NA HOKU II

NA HOKU II is a 1989 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 1994, most recently in February 2026, along with 226 deficiencies — 1 with no resolution recorded —, 4 operational controls and 2 casualty investigations between 2006 and 2020.

Records from 1994 to 2026. Most recent: inspection, 25 February 2026.

Built
1989
Last inspected
25 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ8275
393603
Flag
UNITED STATES
367167380
Maury page id
psix-393603

Inspections, by type

…with no type recorded11
Years with a record 27 calendar years (1994–2026)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 24.0 ft × 6.3 ft
Registered tonnagegross 14 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKNIGHT AND CARVER CUSTOM · SAN DIEGO, CA, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationTwin Hull
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ8275MMSI 367167380 · active · voluntarily equipped · granted 2 December 2017, expires 2 December 2027
WDD6029MMSI 367167380 · expired · compulsorily equipped · granted 17 February 2007, cancelled 22 April 2017
WCO4601MMSI not assigned · expired · compulsorily equipped · granted 31 October 1994, cancelled 1 January 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KEPOIKAI II Passenger (Inspected) · MISLE 49061 · 28 September 2002 · activity 1683559

Inspection history · 72

25 February 2026 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8354409
6 February 2026 Drydock Exam · Vessel Attendance
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8302537
4 September 2025 Vessel Attendance · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8208655
19 December 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8049076
25 October 2024 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8015861
3 January 2024 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7840483
14 December 2022 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7601371
12 October 2022 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7544176
5 October 2021 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7321915
4 May 2021 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7193989
26 January 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7132022
22 October 2020 Damage Survey · Appeal
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7082460
22 October 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7105199
7 October 2020 Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7073411
28 January 2020 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6902885
13 November 2018 DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6579890
10 October 2018 Internal Structural Exam · Examination of Repairs · Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6545962
16 April 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6392801
4 December 2017 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6318073
14 April 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6124701
25 October 2016 Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6026705
5 October 2016 Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6016316
1 October 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6013635
9 May 2012 Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4306923
15 February 2011 Annual Inspection · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3946107
24 November 2010 Internal Structural Exam · Examination of Repairs · Hull Examination · Administrative Inspection · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3898407
6 January 2010 In-Service Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3664239
1 July 2009 DAPI Audit · Plan Review "T" Boat · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3520391
21 August 2008 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3297914
22 July 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3260813
24 May 2008 Deficiency Check · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3200565
19 May 2008 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3195447
12 February 2007 COI Inspection · Re-Inspection · Deadweight Survey · Deficiency Check · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2867261
26 January 2007 Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2862386
23 May 2006 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2665337
18 May 2006 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2647036
4 May 2006 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2644263
28 April 2006 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2634940
27 April 2006 Type not recorded
No type recorded · USCGC WASHINGTON (WPB 1331) · USCG Oceania District (CGD-O) · Activity 2638100
24 May 2005 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2366975
15 November 2004 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2239123
17 May 2004 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2049538
26 April 2004 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2049521
28 October 2002 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1677324
30 September 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1682241
28 September 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1683559
7 May 2002 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1611544
30 November 2001 Re-Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1379651
14 June 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1067985
11 June 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1373522
30 August 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 821979
28 August 2000 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1449375
1 June 2000 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1369724
12 November 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 807242
2 September 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1427716
8 September 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1383932
20 May 1998 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1398901
4 May 1998 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 790251
4 May 1998 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 792293
10 September 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1398748
2 October 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 838282
18 September 1996 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357734
16 April 1996 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1458293
23 October 1995 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358943
10 May 1995 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1205124
9 February 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1149653
10 January 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 866619
28 November 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 707805
26 October 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 372860
22 September 1994 Initial Certification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1412734
30 August 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377266
29 August 1994 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367160

Deficiency record · 226

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 April 2026 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 or be specifically approved by the Commandant. Hydraulic supply hose for steering gear was not SAE J-1942 approved. Install SAE J-1942 approved hose to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2026
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 September 2025 Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. Installed battery charger circuit breaker is 20-amp 2 pole. 1) prove the installed 20-amp 2 pole circuit breaker is UL 489 approved; or 2) Replace circuit breaker with UL 489 approved circuit breaker described by 46 CFR 183.380(m) of the appropriate size to the satisfaction of the attending Marine inspector (MI). 46 CFR 183.380
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 6 February 2026
Resolution: Received email from vessel rep. Eric with satisfactory photograph of the new UL 489 battery charger circuit breaker installed. Also, received documentation that the breaker is UL 489 approved.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 September 2025 Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. Installed battery charger missing fuse for each positive conductor from the charger to the battery/battery bank. Install the required UL cartridge type fuse as described by 46 CFR 183.380(k)(1)of the appropriate size for the model of battery charger installed as per the manufacturers installation instructions and approved by attending MI. 46 CFR 183.380(k)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 12 December 2025
Resolution: Observed the positive conductor from the charger to the battery/battery bank fused. Confirmed a UL cartridge fuse of the correct amperage was installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 September 2025 Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. 1) Battery charger case grounding cable not connected; 2) The manufacturer split ferrite is not installed. Complete items #1 and #2 above as per the battery charger manufacturer installation instructions to the satisfaction of the attending MI. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 12 December 2025
Resolution: Attended the vessel and observed battery charger case grounding cable connected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 September 2025 Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. Installed fuses are Marine Rated Battery Fuses on mounting bars. Replace with UL cartridge fuses of the same amperage rating to the satisfaction of the attending MI. 46 CFR 183.380(l)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 12 December 2025
Resolution: Attended vessel and the marine rated battery fuses on mounting bars were replaced with UL cartridge fuses of the same amperage rating.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 4 September 2025 No resolution recorded
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel current document from 2010 is not a sail plan. Create and submit to MSC for approval a new sail plan for the vessel that has sail areas and heights of the centers of effort for each of the sails to the satisfaction of the attending Marine Inspector. 46 CFR 176.840
Action required: 705 - Other - as specified
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 December 2024 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a through-hull fitting below the deepest load waterline. The visual alarm is inoperable for the starboard forward bilge. Repair to the satisfactory of the attending marine inspector. 46 CFR 182.530(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2025
Resolved 20 December 2024
Resolution: Light is now operable.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 January 2024 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces (1) A space with a through-hull fitting below the deepest load waterline. Vessel's starboard forward compartment's visual alarm for bilge high level is inoperable. Audible alarm is still operational. Repair bilge high level visual alarm and demonstrate operation to attending marine inspector. 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 January 2024
Resolution: Witnessed proper operation of visual and audible bilge high level alarm for starboard forward compartment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 January 2024 Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 50 pounds, and allow the waterlight to be quickly disconnected from the ring life buoy. Clip used on waterlight lanyard is seized. Replace seized clip with corrosion-resistant clip. 46 CFR 180.70(d)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 January 2024
Resolution: Received photograph from vessel owner/operator of new clip installed on waterlight lanyard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2021 Resolved
Electrical equipment must be installed to protect from electrical hazards. Multiple dead end wires were discovered on the starboard distribution panel. Properly remove to prevent potential shock or fire hazards. Cite: 46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 October 2021
Resolution: Dead end wiring cleaned up satisfactorily.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 October 2021 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. High water level indicators are not labeled. Label indicators corresponding to particular indicator.
