Inspection history · 140
17 April 2008
Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3185997
13 February 2008
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3146759
4 February 2008
Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3141311
3 May 2007
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2921576
20 April 2007
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2911507
4 January 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2876528
2 January 2007
MTSA Verification · MARPOL Annex I Examination · COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2849072
1 May 2006
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2637917
15 February 2006
MARPOL Annex I Examination · Cargo Tank Internal · Periodic Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2585437
14 July 2005
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2426851
15 June 2005
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2393377
15 June 2005
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2584604
8 April 2005
Annual Inspection · MTSA Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2321262
22 March 2005
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2318379
13 January 2005
Damage Survey
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2274704
26 October 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2228561
14 August 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2295131
28 June 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2303666
11 May 2004
Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2064889
17 February 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2016377
12 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1980828
16 October 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1929672
20 June 2003
Cargo Tank Internal · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2001985
21 March 2003
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1759116
8 March 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1754670
28 February 2003
Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1753951
25 January 2002
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1481446
23 January 2002
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1480797
10 January 2002
COI Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1477313
16 November 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 149344
8 April 2001
Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 52176
8 April 2001
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1063099
28 March 2001
Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1430979
2 January 2001
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1056437
25 November 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 126422
22 February 2000
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 816275
14 January 2000
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1467184
8 December 1999
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 812798
9 November 1999
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 808077
25 October 1999
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 792957
14 May 1999
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 531813
22 April 1999
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 790862
12 February 1999
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 794098
2 February 1999
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1470494
31 May 1998
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 792366
19 February 1998
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1116978
20 January 1998
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1443959
4 June 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 520283
28 March 1997
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1104269
4 February 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 767387
5 January 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 200414
27 October 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 494158
30 September 1996
Damage Survey · Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1147675
21 September 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 45290
21 September 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 188738
6 May 1996
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 462633
26 March 1996
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1078554
2 February 1996
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1182745
4 December 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 873596
4 August 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 462460
30 May 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 534484
13 April 1995
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1162227
8 March 1995
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 860319
4 March 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 467805
2 February 1995
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1146570
12 August 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 523094
6 April 1994
Examination of Repairs
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1412620
5 April 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 153694
5 April 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1169226
4 February 1994
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1164075
6 November 1993
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 442881
27 May 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 836510
11 May 1993
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 524459
4 March 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 842136
9 September 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 501943
24 August 1992
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 488789
26 February 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 489516
12 February 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955731
7 August 1991
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 533964
12 February 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1231741
31 January 1991
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 492264
18 January 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1209415
20 December 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1229100
28 September 1990
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1231316
25 September 1990
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 339539
23 April 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 909460
22 April 1990
Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1228339
4 April 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 521849
26 March 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1212296
21 February 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 900300
15 February 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1212125
14 February 1990
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 911659
14 February 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1292965
30 October 1989
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1027035
30 August 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1204439
24 August 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 477720
11 May 1989
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 494212
3 March 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1197985
24 February 1989
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 891538
9 February 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1034639
8 February 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 444505
10 January 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 888383
21 November 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1207296
27 October 1988
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 478512
2 September 1988
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1347926
8 August 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1037478
28 June 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1206570
13 May 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 893597
13 May 1988
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 893600
22 March 1988
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1030526
26 February 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1334155
18 February 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1330190
6 November 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1021837
7 October 1987
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1012228
2 October 1987
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1012516
3 April 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 529807
27 March 1987
Examination of Repairs · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1020268
19 March 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 477430
13 March 1987
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1013973
7 March 1987
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1316378
8 December 1986
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 494878
8 December 1986
Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1023001
13 November 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1016336
13 November 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1016338
27 October 1986
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1320230
23 October 1986
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1012761
25 September 1986
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1313028
1 June 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1015123
26 February 1986
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 986829
18 January 1986
Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1001421
18 November 1985
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1301131
10 July 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 494188
14 June 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1285985
23 April 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 981606
20 December 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 977121
3 December 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1284707
15 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964978
22 April 1983
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 963516
15 May 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1274867
29 April 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279167
Deck/Cargo › Cargo Stowage › General
Issued 13 February 2008
Resolved
C/R holed bottom #3 port cargo tank as marked, minimum 18" x 18" back to good metal.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2008
Resolution: Repair completed.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 13 February 2008
Resolved
No welding to new inserts are to be welded until new marine chemist cert provided permission to complete the same. Original certificate does not allow wedling within 2 feet of centerline.
Action required: 705 - Other - as specified
Resolved 19 February 2008
Resolution: Tank was recertified to allow welding near centerline.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 4 February 2008
Resolved
Provide accurate MFG data for air receiver.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 March 2008
Resolved 6 February 2008
Resolution: Data provided from construction plans. Conducted pressure test to verify proper operation of new relief valve.
