Records from 2016 to 2026. Most recent: inspection, 15 April 2026.
Inspection history · 47
15 April 2026
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8351171
23 March 2026
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8330178
20 March 2026
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8329097
28 November 2025
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8274788
17 November 2025
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8269484
2 November 2025
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8262139
28 October 2025
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8262845
10 June 2025
ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8156202
13 August 2024
Periodic Inspection · ACP Periodic Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7980082
11 July 2024
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7956527
2 May 2024
Administrative Inspection · Liferaft Servicing
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7905086
31 October 2023
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7816810
16 June 2023
Deficiency Check · Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7729689
7 May 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7683311
25 April 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7676511
14 February 2023
Liferaft Servicing
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7636863
9 May 2022
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7446545
27 January 2022
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7386970
12 October 2021
In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7330686
4 October 2021
Damage Survey · Administrative Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7325849
2 September 2021
Administrative Inspection · Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7303110
4 August 2021
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7276884
3 August 2021
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7332109
6 July 2021
ACP COI Oversight · Re-Inspection · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7185088
25 March 2021
Administrative Inspection · Permit to Proceed
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7171442
21 December 2020
Type not recorded
No type recorded · Activities Europe · Activity 7115460
17 August 2020
Administrative Inspection
Administrative · Activities Europe · Activity 7035381
7 July 2020
Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7014737
20 June 2020
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6983229
11 June 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6974339
15 May 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6954005
13 May 2020
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6966246
20 April 2020
ACP Annual Oversight · Annual Inspection · ACP Drydock Oversight
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6923330
5 December 2019
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6868301
9 October 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6832252
19 September 2019
Annual Inspection · ACP Annual Oversight · ACP Drydock Oversight
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6674603
22 May 2019
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6690988
1 April 2019
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6653932
22 January 2019
In-Service Inspection · ISM Oversight · ISM SMC Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6613076
27 October 2018
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6570325
1 October 2018
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6555761
22 May 2018
Deficiency Check · ACP Annual Oversight · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6419989
29 January 2018
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6345306
6 March 2017
ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6096283
31 August 2016
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5988939
31 August 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6054213
2 February 2016
COI Inspection · ACP COI Oversight
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5811961
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 June 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the
present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Make repairs to the ships boilers to meet company minimum standards for underway operations as per internal SMS policy.SOLAS/ 1-11
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2025
Resolved 27 July 2025
Resolution: Recieved confirmaiton from ABS Senior Surveyor Jung-Hoon Kim that this item was rectified to his satisfaction during an attendance.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 10 June 2025
Resolved
The Administration shall be satisfied that adequate arrangements are in place to ensure that the
performance of the equipment required by this chapter is maintained. Attending MI's observed several alarms on both radars that have compromised reliability.SOLAS/V-15.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2025
Resolution: Recieved confirmaiton from ABS Senior Surveyor Jung-Hoon Kim that this item was rectified to his satisfaction during an attendance.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 10 June 2025
Resolved
Nautical charts and nautical publications, such as sailing directions, lists of lights, notices to mariners for the intended voyage shall be adequate and up to date. The limitations of the ships bandwidth is preventing underway update of ECDIS charts. On board charts are updated to 23 July 2025, however should the
ship operate outside of it's downloaded content there
is no capacity to retrieve updated charts updates.SOLAS V/27
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 August 2025
Resolution: ABS Finding 2317: vessel's network bandwidth increased and allowed charts to be updated for operating regions.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 June 2025
Resolved
Emergency lighting shall be provided at every muster and embarkation, in the machinery space and main generating stations, accommodation alleyways, stairways and exits. Attending MI's noted battle lanterns ship-wide failed to operate when tested or were flashing due to low battery.SOLAS II-1/43.2.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2025
Resolution: Recieved confirmaiton from ABS Senior Surveyor Jung-Hoon Kim that this item was rectified to his satisfaction during an attendance.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 10 June 2025
Resolved
The company should establish procedures, plans and instructions for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. The use of air-pods during the fire drill and abandon ship drills interferes with communication, situational awareness and response readiness.ISM Code 6.3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2025
Resolution: Recieved confirmaiton from ABS Senior Surveyor Jung-Hoon Kim that this item was rectified to his satisfaction during an attendance.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 10 June 2025
Resolved
Before the ships leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Attending MI noted that the connection of the mechanical linkage for steering to the tiller arm on all four lifeboats is non standard, and in 3 out of 4 instances a cotter pin was being used as a load bearing connection for the steering
Additionally the port rescue boat had severe wastage of the buoyant oars, water intrusion into the TPA's, spare flashlight batteries and the forward hatch latching mechanism is not being utilized allowing for continual water intrusion into the hull. The retro reflective tape is badly faded on top and in need of replacement.SOLAS III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2025
Resolution: Recieved confirmaiton from ABS Senior Surveyor Jung-Hoon Kim that this item was rectified to his satisfaction during an attendance.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 10 June 2025
Resolved
An immersion suit, complying with the requirements of section 2.3 of the Code or an anti-exposure suit
complying with section 2.4 of the Code, of an appropriate size, shall be provided for every person. During the immersion suit donning it was observed that three crew members didn't have appropriate sized suits that match their body size.SOLAS III/7.3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 November 2025
Resolution: Recieved confirmaiton from ABS Senior Surveyor Jung-Hoon Kim that this item was rectified to his satisfaction during an attendance.
