Inspection history · 58
18 October 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7812098
13 July 2023
Re-Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7742292
24 April 2023
Re-Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7675071
18 January 2023
Re-Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7622970
26 October 2022
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7582685
14 July 2022
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7506545
6 July 2022
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7498508
3 May 2022
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7442909
21 April 2022
Deficiency Check · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7435579
26 January 2022
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7385782
30 September 2021
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7323749
25 August 2021
Deficiency Check · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7295955
14 July 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7255666
30 April 2021
Re-Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7186454
15 March 2021
Administrative Inspection · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7156223
25 February 2021
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7146161
20 January 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7127710
7 January 2021
MTSA Verification · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7121302
12 December 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7111006
23 November 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7102044
23 November 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7104481
12 November 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7094705
16 October 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7079743
8 October 2020
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7070366
23 September 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7070246
25 June 2020
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7023655
26 March 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7038330
9 January 2020
MTSA Verification · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6887313
15 November 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6856221
12 November 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6854610
8 October 2019
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6830584
5 September 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6805372
11 July 2019
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6744810
28 January 2019
Re-Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6615918
16 October 2018
COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6562396
6 August 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6502457
17 May 2018
Re-Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6422662
20 March 2018
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6377631
8 February 2018
Re-Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6422700
1 December 2017
Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6316165
7 November 2017
COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6302424
29 September 2017
In-Service Inspection · Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6278198
1 September 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6259943
17 August 2017
Administrative Inspection · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6243328
23 May 2017
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6153339
19 May 2017
Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6149965
28 March 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6113311
9 February 2017
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6086258
9 February 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6097532
26 January 2017
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6077976
30 November 2016
COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6049677
22 June 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5933813
20 June 2016
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5913249
19 May 2016
Re-Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5881109
14 April 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5853933
11 February 2016
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5813433
22 January 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5801978
6 January 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5792138
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 January 2023
Resolved
All engine designs installed shall be of marine type engines suitable for the intended service, designed and constructed in conformance with the requirements of this sub-chapter. Cylinder temperature sensors on the #1, #2, and #3 main engines are not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 January 2023
Resolved 2 February 2023
Resolution: Received and accepted pictures of corrected cylinder temperature sensors on #1, #2, and #3 MDE's.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 18 January 2023
Resolved
Gears, couplings, flywheels and all machinery capable of injuring personnel shall be provided with adequate covers or guards. Lagging/ heat-shields are missing on the #1 and #2 Main Engines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 January 2023
Resolved 2 February 2023
Resolution: Received and accepted pictures of Lagging/ heat-shields installed on the #1 and #2 Main Engines.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 January 2023
Resolved
Alternate groups of lights in an engine room, boiler-room, or auxiliary machinery space must be arranged so that the failure of one branch circuit does not leave an area without light. Each space used by passengers or crew must be fitted with lighting that provides for a safe habitable and working environment under normal conditions. (04) overhead light fixtures are not working in the Engine Room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 January 2023
Resolved 2 February 2023
Resolution: Received and accepted pictures of (04) overhead light fixtures working in the Engine Room.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 18 January 2023
Resolved
At the next dry-dock/internal structural exam remove all the benches on the main deck Brooklyn Side along the windows to gauge and determine the cause of the excessive visible corrosion, scaling and de-laminating of the deck covering. The structural decks a shall be constructed of steel or other equivalent metal construction of appropriate scantlings.