Deck/Cargo › Cargo Heating › General
Issued 4 February 2008
Resolved
Make port Thermal Fluid heater ready for internal exam.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 March 2008
Resolved 6 February 2008
Resolution: Internal inspection conducted.
Engineering › Generator (propulsion/auxiliary-electric) › Breaker Circuitry
Issued 4 February 2008
Resolved
Prove operational readiness of ship's generators.
Action required: 705 - Other - as specified
Due 4 March 2008
Resolved 6 February 2008
Resolution: All 3 generators repaired and tested, sat.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 2 January 2007
Resolved
Breaker for port Thermal Fluid Heater blower motor will not reset.
Condition: Unknown
Due 5 January 2007
Resolved 5 January 2007
Resolution: Replaced circuit breaker on port side Thermal Fluid Heater blower motor.
Deck/Cargo › Cargo Heating › General
Issued 2 January 2007
Resolved
Stbd Thermal Fluid Heater low flow switch failed to activate safety shutdown.
Condition: Unknown
Due 5 January 2007
Resolved 5 January 2007
Resolution: Replaced low flow switch on stbd Thermal Fluid Heater, all safety shutdown tested properly.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 13 January 2005
Resolved
Provide onboard a new anchor for one that is missing from earlisr allision at AMA Anchorage Mississippi River. Anchoar cable also to be replaced.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 13 February 2005
Resolved 14 January 2005
Construction/Loadline › Hull › Hull Plating
Issued 13 January 2005
Resolved
Provide ABS Class report for the MINOR damage to the port bow section caused by allision on the 13th of JAN05.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 13 February 2005
Resolved 14 January 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 March 2003
Resolved
Reattach hand rails through out barge.
Due 31 May 2003
Resolved 21 March 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 18 March 2003
Resolved
Repack remote valve deck seals.
Due 31 May 2003
Resolved 20 June 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 18 March 2003
Resolved
Install guard over torating capstan drive shaft. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 31 May 2003
Resolved 20 June 2003
Engineering › Fuel Oil Service System
Issued 18 March 2003
Resolved
Make permanent repairs to holed (soft patched) fuel tank vent. LEGACY COMPONENT DESC: Tank
Due 31 May 2003
Resolved 20 June 2003
Pollution Prevention/Response › Prevention Equipment
Issued 18 March 2003
Resolved
Renew tank level indicator (gauging sticks) #5P cargo tank (free-up all gauging sticks). LEGACY COMPONENT DESC: Overfill Devices
Due 31 May 2003
Resolved 20 June 2003
Engineering › Fuel Oil Service System
Issued 18 March 2003
Resolved
Make permanent repairs to holed (soft patched) fuel fill piping. LEGACY COMPONENT DESC: Piping
Due 31 May 2003
Resolved 20 June 2003
Construction/Loadline › Structures
Issued 18 March 2003
Resolved
Renew and chalk test gasket, port aft void hatch. LEGACY COMPONENT DESC: Door
Due 31 May 2003
Resolved 20 June 2003
Engineering › Lubricating Oil Service System
Issued 18 March 2003
Resolved
Make permanent repairs to port lube vent/holed. LEGACY COMPONENT DESC: Piping
Due 31 May 2003
Resolved 20 June 2003
Deck/Cargo › Mooring/Anchoring
Issued 18 March 2003
Resolved
Prove proper operation of port stern capstan. Secure power to open J-box. LEGACY COMPONENT DESC: Capstan
Due 31 May 2003
Resolved 20 June 2003
Electrical › Electric Generation Source (service)
Issued 18 March 2003
Resolved
Overspeed trips on both ship service generators did not function. Prove proper operation to attending CG Marine Inspector. LEGACY COMPONENT DESC: Generator
Due 31 May 2003
Resolved 20 June 2003
Electrical › Electric Generation Source (service)
Issued 18 March 2003
Resolved
Repair exhaust lagging IWO E/R overhead for common exhaust piping from ships service generators.
Due 31 May 2003
Resolved 20 June 2003
Engineering › Fuel Oil Service System
Issued 18 March 2003
Resolved
Make permanent repairs to soft patched tube for thermal fluid heater fuel tank shut off valve. LEGACY COMPONENT DESC: Piping
Due 31 May 2003
Resolved 20 June 2003
Deck/Cargo › Holds/Tanks
Issued 18 March 2003
Resolved
Provide documentation showing that cargo relief valves open at pressure (or below) which it is set to open. LEGACY COMPONENT DESC: Valve, Pressure Vacuum Relief
Due 31 May 2003
Resolved 20 June 2003
Pollution Prevention/Response › Prevention Equipment
Issued 18 March 2003
Resolved
Provide standard discharge connection IAW 33 CFR 155.430. LEGACY COMPONENT DESC: Standard Discharge Connection
Due 31 May 2003
Resolved 20 June 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 March 2003
Resolved
Replace expired meds in first aid kit.
