MAURY USCG vessel records
← All vessels

PACIFIC

Built
1993
Last inspected
24 September 2018
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 24 September 2018
…with no type recorded13
Operational controls None recorded without a removal date
Years with a record 26 calendar years (1993–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC4655
393698
Flag
UNITED STATES
Maury page id
psix-393698

Documentation record

Tonnage as PSIX records it5669 - Convention (Subpart B), Gross Ton
3739 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 71 inspections, each with its date, unit and type; 36 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 9 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 9

Inspection history · 71

24 September 2018 Load Line/Change of Employment
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6547715
6 November 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6347172
31 August 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5994368
10 August 2016 MTSA/ISPS Verification · MARPOL Annex VI Survey · MARPOL Annex I Examination · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5965660
12 February 2016 Internal Structural Exam · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5816137
10 December 2015 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5779758
31 August 2015 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5230957
11 September 2014 MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4983884
3 February 2014 Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4792989
2 February 2014 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4794111
17 December 2013 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4770570
17 December 2013 Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4771597
16 December 2013 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4770470
30 October 2013 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4744231
14 August 2013 Internal Structural Exam · Drydock Exam · MARPOL Annex VI Survey · MTSA Verification · Cargo Tank Internal · Deficiency Check · MARPOL Annex II Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4685070
4 October 2012 MARPOL Annex II Examination · MTSA Verification · MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4465507
14 October 2011 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4168028
7 October 2011 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4163472
1 September 2011 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4141827
26 July 2011 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4101904
7 July 2011 MARPOL Annex I Examination · COI Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4071870
16 June 2010 MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3766678
11 March 2010 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3694386
31 August 2009 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3578070
4 June 2009 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3495377
15 August 2008 Annual Inspection · Drydock Exam · MTSA Verification · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3302141
16 January 2008 In-Service Inspection · Damage Survey
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3130798
26 September 2007 MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3066928
19 September 2006 Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2787496
25 August 2006 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2759552
9 August 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2741568
10 July 2006 MTSA Verification · COI Inspection · MARPOL Annex I Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2691863
25 October 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2521564
25 October 2005 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2521633
28 July 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2443365
30 June 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2409358
29 June 2005 MTSA Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2406202
23 July 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2142072
19 July 2004 Periodic Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2132866
22 April 2004 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2050146
15 October 2003 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1923966
22 September 2003 Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1906133
26 October 2002 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1697764
27 September 2002 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1681243
3 September 2002 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1670199
31 July 2002 Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1654468
20 November 2001 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1077090
18 October 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1458001
16 July 2001 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1418952
18 March 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 500629
10 January 2001 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1057725
8 January 2001 MARPOL Annex II Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 825230
13 October 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 125004
16 September 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1053908
15 September 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1426464
24 March 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1441634
25 August 1999 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 779590
24 August 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 60157
16 July 1999 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1449211
8 September 1998 Hull Examination · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1466558
14 February 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1112064
18 August 1997 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1119675
6 August 1997 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1400614
15 January 1997 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1100211
28 October 1996 Re-Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1367946
8 September 1995 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1414508
27 December 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 119908
27 October 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 94106
13 October 1994 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1363115
21 December 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 153779
20 October 1993 Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1422290

