Records from 2005 to 2026. Most recent: inspection, 28 July 2026.
Inspection history · 24
28 July 2026
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8448429
12 August 2025
Type not recorded
No type recorded · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8215341
27 May 2025
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8144412
10 April 2025
In-Service Inspection · Examination of Repairs · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8109831
2 May 2024
Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 7905051
21 June 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7719523
25 April 2023
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7675012
3 May 2022
Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7440452
3 March 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7411894
22 November 2021
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7356123
13 July 2021
Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7283241
5 May 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7188658
23 June 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6985168
30 December 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6880826
29 October 2019
Drydock Exam · Deficiency Check · Administrative Inspection · Internal Structural Exam · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6844139
9 September 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6807891
18 July 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6754347
3 June 2019
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6702807
2 May 2019
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6675314
14 June 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6445387
8 November 2017
Internal Structural Exam · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6308775
5 May 2017
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6137717
20 July 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6024280
21 May 2016
Hull Examination · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5913837
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 May 2025
Resolved
Vessel is required to ensure the EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. Vessel's EPIRB battery was past its expiration date. Owner installed new CAT I EPIRB with registration completed to satisfaction of attending Coast Guard Marine Inspector during inspection. No further requirements. 46 CFR 185.728(b)
Action required: 10 - Deficiency Rectified
Resolved 27 May 2025
Resolution: New EPIRB installed. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 2 May 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Broken yellow wire found in engine compartment.
46 CFR 183.200 (c)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 20 May 2024
Resolution: New wire installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 May 2024
Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. The starboard engine room has a cable penetration on the bulkhead that is not vapor tight. Provide a proper seal to prevent the passage of vapors.
46 CFR 177.405 (c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2024
Resolved 20 May 2024
Resolution: Proper barrier installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 May 2024
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. Countless wires supported with use of plastic zip ties.
46 CFR 183.340 (b)(4)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2024
Resolved 20 May 2024
Resolution: Supports provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 June 2023
Resolved
The EPIRB test required shall be logged or otherwise documented monthly. Vessel unable to provide log for EPIRB tests. Provide monthly EPIRB test log.
46 CFR 185.728(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2023
Resolved 20 July 2023
Resolution: EPIRB test log provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 June 2023
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and scenario and training topics. Vessel unable to provide drill/training logs. Provide drill/training logs.
46 CFR 185.520(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2023
Resolved 20 July 2023
Resolution: Drill and training log provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 June 2023
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Wires found unsupported. Provide support every 24 inches for wires.
46 CFR 183.340 (b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2023
Resolved 20 July 2023
Resolution: Wire suppported.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 June 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. J-box was not mounted and floating in space. Mount electrical J-box.
46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2023
Resolved 20 July 2023
Resolution: J-box mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 June 2023
Resolved
In systems and applications where flexible hoses are permitted to be clamped: Double hose clamping is required. Missing double hose clamps on bilge pump suction and discharge. Provide double hose clamps.
46 CFR 182.410 (d) (1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2023
Resolved 20 July 2023
Resolution: Double hose clamp provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 3 May 2022
Resolved
FCC requires mariners that operate a vessel with more than 6 passengers to have a valid FCC Marine Radio Operator Permit(MROP). Vessel master did not have FCC MROP. Master shall provide MROP.
47 CFR 13.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 21 May 2022
Resolution: MROP Provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 May 2022
Resolved
Stern navigation light shall show an unbroken light 67.5 degrees from right aft on each side of the vessel. Stern light obstructed in current location by sugar scoops. Provide new position for stern light to show full light. Vessel restricted to daytime ops until operational.
33 CFR 83.21
Action required: 705 - Other - as specified
Resolved 21 May 2022
Resolution: Stern nav light moved to unobstructed position.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 May 2022
Resolved
Spanner wrench must be provided where a 1.5 inch hose is required. Vessel does not have a spanner wrench. Provide spanner wrench.
46 CFR 181.310(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 21 May 2022
Resolution: Spanner wrench provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 May 2022
Resolved
Each fire nozzle must be capable of being changed between a solid stream pattern and a spray pattern. Starboard side fire Nozzle was clogged not allowing sufficient flow or to switch stream patterns. Secondary fire station and hose operational to all areas on vessel. Provide operational fire nozzle.
46 CFR 181.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 21 May 2022
Resolution: Nozzel operational.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 May 2022
Resolved
The floating water light for the life float must be attached to the float by a line of at least 18 feet. Line was approximately 6 feet. Provide 18 feet of line.