Due 31 May 2003
Resolved 21 March 2003
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 March 2003
Resolved
Replace line on stbd. aft lifering with black polyprop. line.
Due 31 May 2003
Resolved 21 March 2003
Construction/Loadline › Structures › Door
Issued 18 March 2003
Resolved
Free up / lubricate and adjust all water tight door hinges and dogs.
Due 31 May 2003
Resolved 21 March 2003
Deck/Cargo › Holds/Tanks › Hatch
Issued 18 March 2003
Resolved
Free up lubricate and adjust all ullage openings.
Due 31 May 2003
Resolved 21 March 2003
Electrical › Lighting (service) › Lighting Fixture
Issued 18 March 2003
Resolved
Provide globe cover for lighting between ship service generators.
Due 31 May 2003
Resolved 21 March 2003
Deck/Cargo › Cargo Heating
Issued 18 March 2003
Resolved
Permanently mount exhaust riser for port side thermal fluid heater. Make permanent repairs to exhaust stack (soft patched) port thermal fluid heater.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2003
Deck/Cargo › Cargo Heating
Issued 18 March 2003
Resolved
Prove proper operation and shutdowns of both thermal fluid heaters. Remove dead end wiring, repair jury rigging of wiring, and remove all jumpers in control circuit panels.
Due 31 May 2003
Resolved 21 March 2003
Engineering › Compressed Air System (control) › Valve
Issued 18 March 2003
Resolved
Prove proper operation of relief valve for compressor pressure vessel.
Due 31 May 2003
Resolved 21 March 2003
Engineering › Pressure Vessel
Issued 28 February 2003
Resolved
Prior to operating thermal fluid heater, conduct a hydrostatic test of the newly installed coils. LEGACY COMPONENT DESC: Thermal Fluid Heater
Action required: 705 - Other - as specified
Due 3 March 2003
Resolved 3 March 2003
Resolution: Hydrostatic test conducted at 350 psi. Test satisfactory.
Deck/Cargo › Cargo Heating
Issued 10 January 2002
Resolved
Replace fire gun cone and refractory assembly on STBD TFH. LEGACY COMPONENT DESC: Fire Gun Assembly
Condition: Unknown
Due 10 February 2002
Resolved 25 January 2002
Resolution: new assembly installed.
Lifesaving › Lifebuoys
Issued 10 January 2002
Resolved
Replace lifebuoy line with dark or U/V resistant line. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Due 10 February 2002
Resolved 25 January 2002
Lifesaving › Lifebuoys
Issued 10 January 2002
Resolved
Replace lifebuoy on STBD and aft sides of deck house.
Condition: Improper/Lack of Maintenance
Due 10 February 2002
Resolved 25 January 2002
Deck/Cargo › Cargo Stowage
Issued 10 January 2002
Resolved
Replace flame screens on gaging ports 1S, 2S, 3S, 1P, 2P and 5P. LEGACY COMPONENT DESC: Gaging Ports Flame Screens
Condition: Improper/Lack of Maintenance
Due 10 February 2002
Resolved 25 January 2002
Deck/Cargo › Cargo Stowage
Issued 10 January 2002
Resolved
Open P/V's and make ready for inspection. LEGACY COMPONENT DESC: P/V valves
Due 10 February 2002
Resolved 25 January 2002
Deck/Cargo › Cargo Stowage
Issued 10 January 2002
Resolved
Mark rising stick indicators as required by the Regs. LEGACY COMPONENT DESC: Rising Stick Indicators
Condition: Improper Installation
Due 10 February 2002
Resolved 25 January 2002
Engineering › Thrusters
Issued 10 January 2002
Resolved
Replace/calibrate tachometer on bow thruster engine. LEGACY COMPONENT DESC: Tachometer
Condition: Improper/Lack of Maintenance
Due 10 February 2002
Resolved 25 January 2002
Resolution: Stewart Stephenson replaced in kind.
Electrical › Electric Supply System (service)
Issued 10 January 2002
Resolved
Remove deadend wires by anchor windless and STBD aft capstan.
