Inspection history · 65
19 April 2024
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7898400
30 September 2022
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7570751
16 September 2022
Type not recorded
No type recorded · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7560618
25 January 2022
Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7385497
12 June 2021
Deficiency Check · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7223038
17 March 2021
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7170855
4 December 2020
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7137050
9 May 2020
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7002528
27 September 2019
Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6825746
27 September 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6830022
21 August 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6790800
4 January 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6332284
11 January 2017
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6069622
14 October 2016
Industry Initiated Exam · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6025203
7 September 2016
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5994290
31 August 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5994368
16 December 2013
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4770470
29 October 2013
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4743185
17 September 2013
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4718504
16 February 2012
Administration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4245454
18 May 2010
Administration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3741012
3 August 2009
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3554213
2 August 2009
Administration
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3553868
20 February 2009
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3432849
16 March 2008
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3166390
2 March 2007
Type not recorded
No type recorded · Station Mayport · USCG Southeast District (CGD-SE) · Activity 2880998
28 February 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2879564
4 January 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2876528
27 October 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3030716
27 October 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3030835
19 October 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2808335
2 October 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2791719
2 October 2006
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2794121
2 October 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2794935
1 May 2006
Administrative Inspection · Uninspected Other · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2637798
1 May 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2638773
10 April 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2621381
4 April 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2620858
1 April 2006
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2614214
31 March 2006
Security Plan Review - ASP · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2614216
11 December 2005
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2557155
26 August 2005
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2475132
16 June 2005
MTSA Verification · Uninspected Other
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2474559
15 June 2005
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2584604
22 March 2005
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2318379
14 August 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2295131
28 June 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2303666
29 December 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1975103
12 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1980814
8 March 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1754670
22 January 2003
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2392255
5 July 2002
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1641325
4 June 1999
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1360922
6 October 1997
MARPOL Annex V Examination · Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1108683
23 July 1997
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 781360
22 July 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 44093
5 October 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1416378
4 April 1996
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 389753
27 September 1995
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 755434
26 September 1995
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 205853
16 May 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 182740
26 October 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 141744
17 June 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 179839
4 February 1993
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 536583
30 September 1991
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 646820
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 September 2022
Resolved
The vessel owner and operator must comply with the terms of an order from the Captain of the Port under this authority. (CAPTAIN OF THE PORT No. 7560618). The towing vessel THOMAS DANN and barge SOMERSET did not depart after the setting of Hurricane Port Readiness Condition YANKEE and was not approved to remain in Port.
Action required: 10 - Deficiency Rectified
Resolved 21 September 2022
Resolution: Letter of Warning issued.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 June 2021
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following:All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids. Excessive oil accumulation in bilge must be removed.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 June 2021
Resolved 15 June 2021
Resolution: Oil cleaned from bilge
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 June 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Clean all oil accumulation.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 June 2021
Resolved 15 June 2021
Resolution: Oil cleaned from engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 12 June 2021
Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. Renew exhaust lagging on both main propulsion diesel engines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2021
Resolved 6 July 2021
Resolution: Lagging renewed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 September 2019
Resolved
Provide damage asessement and repair proposal to USCG from damage sustained from casualty on 27SEP2019. All repairs to be completed to the satisfaction of attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 2 December 2019
Engineering › Fuel Oil Service System › Valve
Issued 16 June 2005
Resolved
REMOTE OPERATED FUEL SHUTOFF VALVES INOP.
Due 30 June 2005
Resolved 28 June 2005