Deficiency record · 36

Construction/Loadline › Hull › Hull Plating
Issued 12 February 2016 Resolved
Repair crack in #1 port void hull plate.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2016
Resolved 14 March 2016
Resolution: Vessel has completed required repairs and is fit to be placed back into service.
Construction/Loadline › Hull › Hull Plating
Issued 3 February 2014 Resolved
Vessel is restricted from loading further cargo until satisfactory repairs have been made to damage sustained to stbd fwd rake in collision. Discharge of current cargo to facility is authorized.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2014
Resolution: Recieved class report attesting to the satisfactory repairs of all damage.
Construction/Loadline › Hull › Hull Plating
Issued 17 December 2013 Resolved
Repair damage to watertight envelope IWO #3S void prior to loading cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 December 2013
Resolution: [name withheld] and [name withheld] attended vessel to complete air test on vessel. Completed satisfactory test at 1.5 psig on #3S void testing the weld bead with soapy water. Completed vacuum box test on #2S Void. All sat.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 14 August 2013 Resolved
Vessel must fix non-working deck lighting
Due 7 October 2013
Resolved 2 October 2013
Resolution: Recieved electrician report attesting to the working condition of the deck lights.
Documentation › Certificates/Documents › IAPP Certificate Supplement
Issued 14 August 2013 Resolved
Vessel does not have a Volatile Organic Compound (VOC) Management plan onboard IAW MARPOL Annex VI Reg. 15. Vessel prohibited from carrying crude oil internationally.
Due 14 January 2014
Resolved 22 November 2013
Resolution: Vessel provided MSC Approved VOC MGMT plan. Def cleared.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 August 2013 Resolved
Electrical installations in shelter shall be approved for Class I Division I enviornments, or vessel must permanently remove all openings within the hazardous zone. 46 CFR 111.105-3
Due 14 November 2013
Resolved 13 November 2013
Resolution: Inspected blank making space vaportight. Vessel will conduct perm. repair within the next 3 weeks.
Documentation › Logs/Records › Bunker Delivery Notes/Samples
Issued 4 October 2012 Resolved
Vessel does not have bunker delivery notes that contain sulfur content.
Action required: 705 - Other - as specified
Due 4 November 2012
Resolved 4 November 2012
Resolution: Received bunker delivery notes with sulfur content.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 4 October 2012 Resolved
Vessel must have a IAPP certificate prior to traveling foreign
Action required: 705 - Other - as specified
Due 4 November 2012
Resolved 4 November 2012
Resolution: an IAPP certificate has been generated and will be issued after signature.
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 4 October 2012 Resolved
Vessel does not have a loading manual onboard.
Action required: 705 - Other - as specified
Due 4 November 2012
Resolved 4 November 2012
Resolution: Received a copy of the approved loading manual with a statement from the company, demonstrating the manual is onboard.
Construction/Loadline › Hull › Double Hull
Issued 7 October 2011 Resolved
Make #1 port void space available for Coast Guard inspection once certified safe for entry by a marine chemist.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2011
Construction/Loadline › Hull › Double Hull
Issued 7 October 2011 Resolved
Make permanent repairs in the #1 Port void/double hull space IWO the #3P bottom long stiffener just aft of the fwd blkhd/transverse frame #6. Proceed to drydock to affect repairs after temp repairs are made.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2011
Resolution: Attended vessel, verified repairs, cleared deficiency.
Electrical › Electric Generation Source (service) › Generator
Issued 7 July 2011 Resolved
Prove proper operation of the over-speed device on the SSDG.
Due 4 August 2011
Resolved 26 July 2011
Resolution: Attended vsl at KMI Carteret NJ to witness proper operations of the SSDG over speed protection. Over speed protection works satisfactory.
Construction/Loadline › Hull › Hull Plating
Issued 4 June 2009 Resolved
Crop and renew deck plating above the #3 tank where there are 06 fractures present.
Action required: 705 - Other - as specified
Resolved 7 June 2009
Resolution: Croped and renewed a 18" X 160" insert above the #3 tank where the fractures were present, renewed 06 stiffners.
Construction/Loadline › Hull › Weld
Issued 4 June 2009 Resolved
Repair the 22 fractured welds that were called out along the forward perimeter of the barge.
Action required: 705 - Other - as specified
Resolved 7 June 2009
Resolution: Repaired the 22 fractured welds.
Construction/Loadline › Hull › Hull Plating
Issued 15 August 2008 Resolved
Complete repair of all damaged areas listed in the worklist provided by attending Inspector, PE, and ABS.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2008
Resolved 28 August 2008
Lifesaving › Lifebuoys › Stowage
Issued 10 July 2006 Resolved
