Inspection history · 34
5 July 2018
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6467422
11 December 2014
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5038295
14 March 2014
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4816025
14 March 2014
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4816031
30 August 2013
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4693013
20 June 2013
SIP Inspection/Audit
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4618398
21 June 2012
DAPI Audit · SIP Inspection/Audit
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4343523
20 October 2011
Deficiency Check · SIP Inspection/Audit
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4172131
21 September 2011
Simplified Stability Test
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4150880
21 May 2010
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3801616
26 May 2009
COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3486413
6 November 2008
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3359114
25 September 2008
Drydock Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3339721
26 September 2007
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3071364
18 July 2007
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2999699
5 June 2006
Annual Inspection · SIP Initial Entry
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2653457
11 August 2005
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2449025
29 June 2005
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2399365
14 April 2004
COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2042648
14 April 2004
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2868411
23 March 2004
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2030602
10 November 1999
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 805310
9 April 1998
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1406307
28 January 1998
Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1454515
15 September 1997
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1421402
10 February 1997
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1103573
22 January 1997
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1099861
13 August 1996
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1088718
14 September 1995
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 881436
20 July 1994
Deficiency Check · Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 866314
2 June 1993
Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 839220
2 June 1993
Initial Certification
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1353474
14 May 1993
Plan Review "T" Boat
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 841835
28 April 1993
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1148766
Construction/Loadline › Structures › Manhole
Issued 20 September 2013
Resolved
Provide captive chains in way of all water tight hatches on the main deck in accordance with 46 CFR 179.360(b)(2).
Action required: 705 - Other - as specified
Due 20 October 2013
Resolved 14 March 2014
Resolution: Captive chains installed and inspected satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 September 2013
Resolved
Remove all plastic wire ties for all wire runs in all the interior voids of the vessel. All wire runs must be secured with metallic fasteners and be spaced not more than 24 inches apart in accordance with 46 CFR 183.340(b)(4).
Action required: 705 - Other - as specified
Due 20 October 2013
Resolved 14 March 2014
Resolution: Metallic fasteners were used to properly secure all wire runs.
Construction/Loadline › Penetrations › Pipe Flange
Issued 20 September 2013
Resolved
Renew the wasted drain line in way of the channel for void #5 where the horizontal door is secured. The pipe is completed wasted and serves as a drain for the horizontal door channel which exits out the stern rake.
Action required: 705 - Other - as specified
Due 20 October 2013
Resolved 14 March 2014
Resolution: Drain line was renewed and found satisfactory.
Construction/Loadline › Hull › Sheerstrake
Issued 20 September 2013
Resolved
Make necessary repairs to the starboard side bow platform area where the vessel had been previously damaged. Areas that need to be addressed include the separation/crack on deck strake on the starboard bow where it is joined to the starboard deck sheer strake, several tripped frames and two areas where the deck is buckled and peeled back.
Action required: 705 - Other - as specified
Due 20 October 2013
Resolved 14 March 2014
Resolution: Sufficient repairs were conducted to the starboard side bow.
Lifesaving › Lifejacket/PFD (Type IV) › Condition
Issued 26 May 2009
Resolved
Have lifesaving equipment inspected prior to caring passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2011
Resolved 20 October 2011
Resolution: Lifesaving equipment was inspected and found satisfactory.
Construction/Loadline › Hull › Hull Plating
Issued 25 September 2008
Resolved
Vessel had a inset of 2" X 8" on the Port bow corner due to prior damage.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 6 November 2008
Resolution: Area was inserted and repaired
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 July 2007
Resolved
Install high level bilge alarm
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2011
Resolved 20 October 2011
Resolution: Tested bilge high level alarm in aft void satisfactory.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 August 2005
Resolved
Install donning instructions for Lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2005
Resolution: Installed instructions.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 August 2005
Resolved
Prove proper operations of self-igniting light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2005
Resolution: Replace Batteries.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 April 2004
Resolved
Provide copy of current certificate of documentation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2004
Resolved 14 April 2004
Resolution: Received certified to be a true copy from vessel documentation center.