Condition: Improper/Lack of Maintenance
Due 10 February 2002
Resolved 25 January 2002
Resolution: installed new assembly
Lifesaving › Lifebuoys
Issued 10 January 2002
Resolved
Replace STBD aft lifebuoy light bracket. LEGACY COMPONENT DESC: Stowage
Condition: Improper Installation
Due 10 February 2002
Resolved 25 January 2002
Deck/Cargo › Cargo Transfer (solid)
Issued 10 January 2002
Resolved
Replace missing exhaust insulation on port cargo engine. LEGACY COMPONENT DESC: Exhaust Insulation
Condition: Improper/Lack of Maintenance
Due 10 February 2002
Resolved 25 January 2002
Deck/Cargo › Cargo Transfer (solid)
Issued 10 January 2002
Resolved
Demonstrate overspeed trip on port cargo engine. LEGACY COMPONENT DESC: Cargo Engine
Condition: Improper/Lack of Maintenance
Due 10 February 2002
Resolved 25 January 2002
Resolution: third party report
Deck/Cargo › Cargo Heating
Issued 10 January 2002
Resolved
Demonstrate excess pressure switches on both TFHs. LEGACY COMPONENT DESC: Thermal Fluid Heater
Condition: Unknown
Due 10 February 2002
Resolved 25 January 2002
Resolution: operationally tested
Engineering
Issued 8 April 2001
Resolved
PUMP SEAL FAILED ON PORT AFT CARGO TRANSFER PUMP RESULTING IN A #6 SPILL.
Condition: Unknown
Due 8 April 2001
Resolved 8 April 2001
Electrical
Issued 28 March 2001
Resolved
Determine ground detection indicator on electrical switchboard to be burnedbulb or ground.
Condition: Unknown
Due 3 April 2001
Resolved 11 April 2001
Lifesaving
Issued 28 March 2001
Resolved
Equip port aft life buoy with line.
Condition: Unknown
Due 3 April 2001
Resolved 11 April 2001
Lifesaving
Issued 28 March 2001
Resolved
Replenish 4 parachute rocket flares. Atotal of 8 were onboard.
Condition: Unknown
Due 3 April 2001
Resolved 11 April 2001
Electrical
Issued 28 March 2001
Resolved
Place guard to outboard main generator electical junction box.
Condition: Unknown
Due 3 April 2001
Resolved 11 April 2001
Deck/Cargo
Issued 28 March 2001
Resolved
Install exhaust vent guards on port cargo pump, main generator exhaust, andhand guards on bow thruster.
Condition: Unknown
Due 3 April 2001
Resolved 11 April 2001
Electrical
Issued 28 March 2001
Resolved
Install rubber floor matting in front of electrical switchboard.
Condition: Unknown
Due 3 April 2001
Resolved 11 April 2001
Fire Fighting
Issued 28 March 2001
Resolved
Install appropriate length of hose to fwd B-V deck extinguisher to reach #1P/S cargo tank openings.
Condition: Unknown
Due 3 April 2001
Resolved 11 April 2001
Deck/Cargo
Issued 28 March 2001
Resolved
Place flange covers and bolts to cargo hoses.
Condition: Unknown
Due 3 April 2001
Resolved 11 April 2001
Construction/Loadline
Issued 14 January 2000
Resolved
On the port side, side shell, re-paint the loadline mark in contrasting color.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Engineering
Issued 14 January 2000
Resolved
Make thermal fluid heaters available for internal inspection.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Deck/Cargo
Issued 14 January 2000
Resolved
Provide a copy of Gulf Marine Design, Inc. Drawing No. 1028-T5, Revision 1,cargo piping; shematic; deadweight scale & loadline; and discharge procedures on board vessel.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Construction/Loadline
Issued 14 January 2000
Resolved
Provide ABS Class Report attesting to the structural integrity of inset port side, forward (at bow, below anchor line) & inset port side, midships,below the manifold.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Deck/Cargo
Issued 14 January 2000
Resolved
Test the transfer system relief valves & the tranfer pipe system. Provide ABS report attesting to these tests & provide testing log on board vessel.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Lifesaving
Issued 14 January 2000
Resolved
Replace forward lifebuoy.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Lifesaving
Issued 22 April 1999
Resolved
PROVE PROPER OPERATION OF BOW THRUSTER OVERSPEED.
Condition: Unknown
Due 22 April 1999
Resolved 22 April 1999
Electrical
Issued 2 February 1999
Resolved
PROVE PROPER OPERATION OF SHIP SERVICE GENERATOR OVERSPEEDS.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Deck/Cargo
Issued 2 February 1999
Resolved
PROVE PROPER OPERATION OF OVERSPEEDS ON BOTH CARGO PUMP ENGINES AND BOW THRUSTER.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Electrical
Issued 2 February 1999
Resolved
PROVE GROUND FAULT INDICATOR BREAKERS (WHITE IN COLOR) IN MACHINERY SPACE DISTRIBUTION PANELS ARE UL APPROVED AND OR IAW 46 CFR SUBCHAPTER "J".
