MAURY USCG vessel records
← All vessels

MISS NEW YORK

MISS NEW YORK is a 1993 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2016, most recently in December 2025, along with 6 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 9 December 2025.

Built
1993
Last inspected
9 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 December 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ9717
389167
Flag
UNITED STATES
Maury page id
psix-389167

Documentation record

Registered dimensions (L × B × D)122.4 ft × 32.5 ft × 14.6 ft
Registered tonnagegross 99 / net 68
ITC dimensions (L × B × D)122.4 ft × 32.5 ft × 14.6 ft
ITC tonnagegross 534 / net 238
BuilderBLOUNT MARINE INDUSTRIES · WARREN, RI, UNITED STATES · built 1993
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLIBERTY ISLAND, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it238 - Convention (Subpart B), Net Ton
68 - Regulatory (Subpart C or D), Net Ton
534 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 26

9 December 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8279248
2 December 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8275790
11 June 2025 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8161835
10 December 2024 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8039047
19 November 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8036473
21 December 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7863377
28 September 2023 Welding Related Inspections Qualification Testing · Plan Review (Other than "T")
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7799689
7 March 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7606490
12 September 2022 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7557320
11 March 2022 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7404527
11 February 2022 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7394855
18 November 2021 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7353660
8 September 2021 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7307475
27 April 2021 MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7183519
18 March 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7055115
13 January 2020 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6888013
20 March 2019 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6645807
7 November 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6576294
18 October 2018 Administrative Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6564506
22 March 2018 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6376448
7 February 2018 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6351035
10 January 2018 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6335324
15 March 2017 MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6105422
9 March 2016 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6029566
8 March 2016 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5929954
25 February 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5821602

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 December 2025 Resolved
Fire extinguishing equipment installed on a vessel must be designed, constructed, installed, and maintained in a manner acceptable to the commandant. Sprinkler system in the battery room auto function was inop. Repair system prior to using lithium-ion batteries for vessel. 46CFR118.120(a)
Action required: 705 - Other - as specified
Resolved 21 January 2026
Resolution: Water spray system was repaired and tested in automatic and manual mode. Full coverage of battery space observed. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 December 2024 Resolved
Emergency CO2 shutdown for vsl gernerators are inoperable. Complete within 90 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 March 2025
Resolved 19 December 2024
Resolution: 19DEC2024: Boarded vessel afloat at Liberty Landing Service Marina in Jersey City, New Jersey, verified that the ladder in the battery space has been properly securedand witnessed satisfactory testing of the Co2 alarm & shutdown of the generators & ventil
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 December 2024 Resolved
Confirm version of ROSEPOINT Navigational system. Complete within 14 days.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2024
Resolved 17 December 2024
Resolution: Paper charts on board
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 10 December 2024 Resolved
Lower portion of ladder to battery space need to be secured.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2024
Resolved 19 December 2024
Resolution: 19DEC2024: Boarded vessel afloat at Liberty Landing Service Marina in Jersey City, New Jersey, verified that the ladder in the battery space has been properly securedand witnessed satisfactory testing of the Co2 alarm & shutdown of the generators& ventil
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 December 2024 Resolved
Boiler safety relief valve is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2025
Resolved 17 December 2024
Resolution: 17DEC2024: Witnessed satisfactory Boiler safety relief valve bench test.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 7 November 2018 Resolved
Vsl is broadcasting greater/smaller than expected vessel length and Vsl is broadcasting Draft > than Beam
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 March 2022

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.