Inspection history · 127
23 March 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6930558
20 May 2019
Annual Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6686223
24 April 2018
Annual Inspection · Ballast Water Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6398738
5 August 2017
Damage Survey · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6231052
28 July 2017
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6223657
1 June 2017
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6162796
28 March 2017
COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6112759
21 December 2016
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6063241
12 December 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6057781
30 November 2016
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6050430
29 July 2016
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5956843
13 July 2016
Annual Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5944436
22 March 2016
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5838134
24 September 2015
Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5727673
10 May 2015
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5122652
21 January 2015
Cargo Tank Internal · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5056934
17 July 2014
MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4921883
21 April 2014
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4840426
7 April 2014
Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4831923
6 April 2014
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4831629
7 November 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4752198
6 August 2013
Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4656310
16 July 2013
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4656079
3 June 2013
Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4609744
26 September 2012
Damage Survey · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4451832
17 September 2012
COI Inspection · Examination of Repairs · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4437937
15 August 2012
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4412439
15 August 2012
Damage Survey · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4412861
11 June 2012
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4340457
14 May 2012
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4311539
24 October 2011
Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4174357
9 June 2011
Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4039316
21 July 2010
Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3803406
6 July 2010
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3787697
16 September 2009
Annual Inspection · MARPOL Annex I Examination · MTSA Verification · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3615846
3 December 2008
Annual Inspection · MARPOL Annex II Examination · MARPOL Annex V Examination · Administrative Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3373198
14 April 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3183713
30 July 2007
MARPOL Annex I Examination · MARPOL Annex V Examination · Hull Examination · Cargo Tank Internal · COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3011736
20 July 2007
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3001322
1 November 2006
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2812423
4 October 2006
MARPOL Annex II Examination · Damage Survey · MARPOL Annex I Examination · Internal Structural Exam · MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2793620
1 October 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2809366
30 May 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2665787
3 May 2006
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2639802
26 January 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2577943
27 December 2005
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2556617
30 August 2005
MTSA Verification · MARPOL Annex V Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2479167
15 June 2005
MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2391231
28 December 2004
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2260291
22 December 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2263516
19 December 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2262959
20 October 2004
Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2219779
24 October 2003
MARPOL Annex II Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1934991
18 October 2002
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1692219
17 October 2002
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1691123
30 September 2002
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1681963
23 July 2002
MARPOL Annex II Examination · MARPOL Annex I Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1650369
23 April 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1608310
28 March 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1603998
13 November 2001
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1384926
11 October 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1075331
17 July 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 772977
5 October 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 823455
12 September 2000
COI Inspection · MARPOL Annex V Examination · MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1445679
20 June 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 279690
20 June 2000
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1446956
27 April 2000
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1049055
2 March 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 504504
5 February 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 447657
1 December 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 539883
14 October 1999
MARPOL Annex II Examination · MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1375933
11 April 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 182488
27 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 469298
23 November 1998
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 810985
16 September 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 421775
16 September 1998
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 800632
8 October 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 506980
25 August 1997
Hull Examination · Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1364316
12 August 1997
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 782143
4 August 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 680681
25 July 1997
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1441276
23 July 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 152989
7 July 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 164445
11 June 1997
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 773833
14 March 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 22158
14 March 1997
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1467950
16 January 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 477985
23 September 1996
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1145185
21 June 1996
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1081858
7 February 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 532487
1 February 1996
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 873816
26 December 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 199850
26 December 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 442370
26 December 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 755187
27 November 1995
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 126043
10 October 1995
Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1465220
20 April 1995
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 525202
14 October 1994
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1177343
5 October 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 868765
26 September 1994
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 862172
9 September 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 451677
30 August 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 512300
7 May 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1354688
17 September 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 849595
20 July 1993
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 523327
12 July 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 843415
6 July 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1154177
17 June 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 179839
17 June 1993
Damage Survey
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1133949
28 April 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 482970
1 February 1993
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 502977
29 September 1992
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1261601
21 June 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249825
26 April 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1235939
2 August 1990
Deficiency Check · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1234860
17 July 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1212342
21 September 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 892489
27 June 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 896932
19 June 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1206646
20 January 1989
Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1032591
25 August 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1348432
19 July 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034578
21 March 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1032244
8 September 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1011913
11 August 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1029907
7 August 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1028996
9 July 1987
Initial Certification
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337159
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 24 April 2018
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel's alcohol testing devices were all expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2018
Resolved 27 April 2018
Resolution: Received photographic evidence of valid testing kit.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 24 April 2018
Resolved
An electric apparatus must be designed and installed to prevent any person from accidental contacting energized parts. A ground is indicated in both main generator panels (B-phase).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2018
Resolved 27 April 2018
Resolution: Received report that source of ground was isolated.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 April 2018
Resolved
Hazardous location equipment must be approved as suitable for use in the specific hazardous atmosphere for which it is installed. The use of non-approved equipment is prohibited. The ring buoy light located near the fore peak hatchway is not approved for use in a hazardous location.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 26 April 2018
Resolved 25 April 2018
Resolution: Operator removed improper ring-buoy light.
