MAURY USCG vessel records
← All vessels

NORWEGIAN STAR

NORWEGIAN STAR is a 2001 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2017, most recently in February 2026, along with 19 deficiencies and 2 operational controls.

Records from 2017 to 2026. Most recent: inspection, 2 February 2026.

Built
2001
Last inspected
2 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 February 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9195157
Flag
BAHAMAS, THE
Maury page id
psix-38848

Documentation record

Tonnage as PSIX records it61087 - Convention (Subpart B), Net Ton
10039 - Dead Weight, Ton
50259 - Displacement, Ton
91740 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

2 February 2026 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8304805
15 January 2026 Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8296601
12 July 2025 PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8182631
13 July 2024 Deficiency Check · PSC A · COC-CVE Initial
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7952926
27 June 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7943516
14 April 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6939132
8 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6937159
6 December 2019 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6865840
9 March 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6663910
1 December 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6590327
19 November 2018 Ballast Water Examination · COC-CVE Annual · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6581874
5 January 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6334478
20 November 2017 Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6307926

Deficiency record · 19

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 January 2026 Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions. PSCO observed a gap between the frame and bulkhead for a B-15 fire door across from cabin 9036 and a partially detached handle on B-15 arcade door on deck 12. 74 SOLAS (97) II-2/31.1 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 2 February 2026
Resolution: Received class report attesting to satisfactory repair.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 January 2026 Resolved
The company should establish procedures to ensure that the ship is maintained in confonnity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. PSCO observed a lack of safety culture identified by watertight door operation knowledge gap, location of EEBD knowledge gap, international shore connection operation knowledge gap, and an active Hydrogen Sulfide leak identified by marine inspector via 4gas meter alarm and pungent rotten egg odor. A safety management external audit carried out by the administration or the RO, with a corresponding report of findings satisfactory to the OCMI, must be submitted prior to clearing this deficiency. 74 SOLAS (20)IX/3.1 ISM Code A.10.1 50abc
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2026
Resolved 16 April 2026
Resolution: Received satisfactory external audit report.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 15 January 2026 Resolved
Each passenger stateroom and crew cabin shall be equipped with entry doors that include peep holes or other means of visual identification. PSCO observed inoperable peep holes in cabins 10538, 10682, 8650. 46 USC 3507 (a)(1)(B) 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 2 February 2026
Resolution: Received class report attesting to satisfactory repair.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 January 2026 Resolved
In addition to the emergency lighting, the means of escape, including stairways and exits, shall be marked by lighting of photoluminescent strip indicators placed not more than 0.3 m (300mm) above the deck at all points of the escape route including angles and intersections. The marking must enable passengers to identify all the routes of escape and readily identify escape exits. PSCO observed inoperable low location lighting beneath the B-15 fire door across from cabin 9036. 74 SOLAS (97) II-2/28.1.10 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 2 February 2026
Resolution: Received class report attesting to satisfactory repair.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 15 January 2026 Resolved
Companies, masters, and crew members each have responsibility to ensure that each crew member can make a knowledgeable and informed contribution to the safe operation of the ship. PSCO observed crew member unknowledgeable on the operation of watertight doors. STCW 2017 A-1/14.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 January 2026
Resolution: Corrected during exam.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 January 2026 Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed frayed electrical gland in engine room adjacent to potable water compressor 7. 74 SOLAS (04)II-1/40.1.3 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 January 2026
Resolution: Corrected during exam.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 15 January 2026 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II- I/42 or II- I/43. PSCO observed four emergency embarkation lights on the starboard side of the vessel inoperable. 74 SOLAS (97) III/11.4 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 January 2026
Resolution: Corrected during exam.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 January 2026 Resolved
Fire hoses shall be of non-perishable material approved by the Administration and shall be sufficient in length to project a jet of water to any of the spaces in which they may be required to be used. Each hose shall be provided with a nozzle and the necessary couplings. In interior locations in passenger ships carrying more than 36 passengers fire hoses shall be connected to the hydrants at all times. PSCO observed missing spanner wrench at fire station FST01-5-28 and FST01-5-25. 74 SOLAS (97) II-2/4.7.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 January 2026