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 10 June 2025
Resolved
For a period of 18 hours intermittent operation of the daylight signaling lamp, the ship's whistle, the manually operated call points and all internal signals that are required in an emergency unless such services have an independent supply of power. Signal lamps on the bridge were functional under battery power however there is not indication of battery life, routine charging or procedures to maintain this equipment.SOLAS II-1/43
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2025
Resolution: Recieved confirmaiton from ABS Senior Surveyor Jung-Hoon Kim that this item was rectified to his satisfaction during an attendance.
04 - Emergency Systems › N/A - No Subsystem › Emergency towing arrangements and procedures
Issued 10 June 2025
Resolved
Emergency towing arrangements on tankers the arrangements shall, at all times, be capable of rapid deployment in the absence of main power
on the ship to be towed and easy connection to the towing ship. At least one of the emergency
towing arrangements shall be per-rigged ready for rapid deployment. Attending MI observed that the water activated light in the towing arrangement located on the stern mooring decks is inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 27 July 2025
Resolution: Recieved confirmaiton from ABS Senior Surveyor Jung-Hoon Kim that a condition of class has been issued.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 June 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the
present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Extensive wastage was noted around the ventilation supply/exhausts located in the forward rope locker and cargo gas cylinder storage rooms.SOLAS I-11
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2025
Resolution: Recieved confirmaiton from ABS Senior Surveyor Jung-Hoon Kim that a condition of class has been issued.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 10 June 2025
Resolved
Each tank ships must have at least two emergency shutdown stations. Each emergency shutdown station must have the controls necessary to stop all cargo pumps on the tank ship. Cargo Pump emergency trip was tested and would not reset during the inspection halting further testing. Restore operation of all emergency stops and retest all with the RO or USCG in attendance prior cargo
operations.46 CFR 153.296
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2025
Resolution: Recieved confirmaiton from ABS Senior Surveyor Jung-Hoon Kim that this item was rectified to his satisfaction during an attendance.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 10 June 2025
Resolved
Provisions shall be made to guard against liquid rising in the venting system to a height which would exceed
the design head of cargo tanks. This shall be accomplished by high-level alarms or overflow control systems. The high level and overfill visual alarm lights located on the tank deck are missing the required posted placards.SOLAS II-2/11.6.3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2025
Resolution: Recieved confirmaiton from ABS Senior Surveyor Jung-Hoon Kim that this item was rectified to his satisfaction during an attendance.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 10 June 2025
Resolved
The life jackets and immersion suits carried for persons on watch should be stowed on the bridge, in the engine control room and at any other manned watch station; Immersion suits are missing from the watch station in the engine control room. A suitable location that is properly labeled needs to be identified and suits supplied.SOLAS III / 7.2.4
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2025
Resolution: Recieved confirmaiton from ABS Senior Surveyor Jung-Hoon Kim that this item was rectified to his satisfaction during an attendance.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 August 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Marine Inspector found fuel oil leaking through gaskets on both M/E and all SSDGs. After expanding the inspection to determine the cause, objective evidence was discovered that the affected engines were being operated beyond the OEM overhaul limits. Vessel to maintain at least one wiper/engine utility crew member in engine room any time an engine is running to manage all leaking fuel until repairs are made to arrest all fuel leaks to the satisfaction of ABS during drydock in November 2024.
74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2024
Resolved 13 September 2024
Resolution: Accepted by ABS
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 15 August 2024
Resolved
Ships of 500 gross tonnage and upwards shall be provided with at least one international shore connection, complying with the provisions of paragraph 3. Facilities shall be available enabling such a connection to be used on either side of the ship. Marine Inspector found that port side shore connection valve was seized closed by valve stem and connection cover. Repairs to valve and cover. Make international shore connection and valve operation available for inspection to satisfaction of the attending ABS surveyor prior to departure.