Construction/Loadline › Hull › Double Hull
Issued 28 July 2017
Resolved
Vessels shall comply with all applicable regulations pertaining to it's stability and load line requirements. Watertight integrity in the port double bottom void has been breached by a pin hole in an existing weld. Vessel shall provide a temp repair to the sat of CGMI prior to getting u/w for Newark, NJ. Vessel shall notify NY prior to ops in NY. Vessel shall permanently repair to sat of NY CGMI.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 5 August 2017
Resolution: Permanent repairs have been conducted.
Construction/Loadline › Hull › Hull Plating
Issued 28 March 2017
Resolved
See DDX Worklist (02) C/R Items
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 8 June 2017
Resolution: All worklist items cleared.
Construction/Loadline › Hull › Longitudinal Frame
Issued 22 March 2016
Resolved
Vessel has two overhead long frames (frames 3+4) with cracks approximately 5 ft from tank bulkead.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 23 March 2016
Resolution: Weld repairs were conducted to the satisfaction of the attending MI.
Lifesaving › Inflatable Liferafts › Float Free
Issued 29 September 2015
Resolved
Liferaft installation as configured is currently incapable of floatfree arrangement or manual release.
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 30 September 2015
Resolution: Vessel modified liferaft releasing apparatus to accomodate float free launching, as well as freeing up seized elements.
Engineering › Fuel Oil Service System › Piping
Issued 29 September 2015
Resolved
Fuel Lines on #1 and #2 aux generators leaking.
Condition: Improper/Lack of Maintenance
Due 13 October 2015
Resolved 29 September 2015
Resolution: Replaced leaking fuel lines.
Documentation › Logs/Records › Oil Record Book
Issued 29 September 2015
Resolved
Oil Record Book entries are missing name of cargo being loaded.
Due 29 September 2015
Resolved 29 September 2015
Resolution: Corrected on board to satisfaction of attending MI
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 29 September 2015
Resolved
Electric distribution panels are missing curcuit amperage load written on name plate.
Action required: 705 - Other - as specified
Due 29 October 2015
Resolved 1 October 2015
Resolution: Vessel provided directories with load ameperages included.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 29 September 2015
Resolved
#4 Stbd expansion trunk closed guaging device window missing sealing ring and is not preventing cargo vapor release.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 October 2015
Resolved 1 October 2015
Resolution: Closed gauging device serviced and sealing ring replaced.
Construction/Loadline › Hull › Hull Plating
Issued 10 May 2015
Resolved
Make permanent repairs to damage in way of the port aft rake gunwale to the satisfaction of attending USCG Marine Inspector at next scheduled dry dock.
Action required: 705 - Other - as specified
Due 19 March 2020
Resolved 9 June 2017
Construction/Loadline › Hull › Hull Plating
Issued 7 April 2014
Resolved
Crop and renew sharp insets in stern port rake (iwo turn between sideshell and rake)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 September 2014
Resolved 21 April 2014
Construction/Loadline › Hull › Weld
Issued 26 September 2012
Resolved
Crop and renew two under deck beams IWO of fractured steel. C&R floor frame IWO Fractured Steel. Grind and renew cracked welds along cargo tank vertical stiffeners.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2012
Resolution: ABS and USCG sited repair''s
Documentation › Manuals/Policy Documentation › Procedures and Arrangements Manual (NLS)
Issued 3 December 2008
Resolved
While conducting the documentation portion of the exam it was noticed that there was no P and A manual onboard the vessel. A copy of the P and A manual is to be brought onboard the vessel, until that time vessel is not authorized to carry any cargoes listed on their NLS certificate.