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Documentation
Issued 2 February 1999
Resolved
PROVIDE PROOF THAT LOADING CALCULATIONS ON LOADLINES AND COI REFLECT SAME INFORMATION (DRAWING NO. 1025-T5 REV 1, DTD 07OCT80) VS (NO. 1028-T5 REV2, DTD 31JUL87). PROVIDE CORRECT CALCULATIONS ON BARGE FOR REVIEW. PROVIDE PROOF OF VRP/SOPEP CORRECTED WITH CURRENT CALCULATIONS.
Condition: Unknown
Due 10 February 1999
Resolved 17 February 1999
Lifesaving
Issued 2 February 1999
Resolved
PROVIDED PROPER STORAGE FOR FLAMMABLES OR REMOVE FROM VESSEL.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Deck/Cargo
Issued 20 January 1998
Resolved
At next drydock, prove operation of #3, #4 port and #2 starboard liquid level gauging sticks.
Condition: Unknown
Due 20 January 1998
Resolved 20 January 1998
Electrical
Issued 20 January 1998
Resolved
No later than 20 February 1998, provide light covers for all exposed lightsin thermal fluid heater room and cargo pump spaces.
Condition: Unknown
Due 20 January 1998
Resolved 20 January 1998
Deck/Cargo
Issued 20 January 1998
Resolved
At next drydock, open both thermal fluid heaters and make combustion chamber ready for inspection.
Condition: Unknown
Due 20 January 1998
Resolved 20 January 1998
Electrical
Issued 28 March 1997
Resolved
PROVE PROPER OPERATION OF L/O ALARMS AND OVERSPEEDS ON #1 & 2 SSDG'S_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Electrical
Issued 28 March 1997
Resolved
REPLACE #1,2 & 3 SSDG PRIME MOVER TACHOMETERS._x001C_
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Construction/Loadline
Issued 30 September 1996
Resolved
LOCATE & EFFECT TEMPORARY REPAIR TO LEAK IN #5 STBD CARGO TANK PRIOR TO CONDUCTING TRANSFER OPERATIONS. AFTER COMPLETE DISCHARGE OF CARGO, CLEAN & GAS FREE APPROPRIATE TANKS & CONDUCT PERMANENT REPAIRS.
Condition: Unknown
Due 30 September 1996
Resolved 7 October 1996
Electrical
Issued 2 February 1996
Resolved
PROVE PROPER OPERATION OF ALL INDICATOR LIGHTS & METERS ON MAIN SWITCHBOARD.
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Electrical
Issued 2 February 1996
Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIPS AND LOW LUBE OIL PRESSURE SHUTDOWNS ON #1 & #2 GENERATORS.
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Electrical
Issued 2 February 1996
Resolved
LABEL ALL BREAKERS ON POWER PANEL IN ENGINE ROOM.
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Electrical
Issued 2 February 1996
Resolved
LABEL BREAKER FOR ENGINE ROOM LIGHTS ON MAIN SWITCHBOARD.
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Unknown
Issued 2 February 1996
Resolved
CLEAN SCALE FROM BOTTOM OF AIR RECEIVER IN ENGINE ROOM
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Lifesaving
Issued 2 February 1996
Resolved
REMOVE ALL PORTABLE ELECTRIC HEATERS FROM ACCOMODATION AND MACHINERY SPACES.
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Construction/Loadline
Issued 13 April 1995
Resolved
REPAIR EMERGENCY EXIT IN GALLEY.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Deck/Cargo
Issued 13 April 1995
Resolved
STENCIL REQ INFORMATION ON CARGO PIPING AND PROVIDE HYDRO TEST DATE. STENCIL (1) HYDRO TEST DATE (2) MAWP.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Construction/Loadline
Issued 2 February 1995
Resolved
REPAIR EMERGENCY EXIT IN GALLEY.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Construction/Loadline
Issued 2 February 1995
Resolved
STENCIL REQ INFORMATION ON CARGO PIPING AND PROVIDE HYDRO TEST DATE.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Fire Fighting
Issued 12 February 1991
Resolved
RECHARGE SCBA FOR BARGES EMERGENCY SUIT
Condition: Unknown
Due 12 February 1991
Resolved 12 February 1991
Deck/Cargo
Issued 20 December 1990
Resolved
PROVIDE PROOF OR IN PRESENCE OF MARINE INSPECTOR HYDROSTATICALLY TEST TO 150 PERCENT OF MAXIMUM ACTUAL WORKING PRESSURE ALL CARGO PIPING.
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Accommodation/Occupational Safety
Issued 20 December 1990
Resolved
PROVIDE PLANS OF STRUCTURAL AND ELECTRICAL REVISIONS TO GALLEY FOR REVIEW_x001C_ TO MARINE INSPECTION OFFICE NEW YORK.