Documentation › Logs/Records
Issued 14 April 2004
Resolved
Provide proof of user fee payment.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2004
Resolved 14 April 2004
Resolution: Received fax from user fee center entered credit card number and faxed back to user fee center.
Engineering
Issued 13 August 1996
Resolved
LABEL THE EMERGENCY FUEL CUT OFF.
Condition: Unknown
Due 23 October 1996
Resolved 23 October 1996
Engineering
Issued 13 August 1996
Resolved
POST AN OIL POLLUTION PLACARD.
Condition: Unknown
Due 23 October 1996
Resolved 23 October 1996
Lifesaving
Issued 13 August 1996
Resolved
POST LIFE JACKET DONNING INSTRUCTIONS IN ACCORDANCE WITH 46 CFR 185.516.
Condition: Unknown
Due 23 October 1996
Resolved 23 October 1996
Electrical
Issued 13 August 1996
Resolved
EFFECT PERMANENT REPAIRS TO THE S/S GENERATOR. PROVE PROPER OPERATION WHENCOMPLETE. THE VESSEL SHALL NOT CARRY PASSENGERS PRIOR TO COMPLETING REPAIRS AND TESTS TO THE SATISFACTION OF THE COGNIZANT USCG MARINE INSPECTOR.
Condition: Unknown
Due 13 August 1996
Resolved 13 August 1996
Construction/Loadline
Issued 13 August 1996
Resolved
CORRECT CLEARANCE BETWEEN BILGE SUCTION AND BOTTOM PLATE IN THE #1 AND #2 VOIDS.
Condition: Unknown
Due 23 October 1996
Resolved 23 October 1996
Lifesaving
Issued 13 August 1996
Resolved
PROVIDE 2 ADDITIONAL ADULT SIZE PFD'S. (CORRECTED ON SCENE)
Condition: Unknown
Due 23 October 1996
Resolved 23 October 1996
Lifesaving
Issued 13 August 1996
Resolved
POST EMERGENCY INSTRUCTIONS IN ACCORDANCE WITH 46 CFR 185.25-1.
Condition: Unknown
Due 23 October 1996
Resolved 23 October 1996
Lifesaving
Issued 20 July 1994
Resolved
CLEAN AND/OR REMOVE OIL SOAKED ANCHOR LINE AFT MACHINERY SPACE.
Condition: Unknown
Due 31 July 1994
Resolved 10 August 1994
Construction/Loadline
Issued 20 July 1994
Resolved
RE-ATTACH MISSING VENT PIPE TO FWD (PORT SIDE) RAKE DECK FITTING.
Condition: Unknown
Due 31 July 1994
Resolved 10 August 1994
Lifesaving
Issued 2 June 1993
Resolved
VSL IS LIMITED TO THE CARRIAGE OF 100 PASSENGERS UNTIL PROPER PERMANENT STOWAGE AND LABELING OF ADDITIONAL PERSONAL FLOTATION DEVICES ARE PROVIDED TO THE SATISFACTION OF AN ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Electrical
Issued 2 June 1993
Resolved
PROVIDE A SATISFACTORY DRIP SHIELD FOR ELECTRICAL BOX, TO PREVENT POSSIBLE WATER DRAINAGE ON ELECTRICAL CONNECTIONS, NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 2 July 1993
Resolved 11 June 1993
Electrical
Issued 2 June 1993
Resolved
DEMONSTRATE PROPER OPERATION OF EMERGENCY GENERATOR, TO THE SATISFACTION OFAN ATTENDING COAST GUARD MARINE INSPECTOR, NO LATER THAN COMPLIANCE DATE. GENERATOR MAY NOT BE USED WHILE CARRYING PASSENGERS, UNTIL THIS REQUIREMENTIS SATISFIED.
Condition: Unknown
Due 2 July 1993
Resolved 9 September 1993