Action required: 705 - Other - as specified
Due 3 January 2009
Resolved 15 January 2009
Resolution: Vessel surrendered it''s NLS Certificate and no longer wishes to carry Annex II cargoes internationally.
Electrical › Electric Generation Source (service) › Generator
Issued 30 July 2007
Resolved
PROVE PROPER OPERATION OF STARBOARD GENERATOR
Due 16 November 2007
Resolved 5 November 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 30 July 2007
Resolved
PROPERTLY STENCIL VAPOR RECOVERY HOSES
Due 16 November 2007
Resolved 5 November 2007
Documentation › Certificates/Documents › International Load Line Certificate
Issued 30 July 2007
Resolved
PLACE A VALID LOAD LINE CERTIFICATE ON THE VESSEL
Due 16 November 2007
Resolved 5 November 2007
Lifesaving › Immersion Suits › Serviceable
Issued 4 October 2006
Resolved
Provide Proof of additional Immersion Suit per permissive manning requirement
Due 12 November 2006
Resolved 26 October 2006
Resolution: Received copy of receipt for purchase and delivery of new immersion suit for the PORTLAND
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Location
Issued 30 August 2005
Resolved
Vessel's B-V extinguisher does not reach all required area as per 46 CFR 34.50-5(c), it also must meet the requirements of 34.50-10(A) & 34.50-5(c).
Condition: Unknown
Due 31 October 2005
Resolved 25 October 2005
Resolution: Vessel installed additional B-V unit and relocated original extinguisher so the cargo area is adequately covered.
Deck/Cargo › Inert Gas System › Venting System
Issued 30 August 2005
Resolved
The gas analyzer was not working properly, and the crew was not familiar with proper operation of the system. No span gas was available to calibrate unit. Prove proper operation of IGS as well as crew familiarity prior to unit being used for inerting cargo tanks.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 20 December 2005
Resolution: System and crew tested satisfactorily in the presents of ABS Surveyor [name withheld].
Accommodation/Occupational Safety
Issued 12 September 2000
Resolved
Renew fwd rake vent screen.
Condition: Unknown
Due 5 October 2000
Resolved 5 October 2000
Lifesaving
Issued 12 September 2000
Resolved
Provide lights for all PFD's and immersion suits.
Condition: Unknown
Due 13 September 2000
Resolved 13 September 2000
Lifesaving
Issued 12 September 2000
Resolved
Renew Hammar L/R hydrostatic release (expires 30Sep00).
Condition: Unknown
Due 5 October 2000
Resolved 5 October 2000
Deck/Cargo
Issued 12 September 2000
Resolved
Properly stencil vapor hoses and renew 12 o'clock stud (broken).
Condition: Unknown
Due 5 October 2000
Resolved 5 October 2000
Accommodation/Occupational Safety
Issued 14 October 1999
Resolved
PROPERLY IDENTIFY REGULATED AREAS TO COMPLY WITH 46 CFR 197.535(c).
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Navigation
Issued 16 September 1998
Resolved
RENEW FLASHING AMBER BOW LIGHT WITH PROPER LIGHT HOUSING IN ACCORDANCE WITHNAV RULES.
Condition: Unknown
Due 16 October 1998
Resolved 23 October 1998
Unknown
Issued 25 July 1997
Resolved
VESSEL IS PERMITTED TO MAKE SCHEDULED TRIP TO ALBANY, NY WITH CARGO WITH TEMP REPAIRS. AFTER OFF-LOADING CARGO IN ALBANY, NY VESSEL IS TO PROCEED DIRECTLY TO DRYDOCK FACILITY FOR PERMANENT REPAIRS.
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Unknown
Issued 25 July 1997
Resolved
DURING VOYAGE TO ALBANY, NY A CREWMEMBER MUST CONDUCT A VISUAL INSPECTION OF TEMP REPAIRS EVERY TWO HOURS TO ENSURE WATERTIGHT INTEGRITY
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Construction/Loadline
Issued 25 July 1997
Resolved
MAKE TEMP REPAIRS TO TWO HOLES LOCATED AS FOLLOWS:_x001C_ 1) FWD RAKE, BAY 4, PORTSIDE, IWO #3 DEEPWEB TRANS FRAME & #5 BOTTOM _x001C_ LONG._x001C_ 2) FWD RAKE, BAY 4, PROTSIDE, IWO #6 BOTTOM LONG._x001C_
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Documentation
Issued 26 September 1994
Resolved
Place the original Certificate of Documentation on board the vessel. It must have a proper renewal sticker.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Deck/Cargo
Issued 26 September 1994
Resolved
Provide proof of annual testing of the cargo system pressure guage(s).
