ANGLER'S DREAM

ANGLER'S DREAM is a 1995 passenger vessel (inspected). The Coast Guard has recorded 53 inspections since 1993, most recently in April 2026, along with 196 deficiencies.

Records from 1993 to 2026. Most recent: inspection, 21 April 2026.

Built
1995
Last inspected
21 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ3534
396505
Flag
UNITED STATES
366905360, 367699010 (licence lapsed)
Maury page id
psix-396505

Inspections, by type

…with no type recorded5
Years with a record 31 calendar years (1993–2026)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.0 ft × 16.0 ft × 4.0 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderATLANTIC BOATS INC (HULL) · KINSTON, NC, UNITED STATES · built 1995
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portST PETE BEACH, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 1 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI4471MMSI 367699010 · expired · compulsorily equipped · granted 24 October 2015, cancelled 7 March 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDB5052MMSI 366905360 · expired · voluntarily equipped · granted 14 August 2013, cancelled 21 October 2023 · licensed under a name not among this hull’s recorded names (not shown)
WCT2374MMSI not assigned · expired · compulsorily equipped · granted 6 July 1995, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PLACIDA QUEEN Passenger (Inspected) · MISLE 43920 · 2 July 2007 · activity 3081722

Inspection history · 53

21 April 2026 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8344719
11 August 2025 Hull Examination · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8207328
4 March 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8082460
28 February 2024 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7864159
11 September 2023 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7786047
9 February 2023 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7620716
8 February 2022 Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7378028
1 October 2021 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7324922
1 February 2021 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7124695
4 May 2020 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6948067
24 September 2019 Deficiency Check · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6820477
8 November 2018 DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6576849
14 December 2017 Drydock Exam · Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6308644
19 December 2016 Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6054086
29 September 2016 Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5993083
3 December 2015 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5764102
19 August 2014 Hull Examination · COI Inspection · Examination of Repairs · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4948022
14 February 2012 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4244083
5 December 2011 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4202042
15 September 2010 Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3838737
1 October 2008 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3320094
6 August 2008 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3285927
24 July 2008 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3285083
2 July 2007 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3081722
1 June 2006 COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2665837
10 August 2005 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2457138
3 February 2005 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2286109
14 December 2004 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2258817
11 August 2004 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2162781
5 March 2004 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2018635
4 November 2003 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1938777
24 February 2003 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1748552
11 December 2002 Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1716449
4 June 2002 Re-Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1625948
2 September 2001 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1075504
7 August 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1070834
5 June 2001 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1399638
2 April 2001 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1059886
6 February 2001 Hull Examination · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1401412
11 October 2000 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1441745
17 November 1999 Hull Examination · Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1426291
20 July 1998 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1364803
16 June 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 79791
11 June 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 793116
25 November 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 773970
24 October 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 28433
24 September 1997 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1413250
6 August 1997 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1427391
7 October 1996 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 838440
5 August 1996 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1371532
1 August 1995 Plan Review "T" Boat · Initial Certification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 874281
31 July 1995 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1188380
25 October 1993 Initial Construction-Excluding Oversight
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1132849

Deficiency record · 196

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 April 2026 Resolved
A vessel must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant [name withheld] observed fire buckets were not serviceable. Replace fire buckets. 46 CFR 181.610 701c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2026
Resolution: Received picture of new fire buckets.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 21 April 2026 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. MI observed that the Master`s medical card was not on board. 705c: Master can't operate vessel until medical card is received. 46 CFR 10.301 (a) 705c
Action required: 705 - Other - as specified
Resolved 27 April 2026
Resolution: Received picture of Master's medical card.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 21 April 2026 Resolved
Each vessel that operates on High Seas must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. MI observed that the Hydrostatic Release Unit had expired. Replace. 705c: Vessel restricted to less than 3 nautical miles from shore. 46 CFR 180.64 705c
Action required: 705 - Other - as specified
Resolved 23 April 2026
Resolution: Received picture of new EPIRB hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 April 2026 Resolved
Each life jacket carried on a vessel on oceans or coastwise must have a life jacket light secured to the life jacket. 02 life jacket lights not operating. 46 CFR 180.75 705c: Vessel is restricted to 40 passengers during daylight hours.
Action required: 705 - Other - as specified
Resolved 1 June 2026
Resolution: 02 new lights installed. Applicable restriction lifted.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 April 2026 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI observed that the stern light was inoperative. 705c: Vessel is restricted to daylight operations and 2 nautical miles visibility. 46 CFR 183.420 705c
Action required: 705 - Other - as specified
Resolved 1 June 2026
Resolution: Stern light repaired. Applicable restriction lifted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 April 2026 Resolved
Fire extinguishing equipment installed on a vessel must maintained in accordance with a recognized industry standard. MI observed that the monthly inspection maintenance logs were missing for all fire extinguishing equipment. Provide record. 46 CFR 181.500 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 June 2026
Resolution: Record provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 April 2026 Resolved
Electrical equipment on a vessel must be installed to protect person onboard and the vessel from electrical hazards. MI observed dead end wires in starboard side forward storage space and beneath the operating station. Secure source of electrical power. 46 CFR 183.200 (b) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 June 2026
Resolution: Dead end wires secured.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 March 2025 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. MI observed vessel unable to provide proof of drills conducted. 46 CFR 185.520(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2025
Resolved 26 March 2025
Resolution: Image received of adequate MOB and and abandon ship drill log.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 March 2025 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. MI observed vessel unable to provide proof of drills conducted. 46 CFR 185.524(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2025
Resolved 26 March 2025
Resolution: Image received of adequate fire fighting training and drill log.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 March 2025 Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. MI observed vessel unable to provide proof of EPIRB testing. 46 CFR 185.728 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2025
Resolved 26 March 2025
Resolution: Image received of adequate EPIRB test log.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 March 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI observed dead end wires beneath steering console at operating station. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2025
Resolved 26 March 2025
Resolution: Video received showing hazards from wiring beneath steering console corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 4 March 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI observed unserviceable retroreflective tape on both life floats. 46 CFR 176.808 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2025
Resolved 26 March 2025
Resolution: Received image of serviceable retroreflective tape.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 4 March 2025 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. MI observed portable fire extinguisher at operating station unsecured to vessel and not clearly visible. 46 CFR 181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2025