Action required: 10 - Deficiency Rectified
Resolved 5 October 2021
Resolution: Labeled indicators during inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2021 Resolved
Each circuit breaker must meet UL 489 (incorporated by reference; see 46 CFR 175.600) or other standard specified by the Commandant, and be of the manually reset type designed for instantaneous short circuit protection. Change incorrect fuse for the compass light from 5 amp to 2.5 amp. 46 CFR 183.380(m)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 27 December 2021
Resolution: Vessel Rep. received and installed properly rated fuse verified by [name withheld] included in Documents workflow.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 October 2021 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are employed. The following sail rigging components were deemed to need verification by third party surveyor so that they are suitable for continued service: Clevis pin and stbd chain-plate. The vessel is not authorized to operate under sail until this deficiency has been cleared by a USCG Marine Inspector. 46 CFR 176.840
Action required: 705 - Other - as specified
Due 5 October 2021
Resolved 6 October 2021
Resolution: Spoke with third party rigger [name withheld] who attested to the integrity of clevis pin and chain plate in question and determined color was due to staining.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 January 2021 Resolved
Inspection of each watertight closure in the hull is required at each annual inspection. Rubber boot/gasket for port steering ram penetration leaking stream of water into port lazerette. Repair to the satisfaction of the attending marine inspector prior to carrying passengers. 46 CFR176.802(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2021
Resolution: Vessel renewed gasket same day.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 January 2021 Resolved
On a vessel of at least 36 feet in length, a visual and audible alarm must be provided at the operation to indicate a high water level. Vessels high water alarm light in the port lazarette inoperable and audible sound insufficient. 46 CFR 182.530 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 February 2021
Resolved 9 February 2021
Resolution: Alarm sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 26 January 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passers, crew, and the vessel from electrical hazards, including fire, causte by or originating in electrical equipment, and electric shock. Vessels negative battery cable for the stbd engine trim motors insulation is deteriorated and in need of replacement, appears to have melted. 46 CFR 183.200 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 February 2021
Resolved 9 February 2021
Resolution: Vessel renewed wire.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 January 2021 Resolved
Inspection of all spars, standing rigging, running rigging, blocks, fittings, and sails shall be made at each annual on sailing vessels. Stbd lower wire chain plate had running rust from third bolt from the bottom. Remove for inspection. 46CFR 176.802(a)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 February 2021
Resolved 9 February 2021
Resolution: Vessel renewed bolt.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 January 2021 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520 (1) only on a vessel of not more than 65 feet carrying not more than 49 passengers provided that: The pump is listed by an independent laboratory as meeting the requirements in UL 1113. Vessels four electric submersible bilge pumps do not appear to be listed as meeting UL 1113. Provide evidence of pumps meeting UL 1113 or replace with sutible pumps IAW 46 CFR 182.520 (e) 46 CFR 182.520 (e)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2021
Resolved 9 February 2021
Resolution: Vessel replaced with UL listed pumps.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 26 January 2021 Resolved
Conductors must be protected in accordance with their current carrying capacities. Provide evidence of rated power, voltage, length of wire runs, current wire gauge, and overcurrent protection for engine trim hydraulic motors. 46 CFR 183.380 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2021
Resolved 9 March 2021
Resolution: Vessel provided information requested.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 26 January 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passers, crew, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electric shock. Vessels trim motors not wired IAW electrical plans. Wire to approved plans or resubmit plans to MSC for updates. 46 CFR 183.200 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 4 May 2021
Resolution: Vessel wired overcurrent protection IAW approved electrical plans.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 October 2020 Resolved
The Cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. NA HOKU II struck a recreational vessel and requires a damage survey.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2020
Resolution: Damage survey completed by marine inspectors and third party survey conducted by rigger [name withheld].
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 22 October 2020 Resolved
Repairs and alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without approval of the cognizant OCMI. Vessel has damaged bow cross beam. Submit repair proposal to Sector Honolulu Inspections Division for review an approval.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 November 2020
Resolution: Temporary repair completed to the satisfaction of the attending marine surveyor.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 22 October 2020 Resolved
Repairs and alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without approval of the cognizant [name withheld] repair to vessel's forward crossbeam approved by Sector Honolulu OCMI and completed satisfactorily. Vessel must monitor temporary repair in accordance with their proposal submitted 10 November, 2020 and report any changes to the condition of the repair to the Sector Honolulu Inspections Division. Permanent repairs to the forward crossbeam must be completed no later than 6 November, 2021.
Action required: 705 - Other - as specified
Resolved 5 November 2021
Resolution: Permanent crossbeam repairs complete; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 February 2020 Resolved
The owner shall be prepared to conduct tests and have the vessel ready for inspection of the following: On a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Vessel has been keeping adequate maintenance records however does not have a current inventory list in accordance with USCG NVIC 02-16.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2020
Resolved 27 February 2020
Resolution: Vessel provided current rig inventory. Attached in documents.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 January 2020 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Vessels masthead light inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2020
Resolution: Vessel replaced mastead light fuse, all sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 28 January 2020 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). VHF radio missing MMSI and LAT/LONG for DSC operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2020
Resolution: Vessel purchased new VHF, all sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 28 January 2020 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Vessels structural support post for upper deck found with bottom attachment point unscrewed and floating 1/4” above deck. Vessel rep stated post is designed to float up and down however post was corroded and would not move. Return to original condition.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2020
Resolved 27 February 2020
Resolution: Vessel freed stuck bolts and reattached to deck.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 January 2020 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Pin on vessels forestay suspected to be fractured. Replace in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 February 2020
Resolution: Vessel replaced pin.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2020 Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Vessel has unsupported cable in lazarette.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2020
Resolution: Vessel supported wires.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 28 January 2020 Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited, the operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods include - (1) closing each valve and removing the handle; (2) padlocking each valve in the closed position; (3) Using a non-releasable wire tie to hold each valve in the closed position. Vessel has type III MSD system with no valve installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2020
Resolved 27 February 2020
Resolution: Vessel installed valve and will keep closed/ remove handle from pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 November 2018 Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation; vessel's port aft bilge pump indicator light is not operational. Prove proper operation of light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 November 2018
Resolution: Attending MI verified proper operation of light.
Operations/Management › Vessel Activity › Underway
Issued 11 December 2017 Resolved
Operational sea trials to be conducted. Recommended by [name withheld] to have minimum of 18 to 20 knots true wind speed with minimum of 60% passenger loading capacity.
Action required: 705 - Other - as specified
Due 11 January 2018
Resolved 6 January 2018
Resolution: Underway test conducted.
Sail Rigging › Catamaran › Crossbeam
Issued 7 December 2017 Resolved
Have 3rd party rigging survey completed to address structural/rigging areas of concern.
Action required: 705 - Other - as specified
Due 11 December 2017
Resolved 11 December 2017
Resolution: 3rd party survey complete. Recommended sea trial within 30 days. Issuing new 835 for this requirement.
