Records from 2016 to 2026. Most recent: inspection, 10 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 19
10 April 2026
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8346003
11 March 2025
Administrative Inspection · Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8091529
3 September 2024
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7999106
15 May 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7912711
6 April 2023
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7663491
29 March 2023
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7658612
24 January 2023
Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7665820
2 June 2022
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7452022
16 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7412815
3 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7405153
1 July 2021
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7241153
5 April 2021
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7169059
26 June 2020
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7064225
27 March 2020
Drydock Extension · Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6932259
23 April 2019
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6644403
21 May 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6382196
23 March 2018
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6358990
7 March 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6100136
16 March 2016
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5843470
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 April 2023
Resolved
Vessel has undergone a weight change due to an engine repower. Resulting in reducing total persons onboard by 1. Vessel may not carry more than 14 total POB.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 April 2023
Resolved 26 June 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 2 June 2022
Resolved
E steering requires a quick release clip to be operational.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2022
Resolved 14 June 2022
Resolution: Installed.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 2 June 2022
Resolved
Emergency Fuel shut off not labelled.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2022
Resolved 14 June 2022
Resolution: Labelled
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 June 2022
Resolved
PFD storage not labelled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2022
Resolved 14 June 2022
Resolution: Labelled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 June 2022
Resolved
Waterlight had incorrect AAs installed. Restricted to daytime ops.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 July 2022
Resolved 14 June 2022
Resolution: Installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 June 2022
Resolved
Waterlight is required to have a 3-6' line attached.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2022
Resolved 14 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 June 2022
Resolved
PFD donning placard not posted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2022
Resolved 14 June 2022
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 2 June 2022
Resolved
Drills not logged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2022
Resolved 14 June 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 June 2022
Resolved
Repair/replace warning audible alarm on fireboy override system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2022
Resolved 14 June 2022
Resolution: Fixed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 July 2021
Resolved
Provide documents and comply with regulations listed in the Special Considerations for Vessels Operating as Yacht Launches. Provide plans and proof of company policies and procedures in order to comply with regulations listed.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 5 July 2021
Resolution: Corrected IAW SLIS Special Consideration. See Special not added.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 July 2021
Resolved
Provide via email, copies of fire fighting and life saving maintenance records, proving maintenance is being conducted.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 5 July 2021
Resolution: Documents provided after re-attending
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 July 2021
Resolved
Provide, via email Consortium MIS report for 2020.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 July 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 April 2021
Resolved
Complete credit dry dock and internal structural exam IAW 46 CFR 176.600 prior to operating.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2021
Resolved 6 April 2021
Resolution: Completed credit DD/ISE
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 June 2020
Resolved
Operator had not serviced pre-engineered fire extinguishing system as required. 46 CFR 176.810
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 June 2020
Resolution: Operator replaced pre-engineered system in kind during annual inpsection
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 April 2019
Resolved
Passenger counts required
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2019
Resolved 3 May 2019
Resolution: Procedures in place to maintain passenger couns IAW SLIS considerations for yacht launches
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2019
Resolved
PFD stowage location not labled with correct number of PFDs stowed
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 23 April 2019
Resolved 23 April 2019
Resolution: PFD stowage relabled to reflect correct number of PFDs in the stowage location
01 - Certificates & Documentation › 011 - Ships Certificates › Maritime Labour Certificate
Issued 23 April 2019
Resolved
DAPI - provide proof of EAP program for employees
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2019
Resolved 21 May 2019
Resolution: Company representative provided proof of program through Consortium enrollment and provided proof of 60 minute training
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 23 April 2019
Resolved
Vessel certificated for 16 passengerswhere the company only had a cretentialed OUPV. Restricted use to 6 passengers only.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 7 May 2019
Resolved 10 July 2019
Resolution: Rcvd proper licensing
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 April 2019
Resolved
Crew training record not kept and maintained. Provide crew training program and records
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2019
Resolved 21 May 2019
Resolution: Company established procedures for crew training and records.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 April 2019
Resolved
Type IV ring buoy lableing was worn from exposure. Re-stencil type IV IAW CFR
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 April 2019
Resolved 23 April 2019
Resolution: Life ring restenciled. All SAT