Resolved 26 March 2025
Resolution: Image received of fire extinguisher properly mounted at operating station.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 4 March 2025 Resolved
A vessel of more than 65 feet in length must carry at least one rescue boat unless the cognizant OCMI determines that the vessel is sufficiently arranged and equipped to allow the crew to recover a helpless person from the water. MI observed crewmember not secured to vessel while recovering person from the water during MOB drill. 46 CFR 180.210 (a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2025
Resolved 26 March 2025
Resolution: Image received of life jacket and securing line for use during MOB drill/emergency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 February 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing machinery failure. MI observed hydraulic leak on steering ram and under the helm. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2024
Resolved 29 February 2024
Resolution: System was repaired.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 February 2024 Resolved
An interconnected detection and alarm system must be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required to be protected by the interconnected detection and alarm system. MI observed that system was not alarming when tested. 46 CFR 181.450(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2024
Resolved 28 February 2024
Resolution: System was re-programmed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 February 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. MI observed that first aid kit was expired. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2024
Resolved 7 March 2024
Resolution: Received picture of new first aid kit.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 February 2024 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel was unable to provide proof of drills conducted. 46 CFR 185.520(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2024
Resolved 4 March 2024
Resolution: Vessel provided log.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 February 2024 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel was unable to provide proof of drills conducted. 46 CFR 185.524(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2024
Resolved 7 March 2024
Resolution: Received drill log.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 February 2024 Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Vessel was unable to provide proof of EPIRB testing. 46 CFR 185.728 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2024
Resolved 7 March 2024
Resolution: Received test log.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, and electrical shock. MI observed dead end wires behind depth sounder display, under pilothouse console, and aft end of passenger compartment on weather deck. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2024
Resolved 18 March 2024
Resolution: Received pictures of removed dead end wires.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 28 February 2024 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. MI observed that tat the required medium frequency radio was not inspected according to most recent Communications Act Safety Radiotelephony Certificate. CODE 705: Vessel may not operate beyond 20 nautical miles from land until radio is inspected by an FCC-licensed technician. 47 CFR 80.903
Action required: 705 - Other - as specified
Due 28 February 2024
Resolved 7 March 2024
Resolution: Received MF radio FCC certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 28 February 2024 Resolved
Each EPIRB must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. Master stated that EPIRB had not been tested. 46 CFR 185.728 (a)
Action required: 10 - Deficiency Rectified
Due 28 February 2024
Resolved 28 February 2024
Resolution: Master tested EPIRB.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 February 2024 Resolved
A vessel on an oceans, and coastwise route must carry six hand red flare distress signals and six hand orange smoke distress signals. Vessel was missing one of required distress signals. 46 CFR 180.68 (a)
Action required: 10 - Deficiency Rectified
Due 28 February 2024
Resolved 28 February 2024
Resolution: Vessel retrieved distress signal.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2022 Resolved
New installations of electrical equipment and material, and the repair or replacement of wire and cable, on an existing vessel, which are completed to the satisfaction of the cognizant Officer in Charge, Marine Inspection (OCMI) on or after March 11, 1996, must comply with this part. Identified two new battery chargers installed on the vessel. Owner shall submit electrical plans to MSC for the new installation. 46 CFR § 183.115
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2022
Resolved 9 March 2022
Resolution: Electrical plan update sent to MSC for review/approval. Verified installation matches plans submitted.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 8 February 2022 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The medium frequency radio was not connected to the emergency battery power source. Vessel is restricted to routes less than 20 miles from shore until rectified. 46 CFR § 184.25-1 and 46 CFR § 183.01-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2022
Resolved 10 February 2022
Resolution: A FCC Inspector attended the vessel and verified the SSB radio connection to the emergency power source.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Identified a heavily corroded positive 10 AWG conductor on the supply side of the anchor winch and an inoperable 120 amp breaker. 46 CFR § 183.05-35
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2022
Resolved 9 March 2022
Resolution: New conductors installed for the brake winch. Electrical installation meets subchapter T standard. New class T fuse installed in compartment number 1 for conductors to the winch. Fuse is rated 120 amps.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2022 Resolved
All cable and wire must Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. Identified new installation of conductors in the steering space without supports. 46 CFR § 183.340
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2022
Resolved 9 March 2022
Resolution: All cables and conductors in the laz space found properly supported.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 February 2022 Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must be of at least 18.3 meters (60 feet) in length. The ring buoy had 43 feet of length of life line attached to it. 46 CFR § 180.70
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2022
Resolved 10 February 2022
Resolution: The owner purchased 60 feet of floating line and attached it to the ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 February 2022 Resolved
The equipment required for lifefloats and buoyant apparatus must meet the following specifications: Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant. Identified 3 fractured and decayed paddles for the life float. 46 CFR § 180.175
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2022
Resolved 10 February 2022
Resolution: The owner purchased 3 new paddles of at least 4 feet in length and placed them into service on the life float.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 October 2021 Resolved
A vessel that is exposed to salt water not more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every tow years. Upon administrative review, vessel found to be overdue for drydock and internal exams. Vessel shall undergo drydock and internal structural exams prior to the carriage of passengers. 46CFR176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2021
Resolved 8 October 2021
Resolution: Completed credit DD/ISE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 February 2021 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. The operator installed a new power bilge pump that was not a replacement in kind in each watertight compartment after March 11, 1996. The submersible electric bilge pump located in the #2 compartment (numbered 1-4, fore to aft) was not operational when tested by the crew. Demonstrate proper operation of the submersible electric bilge pump located in compartment #2 to the attending marine inspector. 46 CFR 182.520(e)
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2021
Resolved 3 February 2021
Resolution: The operator replaced the electric submersible bilge pump in kind with a UL listed bilge pump. The pump was operationally tested; all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 February 2021 Resolved
As per 46 CFR 182.115(d), on or before March 11, 1999, an existing vessel must comply with the bilge high level requirements in 182.530. The bilge high level alarm located in the #2 compartment (numbered 1-4, fore to aft) was not operational when tested by the crew. A visual and audible alarm was not provided when tested. Demonstrate proper operation of the bilge high level alarm located in compartment #2 to the attending marine inspector. 46 CFR 182.530
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2021
Resolved 3 February 2021
Resolution: The operator discovered a disconnected wire to the bilge alarm. The wire was removed and replaced in kind. The bilge alarm was tested and a visible/audible alarm sounded for the space at the operating station.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 February 2021 Resolved
The minimum number of portable fire extinguishers required on each vessel shall be determined by the OCMI in accordance with Table 181.30-1(a). The portable fire extinguisher required to be located at the wheelhouse/steering station was not on board. Provide (1) 10 B:C portable fire extinguisher of an approved type in the wheelhouse/steering station. 46 CFR 181.30-1(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2021
Resolved 3 February 2021
Resolution: The operator purchased a new 10 BC portable fire extinguisher that is mounted at the operating station.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 February 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of a large enough scale to make safe navigation possible. The operator did not have nautical charts on board. Provide adequate and up-to-date charts of a large enough scale to make safe navigation possible. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 3 February 2021