Navigation › Piloting/Steering › Marine Charts
Issued 7 December 2017 Resolved
Provide updated navigational charts for areas of operation
Due 14 December 2017
Resolved 14 December 2017
Resolution: Charts updated
Communications › Radio Communications › VHF Radiotelephone
Issued 7 December 2017 Resolved
Provide emergency broadcast placard at helm near radio location
Due 7 January 2018
Resolved 21 February 2018
Resolution: Completed as required.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 7 December 2017 Resolved
Change radio station authorization call sign back to old, or update all other paperwork with new call sign
Due 7 January 2018
Resolved 7 February 2018
Resolution: New call sign issued on certificate
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 December 2017 Resolved
Post COI
Due 14 December 2017
Resolved 14 December 2017
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 7 December 2017 Resolved
Provide DAPI proof of random testing.
Due 14 December 2017
Resolved 14 December 2017
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 25 October 2016 Resolved
05 life jackets unserviceable; reduce PAX count until replaced IAW 46 CFR 180.71
Due 11 November 2016
Resolved 28 October 2016
Resolution: Life jackets provided prior to completion of exam.
Engineering › Bilge Water Management System › Pump
Issued 25 October 2016 Resolved
No manual operation of bilge pumps; ensure bilge pumps operate IAW 46 CFR 182.520(a)
Due 18 November 2016
Resolved 28 November 2016
Resolution: Manual operation of bilge pumps demonstrated.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 25 October 2016 Resolved
Supervisors have not receved 60 minutes of drug awareness training; provide verification of training IAW 46 CFR 16.401
Due 28 November 2016
Resolved 1 December 2016
Resolution: 60 minutes of drug awareness training provided to supervisors.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 25 October 2016 Resolved
Crew does not meet requirements of DAPI program; request DAPI audit IAW 46 CFR 16
Due 28 November 2016
Resolved 1 December 2016
Resolution: DAPI requirements for crew met.
Navigation › Piloting/Steering › Marine Charts
Issued 25 October 2016 Resolved
Current nautical chart onboard is out of date; provide updated nautical chart IAW 46 CFR 184.420.
Due 11 November 2016
Resolved 10 November 2016
Resolution: Charts and pubs updated.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 25 October 2016 Resolved
Portable fire extinguisher mounting brackets not approved type; install approved type brackets IAW 46 CFR 162.028(g)
Due 28 November 2016
Resolved 10 November 2016
Resolution: Portable fire extinguisher brackets replaced.
Engineering › Bilge Water Management System › Valve
Issued 25 October 2016 Resolved
Shut off valves not installed at hull penetration for bilge piping; instal IAW 46 CFR 182.520(e)(7)
Due 18 November 2016
Resolved 28 November 2016
Resolution: Shut off valves installed at hull penetrations.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 25 October 2016 Resolved
Fuses and circuit breakers installed onboard are not UL listed, install approved overcurrent protection IAW 46 CFR 183.380(l)(m)
Due 18 November 2016
Resolved 14 April 2017
Resolution: Adequate overcurrent protection installed to include new electrical panel with appropriate circuit breakers and fuses.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 October 2016 Resolved
Provided line diagram does not reflect installed equipment; provide updated electrical line diagram IAW 46 CFR 176.800
Due 28 November 2016
Resolved 16 April 2018
Resolution: Received line drawings as required
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 25 October 2016 Resolved
Life jacket utilized during man overboard recovery that is teathered to the vessel is not load bearing; provide load bearing harness or equivalent IAW 46 CFR 176.800
Due 11 November 2016
Resolved 10 November 2016
Resolution: Load bearing harness purchased and installed to be used when conducting drills.
Unknown
Issued 25 October 2016 Resolved
Emergency instructions do not reflect equipment installed onboard; ensure emergency instructions posted are specific to the vessel and its equipment IAW 46 CFR 185.510
Due 11 November 2016
Resolved 10 November 2016
Resolution: Updated emergency instructions provided/displayed.
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 25 October 2016 Resolved
Sufficient ventilation not provided to the batteries; provide adequate ventilation for batteries IAW 46 CFR 183.354(b)
Due 28 November 2016
Resolved 14 April 2017
Resolution: Sufficient ventilation provided to the batteries.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 25 October 2016 Resolved
Vital loads do not have two separate power sources; ensure two suitable power sources are installed for vital loads IAW 46 CFR 183.310
Due 28 November 2016
Resolved 18 January 2017
Resolution: Two suitable power sources verified for vital loads.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 October 2016 Resolved
Conductors for indicator lights are the incorrect size; ensure conductors are at least 22 AWG IAW 46 CFR 183.340(c)
Due 18 November 2016
Resolved 18 January 2017
Resolution: Indicator light circuits removed.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 25 October 2016 Resolved
Indicator circuits are not supplied with overcurrent protection; ensure approved overcurrent protection is installed IAW 46 CFR 183.380(c)
Due 2 November 2016
Resolved 18 January 2017
Resolution: Indicator circuits removed.
Communications › Radio Communications › VHF Radiotelephone
Issued 25 October 2016 Resolved
Installed VHF radio not located at the operating station, hand held radios used do not meet the mounting or charging requirements; ensure radio installation meets requirements IAW 47 CFR 80.905(a)(5)(d)
Due 28 November 2016
Resolved 18 January 2017
Resolution: VHF radio relocated to operating station.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 February 2011 Resolved
Install metal fasteners for wire runs every 24 inches IAW 46CFR 183.710.
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 24 February 2011
Resolution: Vessel found to be in compliance with ABYC standards for vessels under 65 feet.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 15 February 2011 Resolved
Provide red cross first aid and /CPR cards for 50% of crew.
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 24 February 2011
Resolution: All company employees attended first aid/CPR training
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 15 February 2011 Resolved
Provide valid marine operator permit
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 24 February 2011
Operations/Management › Passenger Operations › Safety Orientation
Issued 15 February 2011 Resolved
Provide safety orientation card.
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 24 February 2011
Resolution: Installed orientation card
Operations/Management › Drills/Instruction › Safety Orientation
Issued 15 February 2011 Resolved
Post emergency instructions IAW 46CFR185.510
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 24 February 2011
Resolution: Emergency instructions posted
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 February 2011 Resolved
No passengers allowed on netting while vessel is underway IAW 46CFR177.900
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 24 February 2011
Resolution: Vessel installed barriers to prevent passengers from access to netting while underway
Fire Fighting › Fire Bucket › Capacity
Issued 15 February 2011 Resolved
Provide 2.5 gallon fire buckets IAW 46CFR181.610
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 24 February 2011
Resolution: Provided 2 1/2 gallon fire buckets
Engineering › Bilge Water Management System › Interface Detector
Issued 15 February 2011 Resolved
Prove proper operation of high water visual indicator IAW 46CFR182.530
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 24 February 2011
Resolution: Installed visual indicator
Engineering › Bilge Water Management System › Interface Detector
Issued 15 February 2011 Resolved
Prove proper operation of visual indicator for automatic bilge pump
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 24 February 2011
Resolution: Installed new indicators
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 15 February 2011 Resolved
Post no smoking signs near portable gasoline fuel tanks
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 24 February 2011
Resolution: No smoking signs posted
Personnel › Certificates/Documents/Licenses › License, Master
Issued 15 February 2011 Resolved
Provide original master license.
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 24 February 2011
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 15 February 2011 Resolved
Provide EAP material to complete chemical testing audit.
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 24 February 2011
Construction/Loadline › Structures › Superstructure
Issued 15 February 2011 Resolved
Provide suffecient safety factor on newly installed bridle based upon operational load test. Marine inspector shall be present to witness tests.