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Construction/Loadline
Issued 23 April 1990
Resolved
REPAIR DAMAGED AREA LOCATED IN AFT PORT QUARTER
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Construction/Loadline
Issued 22 April 1990
Resolved
MAKE PERMANENT REPAIRS TO THE PORT AFTER FUEL TANK PRIOR TO THE CARRIAGE OR CARGO AND IN NO CASE LATER THAN 27APR90. A TWO FOOT CRACK IS VISIBLE APPROX. 4 FEET BELOW THE MAIN DECK. AN INTERNAL INSPECTION NOT DONE BECAUSE TANK WAS NOT GAS FREED.
Condition: Unknown
Due 22 April 1990
Resolved 22 April 1990
Construction/Loadline
Issued 21 February 1990
Resolved
VESSEL MUST MAKE AVAILABLE FOR INSPECTION CARGO TANK INTENALS NO LATER THAN15MAR90.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Construction/Loadline
Issued 15 February 1990
Resolved
VESSEL REPRESENTATIVE MUST PROVIDE DOCUMENTATION NO LATER THAN 21FEB90 INCLUSIVE VERIFYING CARGOES CARRIED FOR THE PAST YEAR FOR CONSIDERATION OF A 30 DAY EXTENSION OF CARGO TANK INTERNALS.
Condition: Unknown
Due 15 February 1990
Resolved 15 February 1990
Construction/Loadline
Issued 15 February 1990
Resolved
IF DOCUMENTATION OF CARGOES FOR PAST YEAR ARE NOT RECEIVED AND ACCEPTABLY EVALUATED, CARGO TANK INTERNAL EXAMINATION MUST BE COMPLETED NO LATER THAN 01MAR90.
Condition: Unknown
Due 15 February 1990
Resolved 15 February 1990
Documentation
Issued 15 February 1990
Resolved
VESSEL REPRESENTATIVE MUST PROVIDE DOCUMENTATION VERIFYING COMPLETION OF SATISFACTORY MID PERIOD INSPECTION BETWEEN 18DEC88 AND 18APR89 TO MIO NY NLT 30 DAYS.
Condition: Unknown
Due 15 February 1990
Resolved 15 February 1990
Engineering
Issued 14 February 1990
Resolved
INSTALL REMOTE EMERGENCY SHUTDOWNS FOR BOTH THERMAL FLUID HEATER AND MACHINERY SPACE VENTILATION FANS.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Engineering
Issued 14 February 1990
Resolved
MAKE AVAILABLE FOR INSPECTION. FIRE BOXES OF BOTH THERMAL FLUID HEATERS.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Accommodation/Occupational Safety
Issued 21 November 1988
Resolved
PROVIDE THIRD BUNK IN SLEEPING ACCOMMODATIONS.
Condition: Unknown
Due 21 November 1988
Resolved 21 November 1988
Fire Fighting
Issued 21 November 1988
Resolved
PROVIDE USCG APPROVED SELF-CONTAINED BREATHING APPARATUS FOR THE EMERGENCY OUTFIT.
Condition: Unknown
Due 21 November 1988
Resolved 21 November 1988
Fire Fighting
Issued 21 November 1988
Resolved
PROVIDE ADDITIONAL DISCHARGE HOSE FOR SEMI-PORTABLE B-V FIRE EXTINGUISHER SO THE ENTIRE CARGO DECK IS PROTECTED.
Condition: Unknown
Due 21 November 1988
Resolved 21 November 1988
Construction/Loadline
Issued 21 November 1988
Resolved
PROVIDE SECOND MEANS OF ESCAPE OUT OF SLEEPING ACCOMMODATIONS.
Condition: Unknown
Due 21 November 1988
Resolved 21 November 1988
Electrical
Issued 18 February 1988
Resolved
DEMONSTRATE PROPER OPERATION OF BOTH S/S DIESEL GENERATORS, INCLUDING OVERSPEED AND LOW LUBE OIL PRESSURE TRIPS.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Documentation
Issued 18 February 1988
Resolved
UPDATE OWNER'S ADDRESS ON VESSEL'S DOCUMENTS.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Unknown
Issued 18 February 1988
Resolved
COMPLY WITH CG 835 #D-1 ISSUED 13 NOV 86 DURING TUE DRYDOCK EXAM BY 31 JULY 88.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Deck/Cargo
Issued 18 February 1988
Resolved
RE-INSTALL METAL GUARDS ON PLASTIC FUEL FILTER BOWLS, 1 EACH ON PORT AND STARBOARD THERMAL FLUID HEATERS.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Deck/Cargo
Issued 27 March 1987
Resolved
DEMONSTRATE PROPER OPERATION OF AUTOMATIC TRANSFER FROM LOW FIRE TO HIGH FIRE ON PORT THERMAL FLUID HEATER.