Resolution: The operator purchased new navigation charts for the intended voyage.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 February 2021 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in 4.03-2 of subchapter A of this chapter shall comply with the requirements of 4.06 in subchapter A of this chapter. The vessel is authorized to complete oceans voyages of up to 100 nm from land. The operator did not have alcohol test strips on board for the crew in the event of a marine casualty. The vessel is restricted to voyages no further than 2 hours from an alcohol testing facility until alcohol test strips are on board. 46 CFR 185.212
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2021
Resolved 17 February 2021
Resolution: The operator purchased alcohol test strips and placed them on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 8 May 2020 Resolved
46 CFR 180.200(a)(2) Each survival craft required on the vessel must remain in good and serviceable condition. Life floats have paint and reflective tape degradation on outside of buoyant apparatus'. Make repairs to life float as necessary and replace reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 13 May 2020
Resolution: Owner replaced tape and repainted life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 May 2020 Resolved
46 CFR 180.70(d) A vessel must carry one floating waterlight, unless it is limited to daytime operation. Floating waterlight does not ignite. Vessel is restricted to daytime operations until replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 18 May 2020
Resolution: Owner purchased new floating waterlight. Tested sat.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 24 September 2019 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Vessel's engine room 40-B:C indicator was displaying it as discharge and unavailable for use. Service or replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2019
Resolution: Owner had 2 40:BC replaced and 1 serviced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 24 September 2019 Resolved
Sea chests, sea valves and sea strainers must be opened for examination. Both main engine raw water intake sea valves are of ball valve design and frozen in the open position. Repair or replace and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 September 2019
Resolution: Proved proper operation of both valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2019 Resolved
Propellers, shafts, bearings shall be made available for inspection. Port strut cutlass bearing appears to not be seated properly and is creeping forward of the strut. Re-secure or replace port strut cutlass bearing. Prior to DD credit.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 27 September 2019
Resolution: Bearing reset in strut.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2019 Resolved
Piping for vital systems are those systems that are vital to a vessel's survivability and safety. STBD M/E and auxiliary generator's raw water intake piping in poor condition and showing severe wear. Replace prior to DD credit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 September 2019
Resolution: Replaced hoses.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 September 2019 Resolved
Deck rails must be designed and constructed to withstand a point load of 200LBS applied at any point in any direction. Port side, aft, top rail cracked. Repair within 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 September 2019
Resolution: Rail repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 November 2018 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry six hand red flare distress signals and six hand orange smoke distress signals, or 12 hand red flare distress signals, approved in accordance with 46CFR160. 8 of the 12 red flare distress signals on board were expired. Replace. - 46CFR180.68(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2018
Resolution: Vessel owner replaced expired distress signals.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 November 2018 Resolved
A pre-engineered fixed gas fire extinguishing system must be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector. Fireboy extinguisher had maintenance pin left from last service, preventing manual actuation. Have certified technician remove pin. - 46CFR181.420(a)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2018
Resolution: Owner removed pin from Fireboy extinguisher.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 November 2018 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB. Hydrostatic release for Category 1 EPIRB is expired. Replace in accordance with manufacturer's instructions. Vessel is limited to 3 nautical miles. - 46CFR180.64
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 8 November 2018
Resolution: Owner replaced in-kind with unit that expires in November 2020.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 November 2018 Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that the pump is permanently mounted. Pump in forepeak is not permanently mounted. Mount. - 46CFR182.520(e)(3)
Action required: 15 - Rectify deficiencies by next port
Due 22 November 2018
Resolved 21 November 2018
Resolution: Owner mounted pump.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 November 2018 Resolved
Employers must maintain records of chemical tests, including pre-employment and random testing, and must make these records available to Coast Guard officials upon request. Owner had no record of pre-employment or random testing. Provide record of testing from ASAP to USCG. - 46CFR16.260(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 14 December 2018
Resolution: Owner provided proof of pre-employment testing for all employees enrolled in consortium.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 November 2018 Resolved
Marine employers may use sponsoring organizations, or may use contractors, to conduct the random chemical testing programs required by this part. Owner had no record of current year contract with ASAP. Provide record of current year contract to USCG. - 46CFR16.230(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 21 December 2018
Resolution: Owner provided current year contract.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 November 2018 Resolved
An EAP training program must be conducted for the employer’s crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer’s supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Owner had no record of training for crewmembers or supervisor. Provide record of training to USCG. - 46CFR16.401(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 21 December 2018
Resolution: Owner provided record of training.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 November 2018 Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with the requirements of 46 CFR 4.06. Alcohol test strips provided by ASAP used for testing within 2 hours of a serious marine incident are expired. Replace. - 46CFR16.240
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 21 December 2018
Resolution: Owner provided alcohol testing strips.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 November 2018 Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Owner had no record of current year MIS report from consortium. Provide report to USCG. - 46CFR16.260(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 21 December 2018
Resolution: Owner provided record of current year MIS report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 November 2018 Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer’s policy regarding drug and alcohol use in the workplace. Owner had no record of signed substance abuse policy for each employee as required by program. Provide record of signed policies for each employee to USCG. - 46CFR16.401(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 21 December 2018
Resolution: Owner provided record of signed substance abuse policy.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 November 2018 Resolved
The certificate of inspection and stability letter addendum must be posted under glass or other suitable transparent such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. Certificates are either expired or missing. Replace with copies of valid certificates. - 46CFR176.302
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 20 December 2018
Resolution: Owner placed expired or missing documents under glass in accomodation space.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 November 2018 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Letters and numbers must be at least 2 inches high. Markings for number and sizes of life jackets are faded. Renew markings. - 46CFR185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 21 December 2018
Resolution: Owner replaced lifejacket markings to the satisfaction of the attending Marine Inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 November 2018 Resolved
Each EPIRB must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. The EPIRB test shall be logged or otherwise documented, as applicable. Owner had no record of monthly EPIRB testing. Provide record to USCG. - 46CFR185.728(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 14 December 2018
Resolution: Owner created EPIRB testing log and entered first monthly test.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 8 November 2018 Resolved
The owner or operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part. Crew training shall be logged for review by the Coast Guard upon request. The training entry shall include the following information: Date of the training and general description of the training topics. Training and drills were last logged on 03NOV17. Provide updated training record to USCG. - 46CFR185.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 21 December 2018
Resolution: Owner provided updated training and drill logs.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 November 2018 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date tide tables and current tables. Vessel could not provide current or tide tables. Provide record of up-to-date tide and current tables to USCG. - 46CFR184.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 14 November 2018
Resolution: Owner provided correct current/tide tables.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 November 2018 Resolved
The radio installation must be clearly marked with the call sign, the ship station identity and other codes as applicable for the use of the radio installation. VHF radio was marked with incorrect call sign. Replace with correct call sign. - 46CFR184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 14 December 2018
Resolution: Owner marked operating station with Call Sign.
