WEB 233 is a 2001 tank barge. The Coast Guard has recorded 35 inspections since 2001, most recently in February 2026, along with 3 deficiencies and 5 casualty investigations between 2005 and 2023.

Records from 2001 to 2026. Most recent: inspection, 5 February 2026.

Built
2001
Last inspected
5 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-39234

Inspections, by type

…with no type recorded10
Years with a record 20 calendar years (2001–2026)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2001
Hull materialSteel
PropulsionNone
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 November 2025 · expires 30 November 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Net Ton
1754 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 12

Inspection history · 35

5 February 2026 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8307126
7 August 2025 Examination of Repairs · Cargo Tank Internal · COI Inspection · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8204454
23 March 2023 Administrative Inspection · Examination of Repairs · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7655506
20 March 2023 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7659281
19 March 2023 Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7653358
8 June 2020 Internal Structural Exam · MTSA Verification · COI Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6981015
5 September 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6778062
9 August 2018 Annual Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6502912
11 September 2017 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6261998
28 December 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6063289
3 August 2016 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5959899
13 May 2015 Cargo Tank Internal · Administrative Inspection · MTSA Verification · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5126269
9 January 2015 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5048679
19 May 2014 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4860131
3 January 2014 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4777028
2 January 2014 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4951269
22 December 2011 Hull Examination · COI Inspection · Internal Structural Exam · Examination of Repairs · Cargo Tank Internal · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4212761
14 December 2011 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4208185
24 March 2010 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3702443
25 February 2009 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3423894
10 March 2008 Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3158869
8 January 2007 Administrative Inspection · MTSA Verification · Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2850028
23 October 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2810106
29 November 2005 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2542434
1 November 2005 Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2526926
6 August 2005 Type not recorded
No type recorded · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2475397
14 February 2005 Periodic Inspection · MTSA Verification
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2292279
24 November 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1954080
17 October 2003 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1930822
7 October 2003 Type not recorded
No type recorded · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1922225
11 December 2002 Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1717576
12 May 2002 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1627770
29 March 2002 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1598956
14 December 2001 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1474703
3 December 2001 Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1463719

Deficiency record · 3

Construction/Loadline › Hull › Hull Plating
Issued 14 December 2011 Resolved
Vessel needs complete Hull exam and ISE
Action required: 705 - Other - as specified
Due 23 December 2011
Resolved 23 December 2011
Resolution: ISE completed 22Dec11.
Construction/Loadline › Hull › Hull Plating
Issued 14 December 2011 Resolved
Complete Hull Exam.
Action required: 705 - Other - as specified
Due 3 January 2012
Resolved 21 February 2012
Resolution: Attended vessel with the vessel rep to conduct a credit drydock inspection. Examined all hull plating, knuckles, and gunwales, noting no significant damage or wastage.
Electrical › Lighting (service) › Grounding Conductor
Issued 17 October 2003 Resolved
Provide marine intrinsically safe electrical source for swing light (white LT on bow). LEGACY COMPONENT DESC: Outlet Box
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 November 2003
Resolved 8 January 2007

Casualty record · 5

6 August 2005Routine · role: Involved in a Marine Casualty · activity 2475397
23 October 2006Routine · role: Involved in a Marine Casualty · activity 2810106
7 March 2011Routine · role: Involved in a Marine Casualty · activity 3979205
28 December 2016Routine · role: Involved in a Marine Investigation (non-casualty) · activity 6063289
20 March 2023Routine · role: Involved in a Marine Casualty · activity 7659281
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.