Documentation record
Registered dimensions (L × B × D)118.7 ft × 34.0 ft × 14.6 ft
Registered tonnagegross 198 / net 134
ITC dimensions (L × B × D)120.2 ft × 34.0 ft × 16.4 ft
ITC tonnagegross 417 / net 125
BuilderMCDERMOTT SHIPYARD · AMELIA, LA, UNITED STATES · built 1974
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPHILADELPHIA, PA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 30 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it417 - Convention (Subpart B), Gross Ton
198 - Regulatory (Subpart C or D), Gross Ton
125 - Convention (Subpart B), Net Ton
134 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 51
19 February 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8081426
12 January 2023
COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7619825
8 February 2022
Administrative Inspection · Initial Certification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7394075
21 November 2021
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7354973
15 November 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7350995
10 May 2021
ISM Oversight
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7195341
22 June 2020
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7002655
1 June 2017
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6162796
11 May 2017
MTSA Verification · Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6144068
29 March 2017
Type not recorded
No type recorded · USCGC LINE (WYTL 65611) · USCG Northeast District (CGD-NE) · Activity 6117304
28 March 2017
Type not recorded
No type recorded · USCGC LINE (WYTL 65611) · USCG Northeast District (CGD-NE) · Activity 6117328
26 February 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6101661
21 December 2016
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6063241
12 December 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6057781
30 November 2016
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6050430
29 July 2016
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5956843
9 June 2016
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5902792
9 June 2016
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5903438
2 June 2014
Industry Initiated Exam · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4876931
8 November 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4749434
7 November 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4752198
16 August 2013
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4714039
16 July 2013
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4656079
26 January 2013
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4529306
11 September 2012
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4437872
15 August 2012
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4412439
27 April 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4296725
26 April 2012
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4296529
9 March 2011
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3962198
4 December 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3907563
10 November 2010
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3889314
3 January 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3123960
9 August 2007
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3023531
25 April 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2915088
18 January 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2858445
2 November 2006
Administrative Inspection · Uninspected Other · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2813163
12 February 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2306542
8 December 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2260806
10 June 2002
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1633104
6 October 2001
Type not recorded
No type recorded · USCGC GRAND ISLE (WPB 1338) · USCG Northeast District (CGD-NE) · Activity 1523968
16 April 2001
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 155113
8 January 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1478790
29 August 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 26066
20 March 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 14856
12 November 1996
Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1175255
18 July 1996
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 25788
27 February 1996
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 388618
4 October 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 24451
26 September 1995
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 179562
23 May 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 34549
12 April 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1199259
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 January 2023
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The port side fuel shutoff valve was non operational at the time of inspection due to seized plug, which prevented access to fuel shut off valve.
46CFR143.260(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 January 2023
Resolution: Proof of fuel shutoff valve operational test was provided and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 January 2023
Resolved
The valve must be operable from a safe place outside the space where the valve is installed. The wrench needed to close the fuel shutoff valve was located inside the engine room at the time of inspection.
46CFR143.260(d)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 January 2023
Resolution: Proof of fuel shutoff valve operational test was provided and found satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 January 2023
Resolved
A registry endorsement entitles a vessel to employment in the foreign trade. Vessel does not have registry endorsement and is not authorized for International routes until registry endorsement is issued. Provide updated COD to TPO.
46CFR67.17(a)
Action required: 705 - Other - as specified
Resolved 8 March 2023
Resolution: Received updated COD with registry endorsement.
10 - Safety of Navigation › N/A - No Subsystem › Long-range identification and tracking system (LRIT)
Issued 12 January 2023
Resolved
The following ships, while engaged on an international voyage, are required to transmit position reports: A cargo ship, including high speed craft, of 300 gross tonnage or more. Vessel is in the process of changing over LRIT services to new ownership and is not authorized for International routes until proper documentation has been issued. Once process is complete provide documentation to TPO.
33CFR169.205(b)
Action required: 705 - Other - as specified
Resolved 28 February 2023
Resolution: Received satisfactory tech report from Mackay Marine stating required equipment has been installed and activated.
01 - Certificates & Documentation › 011 - Ships Certificates › International Air Pollution Certificate (IAPP)
Issued 12 January 2023
Resolved
An International Air Pollution Prevention Certificate shall be issued, after an initial or renewal survey in accordance with the provisions of regulation 5 of this annex, to any ship 400 gross tons and above engaged in voyages to ports or offshore terminals under the jurisdiction of other parties. Vessel does not have a valid IAPP. Until IAPP is issued vessel is not authorized for International routes. Provide IAPP to TPO upon issuance.
MARPOL ANNEX VI/6
Action required: 705 - Other - as specified
Due 13 October 2023
Resolved 11 October 2023
Resolution: Amended COI to show no IAPP is not required due to vessel not conducting international transits
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 November 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Vessel experienced loss/reduction in propulsion on the port engine.
Vessel is restricted prior to movement pending a tech report, TPO report stating cause of the problem, repairs made, and sat operational test.
46 CFR 143.205(a)
60AC
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 November 2021
Resolution: Receive tech and tpo/abs report