Condition: Unknown
Due 27 March 1987
Resolved 27 March 1987
Deck/Cargo
Issued 27 March 1987
Resolved
NEW VENTING ARRANGEMENT FOR BOTH HOT OIL EXPANSION TANKS MUST BE APPROVED BY [name withheld]/LB, CA.
Condition: Unknown
Due 27 March 1987
Resolved 27 March 1987
Deck/Cargo
Issued 27 March 1987
Resolved
IN LIEU OF COMPLETING ITEMS 1 & 2, AN APPROVED MODIFICATION TO THE CONTROL SYSTEM REMOVING THE COIL TEMPERATURE MONITOR CONTROLS WILL BE ACCEPTABLE. THIS MODIFICATION MUST BE AUTHORIZED BY THE MANUFACTURER AND [name withheld]/LB, CA.
Condition: Unknown
Due 27 March 1987
Resolved 27 March 1987
Deck/Cargo
Issued 27 March 1987
Resolved
DEMONSTRATE PROPER OPERATION OF #1 COIL TEMPERATURE MONITOR CONTROL IN PORTTHERMAL FLUID HEATER (ITEM 9 IN FIELD TEST PROCEDURE).
Condition: Unknown
Due 27 March 1987
Resolved 27 March 1987
Deck/Cargo
Issued 27 March 1987
Resolved
DEMONSTRATE PROPER OPERATION OF #1 THROUGH #5 COIL TEMPERATURE MONITOR CONTROLS IN STB THERMAL FLUID HEATER (ITEM 9 ON FIELD TEST PROCEDURE).
Condition: Unknown
Due 27 March 1987
Resolved 27 March 1987
Engineering
Issued 7 March 1987
Resolved
STBD THERMAL FLUID HEATER IS TO REMAIN SECURED UNTIL REPAIRS TO THERMAL FLUID PIPING IS COMPLETE AND A SATISFACTORY 150% HYDRO AND COMPLETE THERMALFLUID HEATER OPERATIONAL TESTS ARE COMPLETED.
Condition: Unknown
Due 7 March 1987
Resolved 7 March 1987
Documentation
Issued 7 March 1987
Resolved
SUPPLY THE APPROVED DRAWING REFERANCED IN THE STABILITY LETTER.
Condition: Unknown
Due 7 March 1987
Resolved 7 March 1987
Engineering
Issued 7 March 1987
Resolved
DO NOT OPERATE PORT THERMAL FLUID HEATER UNTIL PROPER OPERATIONAL TESTS CANBE SHOWN TO AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 7 March 1987
Resolved 7 March 1987
Deck/Cargo
Issued 7 March 1987
Resolved
REPLACE RADIATOR FAN MOTOR STBD PUMP ENGINE WITH HAZARDOUS LOCATION TYPE MOTOR PRIOR TO OPERATION OF STBD PUMP.
Condition: Unknown
Due 7 March 1987
Resolved 7 March 1987
Deck/Cargo
Issued 7 March 1987
Resolved
TEST RELIEF VALVES ON CARGO PUMPS AT NEXT ONLOADING OPERATION.
Condition: Unknown
Due 7 March 1987
Resolved 7 March 1987
Deck/Cargo
Issued 7 March 1987
Resolved
MAIN DECK BLENDING PUMP IS TO REMAINED SECURED UNTIL ALL WIRING AND MOTORS ARE MADE EXPLOSION PROOF AND ALL EXCESS GEAR IS REMOVED FROM ROOM.
Condition: Unknown
Due 7 March 1987
Resolved 7 March 1987
Construction/Loadline
Issued 13 November 1986
Resolved
MAKE PERMANENT REPAIRS TO FIRST AND FIFTH FRAMES FROM FORWARD BULKHEAD IN #3 PORT CARGO TANK IN WAY OF TOP THREE SIDE LONGS.
Condition: Unknown
Due 13 November 1986
Resolved 13 November 1986
Construction/Loadline
Issued 26 February 1986
Resolved
MAKE PERMANENT REPAIRS TO FIRST AND FIFTH FRAMES FROM FORWARD BULKHEAD IN #3 PORT CARGO TANK IN WAY OF TOP THREE SIDE LONGS.
Condition: Unknown
Due 26 February 1986
Resolved 26 February 1986
Documentation
Issued 26 February 1986
Resolved
PROVIDE COPY OF BARGE'S STABILITY LETTER AND LOAD LIMIT DIAGRAM DRAWING #1028-T5, REVISION 1, AND POST ONBOARD BARGE.
Condition: Unknown
Due 26 February 1986
Resolved 26 February 1986
Documentation
Issued 26 February 1986
Resolved
PROVIDE EVIDENCE OF COAST GUARD APPROVAL OF THE THERMAL UNIT HEATER'S INSTRUCTION BOOKLET IN ACCORDANCE WITH 46 CFR 63.05-95.