Communications › Radio Communications › EPIRB
Issued 15 December 2017 Resolved
EPIRB located under hardtop, relocate EPIRB in a float free location, to the satisfaction of attending marine inspector. 46CFR180.64
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 December 2017
Resolved 20 December 2017
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 15 December 2017 Resolved
Current employee list not provided by marine employer, provide current employee list to the satisfaction of attending marine inspector. 46CFR16
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2017
Resolved 20 December 2017
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 15 December 2017 Resolved
Show current CPR certification for 50% of the crew, to the satisfaction of attending marine inspector. 46CFR185.530
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 December 2017
Resolved 20 December 2017
Resolution: Not required.
Construction/Loadline › Hull › Transverse Frame
Issued 14 December 2017 Resolved
overhead wooden transverse framing in engine room overhead, is rotting and wasted in some areas crop and renew as neccessary. 46 CFR 176.600 (d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2018
Resolved 15 February 2018
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 December 2017 Resolved
14 type 1 PFD's fabric was tearing open and taken out of service. Replace. Passenger count reduced to 28 adult and six child total. 46 CFR 180.71
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 20 December 2017
Lifesaving › Lifefloat › Float-free Link
Issued 14 December 2017 Resolved
Weak link was not connected to vessel. 46CFR 180.130 (A)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2017
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 14 December 2017 Resolved
Lifejacket lockers need to be relabeled. 46 CFR 180.78
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 20 December 2017
Lifesaving › Lifefloat › Markings
Issued 14 December 2017 Resolved
Vessel names is not on lifloats, mark vessel's name on life floats. 46 CFR 185.604 (2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 15 December 2017
Stability › Unintentional Flooding › General
Issued 14 December 2017 Resolved
Port side shaft packing is not adequate. Shaft is a leaking a steady stream of water. Repack or tighten packing. 46 CFR 176.800(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2017
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 December 2017 Resolved
remote fuel shutoffs not labeled. 46 CFR 185.608. Label shut offs.
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 15 December 2017
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 14 December 2017 Resolved
Fuel fill hose not properly bonded. 46 CFR 182.455 (g)
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 15 December 2017
Lifesaving › Visual Distress Signals (General) › Expired
Issued 14 December 2017 Resolved
4 day/ night flares were expired leaving only 08 onboard. 46 CFR 180.68
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2017
Lifesaving › Lifefloat › Retroreflective Material
Issued 14 February 2017 Resolved
Life Floats and life bouy reflective tape worn out, must replace. 46CFR160
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 3 April 2017
Resolution: Retro repaired satisfactorily.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 19 December 2016 Resolved
Provide all applicable documentation to attending marine inspector iaw 46CFR176.404.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2017
Resolved 14 February 2017
Resolution: Owner provided new documnets.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 19 December 2016 Resolved
Provde proper number, type, and service of portable fire extinguishers (B-II) iaw 46CFR181.30-1.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2017
Resolved 14 February 2017
Resolution: Owner installed new B-II fire extinguisher.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 19 December 2016 Resolved
Prove proper operation and service of pre-engineered fixed gas fire extinguisher iaw 46 CFR 181.420.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2017
Resolved 14 February 2017
Resolution: Owner had pre-engineered fixed gas fire extinguisher serviced.
Engineering › Bilge Water Management System › Not Operational
Issued 19 December 2016 Resolved
Prove poper operation of bilge high level alarm iaw 46 CFR 182.115(d).
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2017
Resolved 14 February 2017
Resolution: Owner replaced bilge alarm diplays.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 December 2016 Resolved
Prove proper operation of floating water light on ring life bouy iaw 46CFR180.70 (d).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2017
Resolved 14 February 2017
Resolution: Owner replaced water lights.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 December 2016 Resolved
Provide first aid kit iaw 46 CFR 184.710.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2017
Resolved 3 April 2017
Resolution: First aid test, Sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 December 2016 Resolved
Properly connect wires near fireboy iaw 46 CFR 183.01-15
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2017
Resolved 14 February 2017
Resolution: Owner removed loose wires.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 December 2016 Resolved
Provide crew training on man overboard, fire, and abandonship procedures iaw 46 CFR 185.502/524
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2017
Resolved 14 February 2017
Resolution: Owner successfully completed man overboard, fire, and abandonship drill
Stability › Watertight Integrity › Weathertight Enclosure
Issued 1 November 2016 Resolved
Foward watertight hatch on main deck; wood panel deck material around hatch rotted underneath FRP deck.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 7 November 2016
Resolution: Owner replace rotted wood around fwd watertight hatch.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 October 2016 Resolved
Do not carry passengers until credit dry dock is complete by Sector St. Pete.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2016
Resolution: Owner completed credit dry dock.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 December 2015 Resolved
Provide on board 100 aspirin total for first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 24 December 2015
Resolution: O/O provided proper amount of asprin for first aid kit.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 3 December 2015 Resolved
Current vent covers are not suitable, replace / repair.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 December 2015
Resolved 24 December 2015
Resolution: O/O repaired engine room vents for proper closure and seaing surfaces.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 3 December 2015 Resolved
Provide on board a total of 44 adult size life jackets and 5 child size life jackets.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 December 2015
Resolution: Verified number of life jackets available onboard (44 adult, 5 child)
Engineering › Steering Gear System › Ram
Issued 3 December 2015 Resolved
Repair / replace leak on steering ram.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 January 2016
Resolved 12 February 2016
Resolution: Owner rebuilt steering ram replacing all internal seals. SAT
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 19 August 2014 Resolved
Remove and repair/replace all ovbd skin valves.