46 CFR 180.175
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 21 May 2022
Resolution: Line provided for light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2022
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Crew could not pump water from spaces using installed piped system and engine driven bilge pump. Provide operational bilge pumping system.
46 CFR 182.510
Action required: 10 - Deficiency Rectified
Resolved 3 May 2022
Resolution: Bilge pump operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2022
Resolved
The materials of rigging on a sailing vessel must be suitable for the intended purpose. 03 bolts showing running rust on baby stay chain plate and starboard diamond chain plate has rusted washer. Replace corroded items and ensure no damage to chain plates.
46 CFR 177.330
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 21 May 2022
Resolution: Chain plates cleaned.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 July 2021
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Provide proof of pre-employment tests or acceptable alternative as required by this cite for individuals in a safety sensitive position.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 9 September 2021
Resolution: DER provided proof of documentation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 July 2021
Resolved
Provide copy of contract or proof of enrollment in Consortium; and provide Letter of Regulatory Compliance for RDTS consortium.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 10 August 2021
Resolution: DER provided required documentation from third party consortium.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 May 2021
Resolved
Child and adult life jackets located in same space. Provide segregation from child and adult life jackets. Ensure storage marking is appropriately marking each number of adult and child life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2021
Resolved 1 June 2021
Resolution: Life jackets seperated and marked.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 May 2021
Resolved
Flammable liquids onboard. Remove all flammable materials or provide approved paint/hazmat locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2021
Resolved 1 June 2021
Resolution: Flammables removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 May 2021
Resolved
Remove dead end wire and 5th terminal from unknown load at battery post.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2021
Resolved 1 June 2021
Resolution: Dead end wire removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 May 2021
Resolved
Fuel shut off marking missing for starboard engine room. Provide fuel shut off marking with 1 inch lettering.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2021
Resolved 1 June 2021
Resolution: Fuel shut off marking provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 May 2021
Resolved
Starboard side exhaust missing second band clamp. Provide double clamping on exhaust at all connection points.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2021
Resolved 1 June 2021
Resolution: Band clamp provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 May 2021
Resolved
Bolts on port side collision bulkhead manhole cover missing. Provide bolts for each hole in collision bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2021
Resolved 1 June 2021
Resolution: Bolts provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2021
Resolved
Provide photos and report of past furler opening inspection in accordance with Preventative Maintenance plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2021
Resolved 1 June 2021
Resolution: Furler photos provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2021
Resolved
Provide sail rigging Preventative Maintenance Plan to [name withheld] for vessel files.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2021
Resolved 1 June 2021
Resolution: PMP Provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 May 2021
Resolved
Missing paper chart. Provide updated chart for area being transited.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2021
Resolved 1 June 2021
Resolution: Charts provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 June 2020
Resolved
Test remote operated fuel valves in accordance with 46 CFR 176.804. Port remote operated fuel valve did not close completely.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2020
Resolved 23 June 2020
Resolution: Video provided showing satisfactory operation.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 29 October 2019
Resolved
All fuel tanks must be electrically bonded to a common ground. Ground on port fuel tank detached.
46 CFR 182.440 (b)(3)
Action required: 705 - Other - as specified
Resolved 12 November 2019
Resolution: Port fuel tank was electrically bonded.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 July 2019
Resolved
Components of rigging are overdue for renewal as outlined in NVIC 02-16 Sail Rigging. Vessel is due for scheduled drydock 19 Nov. Conduct monthly third party inspections of rigging and renew overdue components at Nov 2019 drydock in accordance with 46 CFR 176.840.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 9 September 2019
Resolution: Vessel voluntarily removed from passenger service by company.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 July 2019
Resolved
Vessel Rigging Preventative Maintenance Plan is missing description of maintenance tasks. Provide in accordance with 46 CFR 176.840.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2019
Resolved 9 September 2019
Resolution: Task description provided.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 18 July 2019
Resolved
Weak links for three life floats were oversized. Provide correct weak links in accordance with 46 CFR 180.137.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2019
Resolved 9 September 2019
Resolution: Correct weak links provided.
Operations/Management › Vessel Activity › Underway
Issued 17 November 2017
Resolved
Vessel needs to complete satisfactory sea trials under sail propulsion witnessed by an attending USCG Marine Inspector or a accredited rig smith.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2017
Resolved 18 November 2017
Resolution: Vessel completed satisfactory sea trials under sail propulsion with an attending USCG Marine Inspector.