Condition: Unknown
Due 26 February 1986
Resolved 26 February 1986
Electrical
Issued 26 February 1986
Resolved
PROVIDE COVER FOR THE ELECTRICAL OUTLET ON AFT DECK HOUSE OUTBOARD.
Condition: Unknown
Due 26 February 1986
Resolved 26 February 1986
Electrical
Issued 26 February 1986
Resolved
TEST OVERSPEED AND LOW OIL PRESSURE TRIPS ON BOTH GENERATORS.
Condition: Unknown
Due 26 February 1986
Resolved 26 February 1986
Deck/Cargo
Issued 18 January 1986
Resolved
MAKE ALL CARGO TANKS AVAILABLE FOR INSPECTION BY A COAST GUARD INSPECTOR. ALL CARGO TANKS ARE TO BE CLEAN AND SAFE FOR MEN AND SAFE FOR FIRE.
Condition: Unknown
Due 18 January 1986
Resolved 18 January 1986
Construction/Loadline
Issued 18 November 1985
Resolved
DRYDOCK VESSEL OR PROCURE DRYDOCK EXTENTION.
Condition: Unknown
Due 18 November 1985
Resolved 18 November 1985
Deck/Cargo
Issued 23 April 1985
Resolved
MAKE PERMANENT REPAIRS TO PORT THERMAL FLUIDS HEATER REPAIRS ARE TO BE COMPLETE AND INCLUDE REWIRING ALL ELECTRICAL CONTROLS TO AS NEW CONDITION AND THEN PROVING OPERATION OF COMPLETE SYSTEM INCLUDING CONTROLS, SHUTDOWNSAND FUEL SYSTEMS TO A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Electrical
Issued 23 April 1985
Resolved
REPAIR AND PROVE OPERATION OF COOLING SYSTEM OF STARBOARD GENERATOR.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Deck/Cargo
Issued 23 April 1985
Resolved
CALIBRATE CARGO PUMP DISCHARGE PRESSURE GAUGES.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Deck/Cargo
Issued 23 April 1985
Resolved
PRESSURE TEST ALL CARGO LINES.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Deck/Cargo
Issued 23 April 1985
Resolved
PRESSURE TEST ALL CARGO LINES.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Electrical
Issued 23 April 1985
Resolved
INSTALL PROPER WIRING FOR BATTERIES USED TO POWER NAVIGATION LIGHTS.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Deck/Cargo
Issued 23 April 1985
Resolved
TEST PRESSURE RELIEF VALVES FOR CARGO PUMPS.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Engineering
Issued 3 December 1984
Resolved
INSTALL FLAME SHIELDS ON ALL GENERATOR AND FLUID HEATER RACOR FUEL FILTERS.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Engineering
Issued 3 December 1984
Resolved
INSTALL COVERS ON DIFERENTIAL PRESSURE SWITCH AND DRAFT REGULATORS ON BOTH FLUID HEATERS.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Engineering
Issued 3 December 1984
Resolved
PROVE OPERATION OF PORT FLUID HEATER AND CONDUCT AUTOMATION TEST WHICH IS TO INCLUDE THE FOLLOWING: FLAME FAILURE, LOW FLUID FLOW, LOW FLUID LEVEL, FLUID HIGH TEMPERATURE, DRAFT LIMIT, LOW FUEL OIL PRESSURE, LOW VOLTAGE, LOW ATOMIZING AIR PRESSURE, AND A MINIMUM 15 SECOND PERGE CYCLE.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Unknown
Issued 22 April 1983
Resolved
MAKE AVAILABLE FOR TESTING PORT AND STARBOARD THERMAL FLUID HEATERS AS PER APPROVED TEST PROCEDURE.
Condition: Unknown
Due 22 April 1983
Resolved 22 April 1983
Unknown
Issued 22 April 1983
Resolved
REPLACE FLAME SCREENS IN P/V VALVE FOR NO. 2 (P) CARGO TANK.
Condition: Unknown
Due 22 April 1983
Resolved 22 April 1983
Unknown
Issued 22 April 1983
Resolved
REPLACE FLAME SCREEN IN NO. 3 (P) CARGO TANK OPEN GAUGING PIPE.
Condition: Unknown
Due 22 April 1983
Resolved 22 April 1983
Unknown
Issued 22 April 1983
Resolved
REPLACE ONE DOG HANDLE ON NO. 4 (P) CARGO TANK HATCH COVER.
Condition: Unknown
Due 22 April 1983
Resolved 22 April 1983
Unknown
Issued 22 April 1983
Resolved
REPLACE PRESSURE GAUGE ON BALLAST WATER LINE, FORWARD OF BALLAST PUMP.
Condition: Unknown
Due 22 April 1983
Resolved 22 April 1983