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Electrical
Issued 26 September 1994
Resolved
Clean the excess oil from the fan and air cooled heat exchanger on the #1 house generator prime mover.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Documentation
Issued 26 September 1994
Resolved
Fill in tank capacity and tank arrangement information in the oil record book.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Deck/Cargo
Issued 26 September 1994
Resolved
Mark out "200 MAWP" on all cargo hoses and remark with 150 psi MAWP.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Electrical
Issued 26 September 1994
Resolved
Provide a proper cover for the electrical shore tie receptical on the stern.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Deck/Cargo
Issued 26 September 1994
Resolved
Renew the deck water seal vent flame screen.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Electrical
Issued 26 September 1994
Resolved
Label the circuit breaker for the air compressor dryer and permanently mount the electrical box.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Electrical
Issued 26 September 1994
Resolved
Demonstrate a proper overspeed trip for the inert gas electrical system diesel generator.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Electrical
Issued 26 September 1994
Resolved
Renew/repair tachometer for #1 house generator.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Deck/Cargo
Issued 26 September 1994
Resolved
Remark both main deck emergency cargo pump shutdowns.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Deck/Cargo
Issued 26 September 1994
Resolved
Prior to using the inert gas system, prove proper operation of the blower fan/system shutdown during high temperature alarm.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Documentation
Issued 26 September 1994
Resolved
Display and distribute a community hot line number for the drug and alcoholprogram. (46 CFR 16.401 (a))
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Documentation
Issued 26 September 1994
Resolved
Provide a copy of the employer's policy regarding drug and alcohol use on board the vessel.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Electrical
Issued 26 September 1994
Resolved
Demonstrate overspeed shutdown on 4-71 house generator sets.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Electrical
Issued 26 September 1994
Resolved
Provide a cover for the open circuit breaker in the electrical panel at thegenerator room forward bulkhead.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Deck/Cargo
Issued 26 September 1994
Resolved
Repair the hydraulic oil leak in the void under the control room, on the starboard side. Pressurize the system for an attending USCG marine inspector.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Electrical
Issued 7 May 1994
Resolved
THE NEWLY INSTALLED LIGHTING SYSTEM IN WAY OF THE AFT RAKE IS TO REMAIN DE-ENERGIZED DURING ALL CARGO OPERATIONS; UNTIL MADE AVAILABLE FOR A_x001C_ SATISFACTORY FINAL INSPECTION BY A CG MARINE INSPECTOR.
Condition: Unknown
Due 8 May 1994
Resolved 8 May 1994
Electrical
Issued 7 May 1994
Resolved
THE NEWLY INSTALLED LIGHTING SYSTEM IN WAY OF AFT RAKE IS TO REMAIN DE- ENERGIZED DURING ALL CARGO OPERATIONS; UNTIL FINAL APPROVAL FOR PLANS BY THE COAST GUARD IS RECIEVED.
Condition: Unknown
Due 8 May 1994
Resolved 8 May 1994
Construction/Loadline
Issued 17 June 1993
Resolved
PREPARE AND PRESENT FORWARD STARBOARD RAKE FOR INTERNAL INSPECTION, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO 18 JULY 1993._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Lifesaving
Issued 2 August 1990
Resolved
INSTALL NEW GRAB LINE ON RING BUOY LOCATED AT DECK HOUSE.
Condition: Unknown
Due 2 August 1990
Resolved 2 August 1990
Electrical
Issued 2 August 1990
Resolved
LABEL ALL DISTRIBUTION PANELS LOCATED WITHIN DECK HOUSE.
Condition: Unknown
Due 2 August 1990
Resolved 2 August 1990
Electrical
Issued 2 August 1990
Resolved
LOCATE AND CORRECT FAULTS ON BOTH CIRCUITS ON MAIN DISTRIBUTION PANEL
Condition: Unknown
Due 2 August 1990
Resolved 2 August 1990
Electrical
Issued 2 August 1990
Resolved
CONNECT EMERGENCY BATTERY CIRCUIT TO FM RADIOS. PROVIDE COVER PLATE FOR JUNCTION BOX.