74 SOLAS (97) II-2/19.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2024
Resolution: Accepted as finding 2214.0 and repaired with oversight of USCG and ABS.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 August 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Marine Inspector found fuel oil leaking through gaskets on both M/E and all SSDGs. After expanding the inspection to determine the cause, objective evidence was discovered that the affected engines were being operated beyond the OEM overhaul limits. Develop a risk mitigation plan and repair plan for approval by the OCMI prior to departure from the Port of Singapore.
74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2024
Resolution: Plans accepted by CID.
01 - Certificates & Documentation › 011 - Ships Certificates › International Anti-fouling-System Certificate
Issued 15 August 2024
Resolved
When the Administration, a nominated surveyor, or a recognized organization
determines that the ship's anti-fouling system does not conform either to the
particulars of a Certificate required under regulation 2 or 3, or to the requirements
of this Convention, such Administration, surveyor or organization shall immediately ensure that corrective action is taken to bring the ship into compliance. Marine Inspector found that vessel had a significant amount of hard marine growth on the hull. This was determined from viewing dockside, from the UWILD inspection report performed at last port in Thailand, and from the hard growth on the anchor chain. Provide plan for hull cleaning and subsequent ABS attendance that will include removal of all aquatic organisms from hull, rudder, prop, sea chest strainers. Sea chest strainers shall be removed and sea chests shall be cleaned as part of the proposal. Any port State affected by the removal process shall be notified prior to removal. This proposal will have to be approved by OCMI prior to departure from Port of Singapore.
IAFS 2001 Annex 4, Reg. 1(4)(c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2024
Resolution: Hull cleaning plan accepted by CID.
01 - Certificates & Documentation › 011 - Ships Certificates › International Anti-fouling-System Certificate
Issued 15 August 2024
Resolved
In the situation described in subparagraph (c), if the ship is in the port of another Party, the appropriate authorities of the port State shall be notified forthwith. Marine Inspector found significant non-conformity with SOVC for Anti-Fouling System Certificate. Notify Singapore Port State Control of deficiency 03 and plans to be approved by U.S Flag State (OCMI) for regaining compliance with the requirements of the Convention prior to departure from Port of Singapore.
IAFS 2001 Annex 4, Reg 1(4)(d)
Update 17AUG2024: CID will follow up with Singapre PSC to ensure notification. Extending to 30 days.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2024
Resolved 5 September 2024
Resolution: Vessel has left Singapore.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 August 2024
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that: Inspections are held at appropriate intervals; any non-conformity is reported, with its probable cause, if known; and appropriate action is taken. Marine Inspector found that both M/E and all SSDG are leaking fuel oil. After expanding inspection, objective evidence was found that all affected engines had gone beyond their OEM overhaul dates. This has resulted in engineering department having to wipe up leaking fuel on a continual basis and a hazardous operating environment. Perform an internal audit to determine root cause of exceeding maintenance and inspection requirements, to determine whether the non-conformity was properly reported, and to determine whether the appropriate action was taken.
74 SOLAS (20) IX/3.1
ISM 2018 A/10.1 and 10.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2024
Resolved 17 August 2024
Resolution: Accepted as finding 2215.0 by ABS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 August 2024
Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. However, hold-back arrangements fitted with remote release devices of the fail-safe type may be utilized. Aft roller door to helicopter landing deck: Door fusible link failed the inspection during annual certification with GFS. Inspector verified manual and electronic closing mechanism worked at time of inspection. Make repairs to fusible link (self-closing) arrangements and have inspected to satisfaction of ABS.
74 SOLAS (97) II-2/47.2
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 December 2024
Resolved 2 December 2024
Resolution: Accepted as finding #2233.0
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 August 2024
Resolved
No equipment shall be installed in…paint lockers…unless the Administration is satisfied that such equipment is: appropriately certified for safe usage in the dusts, vapours or gases likely to be encountered. Forward paint locker was found with a non-explosion proof fan permanently installed. Replace fan or remove to satisfaction of ABS.