Action required: 705 - Other - as specified
Resolved 26 August 2014
Construction/Loadline › Structures › Superstructure
Issued 19 August 2014 Resolved
Remove all wood "[name withheld]" in fwd compartment next to bunk, and re-support wire run with metal supports throughout compartment, IAW 46 CFR 183.340 (b) (4).
Action required: 705 - Other - as specified
Resolved 2 October 2014
Electrical › Electric Supply System (service) › Cable
Issued 19 August 2014 Resolved
Replace all plastic wire supports with metal ones in engine room, IAW 46 CFR 183.340 (b) (4).
Action required: 705 - Other - as specified
Resolved 2 October 2014
Construction/Loadline › Penetrations › Valve Flange
Issued 19 August 2014 Resolved
Prove proper operation of both main engine sea valves.
Action required: 705 - Other - as specified
Resolved 26 August 2014
Construction/Loadline › Structures › Deck Plating
Issued 19 August 2014 Resolved
Re-Attach main deck to overhead deck frames at the #4, 5, 6th frames from the fwd engineroom bulkhead.
Action required: 705 - Other - as specified
Resolved 2 October 2014
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 19 August 2014 Resolved
Replace both shaft log hoses and clamps on both shafts.
Action required: 705 - Other - as specified
Resolved 9 September 2014
Construction/Loadline › Hull › Side Shell
Issued 19 August 2014 Resolved
Locate and fix water leak in port aft corner of vessel.
Due 15 November 2014
Resolved 5 November 2014
Resolution: Water leak in port aft corner repaired.
Engineering › Feedwater/Condensate Water System › Piping
Issued 19 August 2014 Resolved
Clean and mount bait well strainer
Due 29 October 2014
Resolved 5 November 2014
Resolution: Bait well strainer cleaned and mounted.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 19 August 2014 Resolved
Learn to operate Single Side Band / Medium Frequency Radio.
Action required: 705 - Other - as specified
Resolved 5 November 2014
Resolution: Observed operation of Single Side Band / Medium Frequency Radio.
Lifesaving › Lifefloat › Float-free Link
Issued 19 August 2014 Resolved
Replace approved weak link on lifefloat.
Due 29 October 2014
Resolved 31 October 2014
Resolution: Owner/operator emailed a receipt for the approved weak link.
Lifesaving › Lifejacket/PFD (Type IV) › Lights
Issued 19 August 2014 Resolved
Replace or provide information for 03 waterlight batteries.
Due 29 October 2014
Resolved 31 October 2014
Resolution: Owner/operator provided information from the manufacturer that the waterlight battery they purchased is interchangeable with the battery required on the waterlight.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 August 2014 Resolved
Provide amonia inhalents
Due 29 October 2014
Resolved 31 October 2014
Resolution: Owner/operator provided a receipt for purchased ammonia inhalents.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 June 2006 Resolved
Refresh expired items in the first aid kit.
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 7 June 2006
Resolution: Completed
Documentation › Logs/Records › Drug Test Records
Issued 1 June 2006 Resolved
Provide a copy of the current APCA contract to include current members.
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 7 June 2006
Resolution: Completed
Documentation › Certificates/Documents › FCC SSL
Issued 1 June 2006 Resolved
Provide proof of compliance with a valid FCC Safety Radio Telephony certificate onboard.
Action required: 705 - Other - as specified
Due 14 June 2006
Resolved 7 June 2006
Resolution: Completed
Deck/Cargo › Holds/Tanks › Hatch
Issued 14 December 2004 Resolved
Renew bow hatch gasket.
Due 14 January 2005
Resolved 3 February 2005
Construction/Loadline › Hull › Hull Plating
Issued 14 December 2004 Resolved
GRIND AND REPAIR PROPERLY SEVERL MARKED NICKS IN GELCOAT.
Due 14 January 2005
Resolved 14 December 2004
Construction/Loadline › Structures › Deck Plating
Issued 14 December 2004 Resolved
FILL IN THE FOUR UNUSED HOLES IN MAIN DECK AFT.
Due 14 January 2005
Resolved 14 January 2005
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 11 August 2004 Resolved
PROVIDE PROOF OF MIS REPORT SUBMISSION FOR DAPI PROGRAM.