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 21 November 2011
Resolution: Conducted load testing resulting in safety factor of 8:1
Construction/Loadline › Hull › Transverse Frame
Issued 30 November 2010 Resolved
Provide a repair proposal drafted by a marine surveyor or naval architect for USCG review/approval for the cracked frame in port lazarette and fractures in the cross beam forward/overhead/inboard in #2 voids (port and starboard).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2011
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 29 November 2010 Resolved
Renew retroreflective material on 2 lifejackets identified during inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2011
Lifesaving › Lifefloat › Retroreflective Material
Issued 29 November 2010 Resolved
Renew retroreflective material on both lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2011
Construction/Loadline › Structures › Superstructure
Issued 29 November 2010 Resolved
Provide rigging maintenance schedule and documentation of daily inspections in accordance with CID Note 13.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2011
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 29 November 2010 Resolved
Provide current copy of tide tables.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2011
Documentation › Certificates/Documents › Stability Letter
Issued 29 November 2010 Resolved
Post copy of current COI and stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2011
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 November 2010 Resolved
Monitor fractures on cross beam in overhead port and starboard sides in #2 space forward. Make available for USCG inspection at quarterly ISE. Make repairs at next drydock or sooner if directed by USCG inspector.
Action required: 705 - Other - as specified
Resolved 15 February 2011
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 November 2010 Resolved
Submit repair plan for USCG approval of 2 fractures in port lazarette ring frame prior to conducting repairs. Once plan is approved, complete repairs to the satisfaction of the USCG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2011
Engineering › Steering Gear System › Hydraulic Hose
Issued 29 November 2010 Resolved
Repair oil leaks on starboard steering ram aft hoses.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2011
Construction/Loadline › Hull › Bottom Plating
Issued 29 November 2010 Resolved
Repair water ingress in starboard steering space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2011
Operations/Management › Drills/Instruction › Fire
Issued 29 November 2010 Resolved
Conduct crew proficiency drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2011
Lifesaving › Lifefloat › Lifeline
Issued 29 November 2010 Resolved
Renew line on lifefloat line with approved line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 November 2010 Resolved
Vessel failed to complete annual COI inspection within required 90 day window of anniversary date. Vessel may not carry passengers until inspection is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 December 2010
Resolved 15 February 2011
Construction/Loadline › Hull › Side Shell
Issued 13 April 2010 Resolved
Haul out vessel to conduct permanent repairs to hull fractures throughout amidships and lazarette spaces. Fractures have progressed quickly since last drydock in Sept 2009, and repairs need to be made. Submit repair proposal for USCG approval prior to conducting repairs.
Action required: 705 - Other - as specified
Due 13 May 2010
Resolved 8 September 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 January 2010 Resolved
Replace twist wire connectors on hydraulic pump in port lazarette with crimped connectors unless they are located in the junction box. Replace cover on junction box. Remove dead-ended wires.
Action required: 705 - Other - as specified
Due 6 February 2010
Resolved 3 February 2010
Engineering › Steering Gear System › Hydraulic Hose
Issued 6 January 2010 Resolved
Repair hydraulic leak at pump in starboard lazarette.
Action required: 705 - Other - as specified
Due 6 February 2010
Resolved 3 February 2010
Resolution: Hyrdaulic leak repaired, pump is in the process of being relocated to the amidships accomodation space void. Hyrdaulic rams were bent and are being repaired. Vessel has rigged a temporary block and tackle system to lift outboard as needed.
Construction/Loadline › Hull › Bottom Plating
Issued 6 January 2010 Resolved
Continuously monitor hull fractures in port lazarette and starboard amidships spaces. Make spaces available for USCG inspection every three months. Make repairs at next drydock or sooner as determined by the USCG marine inspector.
Action required: 705 - Other - as specified
Due 31 August 2011
Resolved 8 September 2010
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 January 2010 Resolved
Post COI in an area visible to passengers.
Action required: 705 - Other - as specified
Due 6 February 2010
Resolved 3 February 2010
Resolution: COI was posted, but it was the incorrect copy. Will mail new copy to vessel operator.
Construction/Loadline › Hull › Hull Plating
Issued 6 January 2010 Resolved
Repair identified weeping hull cracks. Cracks are identified by "weeping" written by them. There is 1 in starboard amidships void and 2 in port amidships void.
Due 12 April 2010
Resolved 13 April 2010
Resolution: Cracks were repaired but are still weeping, a new CG-835 was issued to have the vessel go to drydock to make permenant repairs to hull fractures.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 31 July 2009 Resolved
Vessel is restricted from carrying passengers for hire until 2 chain plates identified as being improperly installed are re-installed to the satisfaction of the attending marine inspector. Provide plans for approval prior to installation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2009
Resolution: Received plans from [name withheld] approved by [name withheld] for chainplate installation.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 1 July 2009 Resolved
Provide current first aid/CPR card for 50% of crew.
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 28 August 2009
Communications › Radio Communications › EPIRB
Issued 1 July 2009 Resolved
Properly install and provide current registration for EPIRB. Vessel is restricted to within 3NM from shore until proof is provided of registration and installation verified by USCG.
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 28 August 2009
Navigation › Piloting/Steering › Coast Guard Light List
Issued 1 July 2009 Resolved
Provide copy of most current light list.
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 28 August 2009
Communications › Radio Communications › EPIRB
Issued 1 July 2009 Resolved
Properly log monthly EPIRB tests.
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 28 August 2009
Navigation › Piloting/Steering › Marine Charts
Issued 1 July 2009 Resolved
Provide corrected charts to most recent local notice to mariners for operating area.
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 28 August 2009
Lifesaving › Lifebuoys › Approval
Issued 1 July 2009 Resolved
Renew damaged retro reflective tape on all ring buoys.
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 28 August 2009
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 July 2009 Resolved
Renew batteries in all water lights.
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 28 August 2009
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 1 July 2009 Resolved
Lock or provide alternate means of securing MSD overboard valve.
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 28 August 2009
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 1 July 2009 Resolved
Resolve all discrepancies identified during chemical testing program compliance audit. Need to provide drug/alcohol devices on board. Need to display EAP numbers. Need to give supervisors 1 hr EAP training and provide records. Need to provide 2008 MIS report. Need to provide 2009 contract for consortium.
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 1 September 2009
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 1 July 2009 Resolved
Provide proper sized bell IAW navigation rules.
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 28 August 2009
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 1 July 2009 Resolved
Provide proof of sailing vessel rigging inspection program using Inspection Note 13 for guidance.
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 28 August 2009
Documentation › Certificates/Documents › Stability Letter
Issued 1 July 2009 Resolved
Post COI/stability letter on vessel.
Action required: 705 - Other - as specified
Due 1 July 2009
Resolved 1 July 2009
Fire Fighting › Fire Bucket › Stenciling
Issued 1 July 2009 Resolved
Provide lanyard for 1 fire bucket. Properly label 1 fire bucket.
Action required: 705 - Other - as specified
Due 1 July 2009
Resolved 1 July 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 July 2008 Resolved
Found temporary COI onboard which expires on 23Aug2008. Post full-term COI on vessel.