74 SOLAS (04) II-1/45.10.4
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 December 2024
Resolved 2 December 2024
Resolution: Accepted as finding #2234.0
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 15 August 2024
Resolved
The company should establish a safety…policy which describes how the objectives given in paragraph 1.2 will be achieved. Vessel SMS does not contain instructions for reporting incidents of sexual assault or harassment directly to Coast Guard National Command Center at [phone withheld] or via email at [email withheld], (and if in immediate danger to call 9-1-1) as required by 46 U.S.C. 10104. Conduct an internal audit and make necessary changes to vessel SMS to satisfaction or ABS.
74 SOLAS (20) IX 3.1
ISM Part A 2.1
CVC-WI-004(3) D.1.b.1
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 28 December 2024
Resolved 2 December 2024
Resolution: Accepted as finding #2235.0
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 15 August 2024
Resolved
Each crew berthing area shall be equipped with information regarding procedures and resources to report crimes, including sexual assault and sexual harassment, including information on the telephone number, website address, and email address for reporting allegations of sexual assault and sexual harassment to the Coast Guard. Vessel does not have posters with information/option to report sexual harassment/assault to USCG. Provide posters that provide information for victims to report incidents to USCG by means as stated in deficiency 09. These posters shall be in each berthing area and each crew washing place to the satisfaction of ABS.
46 U.S.C. 11101(B)(i)
USCG CVC Policy Letter 23-04
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2024
Resolved 2 December 2024
Resolution: Accepted as finding #2236.0
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 18 June 2023
Resolved
A person may not employ or engage an individual in a position to hold an MMC unless that individual maintains a current medical certificate. Per MSC and USCG MOA, the national endorsement expiration date will be used to determine the validity of a medical certificate for a CIVMAR. During review of crew's medical certificates, it was discovered that the 2/AE's, national endorsement expiration date is 18JUN2023. As a condition of employment, medical certificate must be renewed. Provide proof of current medical certificate to the satisfaction of the attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 August 2023
Resolution: Email received from vsl master with proof that mariner has one year left on medical certificate; verified and cleared to the satisfaction of the attending USCG MI.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 June 2023
Resolved
Lifeboats and rescue boats retro-reflective materials should be fitted on top of the gunwale as well as on the outside of the boat as near the gunwale as possible. Replace weathered SOLAS reflective tape on port FRB with new.
Action required: 10 - Deficiency Rectified
Resolved 22 June 2023
Resolution: New approved reflective tape replaced to the satisfaction of the attending MI.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 18 June 2023
Resolved
The general emergency alarm system shall be audible throughout all the accommodation and normal crew working spaces. Repair and prove operation of the following general alarms: 03 passage, 04 passage, cargo main deck next to 9P CC, port flight deck house, and inside motor room no. 1 stairwell.
Action required: 10 - Deficiency Rectified
Resolved 22 June 2023
Resolution: Repaired and tested to the satisfaction of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 June 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons. Repair leak to STBD sea chest in cargo pump room.
Action required: 10 - Deficiency Rectified
Resolved 20 June 2023
Resolution: Packing gland replaced with new and video sent from vessel's C/E showing valve exercised in close/open position with no leaks observed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 June 2023
Resolved
The purpose of this chapter is to require the fullest practicable degree of fire protection, fire detection and fire extinction in ships. The following basic principles underlie the regulations of this chapter and are embodied in the regulations as appropriate…containment and extinction of any fire in the space of origin and minimization of possibility of ignition of flammable cargo vapour. Replace missing fire stop in at the following locations: cable penetration in space labeled: MJD 03-06-02 To ELEC EQPT RM 03-60-0 Station 4 DK GR LKR, Station 6 DK GR LKR, OAW-TD 01-21-0 (above), Winch Control Room 1-58-0 (inside), High Press Comp Rm 1-40-0 (inside), and above WTD 1-20-1.
