Documentation record
Registered dimensions (L × B × D)98.0 ft × 29.5 ft × 11.7 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)99.9 ft × 29.5 ft × 15.9 ft
ITC tonnagegross 325 / net 97
BuilderHOUMA WELDERS INC · HOUMA, LA, UNITED STATES · built 1972
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSEATTLE, WA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 7 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Net Ton
97 - Convention (Subpart B), Net Ton
90 - Regulatory (Subpart C or D), Gross Ton
325 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 54
7 April 2026
Explosive Handling Operation-Military · Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8344726
31 March 2026
Appeal
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8392783
11 December 2025
COI Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8269772
9 September 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8230258
26 March 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8100343
8 January 2025
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8059811
26 April 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7888954
18 March 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7881283
22 August 2023
Explosive Handling Operation-Administrative · Explosive Handling Operation-Military
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7781424
6 March 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7646999
18 September 2022
Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7563223
2 September 2022
Explosive Handling Operation-Military
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7549628
25 February 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7397435
18 February 2021
Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7142591
26 August 2019
Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6795602
29 May 2019
In-Service Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6698863
4 June 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6214315
5 March 2015
Administration · Deficiency Check · Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5081559
14 January 2015
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5053173
23 June 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4938900
1 April 2013
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4561348
9 September 2012
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4436343
9 September 2012
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4438207
9 September 2012
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4438476
27 April 2012
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4318721
3 February 2012
Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4236371
1 September 2006
MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2765883
27 June 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2664565
30 November 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2543573
30 November 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2544539
9 November 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2531618
24 October 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2526526
4 August 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2452116
30 June 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2444179
26 June 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2389508
15 December 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2259936
18 May 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2071434
30 April 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2056179
28 April 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2055490
31 March 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2034812
14 January 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1984479
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979676
29 May 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1804804
24 March 2003
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1762729
27 December 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1723378
15 May 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1694047
10 May 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1617018
15 April 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1617178
20 November 2001
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1609239
3 May 2001
Uninspected Towing Vessel
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1068275
25 November 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 126422
4 August 2000
Uninspected Towing Vessel
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 823809
24 May 2000
Uninspected Towing Vessel
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 818831
18 December 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 72088
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 December 2025
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the following: (2) The system is installed, tested, and maintained in accordance with the design manual. The installed fire detection system was found inoperable. Provide evidence of servicing and proper operation of the fire detection system to attending marine inspector. 46 CFR 142.330(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 December 2025
Resolution: MI attended vessel following AGOW servicing. MI tested smoke detection. All SAT
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 December 2025
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. (b) If a storage room is provided, it may be any room or compartment that is free of ignition sources. Vessel was storing paint in a plastic deck box. Vessel to remove paints, coatings, or other flammable or combustible products or store in suitable cabinet as described in 46 CFR 142.225.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2026
Resolved 19 February 2026
Resolution: Vessel installed a cabinet for storage of flammable or combustible products on the upper deck port side behind the stacks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2025
No resolution recorded
Any piping system that penetrates the hull below the waterline must be fitted with an accessible valve, located as close to the hull penetration as is practicable, for preventing the accidental admission of water into the vessel either through such pipes or in the event of a fracture of such pipe. The non-integral keel coolers do not have a valve, directly plumbed to the port and starboard engines. Vessel shall install valves at the intake and discharge of each installed keel cooler at the vessels next drydock inspection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2028
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Compliance (COC)
Issued 26 April 2024
Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under § 67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel does not have a valid COD.
46 CFR 67.7
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2025
Resolved 17 June 2024
Resolution: COD issued to vessel on 08May2024
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 April 2024
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: (a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Excessive oil present in bilges and in pan under tow winch engine.
46 CFR 142.220
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2024
Resolved 14 May 2024
Resolution: Bilge cleaned
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 April 2024
Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by bulkheads. Doors may be
installed provided they are the self-closing type. Door to engine room is not self-closing.
46 CFR 144.410
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2024
Resolved 14 May 2024
Resolution: Door fixed to be self closing
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 April 2024
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. Lagging is missing on exhaust manifold of both main engines.
46 CFR 143.220
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2024
Resolved 14 May 2024
Resolution: New lagging purchased an installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2024
Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket. Each lifejacket must have a whistle firmly secured by a cord to the lifejacket. 02 lifejackets are missing a light and whistle.
46 CFR 141.340(g)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 14 May 2024
Resolution: 02 life jacket lights purchased and installed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 April 2024
Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act.
47 CFR 80.1005
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 14 May 2024
Resolution: Certificate on vessel now.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 18 March 2024
Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. MI observed holes and deterioration of tank top/deck plating in stbd fuel tank No. 1. Submit repair proposal to crop and renew affected area.
Action required: 705 - Other - as specified
Due 1 May 2024
Resolved 5 April 2024
Resolution: O/O inserted new steel plate and MI observed process. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 September 2022
Resolved
Vsl failed to submit required NOA as per 33CFR 160.
Action required: 10 - Deficiency Rectified
Due 18 September 2022
Resolved 18 September 2022
Resolution: Vessel's master submitted the requried NOA.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 25 February 2022
Resolved
Each towing vessel must be fitted with a general alarm that has installed in the engine room, a supplemental flashing red light that is identified with a sign that reads: "Attention general alarm- when alarm sounds or flashes go to your station". Signage missing in engine room. Operator to install sign with proper identification.
46CFR143.235
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2022
Resolved 28 February 2022
Resolution: Operator provided photograph showing general alarm signage installed in engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2022
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Properly label switchboards and distribution panels onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2022
Resolved 11 April 2022
Resolution: Received photograph from operator showing proper labeling on switchboard.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 25 February 2022
Resolved
Each life raft must be arranged to permit it to drop into the water from the deck on which it is stowed. Provide plan to office to meet the survival stowage requirement.
46CFR199.130
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2022
Resolved 29 March 2022
Resolution: MI attended vessel and verified life raft stowage arrangement.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 26 August 2019
Resolved
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2019
Resolution: Received required documentation needed to clear this deficiency.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 9 September 2012
Resolved
Screw down valve on engine room manifold from day tank to center tank not properly secured due to operator error. 2,600 gallons of fuel drained back in center tank causing the engines to seize.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 September 2012
Resolved 9 September 2012
Resolution: Valve secured and tank refilled with no leakage reported.