Records from 2016 to 2026. Most recent: inspection, 10 April 2026.
Inspection history · 20
10 April 2026
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8345996
11 March 2025
Internal Structural Exam · Annual Inspection · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8091296
3 September 2024
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7999106
15 May 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7912713
6 April 2023
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7663489
29 March 2023
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7658605
24 January 2023
Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7665871
2 June 2022
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7452017
2 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7404493
1 July 2021
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7241141
5 April 2021
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7169041
24 July 2020
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7025415
25 June 2020
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6986756
27 March 2020
Drydock Extension · Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6932253
23 April 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6644365
21 May 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6382191
23 March 2018
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6358932
7 March 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6100135
16 August 2016
In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5983762
16 March 2016
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5843450
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 April 2023
Resolved
Vessel has undergone a weight change due to an engine repower. Resulting in reducing total persons onboard by 1. Vessel may not carry more than 14 total POB.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 April 2023
Resolved 26 June 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 2 June 2022
Resolved
E steering requires a quick release clip in order to use. Vessel did not have one installed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 14 June 2022
Resolution: Installed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 June 2022
Resolved
Emergency fuel shut off not labelled.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 14 June 2022
Resolution: Labelled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 June 2022
Resolved
PFD stowage not marked.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2022
Resolved 14 June 2022
Resolution: Marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 June 2022
Resolved
Waterlight batteries had regular AAs not lithium AAs as required by manufacturer. Restricted to daylight operations only.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 July 2022
Resolved 14 June 2022
Resolution: Replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 June 2022
Resolved
Place a PFD donning placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2022
Resolved 14 June 2022
Resolution: Posted.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 2 June 2022
Resolved
Vessel was not logging drills.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2022
Resolved 14 June 2022
Resolution: Logged.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 June 2022
Resolved
Waterlight is required a 3-6' line w/a quick release clip attached around the body of the life ring.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 14 June 2022
Resolution: Fixed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 July 2021
Resolved
Provide documents and comply with regulations listed in the Special Considerations for Vessels Operating as Yacht Launches. Provide plans and proof of company policies and procedures in order to comply with regulations listed.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 5 July 2021
Resolution: Corrected IAW SLIS Special Consideration. See Special not added.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 July 2021
Resolved
Provide via email, copies of fire fighting and life saving maintenance records, proving maintenance is being conducted.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 5 July 2021
Resolution: Documents provided after re-attending
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 July 2021
Resolved
Provide, via email Consortium MIS report for 2020.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 5 July 2021
Resolution: MIS Submitted via email
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 April 2021
Resolved
Complete credit dry dock and internal structural exam IAW 46 CFR 176.600 prior to operating.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2021
Resolved 6 April 2021
Resolution: Conducted DD/ISE
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 25 June 2020
Resolved
Fixed fire fighting system does not shut down the MDE as designed.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2020
Resolved 24 July 2020
Resolution: Tested pre-engineered fixed gas system with new engine install.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2020
Resolved
Submit plans for newly installed MDE for plan review and approval
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2020
Resolved 24 July 2020
Resolution: RCVD plans and specs for new MDE install. Added information to this vessel's notes.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 23 April 2019
Resolved
Vessel is certificated to carry 16 persons where the managing operator only had a OUPV licensed mariner. Restricted use to 6 passengers only and adherence to all other requirements listed on the issued COI.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2019
Resolved 10 July 2019
Resolution: Members rcvd proper licensing
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 April 2019
Resolved
Records of passenger counts required to be kept and maintained.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2019
Resolved 3 May 2019
Resolution: Procedures in place to maintain passenger couns IAW SLIS considerations for yacht launches
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2019
Resolved
PFD stowage location not labled with correct number of PFDs stowed
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 23 April 2019
Resolved 23 April 2019
Resolution: PFD stowage relabled to reflect correct number of PFDs in the stowage location
01 - Certificates & Documentation › 011 - Ships Certificates › Maritime Labour Certificate
Issued 23 April 2019
Resolved
DAPI - provide proof of EAP program for employees
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2019
Resolved 21 May 2019
Resolution: Company representative provided proof of program through Consortium enrollment and provided proof of 60 minute training
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 April 2019
Resolved
Crew training record not kept and maintained. Provide crew training program and records
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2019
Resolved 21 May 2019
Resolution: Company established procedures for crew training and records.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 April 2019
Resolved
Type IV ring buoy lableing was worn from exposure. Re-stencil type IV IAW CFR
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 April 2019
Resolved 23 April 2019
Resolution: Life ring restenciled. All SAT
08 - Alarms › N/A - No Subsystem › General alarm
Issued 23 April 2019
Resolved
Vessel high water alarm was inoperable in the machinery space
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2019
Resolved 21 May 2019
Resolution: High water alarm light and speaker for audible was replaced and tested; All SAT
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 21 May 2018
Resolved
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2018
Resolved 21 May 2018
Resolution: O/O repaired system on the spot.