Due 11 September 2004
Resolved 23 August 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 August 2004 Resolved
PROVE PROPER OPERATION OF MASTHEAD AND STERN LIGHT.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2004
Resolved 23 August 2004
Lifesaving › Hand Flares › Quantity
Issued 11 August 2004 Resolved
PROVIDE 6 NEW RED HAND DISTRESS SIGNALS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2004
Resolved 23 August 2004
Communications › Radio Communications › EPIRB
Issued 11 August 2004 Resolved
PROVIDE AN OPERATIONAL/REGISTERED CAT I 406mhz EPIRB ONBOARD VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2004
Resolved 23 August 2004
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 11 August 2004 Resolved
INSTALL A WEAK LINK ON THE LIFEFLOAT PAINTER.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2004
Resolved 23 August 2004
Lifesaving › Buoyant Apparatus › Serviceable
Issued 11 August 2004 Resolved
REPAIR CRACKS ON LIFEFLOATS AS PER MANUFACTURERS INSTRUCTIONS. ALSO ADD 1 PADDLE AND APPLY CORRECT VESSEL NAME TO LIFEFLOATS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2004
Resolved 23 August 2004
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 11 August 2004 Resolved
PROVIDE 8 ADDITIONAL ADULT TYPE I ONBOARD VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2004
Resolved 23 August 2004
Engineering › Fuel Oil Service System › Valve, Control
Issued 11 August 2004 Resolved
PROVIDE OPERATION OF REMOTE FUEL TANK SHUT-OFF VALVE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2004
Resolved 23 August 2004
Engineering › Bilge Water Management System › Pump
Issued 11 August 2004 Resolved
MOUNT THE FOREPEAK BILGE PUMP SECURELY.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2004
Resolved 23 August 2004
Engineering › Bilge Water Management System › Strainer
Issued 11 August 2004 Resolved
CLEAN PLASTIC BAGS FROM #2 BILGE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2004
Resolved 23 August 2004
Documentation › Certificates/Documents
Issued 30 October 2003 Resolved
Post stability letter. LEGACY COMPONENT DESC: Stability Letter
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2003
Resolved 4 November 2003
Documentation › Markings/Placards
Issued 30 October 2003 Resolved
Post a waste management plan. LEGACY COMPONENT DESC: Garbage Placard
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2003
Resolved 4 November 2003
Operations/Management › Drug and Alcohol Testing
Issued 30 October 2003 Resolved
Provide a drug testing contract w/all employees listed; provisions for a SMI and an EAP. LEGACY COMPONENT DESC: Employee Coverage
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2003
Resolved 4 November 2003
Documentation › Markings/Placards
Issued 30 October 2003 Resolved
Post an Emergency Instruction List.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2003
Resolved 4 November 2003
Navigation › Piloting/Steering
Issued 30 October 2003 Resolved
Provide a proper navigation chart to cover vessel route. LEGACY COMPONENT DESC: Marine Charts
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2003
Resolved 4 November 2003
Navigation › Collision/Grounding Avoidance
Issued 30 October 2003 Resolved
Provide new running lights (port starboard & all around). LEGACY COMPONENT DESC: Navigation Lights
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2003
Resolved 4 November 2003
Electrical › Electric Supply System (service)
Issued 30 October 2003 Resolved
Properly hang/support loose electrical wiring throughout vessel. LEGACY COMPONENT DESC: Cable
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2003
Resolved 4 November 2003
Electrical › Electric Supply System (service)
Issued 30 October 2003 Resolved
Provide regular nuts on battery terminals vice wing nuts. LEGACY COMPONENT DESC: Battery Installation
Due 30 November 2003
Resolved 4 November 2003
Engineering › Fuel Oil Service System
Issued 30 October 2003 Resolved
Properly protect/support fuel hoses in engineroom. LEGACY COMPONENT DESC: Hose
Due 30 November 2003
Resolved 4 November 2003
Electrical › Lighting (emergency)
Issued 30 October 2003 Resolved
Provide a portable light near engineroom hatch. LEGACY COMPONENT DESC: Battery Operated Lantern
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2003
Resolved 4 November 2003
Engineering › Fuel Oil Service System
Issued 30 October 2003 Resolved
Adjust forward remote fuel shutoff valve linkage. LEGACY COMPONENT DESC: Valve, Control
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2003
Resolved 4 November 2003
Lifesaving › Buoyant Apparatus
Issued 30 October 2003 Resolved
Provide a float light for the 10 man Lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2003
Resolved 4 November 2003
Lifesaving › Lifebuoys
Issued 30 October 2003 Resolved
Provide a new ringbouy onboard vessel. LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2003
Resolved 4 November 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 30 October 2003 Resolved
Tighten all handrails. LEGACY COMPONENT DESC: Deck Rail
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2003
Resolved 4 November 2003
Fire Fighting › Ventilation Systems
Issued 30 October 2003 Resolved
Provide vent closures for engineroom vents. LEGACY COMPONENT DESC: Duct Hatches
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2003
Resolved 4 November 2003
Engineering › Bilge Water Management System
Issued 30 October 2003 Resolved
Provide a portable bilge pump onboard vessel. LEGACY COMPONENT DESC: Pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2003
Resolved 4 November 2003
Operations/Management
Issued 30 October 2003 Resolved
Provide proof that user fee has been paid.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2003
Resolved 4 November 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 30 October 2003 Resolved
Provide a guard for glass globe light in accomodation space. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 30 November 2003
Resolved 5 March 2004
Construction/Loadline › Hull
Issued 10 December 2002 Resolved
REPAIR AREAS ON BOTH PORT AND STBD FWD HULL WHERE ANCHOR FLUKES SCRAPE HULL. FILL AREAS WITH EPOXY AND NOTIFY INSPECTORS FOR RE-INSPECT.
Action required: 705 - Other - as specified
Due 15 December 2002
Resolved 11 December 2002
Resolution: FILLED WITH EPOXY MIX, REPAIR SAT
Stability › Watertight Integrity
Issued 10 December 2002 Resolved
REPAIR/REPLACE GASKET FOR LAZARETTE HATCH.
Action required: 705 - Other - as specified
Due 15 December 2002
Resolved 28 January 2003
Resolution: GASKET REPLACED AND DOGGING DEVICES RE-ADJUSTED FOR WATERTIGHT FIT.
Engineering › Steering Gear System
Issued 10 December 2002 Resolved
SECURELY FASTEN PORT RUDDER QUADRANT TO CONNECTING ARM WITH LARGER SIZE BOLT AND WASHER. LEGACY COMPONENT DESC: Linkage
Action required: 705 - Other - as specified
Due 15 December 2002
Resolved 24 February 2003
Resolution: OWNER ORDERED AND INSTALLEDPROPER FASTNER TO CONNECT STEERING ARM TO QUAD
Engineering › Sea-water System (primary cooling)
Issued 10 December 2002 Resolved
PROVIDE CHAFING MATERIAL FOR RAW WATER INTAKE HOSE FOR STBD ENGINE.