Condition: Unknown
Due 21 August 2008
Resolved 21 August 2008
Resolution: Hand delivered amended full-term COI to the vessel.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 22 July 2008 Resolved
There is no record of acknowledgement of understanding of the company drug policy or EAP signed by safety employeed personnel. Provide signed acknowledgement of EAP.
Due 21 August 2008
Resolved 11 August 2008
Resolution: Received mailed copies of signed acknowledgements of company''s EAP.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 22 July 2008 Resolved
The emergency broadcaset placard is not posted where it can be seen. Post emergency placard at the steering station where it can be seen.
Due 21 August 2008
Resolved 21 August 2008
Resolution: Sighted Emergency Broadcast placard posted at the steering station where it can be seen in an emergency.
Lifesaving › Lifefloat › Netting
Issued 22 July 2008 Resolved
The port lifefloat has a broken net frame and the stbd lifefloat has a 1" square chunk gouged out of it. Repair both lifefloats.
Due 21 August 2008
Resolved 21 August 2008
Resolution: Sighted satisfactory repairs to lifefloats.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 July 2008 Resolved
The 1st aid kit contained expired aspirin, eye wash, and iodine. Replace expired items.
Due 21 August 2008
Resolved 21 August 2008
Resolution: Sighted complete and current 1st aid kit.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 22 July 2008 Resolved
The onboard Light List is dated 2006. Provide appropriate pages from the 2008 Light List.
Due 21 August 2008
Resolved 21 August 2008
Resolution: Sighted 2007 (which is current) Light List.
Engineering › Gasoline Engine (propulsion) › Spark Plug (4 cycle)
Issued 24 May 2008 Resolved
Engine failed during operation on afternoon of 24May2008. Complete repairs and prove proper operation of engine. Vessel is auxiliary sail and operator voluntarily ceased operations upon being contacted. No operational controlled issued.
Action required: 705 - Other - as specified
Due 25 May 2008
Resolved 25 May 2008
Resolution: Witnessed satisfactory operation of both propulsion engines.
Engineering › Steering Gear System › Rudder
Issued 19 May 2008 Resolved
The port rudder cheek is fractured and splitting. Construction is of stainless steel. Complete repair t fractured rudder cheek.
Action required: 705 - Other - as specified
Due 18 June 2008
Resolved 22 May 2008
Resolution: Sighrted repaired cheekplate being prepared for reinstallation.
Construction/Loadline › Hull › Hull Plating
Issued 19 May 2008 Resolved
Noted multiple areas of delaminating FRP on port and stbd hull bottoms: Port - 13' from bow, amidships deep gouge 1'long X 1/2" wide X 1/8" deep, 13' from stern bottom and outboard 1st layer. Stbd - 13' from stem for (3) feet, 1' forward of amidship chain plate. Grind to good material and repair.
Action required: 705 - Other - as specified
Due 18 June 2008
Resolved 22 May 2008
Resolution: Sighted smooth sacrificial glass relaid under both hulls.
Construction/Loadline › Hull › Sheerstrake
Issued 19 May 2008 Resolved
Noted (3) areas of temporary putty repairs on the stbd stem. Grind out and repair.
Action required: 705 - Other - as specified
Due 18 June 2008
Resolved 22 May 2008
Resolution: Sighted proper repairs made to stem.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 May 2008 Resolved
Note tread is coming u on port bow ladder and men's head ladder. Replace/re-secure tread.
Action required: 705 - Other - as specified
Due 18 June 2008
Resolved 22 May 2008
Resolution: Existing tread was reglued. Owner states he is still looking for new material.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 19 May 2008 Resolved
Stbd propeller is bent on all (3) blade tips and chipped on one blade tip. Replace bent and chipped stbd propeller.
Action required: 705 - Other - as specified
Due 18 June 2008
Resolved 22 May 2008
Resolution: Sighted a used propeller in good condition installed on the stbd outboard engine.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 19 May 2008 Resolved
Noted (1) deck fastener in the wing section forward end of the stbd aft compartment is visibly rusted. Replace this one fastener.
Action required: 705 - Other - as specified
Due 18 June 2008
Resolved 22 May 2008
Resolution: The deck fastener was replaced in kind.
Construction/Loadline › Hull › Stiffener
Issued 19 May 2008 Resolved
The visible wing frame at the stbd hull is missing the front endpiece (see port wing frame). Repair/replace the stbd wing frame. Strengthening with a sister is ok.
Action required: 705 - Other - as specified
Due 18 June 2008
Resolved 22 May 2008
Resolution: The visible wing frame near the stbd end was strengthened by fiberglassing a new endpierce in place.
Engineering › Bilge Water Management System › Pump
Issued 19 May 2008 Resolved
The electric bilge pump and alarm for the stbd hull have worked themselves loose from their fasteners. Re-secure and prove operation of the stbd and port bilge alarm and pumps.
Action required: 705 - Other - as specified
Due 18 June 2008
Resolved 22 May 2008
Resolution: The stbd bilge pump and alarm were tightened in place. Port and stbd alarms and bilge pumps tested satisfactorily.
Electrical › Electrical Distribution System (service) › Cable
Issued 19 May 2008 Resolved
Found dead-ended wiring for lights or speakers in the port and stbd hulls just forward of the toilets. Properly make off or remove dead-ended lighting wires.
Action required: 705 - Other - as specified
Due 18 June 2008
Resolved 22 May 2008
Resolution: Excess unused wiring was removed.
Construction/Loadline › Structures › Superstructure
Issued 13 June 2007 Resolved
Provide USCG MSC a thorough Mast Construction Drawing detailing all dimensions, materials, weights and measurements of new mast.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2007
Resolved 21 August 2007
Construction/Loadline › Structures › Superstructure
Issued 13 June 2007 Resolved
Provide USCG MSC Rigging and Sail Plans along with required Stability Calculations for a Sailing Catamaran
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2007
Resolved 21 August 2007
Construction/Loadline › Structures › Superstructure
Issued 13 June 2007 Resolved
Provide Structural Approval Letters from USCG MSC along with stamped and approved Mast Construction Drawing, Rigging and Sail Plans and Stability Calculations
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2007
Resolved 21 August 2007
Construction/Loadline › Structures › Superstructure
Issued 13 June 2007 Resolved
Complete a Verification Inspection of all USCG Approved Plans and Equipment with USCG Marine Inspector in attendance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2007
Resolved 23 August 2007
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 13 June 2007 Resolved
Conduct operational test with USCG Marine Inspector to determine Adequate Stability & Handling Characteristics under sail
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2007
Resolved 23 August 2007
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 13 June 2007 Resolved
Provide Rigging Surveyor Report from Qualified Marine Surveyor attesting to the satisfactory condition of all Rigging, Mast, Sail and associated equipment
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2007
Resolved 23 August 2007
Navigation › Piloting/Steering › Marine Charts
Issued 12 February 2007 Resolved
Provide a current chart for area of operation (Mamala Bay) and tidal current tables In accordance with 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 23 August 2007
Resolved 23 August 2007
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 12 February 2007 Resolved
Replace two unservicable Adult PFD's in accordance with 46 CFR 180. Maximum passengers permitted reduced to 55 until replaced.