Properly mount ring buoys on vessel IAW 46 CFR 199.640 (i) (2). Vessel is required to carry two ring buoys, one at each end of vessel. Ring buoys are to be mounted and available.
Due 10 August 2006
Resolved 9 August 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 July 2006 Resolved
Prove proper operation of starboard navigation light. Corrected on the spot 07/10/06.
Due 10 August 2006
Resolved 10 July 2006
Electrical › Electric Supply System (service) › Cable
Issued 30 June 2005 Resolved
Renew all prime mover diesel engine starting cables with approved marine grade conductors.
Due 1 August 2005
Resolved 28 July 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 June 2005 Resolved
Renew corroded electrical cable conduits on main deck as indicated no later than next drydocking or September 2006.
Due 30 September 2006
Resolved 19 September 2006
Resolution: All new electrical cable conduit was renewed.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 30 June 2005 Resolved
Provide permanent repair to vapor control system piping in way of dresser coupling near cargo transfer manifold amidships.
Due 30 September 2006
Resolved 1 September 2006
Resolution: Had spoken to vsl rep and allowed DF to be taken care of prior to leaving dry-dock. Pipe renewed and vapor tested, sat.
Construction/Loadline › Markings › Load Line Mark
Issued 19 July 2004 Resolved
Paint deck reference line in accordance to vessel's present valid Load Line Certificate and the permanent markings on hull. Ref: 46CFR42.13-20
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 August 2004
Resolved 23 July 2004
Resolution: Painted sat.
Pollution Prevention/Response › Prevention Equipment › Emergency Control Systems (tank barges)
Issued 19 July 2004 Resolved
Have a qualified technician from Bergan Tank Control service the cargo vapor recovery gauging system. Check alarm system and mechanical floats (the loss of power alarm not working, sticks for testing high & high-high alarms are sticking.) Ref: 46CFR39.20-3
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 August 2004
Resolved 23 July 2004
Resolution: All alarms tested sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 19 July 2004 Resolved
Calibrate discharge pressure gauges of cargo pumps.
Action required: 705 - Other - as specified
Due 19 August 2004
Resolved 23 July 2004
Resolution: Calibrated sat.
Construction/Loadline › Hull
Issued 27 September 2002 Resolved
FIND AND REPAIR FRACTURE IN #1 PORT CARGO TANK IN WAY OF #1 PORT DOUBLE HULL VOID PRIOR TO CARRYING CARGO IN #1 PORT CARGO TANK. LEGACY COMPONENT DESC: Double Hull
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 October 2002
Resolved 26 October 2002
Resolution: PLATE FX FOUND, INSERTED AND TESTED.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 31 July 2002 Resolved
Repair vapor leaks to gaskets in 2 P/S and 3 P/S sight glass, bolts on 5 P/S ullage tops, and 3 P tank access.
Due 31 July 2002
Resolved 31 July 2002
Documentation › Certificates/Documents
Issued 31 July 2002 Resolved
Provide annual SOPEP review letter. Letter was not available during inspection.
Due 31 August 2002
Resolved 30 August 2002
Resolution: Received copy of review letter.
Deck/Cargo
Issued 31 July 2002 Resolved
Properly label two deck cranes with safe working load. Both cranes were new and missing information.
Due 31 July 2002
Resolved 31 July 2002
Electrical › Electrical Distribution System (service)
Issued 31 July 2002 Resolved
Properly repair wire jackets to high level alarms at tanks 2S, 4P, 5P/S. LEGACY COMPONENT DESC: Wiring
Due 31 August 2002
Resolved 30 August 2002
Resolution: Received copy of purchase orders and signed statement from vessel rep stating work was completed on 8/17/2002.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 July 2002 Resolved
Prove proper operation of flashing light. Light did not work.
Due 31 July 2002
Resolved 31 July 2002
Resolution: Replaced battery.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 31 July 2002 Resolved
Properly repair secondary emergency shut-down to starboard prime mover. Secondary system did not properly release when activated.
Due 7 August 2002
Resolved 31 July 2002
Construction/Loadline
Issued 15 September 2000 Resolved
REPLACE GASKET ON #3 STBD WING VOID HATCH.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Navigation
Issued 15 September 2000 Resolved
MAKE PERM. REPAIRS TO INLAND AMBER FLASHING LT.
Condition: Unknown
Due 16 September 2000
Resolved 20 September 2000
Deck/Cargo
Issued 15 September 2000 Resolved
MAKE VCS READY FOR INSPECTION IAW D8 POLICY LTR.
Condition: Unknown
Due 15 September 2000
Resolved 20 September 2000
Deck/Cargo
Issued 15 September 2000 Resolved
REPAIR AND TEST HI LEVEL ALARMS PRIOR TO ONLOADING NEXT CARGO. (NO AUDIBLE ALARMS)
Condition: Unknown
Due 16 September 2000
Resolved 20 September 2000
Construction/Loadline
Issued 15 September 2000 Resolved
REPAINT STBD FWD DRAFT MARKS.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Documentation
Issued 28 October 1996 Resolved
Provide U.S. Coast Guard (G-MSC) approved plans that include the two connectors for barge overflow control system currently installed on the vessel.
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.