Action required: 705 - Other - as specified
Due 15 December 2002
Resolved 28 January 2003
Engineering › Sea-water System (primary cooling)
Issued 10 December 2002 Resolved
PROVIDE CHAFING FOR PORT SECTION OF FLEX EXAUST HOSE WHERE IT RESTS ON LONGITUDINAL STRINGER. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 15 December 2002
Resolved 28 January 2003
Engineering › Sea-water System (primary cooling)
Issued 10 December 2002 Resolved
RE-FASTEN TO BRACKET RAW WATER STRAINER, PORT ENGINE LEGACY COMPONENT DESC: Sea Chest
Action required: 705 - Other - as specified
Due 15 December 2002
Resolved 28 January 2003
Fire Fighting › Structural Fire Protection - General
Issued 10 December 2002 Resolved
FILL PENETRATIONS IN AFT ENGINE ROOM BULKHEAD WITH FIRE RETARDANT FOAM
Action required: 705 - Other - as specified
Due 15 December 2002
Resolved 28 January 2003
Electrical › Electrical Distribution System (service)
Issued 10 December 2002 Resolved
PROVIDE METALLIC WIRE CLIPS W/ RUBBER GROMMETS SPACED NO FURTHER THAN 24" FOR ALL WIRING IN ENGINE SPACE. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 15 December 2002
Resolved 28 January 2003
Resolution: OWNER USED METAL STRAPS WITH NO RUBBER GROMMETS. INSTRUCTED OWNER THAT THESE WERE NOT THE RIGHT KIND AND MUST BE REPLACED WITH WHAT IS REQUIRED.
Engineering › Bilge Water Management System
Issued 10 December 2002 Resolved
PROVIDE POSITIVE CLOSURE VALVE AT SIDE SHELL FOR ALL 12 VOLT SUBMERSIBLE PUMPS. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 15 December 2002
Resolved 28 January 2003
Resolution: OWNER INSTALLED VALVES AT BILGE PUMP END OF HOSE VICE AT THE PENETRATION. OWNER CORRECTED THIS THE FOLLOWING DAY.
Electrical › Lighting (service)
Issued 10 December 2002 Resolved
PROVIDE GLOBE AROUND LIGHT BULB IN ENGINE SPACE. ALSO, ADDITIONAL GLASS GLOBE IN ENGINE SPACE MUST HAVE WIRE CAGE OR REPLACE WITH PLASTIC GLOBE. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 15 December 2002
Resolved 28 January 2003
Engineering › Sea-water System (primary cooling)
Issued 10 December 2002 Resolved
CLEAN OUT HOSE FOR RAW WATER GENERATOR INTAKE.
Action required: 705 - Other - as specified
Due 15 December 2002
Resolved 28 January 2003
Operations/Management › Drug and Alcohol Testing
Issued 4 June 2002 Resolved
PROVIDE EAP TRAINING AND LOG SUCH TRAINING. LEGACY COMPONENT DESC: EAP Training Requirements
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 26 June 2002
Documentation › Logs/Records
Issued 4 June 2002 Resolved
PROVIDE TRAINING LOG AS WELL AS LIFE SAVING INSPECTION LOG.
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 26 June 2002
Lifesaving › Hand Flares
Issued 4 June 2002 Resolved
PROVIDE SIX ADDITIONAL CG APPROVED DAY/NIGHT DISTRESS SIGNALS. LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2002
Resolved 4 June 2002
Resolution: PURCHASED 6 NEW DISTRESS SIGNALS.
Communications › Alarms/Indicators
Issued 4 June 2002 Resolved
PROVIDE MODULAR UL APPROVED SMOKE DETECTOR IN FWD BERTHING AREA. LEGACY COMPONENT DESC: Fire Alarm
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 26 June 2002
Construction/Loadline
Issued 4 June 2002 Resolved
PROVIDE APPROVAL LETTER FOR INSTALLATION OF NEWLY INSTALLED CREW BERTHING. FTMD RECEIVED FAX APPROVAL LTR. FROM LADY ESTERO HOWEVER IT WAS MARKED" RETURNED FOR REVISION" AND IS NOT AN APPROVAL LETTER.
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 7 June 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 4 June 2002 Resolved
PROVIDE CG APPROVED FIRST AID KIT OR PROVIDE CONTENTS LIST AND UPDATE MISSING ITEMS.
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 26 June 2002
Resolution: PROVIDED CONTENT LIST AND UPDATED MISSING ITEMS
Construction/Loadline › Penetrations
Issued 4 June 2002 Resolved
FILL PENETRATIONS IN FORWARD ENGINE ROOM BULKHEAD. PENETRATIONS MUST BE VAPOR TIGHT AND FILLED WITH A FIRE RETARDANT FILLER.
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 26 June 2002
Resolution: FILLED PENETRATIONS WITH FIRE RETARDANT FOAM
Navigation
Issued 5 June 2001 Resolved
Install RADAR. Operation limited to 20 NM from harbor of safe refuge untilcomplete
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Lifesaving
Issued 5 June 2001 Resolved
Attach water light to life ring with 3 - 6 feet of line and corosion resistant clip.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Electrical
Issued 5 June 2001 Resolved
Install hexnuts on all battery connections.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Engineering
Issued 5 June 2001 Resolved
Install flame impingement bowl on all raycor fuel oil filters.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Unknown
Issued 11 October 2000 Resolved
SHOW COMPLIANCE WITH CG DRUG TESTING REGS. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Electrical
Issued 11 October 2000 Resolved
PROPERLY INSTALL COVERS FOR BATTERY BOXES IN E/R.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Documentation
Issued 11 October 2000 Resolved
PROVE UPDATES ON CERTIFICATE OF DOCUMENTATION. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Lifesaving
Issued 11 October 2000 Resolved
PROPERLY MARK CHILDRENS PFD STORAGE.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Lifesaving
Issued 11 October 2000 Resolved
SHOW PROOF OF LOGGED TRAINING AND DRILLS.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Navigation
Issued 11 October 2000 Resolved
PROVIDE LIGHT LIST, NOTICE TO MARINERS AND TIDE TABLES.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Navigation
Issued 11 October 2000 Resolved
PROVIDE AND POST EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Lifesaving
Issued 11 October 2000 Resolved
REPAIR OUTER COVERINGS ON ALL 3 LIFE FLOATS. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Lifesaving
Issued 11 October 2000 Resolved
PROPERLY INSTALL TETHER LINE SERVING LIFE FLOATS. AS INSTALLED NOW, THE LINE WILL TANGLE AND FOUL HINDERING FLOAT FREE ARRANGEMENT OF LIFE FLOATS.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Lifesaving
Issued 11 October 2000 Resolved
RENEW DETERIORATED TAG LINES ON LIFE FLOATS. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Lifesaving
Issued 11 October 2000 Resolved
REGLUE/SECURE RETRO REFLECTIVE TAPE WHERE IT IS COMING LOOSE FROM LIFE FLOATS.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Lifesaving
Issued 11 October 2000 Resolved
RENEW RETRO REFECTIVE TAPE ON ALL 6 CHILD PFDS AND ON THE TOPS OF ALL ADULTPFDS WHERE THE SILVER MATERIAL IS MISSING. NO NIGHT OPERATIONS UNTIL CLEARED.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Electrical
Issued 11 October 2000 Resolved
PROPERLY SECURE ALL WIRING FOR ALL BILGE PUMPS.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Lifesaving
Issued 11 October 2000 Resolved
RENEW OR REPAIR RING BUOY. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Navigation
Issued 11 October 2000 Resolved
PROPERLY REPAIR TACHOMETER IN PILOT HOUSE. (PORT MDE).