Action required: 705 - Other - as specified
Due 23 August 2007
Resolved 23 August 2007
Operations/Management › Equipment Service/Testing › EPIRB
Issued 12 February 2007 Resolved
Properly mount EPIRB in a float-free arrangement in accordance with 46 CFR 185.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 August 2007
Resolved 23 August 2007
Operations/Management › Drills/Instruction › Fire
Issued 12 February 2007 Resolved
Perform satisfactory fire and man overboard drills in the presence of a USCG marine inspector.
Action required: 705 - Other - as specified
Due 23 August 2007
Resolved 23 August 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 February 2007 Resolved
Prove compliance with mandatory drug and alcohol program in accordance with 46 CFR 16.
Action required: 705 - Other - as specified
Due 28 February 2007
Resolved 28 February 2007
Lifesaving › Lifebuoys › Stowage
Issued 23 May 2006 Resolved
Properly mount life ring mounting brackets.
Condition: Improper Installation
Due 23 June 2006
Resolved 24 May 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 May 2006 Resolved
Provide bracket and float light for starboard aft float ring.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2006
Resolved 24 May 2006
Engineering › Bilge Water Management System › Interface Detector
Issued 23 May 2006 Resolved
Prove proper operation of aft high level alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2006
Resolved 23 May 2006
Fire Fighting › Fire Bucket › Lanyard
Issued 23 May 2006 Resolved
Provide 3 fire buckets with lines.
Condition: Improper/Lack of Maintenance
Due 23 June 2006
Resolved 24 May 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 23 May 2006 Resolved
Provide safety lines for openings in handrails.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2006
Resolved 24 May 2006
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 23 May 2006 Resolved
Provide current charts & nautical publications as per 46 CFR 184.420.
Condition: Improper/Lack of Maintenance
Due 23 June 2006
Resolved 24 May 2006
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 23 May 2006 Resolved
Renew wasted sail winch mountings bolt or rivets.
Condition: Improper/Lack of Maintenance
Due 23 June 2006
Resolved 24 May 2006
Documentation › Logs/Records › Logbook (official)
Issued 23 May 2006 Resolved
Provide log book to maintained on the vessel.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2006
Resolved 24 May 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 April 2006 Resolved
Operating w/o a valid COI (46 CFR 71.01-1(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 April 2006 Resolved
Failure to conduct a required COI re-inspection for passenger vsls <1600GRT (46 CFR 71.30-1).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 April 2006 Resolved
Continuing to operate w/o a valid COI approx. 4 trips per day w/ average of 15 POB as of 28AUG05 per NA HOKU II passenger logs (46 CFR 71.01-10(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 27 April 2006 Resolved
Operating with an expired Certificate of Documentation (46 CFR 67.315).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 27 April 2006 Resolved
PFDs were not in serviceable condition; provide (39) adult Type I & (1) child Type I (46 CFR 25.25-11).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 27 April 2006 Resolved
Provide operable float light mounted to required bracket (46 CFR 25.25-11).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Lifesaving › Lifefloat › Serviceable
Issued 27 April 2006 Resolved
Repair or replace (x2) life floats (46 CFR 25.25-11).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Lifesaving › Lifefloat › Float-free Link
Issued 27 April 2006 Resolved
Provide operable lifefloat weak link (46 CFR 25.25-11).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Engineering › Bilge Water Management System › Not Operational
Issued 27 April 2006 Resolved
Failure to comply w/ the requirements for bilge pumps, piping, and dewatering systems. Provide operable STBD Head & PORT bilge alarm & bilge pumps (46 CFR 28.255).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 27 April 2006 Resolved
Provide (1) life ring with required retroreflective tape (46 CFR 28.115).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Communications › Alarms/Indicators › High Water Alarm
Issued 27 April 2006 Resolved
Provide operable high water alarm visual indicators at operating station (46 CFR 28.250).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Documentation › Certificates/Documents › FCC SSL
Issued 27 April 2006 Resolved
Provide valid FCC safety certificate (33 CFR 26.03/46 CFR 28.245).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 27 April 2006 Resolved
Failure to equip vsl w/ required navigational charts & publications (46 CFR 28.255).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 27 April 2006 Resolved
Failure of a maritime employer to conduct required random chemical testing; provide proof of DAPI program (46 CFR 16.230).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Documentation › Logs/Records › Logbook (official)
Issued 27 April 2006 Resolved
Provide all required logs & manuals (i.e. passenger manifest, training logs, lifesaving equip. maintenance records, bridge logs) 46 CFR 35.07-5).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Construction/Loadline › Hull › Double Hull
Issued 27 April 2006 Resolved
Repair STBD AFT hull leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Stability › Severe Wind/Roll › General
Issued 27 April 2006 Resolved
Provide rigging survey.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 April 2006 Resolved
Provide required STBD Head light cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2006
Resolution: Corrected during COI inspection Activity #2665337.
Lifesaving › Lifejacket/PFD (Type II) › Condition
Issued 15 November 2004 Resolved
Provide (2) adult CG approved lifejackets. Passenger count reduced to 47 passengers.
Condition: Unknown
Due 15 November 2004
Resolved 7 January 2005
Resolution: Provided (2) adult CG approved PFDs. Passenger count restriction rescinded.
Navigation › Piloting/Steering › US Coast Pilot
Issued 15 November 2004 Resolved
Provide US Coast pilot.
Condition: Unknown
Due 30 November 2004
Resolved 7 January 2005
Resolution: Provided US Coast Pilot.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 15 November 2004 Resolved
Provide tidal current tide tables.
Condition: Unknown
Due 30 November 2004
Resolved 7 January 2005
Resolution: Provided tidal current tide tables.
Lifesaving › Buoyant Apparatus › Painter
Issued 15 November 2004 Resolved
Provide sea painter, weak link and new line for portside light.
Condition: Unknown
Due 30 November 2004
Resolved 7 January 2005
Resolution: Provided sea painter, weak link and new line for portside light.
Communications › Radio Communications › EPIRB
Issued 15 November 2004 Resolved
Provide NOAA registration for EPIRB.
Condition: Unknown
Due 30 November 2004
Resolved 7 January 2005
Resolution: Provided NOAA registration for EPIRB.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 15 November 2004 Resolved
Provide safety orientation card or pamphlet.
Condition: Unknown
Due 30 November 2004
Resolved 7 January 2005
Resolution: Provided safety orientation card or pamphlet.
Fire Fighting › Fire Bucket › Quantity
Issued 15 November 2004 Resolved
Provide (2) 2.5 gallon fire buckets with markings and attached lanyards.
Condition: Unknown
Due 30 November 2004
Resolved 7 January 2005
Resolution: Provided (2) 2.5 gallon fire buckets with markings and attached lanyards.
Engineering › Bilge Water Management System › Interface Detector
Issued 15 November 2004 Resolved
Provide highwater/bilge visual indicator at operating station.
Condition: Unknown
Due 30 November 2004
Resolved 7 January 2005
Resolution: Provided highwater/bilge visual indicator at operating station.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 15 November 2004 Resolved
Provide means for securing discharge valve for both MSD.
Condition: Unknown
Due 30 November 2004
Resolved 7 January 2005
Resolution: Provided means for securing discharge valve for both MSD.
Documentation › Certificates/Documents › Stability Letter
Issued 15 November 2004 Resolved
Provide stability letter.
Condition: Unknown
Due 22 November 2004
Resolved 7 January 2005
Resolution: Provided stability letter.