Condition: Unknown
Due 2 August 1990
Resolved 2 August 1990
Deck/Cargo
Issued 2 August 1990
Resolved
INSTALL NEW FLAME SCREENS ON PORT & STBD GOOSENECK F/O VENTS.
Condition: Unknown
Due 2 August 1990
Resolved 2 August 1990
Navigation
Issued 19 June 1989
Resolved
RENEW ELECTRICAL CABLE TO THE SPECIAL FLASHING YELLOW LIGHT FORWARD.
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989
Construction/Loadline
Issued 19 June 1989
Resolved
REPAINT THE VESSEL NAME ON THE VESSELS STARBOARD SIDE.
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989
Construction/Loadline
Issued 19 June 1989
Resolved
PROVIDE PROPER STRAINERS TO EACH BILGE SUCTION IN THE FORWARD AND AFTER RAKES. IAW 46 CFR 56.50-50(G)
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989
Lifesaving
Issued 19 June 1989
Resolved
PROVIDE APPROVED LIGHTS FOR THE 2 LIFE PRESERVERS ABOARD.
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989
Lifesaving
Issued 19 June 1989
Resolved
PROVIDE APPROVED LIGHTS FOR THE 2 EXPOSURE SUITS ABOARD.
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989
Deck/Cargo
Issued 19 July 1988
Resolved
PROVIDE VISIBLE SAFE WORK LOAD PLACARD ON PORT AND STARBOARD CARGO CRANES.
Condition: Unknown
Due 19 July 1988
Resolved 19 July 1988
Electrical
Issued 19 July 1988
Resolved
PROVE PROPER OPERATION OF #1 SHIP'S SERVICE GENERATOR.
Condition: Unknown
Due 19 July 1988
Resolved 19 July 1988
Fire Fighting
Issued 19 July 1988
Resolved
PROVIDE EMERGENCY EQUIPMENT IN ACCORDANCE WITH 46 CFR 96.35-5.
Condition: Unknown
Due 19 July 1988
Resolved 19 July 1988
Lifesaving
Issued 19 July 1988
Resolved
PROVE ANNUAL TESTING OF HYDRAULIC RELEASE UNIT IN ACCORDANCE WITH 46 CFR 160.062.
Condition: Unknown
Due 19 July 1988
Resolved 19 July 1988
Lifesaving
Issued 19 July 1988
Resolved
PROVIDE WATER LIGHTS ON BOTH RING LIFE BUOYS.
Condition: Unknown
Due 19 July 1988
Resolved 19 July 1988
Construction/Loadline
Issued 21 March 1988
Resolved
(A)4'6"X8' SECTION OF HULL PLATE RENEWED IN STBD RAKE AT SHEER STRAKE RAKE & BILGE (B) 5'X8' SECT.OF BILGE WRAPPER RENEWED AT #1 STBD TANK BOUNDARY(C)5'X6' SECTION OF TANK INTERNAL RENEWED BETWEEN #1 DOUBLE BOTTOM CARGOTANK.(D).8'X12' HULL PLATE AT SHEER STRAKE RENEWED IN #4 CARGO TANK.
Condition: Unknown
Due 21 March 1988
Resolved 21 March 1988
Unknown
Issued 9 July 1987
Resolved
PROVIDE A CERTIFIED COPY OF THE VESSEL'S CERTIFICATE OF DOCUMENTATION TO A COAST GUARD MARINE INSPECTOR OR THE INSPECTION DEPARTMENT OF [name withheld].
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Unknown
Issued 9 July 1987
Resolved
PRIOR TO OPERATION OF THE HYDRAULIC SYSTEM, PROVIDE EVIDENCE THAT ABS HEADQUARTERS HAS ACCEPTED THE HYDRAULIC SYSTEM AS A NON-VITAL SYSTEM UNDER THE PROVISIONS OF 46 CFR 58.30-50. THIS INCLUDES ACCEPTANCE OF THE TWO HOSE HANDLING CRANES AS "FAIL-SAFE" EQUIPMENT.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Unknown
Issued 9 July 1987
Resolved
PROVIDE ORIGINAL COPY OF THE VESSEL'S CERTIFICATE OF FINANCIAL RESPONSIBILITY ON BOARD.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987