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Electrical
Issued 11 October 2000 Resolved
PROPERLY SECURE LIGHTS IN E/R WITH PROTECTIVE GLOBES/CAGES.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Accommodation/Occupational Safety
Issued 11 October 2000 Resolved
PROPERLY SECURE SEWAGE OVERBOARD DISCHARGE VALVE.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Fire Fighting
Issued 11 October 2000 Resolved
INSTALL NOZZLE ON FIRE HOSE. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Documentation
Issued 11 October 2000 Resolved
RENEW FCC RADIOSAFETY TELEPHONY CERTIFICATE. VESSEL RESTRICTED TO NMT 1000FEET FROM SHORE UNTIL CLEARED.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Fire Fighting
Issued 11 October 2000 Resolved
RENEW B-I EXTINGUISHER. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Documentation
Issued 11 October 2000 Resolved
PROVIDE WASTE MANAGEMENT PLAN AND GARBAGE LOG.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Lifesaving
Issued 11 October 2000 Resolved
PROVIDE AND POST PFD DONNING PLACARDS.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Navigation
Issued 11 October 2000 Resolved
PROPERLY REPAIR SIGNALING HORN.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Lifesaving
Issued 11 October 2000 Resolved
PROVIDE 3 ADDITIONAL RED FLARES. VESSEL RESTRICTED TO LAKES, BAYS, SONDS AND RIVERS UNTIL CLEARED.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Fire Fighting
Issued 11 October 2000 Resolved
RENEW BOTH B-II FIRE EXTINGUISHERS. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Deck/Cargo
Issued 11 October 2000 Resolved
PROVIDE AND INSTALL ANCHOR AND ANCHOR LINE.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Navigation
Issued 11 October 2000 Resolved
PROPERLY SECURE STEERING ARM WITH PROPER SECURING NUT OR DOUBLE NUT. (PORTEND OF STEERING ARM).
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Navigation
Issued 11 October 2000 Resolved
PROPERLY REPAIR RUDDER POST LEAK.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Engineering
Issued 11 October 2000 Resolved
PROPERLY REPAIR STBD MDE. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Electrical
Issued 11 October 2000 Resolved
PROPERLY REPAIR ALL ELECTRICAL OUTLETS USED FOR ELECTRIC FISHING REELS. NUMEROUS MISSING COVERS.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Lifesaving
Issued 11 October 2000 Resolved
RENEW THE 2 FLOATING WATERLIGHTS WHICH SERVE 2 OF THE 3 LIFE FLOATS. THE 2FLOATING WATERLIGHTS ARE MISSING THE RETAINING CLIPS THAT HOLD THE LIGHT TOGETHER. NO NIGHT OPERATIONS UNTIL CLEARED.
Condition: Unknown
Due 11 October 2000
Resolved 11 October 2000
Navigation
Issued 17 November 1999 Resolved
PROPERLY REPAIR ELONGATED HOLE ON RUDDER TIE BAR.
Condition: Unknown
Due 23 November 1999
Resolved 23 November 1999
Navigation
Issued 17 November 1999 Resolved
REPLACE LENSES ON ALL RUNNING LIGHTS.
Condition: Unknown
Due 23 November 1999
Resolved 23 November 1999
Lifesaving
Issued 17 November 1999 Resolved
PROVIDE PERSONAL MARKER LIGHTS ON ELEVEN ADULT PFD'S.
Condition: Unknown
Due 23 November 1999
Resolved 23 November 1999
Electrical
Issued 17 November 1999 Resolved
RENEW BATTERY CABLE CONNECTION ON CENTER BATTERY IN ENGINE ROOM.
Condition: Unknown
Due 23 November 1999
Resolved 23 November 1999
Fire Fighting
Issued 17 November 1999 Resolved
PROVE PROPER OPERATION OF FIRE/BILGE PUMP.
Condition: Unknown
Due 23 November 1999
Resolved 23 November 1999
Navigation
Issued 17 November 1999 Resolved
PROVE PROPER OPERATION OF THE RADAR.
Condition: Unknown
Due 23 November 1999
Resolved 23 November 1999
Documentation
Issued 25 November 1997 Resolved
VESSEL IS RESTRICTED TO A COASTWISE ROUTE, NOT FURTHER THAN 20 MILES FROM AHARBOR OF SAFE REFUGE UNTIL STABILITY IS PROVEN TO BE SATISFACTORY FOR OPERATION IN EXPOSED WATERS.
Condition: Unknown
Due 25 November 1997
Resolved 25 November 1997
Electrical
Issued 5 August 1996 Resolved
IN ALL INTERIOR COMPARTMENTS, PROVIDE PROPER COVERS FOR ALL JUNCTION BOXES AND OUTLETS.
Condition: Unknown
Due 5 August 1996
Resolved 5 August 1996
Electrical
Issued 5 August 1996 Resolved
IN ALL INTERIOR COMPARTMENTS, REPLACE TWISTED (WIRE NUT) CONNECTIONS WITH APPROVED CONNECTIONS.
Condition: Unknown
Due 5 August 1996
Resolved 5 August 1996
Electrical
Issued 5 August 1996 Resolved
PROVIDE WATERPROOF MARINE ELECTRICAL OUTLETS AND COVERS FOR ALL WEATHER DECK OUTLETS.
Condition: Unknown
Due 5 August 1996
Resolved 5 August 1996
Documentation
Issued 1 August 1995 Resolved
VSL HAS NO RADIOTELPHONY CERTIFICATE. VSL TO OPERATE NO MORE THAN 1000 FT. FROM SHORE UNTIL VSL ISSUED RADIOTELPHONY CERTIFICATE.
Condition: Unknown
Due 17 August 1995
Resolved 17 August 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.