Stability › Watertight Integrity › Deadlight Cover
Issued 15 November 2004 Resolved
Provide dead light covers.
Condition: Unknown
Due 30 November 2004
Resolved 24 May 2005
Resolution: Openings were enclosed and new openings created above weatherdeck.
Lifesaving › Lifebuoys
Issued 26 April 2004 Resolved
Provide connecting line between Life Floats. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Due 26 May 2004
Resolved 3 June 2004
Lifesaving › Lifebuoys
Issued 26 April 2004 Resolved
Provide a set of two (2) 4 ft paddles with markings for each Life Float.
Condition: Improper/Lack of Maintenance
Due 26 May 2004
Resolved 3 June 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 26 April 2004 Resolved
Vessel is restricted to a total of 47 persons on board until additional PFDs are provided. Vessel restricted to a maximum of seven (7) persons under 90lbs. LEGACY COMPONENT DESC: Quantity
Condition: Improper/Lack of Maintenance
Due 26 May 2004
Resolved 3 June 2004
Navigation › Piloting/Steering
Issued 26 April 2004 Resolved
Provide current CG Light List, Coast Pilot, and Navigation Rules Book on board.
Condition: Improper/Lack of Maintenance
Due 26 May 2004
Resolved 3 June 2004
Personnel › Certificates/Documents/Licenses
Issued 26 April 2004 Resolved
Provide evidence that one person from crew has a current CPR certification. LEGACY COMPONENT DESC: Certificate, CPR Course Completion
Condition: Improper/Lack of Maintenance
Due 26 May 2004
Resolved 3 June 2004
Personnel › Certificates/Documents/Licenses
Issued 26 April 2004 Resolved
Provide evidence of one person from crew with current First Aid certification. LEGACY COMPONENT DESC: Certificate, First Aid Course Completion
Condition: Improper/Lack of Maintenance
Due 26 May 2004
Resolved 3 June 2004
Electrical › Electric Supply System (service)
Issued 26 April 2004 Resolved
Provide non corrosive battery box for port side battery. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Due 26 May 2004
Resolved 3 June 2004
Documentation › Logs/Records
Issued 26 April 2004 Resolved
Provide log book to log required drills and record maintenance of lifesaving equipment. LEGACY COMPONENT DESC: Logbook (official)
Condition: Improper/Lack of Maintenance
Due 26 May 2004
Resolved 3 June 2004
Pollution Prevention/Response › Prevention Equipment
Issued 26 April 2004 Resolved
Provide a method to secure the sewage overboard pump. LEGACY COMPONENT DESC: Overfill Devices
Condition: Improper/Lack of Maintenance
Due 26 May 2004
Resolved 3 June 2004
Documentation › Certificates/Documents
Issued 28 October 2002 Resolved
Provide FCC Safety Certificate IAW FCC 184.502. LEGACY COMPONENT DESC: FCC Safety Certificate
Due 28 November 2002
Resolved 26 April 2004
Resolution: Provided FCC Safety Certificate during 3rd annual - Periodic inspection.
Operations/Management › Drug and Alcohol Testing
Issued 28 October 2002 Resolved
Provide compliance with Drug and Alcohol Program IAW 46 CFR 16.
Condition: Unknown
Due 28 November 2002
Resolved 26 April 2004
Resolution: Provided compliance with Drug and Alcohol Program during 3rd Annual - Periodic inspection.
Communications › Radio Communications
Issued 28 October 2002 Resolved
Provide valid NOAA registration IAW 46 CFR 185.728. LEGACY COMPONENT DESC: EPIRB
Due 28 November 2002
Resolved 26 April 2004
Resolution: Provided valid NOAA registration during 3rd Annual-Periodic inspection.
Lifesaving › Lifebuoys
Issued 28 October 2002 Resolved
Install lanyard and detachable clip IAW 180.70. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Unknown
Due 28 November 2002
Resolved 28 October 2002
Lifesaving
Issued 28 October 2002 Resolved
Provide first aid kit IAW 46 CFR 184.710. LEGACY COMPONENT DESC: First Aid Kit
Condition: Unknown
Due 28 November 2002
Resolved 26 April 2004
Resolution: Provided firs aid kit during 3rd Annual-Periodic inspection.
Construction/Loadline › Hull › Hull Plating
Issued 30 September 2002 Resolved
Repair damage to port hull at bow caused in collision
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2002
Resolved 7 October 2002
Construction/Loadline › Hull
Issued 7 May 2002 Resolved
Grind and renew delaminated areas of hull bottom from stem to 30 ft. back on the port hull and from stem to 20 ft. back on the starboard hull. LEGACY COMPONENT DESC: Hull Plating
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2002
Resolved 16 May 2002
Resolution: Vessel repaired delaminated areas on hull bottom.
Engineering › Steering Gear System
Issued 7 May 2002 Resolved
Renew bent rudder on port side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2002
Engineering › Gasoline Engine (propulsion)
Issued 7 May 2002 Resolved
Reweld broken outboard motor sled on port side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 7 May 2002 Resolved
Replace missing handrail fasteners throughout vessel. LEGACY COMPONENT DESC: Open Deck Space
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 7 May 2002 Resolved
Reweld broken handrail stanchion #4 on port side. LEGACY COMPONENT DESC: Open Deck Space
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2002
Resolved 16 May 2002
Resolution: Vessel operator repaired broken handrail stanchion #4 on port side.
Stability › Watertight Integrity
Issued 7 May 2002 Resolved
Replace broken airport most forward on the starboard side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2002
Stability › Watertight Integrity
Issued 7 May 2002 Resolved
Reinstall leaking port and starboard rudder posts in aft compartments.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2002
Resolved 16 May 2002
Resolution: Vessel operator repaired and reinstalled port and starboard rudder post.
Stability › Watertight Integrity
Issued 7 May 2002 Resolved
Replace discharge hoses on bilge pumps in the port and starboard aft compartments.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2002
Construction/Loadline › Structures › Superstructure
Issued 7 May 2002 Resolved
Have sail rigging inspected, especially the starboard backstay.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2002
Resolution: Sail rigging was inspected and the turnbuckle on the starboard backstay was replaced.
Navigation
Issued 30 November 2001 Resolved
Provide light for magnetic compass in accordance with 46 CFR 184.402.
Condition: Unknown
Due 8 December 2001
Resolved 7 December 2001
Resolution: Master procured new magnetic compass.
Fire Fighting
Issued 30 November 2001 Resolved
Provide proof of portable fire extinguisher servicing in accordance with 46CFR 176.810.
Condition: Unknown
Due 8 December 2001
Resolved 7 December 2001
Resolution: Master procured new fire extinguishers.
Engineering
Issued 30 November 2001 Resolved
Provide shutoff valve for fuel system in accordance with 46 CFR 182.455(b)(4).
Condition: Unknown
Due 15 December 2001
Resolved 7 December 2001
Resolution: Master installed quick disconnects for the fuel system.
Construction/Loadline
Issued 30 November 2001 Resolved
Provide dogs for port light covers for port lights in starboard head space and space forward of starboard head space in accordance with 46 CFR 179.350.
Condition: Unknown
Due 8 December 2001
Resolved 7 December 2001
Resolution: Master provided new port lights.