Action required: 10 - Deficiency Rectified
Resolved 22 June 2023
Resolution: Backfilled with new fire stop and inspected to the satisfaction of the attending USCG MI.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 16 June 2023
Resolved
Cargo ships where the horizontal distance from the extreme end of the stem or stern of the ship to the nearest end of the closest survival craft is more than 100 m shall carry, in addition to the liferafts required by paragraphs 1.1.2 and 1.2.2, a liferaft stowed as far forward or aft, or one as far forward and another as far aft, as is reasonable and practicable. Such liferaft or liferafts may be securely fastened so as to permit manual release and need not be of the type which can be launched from an approved launching device. Replace missing required 25 x person life raft per SOLAS to the satisfaction of the attending ABS surveyor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2023
Resolved 3 July 2023
Resolution: See Class Preliminary Report attached to Documents.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 16 June 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Resolved 29 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 11 June 2020
Resolved
A lifeboat launching appliance shall be capable of recovering the lifeboat with its crew IAW SOLAS 1997 Cons. Ed. Ch. III Reg 48.1.10. The winch brakes of a launching appliance shall be of sufficient strength to withstand a static test with a proof load of not less than 1.5 times the maximum working load and a dynamic test with a proof load of not less than 1.1 times the maximum working load at maximum lowering speed. On June 11, 2020 the master reported that the #2 lifeboat was lowered to the water for drill purposes and the crew was unable to recover the lifeboat using the launching/recovery appliance due to the winch clutch malfunctioning. It was also reported by the master that the #2 davit brake is no longer operable. Later, the master reported that YUKON was able to lift the #2 lifeboat onboard and cradle it by manually lightly lifting the hand brake. The hand crank however would not move the lifeboat. Vessel plans to mitigate the inability to retrieve the lifeboat by utilizing the 6 currently installed life-rafts on the port side. Vessel shall not carry over 94 persons on this voyage until #2 lifeboat davit brake is repaired and static tested and dynamic tested in accordance with regulations. Vessel shall conduct additional safety briefs for crew and avoid unnecessary activity IVO #2 lifeboat. No parts/technician was available in current port; vessel authorized to proceed to next port for repairs.
Action required: 15 - Rectify deficiencies by next port
Due 15 June 2020
Resolved 12 June 2020
Resolution: Surveyor reccomended that the #2 lifeboat davit be repaired and re-inspected by OEM, to the satisfaction of the attending surveyor. Operational testing to include static and dynamic load testing.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 5 December 2019
Resolved
Make permanent repairs to crack discovered on potable water tank.
Action required: 705 - Other - as specified
Resolved 9 December 2019
Resolution: Accepted by RO.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 7 March 2019
Resolved
Vessel shall carry one or more lifeboats of such aggregate capacity on each side of the ship as will accommodate the total number of persons on board. Vessel has 02- 69 person capacity lifeboats on each side of vessel. ABS identified Lifeboat #3 winch foundation with 4" crack on weld at forward leading edge during recent UT survey (see OSR/OSD 1754/1755). 10% overload dynamic weight test shall be performed prior to vessel sailing with more than 69 persons on board.
Action required: 705 - Other - as specified
Resolved 11 April 2019
Resolution: Repairs completed/witnessed by ABS Surveyor. OSD 1755
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 29 January 2019
Resolved
The above items, as well as items 1660, 1674-1680, 1697, 1654-1657, 1659 & 1652, some of which were reported to the company as far back as Aug 2018 were not reported to ABS until annual surveys began in Jan 2019. Corroded cargo vent pipes and holed bulkheads/ventilation demonstrate a lack of preventative maintenance. Constant use of belzona/fiberglass for temporary repairs and company's failure to provide assistance for permanent repairs on critical systems demonstrates a failure of the vessel's Safety Management System. Even though a flag state detention is not imposed, an external SMS audit is required in the presence of a CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2019
Resolved 8 February 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 January 2019
Resolved
The following outstanding class items shall be permanently repaired:
1653 JP-5 Cargo Pump #3 fracture on recirculation pipe. 1656 E-Fire Pump corroded recirculation pipe at sea chest below sea valve. 1661 ERC unauthorized bulkhead penetrations from portable A/C units. 1663 Steering Gear - Stbd motor intermittent false phase fail alarm. 1664 Main Switchboard 1SB - circuit breakers for PTO #2 & SSDG #4 - not functioning as designed making systems unreliable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2019
Resolved 8 February 2019
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 January 2019
Resolved
The following additional items found on 01 Deck level:
01-42-3 Significantly corroded cargo tank air pipe
01-35-2 Containment holed
02-26-2 Air pipe missing 02 bolts for flame screen
01-26-2 Air pipe missing 02 bolts for flame screen
01-54-1 Air pipe DFM station 8 rail holed
01-110-1 FO containment on flight deck holed
WTH 07-103-1 Watertight hatch with significantly corroded lip (deck 06)
WTD 07-76-1 Door at bridge found with missing attachment bolts and belzona at bottom (excessive corrosion?)
Unlabeled 10C JP5 air pipe significantly corroded
01-96-2 Significantly corroded cargo tank air pipe
01-65-2/01-66-2/01-68-2/01-88-2 Significantly corroded FO tank air pipes
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2019
Resolved 8 February 2019
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 27 October 2018
Resolved
Repair or replace S-band radar.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2018
Resolved 5 November 2018
Resolution: Cleared by ABS.