SAFETY LEADER

SAFETY LEADER is a 1993 towing vessel. The Coast Guard has recorded 24 inspections since 1996, most recently in January 2026, along with 16 deficiencies and 3 casualty investigations between 2006 and 2016.

Records from 1996 to 2026. Most recent: inspection, 7 January 2026.

Built
1993
Last inspected
7 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD2750
388143
Flag
UNITED STATES
367119410
Maury page id
psix-388143

Inspections, by type

…with no type recorded11
Years with a record 17 calendar years (1996–2026)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)66.0 ft × 24.0 ft × 8.0 ft
Registered tonnagegross 106 / net 85
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTEINER SHIPYARD INC · BAYOU LA BATRE, AL, UNITED STATES · built 1993
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 June 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it106 - Simplified, Gross Ton
85 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD2750MMSI 367119410 · active · compulsorily equipped · granted 26 March 2026, expires 6 June 2036
WDI4587MMSI 367119410 · cancelled · compulsorily equipped · granted 30 October 2015, cancelled 3 December 2015
WDC5913MMSI 367048360 · expired · compulsorily equipped · granted 8 June 2005, cancelled 8 August 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MON TA Towing Vessel · MISLE 1164426 · 27 March 2016 · activity 5842218CHEM 3252 Tank Barge · MISLE 1261065 · 27 March 2016 · activity 5842218CHEM 3255 Tank Barge · MISLE 1283834 · 27 March 2016 · activity 5842218ML 506 B Freight Barge · MISLE 163195 · 8 February 2006 · activity 2634634

Inspection history · 24

7 January 2026 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8276397
22 January 2025 COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8054262
27 September 2024 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7987768
10 January 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7847690
6 February 2023 Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7619508
12 January 2022 Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7379575
7 April 2021 Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7174379
30 September 2019 Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6826457
18 September 2017 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6269575
27 March 2016 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5842218
10 February 2011 DAPI Audit · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3943453
15 May 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3802099
7 November 2006 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2816429
2 October 2006 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2791555
19 April 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2628069
8 February 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2634634
20 June 2005 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2396710
28 March 2002 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1598492
6 March 2002 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1493150
13 July 2001 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 756653
8 July 2001 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 189959
1 May 1997 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 403617
2 July 1996 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 756380
17 June 1996 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 203148

Deficiency record · 16

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 January 2026 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: Low hydraulic steering fluid levels. Alarms must: (1) Be visible and audible at each operating station.46 CFR 143.230. No visible alarm for hydraulic oil low level. Make repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 February 2026
Resolution: Provided objective evidence of repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 January 2024 Resolved
The crew of each towing vessel must demonstrate the ability to operate the primary machinery for which they are responsible and do so under normal emergency conditions. The engines were not serviceable at the time of inspection and should be tested in the presence of an attending Coast Guard Marine Inspector. 46 CFR 143.205(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2024
Resolved 4 April 2024
Resolution: Inpected sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 January 2024 Resolved
The main engines must be equipped with proper gauging to ensure an emergency situation does not exist. Due to engine overhaul, the main engines onboard were not equipped with working gauges. Gauges must meet regulatory standards in the presence of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2024
Resolved 4 April 2024
Resolution: Inspected sat.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 10 January 2024 Resolved
Each towing vessel must be fitted with a general alarm that is capable of notifying persons in any accommodation, work space, and the engine room. A supplemental flashing red light must be installed in the engine room. The flashing red light was not working properly and the general alarm did not consistently sound due to battery power failure. 46 CFR 143.235(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2024
Resolved 4 April 2024
Resolution: Inspected sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 January 2024 Resolved
Emergency lighting must be provided for all internal crew working areas. The engine room did not have working emergency lighting. Install emergency lighting to the satisfaction of the attending marine inspector. 46 CFR 143.410(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2024
Resolved 4 April 2024
Resolution: Inspected sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2023 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings and electrical equipment and systems, must: be maintained to ensure proper operation. Shaft packing for both main engines was found leaking significantly. Repair shaft packing to the satisfaction of an attending Marine Inspector. 46 CFR 143.205(c)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 20 February 2023
Resolution: Inspected sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 February 2023 Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Upper centerline wire run had dead ended wires. Remove dead ended wires to the satisfaction of an attending Marine Inspector. 46 CFR 143.400(g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 20 February 2024
Resolution: Inspected sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 February 2023 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Machinery space emergency lighting was non operational. Repair/replace emergency lighting to the satisfaction of an attending Marine Inspector. 46 CFR 143.410(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 20 February 2023
Resolution: Inspected sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 February 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for the safe operation of the towing vessel. Multiple engine gauges were non operational from the operating station. Repair to the satisfaction of an attending Marine Inspector. 46 CFR 143.205(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 20 February 2023
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 7 April 2021 Resolved
Provide closures for engine room ventilation louvers for use in the event of a fire.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2021
Resolved 3 May 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 April 2021 Resolved
Attach a lanyard to bell striker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2021
Resolved 3 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 April 2021 Resolved
Label all PFD stowage areas properly, to include number of lifejackets stowed in particular location.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2021
Resolved 3 May 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 April 2021 Resolved
Place a first aid kit on board vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2021
Resolved 3 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 April 2021 Resolved
Designate and properly mark any container that is used for the stowage of work vests. Work vests may not be stowed with PFDs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2021
Resolved 3 May 2021
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 7 April 2021 Resolved
Clean engine room ventilation louvers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2021
Resolved 3 May 2021
Communications › Alarms/Indicators › General Alarm
Issued 7 November 2006 Resolved
General Alarm supplemental light in the engine room not working and associated placard with light missing.
Condition: Unknown
Due 9 November 2006
Resolved 9 November 2006
Resolution: Fuse and light bulb replaced

Casualty record · 3

8 February 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2634634
15 May 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3802099
27 March 2016Routine · role: Transiting Vicinity of Primary Subject · activity 5842218
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.