Action required: 705 - Other - as specified
Due 30 September 2023
Resolved 22 January 2024
Resolution: Vessel has surrendered the COI and is now inactive
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 April 2022
Resolved
Bulkheads or decks of the "A" class shall be composed of steel or equivalent metal construction. Deck penetration in NYE dugout was found unpacked. Deficiency rectified.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 April 2022
Resolved 21 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2022
Resolved
Electrical installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. Found broken outlet cover on a passenger bench in vicinity of the EDG. Keep power secured to outlet until cover is replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 April 2022
Resolution: Replaced receptacle
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 6 October 2021
Resolved
All bulkheads and decks shall be classed as A-60, A-30, A-15, A-0, B-15, B-0 or C, depending upon the type of space on each side of the bulkhead or above and below the deck. Found a hole in main deck broom closet bulkhead in way of ventilation stack. Make permanent repairs to the satisfaction of attending Coast Guard Marine Inspector. 46 CFR 72.05-10(c)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 October 2021
Resolution: Complete as required
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 October 2021
Resolved
All portable fire extinguishers and semi-portable fire extinguishing systems must be maintained in accordance with NFPA 10. Portable fire extinguishers annual servicing was last completed in February 2020. Outfit vessel with properly serviced portable fire extinguishers. 46 CFR 71.25-20(a)(1)
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 October 2021
Resolution: Spoke to company and issue ahs been resolved.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangements rescue boats
Issued 6 October 2021
Resolved
Each muster station and embarkation station must be adequately illuminated. Observed New York End port side and Staten Island End (port & Stbd) embarkation lighting not operational. Vessel is restricted to day time operations until properly outfitted with operational embarkation lighting. 46 CFR 199.110(c)
Action required: 705 - Other - as specified
Resolved 27 October 2021
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 October 2021
Resolved
Electric installations on vessels must ensure maintenance of system integrity through compliance with the applicable system requirements. Found emergency ventilation stop buttons in New York and Staten Island pilot houses wedged, not at designed. Outfit vessel with properly functioning emergency ventilation stops as designed prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 October 2021
Resolved
Each panel board must have a circuit directory. Found panelboards ELI-1 and ELI-7 with no circuit directory cards. Outfit panelboards with circuit directory cards. 46 CFR 111.40-11(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2021
Resolved 27 October 2021
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 6 October 2021
Resolved
All valves and closing appliances for damage control purposes in case of emergency shall be conspicuously marked identifying the control and direction of operations. Clearly mark open/closed positions of fire dampers on bridge deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2021
Resolved 27 October 2021
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 6 October 2021
Resolved
All bulkheads and decks shall be classed as A-60, A-30, A-15, A-0, B-15, B-0 or C, depending upon the type of space on each side of the bulkhead or above and below the deck. Descale and UT main deck, under forward seating on the Staten Island side.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2021
Resolved 27 October 2021
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 6 October 2021
Resolved
All bulkheads and decks shall be classed as A-60, A-30, A-15, A-0, B-15, B-0 or C, depending upon the type of space on each side of the bulkhead or above and below the deck. Found hole in bulkhead, New York end, starboard side in way of rescue boat stowage location. Provide repair proposal for permanent repairs. 46 CFR 72.05-10(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2021
Resolved 27 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 October 2018
Resolved
JK01) Vessel's pressure vessel (#1-#4) are required to have proper marking and stamping. All name plates have been removed. Inspectors are unable to determine the proper MAWP to ensure the correct relief valve is installed on the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2018
Resolved 11 October 2019
Resolution: data plate was installed
Engineering › Sea-water System (primary cooling) › Valve
Issued 20 March 2018
Resolved
Replace affected valve.
Action required: 705 - Other - as specified
Due 4 April 2018
Resolved 27 March 2018
Engineering › Thrusters › Hose
Issued 1 December 2017
Resolved
Hydraulic hose parted that connected the reservoir to the rotor of the stern unit.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 1 December 2017
Resolution: Repair Complete, visual and sea trial test completed. 835 rescinded. VSL authorized back in service.
Electrical › Electric Generation Source (emergency) › Circuit Breaker
Issued 29 September 2017
Resolved
Vessel experienced failure of breaker to close automatically on EDG.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2017
Resolution: Breaker was replaced and a test of EDG was performed to the satisfaction of the attending USCG MI.
Electrical › Electrical Distribution System (service) › Switch
Issued 17 August 2017
Resolved
Reverse power relay switch is not working when generators are parallel between SSDG2 - SSDG1. SSDG1 will not pick up the load. Vessel must repair or replace this switch and prove proper operation.46CFR111.12-11(f)
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 21 August 2017
Resolution: 21AUG17: Received email with pictures indicating a satisfactory reverse trip of the #2SSDG, please see attached document for further information.
Lifesaving › Rescue Boat › Hull (rigid)
Issued 26 January 2017
Resolved
Damage from impact created a fracture in the fiberglass layup.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 February 2017
Resolved 9 February 2017
Resolution: Rescue boat was replaced with type approved replacement in kind.
Stability › Water on Deck › General
Issued 30 November 2016
Resolved
Deck drain on 01 deck is rusted and needs to be replaced.
Action required: 705 - Other - as specified
Resolved 7 December 2016
Resolution: Replaced deck drain and associated piping.