POTABLE WATER PRESSURE VESSEL RELIEF VALVES. MAXIMUM RELIEF VALVE SETTING IS 100 PSI. (46 CFR 54.15-5)
Condition: Unknown
Due 7 May 1993
Resolved 7 May 1993
Documentation
Issued 5 May 1993 Resolved
PROVIDE AND POST ORIGINAL FCC RADIO LICENCE. (46 CFR 71.20-15)
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993

Casualty record · 2

2 March 2008Routine · role: Involved in a Marine Casualty · 1 injured · activity 3295548
25 February 2013Routine · role: Involved in a Marine Casualty · activity 4539049
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.