Documentation
Issued 30 November 2001 Resolved
Provide current training log, lifesaving maintenance record, and bridge log in accordance with 46 CFR 185.420, 185.702, and 185.520.
Condition: Unknown
Due 8 December 2001
Resolved 7 December 2001
Resolution: Master provided current training, lifesaving maintenance record and bridge log.
Stability › Watertight Integrity
Issued 30 November 2001 Resolved
Found port and starboard watertight hatches were not properly marked. Master marked hatches. LEGACY COMPONENT DESC: Watertight Hatch
Condition: Improper/Lack of Maintenance
Due 30 November 2001
Resolved 30 November 2001
Resolution: Master replaced retro reflective material on lifejackets.
Lifesaving › Lifejacket/PFD (Type III) › Retroreflective Material
Issued 30 November 2001 Resolved
Found 4 children's lifejackets with retro reflective material deteriorated. Master replaced retro reflective material on lifejackets.
Condition: Improper/Lack of Maintenance
Due 30 November 2001
Resolved 30 November 2001
Resolution: Master replaced retro reflective material on lifejackets.
Accommodation/Occupational Safety
Issued 11 June 2001 Resolved
Provide description of modification to vessel for approval.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Accommodation/Occupational Safety
Issued 11 June 2001 Resolved
Vessel is not to operate with passengers on forward trampoline prior to inspection by a Coast Guard Marine Inspector.
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Lifesaving
Issued 28 August 2000 Resolved
Provide proof of the hydrostatic release date for the 406MHz EPIRB in accordance with 46 CFR 180.64.
Condition: Unknown
Due 30 August 2000
Resolved 21 September 2000
Electrical
Issued 28 August 2000 Resolved
Remove dead end wires in starboard distribution panel in accordance with 46CFR 176.25-50.
Condition: Unknown
Due 30 August 2000
Resolved 21 September 2000
Lifesaving
Issued 28 August 2000 Resolved
Replace (2) cracked and damaged buoyant apparatuses with lifefloats in accordance with 46 CFR 182.200.
Condition: Unknown
Due 28 August 2000
Resolved 28 August 2000
Lifesaving
Issued 28 August 2000 Resolved
Mark location of lifejacket stowage on vessel in accordance with 46 CFR 180.78.
Condition: Unknown
Due 30 August 2000
Resolved 21 September 2000
Documentation
Issued 28 August 2000 Resolved
Provide proof of current FCC Safety Radio Certificate in accordance with 46CFR 184.502.
Condition: Unknown
Due 5 September 2000
Resolved 21 September 2000
Documentation
Issued 28 August 2000 Resolved
Provide proof of employee and supervisory drug training program in accordance with 46 CFR 40.
Condition: Unknown
Due 30 August 2000
Resolved 21 September 2000
Construction/Loadline
Issued 28 August 2000 Resolved
Repair/ replace the port and starboard aft hatch covers in accordance with 46 CFR 171.124.
Condition: Unknown
Due 30 August 2000
Resolved 21 September 2000
Documentation
Issued 2 September 1999 Resolved
Renew FCC Safety Certificate._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Documentation
Issued 8 September 1998 Resolved
Provide and document 60 minutes of drug/alcohol training for supervisors inaccordance with 46 CFR 16.401.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Lifesaving
Issued 8 September 1998 Resolved
Provide a category 1, 406 MHz EPIRB and install to automatically float freeand activate. Vessel route is restricted to within 3 miles from shore until EPIRB is provided.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Documentation
Issued 18 September 1996 Resolved
PROVE FULL COMPLIANCE WITH CHEMICAL TESTING PROGRAM REQUIREMENTS OF 46CFR16NO LATER THAN 02 OCT 96. THIS INCLUDES WRITTEN DRUG POLICY AND EMPLOYEE ASSISTANCE PROGRAM WITH EMPLOYEE ACKNOWLEDGEMENT, SUBMISSION OF ANNUAL MIS REPORTS, SUPERVISOR TRAINING AND LOGS.
Condition: Unknown
Due 18 September 1996
Resolved 18 September 1996
Documentation
Issued 18 September 1996 Resolved
PROVIDE DRUG TEST RESULTS FOR AT LEAST 50% OF CREW WITHIN PAST 12 MONTHS. CURRENTLY ONLY ONE OF SIX EMPLOYEES WAS TESTED WITHIN 12 MONTHS; AT LEAST TWO MORE ARE REQUIRED NO LATER THAN 25 SEP 96.
Condition: Unknown
Due 18 September 1996
Resolved 18 September 1996
Lifesaving
Issued 23 October 1995 Resolved
Renew life preserver location labels on seat boxes.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Electrical
Issued 23 October 1995 Resolved
Refasten green ground wire in starboard aft seat box._x001C_
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Lifesaving
Issued 23 October 1995 Resolved
Replace life ring buoy.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Construction/Loadline
Issued 23 October 1995 Resolved
Replace the bilge feet on both bilge lines.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Accommodation/Occupational Safety
Issued 23 October 1995 Resolved
Provide locking mechanism for MSD valve that is accessible to passengers sothat it may not be discharged.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Lifesaving
Issued 23 October 1995 Resolved
Provide a 100' painter for buoyant apparatus.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Lifesaving
Issued 23 October 1995 Resolved
Provide operational water light for buoyant apparatus.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Lifesaving
Issued 23 October 1995 Resolved
Replace line on life ring buoy.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Electrical
Issued 23 October 1995 Resolved
Provide light lens cover in starboard accommodation space.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Lifesaving
Issued 23 October 1995 Resolved
Restencil number of persons on buoyant apparatus.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Lifesaving
Issued 23 October 1995 Resolved
Provide three orange smoke flares.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Lifesaving
Issued 23 October 1995 Resolved
Perform routine maintenance on all life preservers-clean and replace retroreflective tape as necessary.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Accommodation/Occupational Safety
Issued 26 October 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 26 October 1994
Resolved 28 November 1994
Documentation
Issued 22 September 1994 Resolved
CHANGE NAME OF VESSEL ON CERTIFICATE OF DOCUMENTATION TO "NAHOKU II", OR CORRECT ALL LIFESAVING GEAR AND VESSEL'S MARKINGS TO MATCH CURRENT DOCUMENTED NAME "NAHOKU".
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Documentation
Issued 22 September 1994 Resolved
PROVIDE SAIL PLAN AND CALCULATIONS MEETING THE REQUIREMENTS OF 46 CFR 171.035 (b) FOR STABILITY.
Condition: Unknown
Due 5 January 1995
Resolved 5 January 1995
Construction/Loadline
Issued 29 August 1994 Resolved
PROPERLY INSTALL DECK RAILS IAW 46 CFR 177.35-1 AND MAKE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 5 January 1995
Resolved 5 January 1995
Construction/Loadline
Issued 29 August 1994 Resolved
PROPERLY INSTALL CAPTIVE CHAINS ON BOTH FORWARD HATCHES AND MAKE AVAILABLE FOR INSPECTION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 January 1995
Resolved 5 January 1995

Casualty record · 2

4 May 2006Routine · role: Involved in a Marine Casualty · 1 injured · activity 2644263
22 October 2020Routine · role: Involved in a Marine Casualty · activity 7105199
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

NAHOKU II (2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.