Resolution: Corrected during exam.
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 15 January 2026 Resolved
Ships of 500 gross tonnage and upwards shall be provided with at least one international shore connection complying with the provisions of paragraph 3. PSCO observed a lack of crew knowledge on the utilization of the international shore connection. 74 SOLAS (97) II-2/19.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 January 2026
Resolution: Corrected during exam.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 15 January 2026 Resolved
The company should establish procedures to ensure that new personnel are given proper familiarization with their duties. Instructions which are essential to be provided prior to sailing should be identified, documented and given. PSCO observed a lack of knowledge on EEBD location in the engine room. 74 SOLAS (20) IX/3.1 ISM Code A.6.3 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 January 2026
Resolution: Corrected during exam.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 January 2026 Resolved
All waste-receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. PSCO observed combustible waste receptacle in galley. 74 SOLAS (97) II-2/18.5 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 January 2026
Resolution: Corrected during exam.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 July 2024 Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall be capable of remote and automatic release from a continuously manned central control station, either simultaneously or in groups, and also individually from a position at both sides of the door. PSCO observed during fire-drill 14 remote released fire doors remained in open condition. 74 SOLAS 97 II-2/30.4.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2024
Resolution: Def cleared on the spot after verification of repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Stowage incl. uprights, lashing, etc. (timber)
Issued 13 July 2024 Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or other equivalent material, permanently and strongly attached to the bulkhead, and framed, stiffened and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead. PSCO observed weather tight door AC-5-13 with a crack at the bottom of the doors frame. ICLL 66/88 Reg. 12(1)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 August 2024
Resolution: Received class report and condition of class attesting to temporary repair on weathertight door.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 July 2024 Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing and shall have an approximately uniform rate of closure no more than 40s and no less than 10s. PSCO observed fire door 11-7-057 mens sauna did not close upon manual release but indicated closed on bridge. 74 SOLAS 97 II-2/30.4.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 August 2024
Resolution: Recieved class report attesting to the repairs of the sauna door.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 December 2019 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. Electrical breaker panel 61204/02 in deck 12 galley has uncovered breaker slots and pipe above is leaking water on to panel. 74 SOLAS (04) II-1/40.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2019
Resolved 14 April 2020
Resolution: Repaired / Rectified: Open slots have been covered. Condensation from chilled water pipes on top of panel has been corrected by replacing the Armaflex insulation. Class report dated 12/06/19.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 6 December 2019 Resolved
A line-throwing appliance complying with the requirements of section 7.1 of the Code Shall be provided. Pyrotechnics for all line-throwing appliances were expired. 74 SOLAS (97) III/18
Action required: 10 - Deficiency Rectified
Due 6 December 2019
Resolved 6 December 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 November 2018 Resolved
0999 - Other (safety in general) - The machinery associated piping system and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so instaled and protected as to reduce to a minimum any danger to persons onboard. PSCO had H2S alarm in compartment 13 starboard side deck 1. The ventilation for the marinfloc bilge water treatment system is ventilating into the space. - 74 SOLAS (04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 November 2018
Resolved 19 November 2018
Resolution: Ventilation was hard piped outside of the space.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 November 2018 Resolved
0750 - Fire door - The contruction of all doors and door frames in "A" class division shall provide resistance to fire as well as to the passage of smoke and flame. Roller shutter on deck 13, fire zone 4 grill was unable to close - 74 SOLAS (97) II-2/30.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2018
Resolved 1 December 2018
Resolution: November 30th, 2018, [name withheld] from DNV-GL attended the vessel and certified the repair of the subject deficiency, issuing a report, closing the CA 634. Class Report attached in documents.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 November 2018 Resolved
0715 - Fire detection - Fire protection systems and fire-fighting systems and appliances shall be maintained and ready for use. Smoke detector 04.05.42.058 did not alarm when tested. 74 SOLAS (14) II-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 November 2018
Resolved 19 November 2018
Resolution: PSCO observed a successful test of the smoke detector.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.