MAURY USCG vessel records
← All vessels

CHRISTINE ANDERSON

Built
1994
Last inspected
11 September 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 September 2025
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC6286
397636
Flag
UNITED STATES
Maury page id
psix-397636

Documentation record

Registered dimensions (L × B × D)199.6 ft × 66.0 ft × 16.5 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)199.6 ft × 66.0 ft × 16.5 ft
ITC tonnagegross 1,365 / net 487
BuilderNICHOLS BROS BOAT BLDG · PORTLAND OR, UNITED STATES · built 1994
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSTEILACOOM, WA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 12 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
1365 - Convention (Subpart B), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
487 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 36 inspections, each with its date, unit and type; 27 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 36

11 September 2025 Annual Inspection · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8231961
12 February 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8078909
11 February 2025 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8082140
11 December 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8045329
1 November 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8028158
9 September 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8045885
8 May 2024 Drydock Extension
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7908793
15 November 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7825845
3 June 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7745721
19 May 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7692247
24 March 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7656797
1 March 2023 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7647961
31 January 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7636640
18 October 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7575044
28 May 2022 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7473853
12 May 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7449132
26 October 2021 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7340370
6 November 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7089699
6 October 2020 Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7076481
9 March 2020 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6923458
3 January 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6884560
1 November 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6841137
28 December 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6603654
25 November 2018 Security Breach
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6685740
16 November 2018 MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6581034
6 November 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6576823
6 November 2018 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6576869
7 September 2018 Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6535064
1 June 2018 In-Service Inspection · Drydock Extension · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6431711
10 April 2018 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6389439
27 March 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6443291
23 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6360382
2 January 2018 Damage Survey · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6331634
3 November 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6294890
19 August 2016 Deficiency Check · MTSA Verification · Underwater Inspection in lieu of Drydock · COI Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5977653
3 March 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5828244

Deficiency record · 27

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 11 December 2024 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Vessel #2 end void 3 ddx plug leaking, temp repaired with belzona. Vessel to affect permanent repairs as soon as able.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 January 2025
Resolved 3 January 2025
Resolution: Leaking docking plug welded shut as temporary repair until vessel goes to drydock in 2026 to conduct permanent repair.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 December 2024 No resolution recorded
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel to submit plans and make permanent repairs to area of hull where docking plug in #3 void on the #2 end was welded in place. Repairs to be completed at vessels next scheduled drydock in 2026. 46CFR115.700
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 May 2023 Resolved
1 service generator is inoperable
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2023
Resolved 19 May 2023
Resolution: Tech rep from Tacoma Diesel came and installed a new oil pressure swtich. Verified operation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 March 2023 Resolved
The main steering gear and rudder stock must be of adequate strength for and capable of steering the vessel at maximum ahead service speed, which must be demonstrated to the satisfaction of the cognizant Officer in Charge, Marine Inspection. Vessel operator reported loss of steering on the #2 rudder while vessel was underway. Provide tech report to include any repairs and complete sea trials prior to departure. Cite: 46CFR119.600, 46CFR58.25-10
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2023
Resolution: MI received Hamilton Jet technician report and witnessed successful sea trials.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 January 2023 Resolved
Fire pump was leaking while running and has pinhole leak in casing. Pressure at pump was 22psi.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2023
Resolved 23 March 2023
Resolution: Vessel replaced fire pump and MI's observed successful test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 31 January 2023 Resolved
#1 MDE high temp alarm was disconnected and inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2023
Resolved 1 March 2023
Resolution: Vessel O/O corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 January 2023 Resolved
Nonconductive mats were missing in front of main switchboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2023
Resolved 1 March 2023
Resolution: Vessel O/O corrected
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 January 2023 Resolved
Sprinkler head on #2 end, outboard side of car lane 4 was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2023
Resolved 1 March 2023
Resolution: Vessel O/O corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 January 2023 Resolved
Vessel was unable to test bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2023
Resolved 23 March 2023
Resolution: MI's observed successful test
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 October 2022 Resolved
Vessel installed new motor starter and alarm panel without notifying CG. Alterations to machinery or equipment affecting the safety of the vessel must not be made without the approval of the cognizant [name withheld] plans to MSC and provide CG proof of plan approval.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2023
Resolved 19 January 2023
Resolution: MI's confirmed newly installed equp, was installed IAW MSC approved plans.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 18 October 2022 Resolved
A vessel must be operated in accordance with applicable laws and regulations in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Until MSC approval of newly installed systems, limit vessel speed to 5 KTS or less within 200 yards of dock if possible given the current and sea state.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2023
Resolved 19 January 2023
Resolution: MI's confirmed newly installed equp, was installed IAW MSC approved plans.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 October 2022 Resolved
The master of a vessel shall have examined the propulsion controls of the vessel prior to getting underway. Until MSC approval of newly installed systems, vessel must conduct visual and operational inspections of the motor starters prior to carriage of passengers and keep logs of such inspections ready and available to inspectors upon request.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2023
Resolved 19 January 2023
Resolution: MI's confirmed newly installed equp, was installed IAW MSC approved plans.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 12 May 2022 Resolved
See activity 7449132. Repairs or alterations to the hull, machinery or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] damage and heavy corrosion in the bottom hull plating between frames 5-7 reported to USCG by operator, shall be repaired at at next scheduled dry dock due NLT OCT 31, 2022. Prior to starting repairs, a proposed repair plan shall be submitted to the local OCMI for approval. 46 CFR 115.700
Action required: 705 - Other - as specified
Due 31 October 2022
Resolved 1 December 2022
Resolution: Resolved during DDX, MISLE case 7575044.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2021 Resolved
Several ring buoys were found to have faded markings. Replace/restore markings on ring buoys.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2021
Resolved 3 November 2021
Resolution: Ring buoys markings restored.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2021 Resolved
Signage on fire extinguisher enclosures that describes how to open enclosure has faded. Restore or replace signage.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2021
Resolved 3 November 2021
Resolution: Signage restored.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2021 Resolved
#1 steering compartment has a broken bracket that is supposed to support deck plating in this space. As a regularly checked space, crew is suseptible to injury from stepping on decking when conducting their checks and maintenance. Repair bracket within 30 days.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2021
Resolved 18 November 2021
Resolution: Bracket has been welded and secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2021 Resolved
Women's head smoke detector broken/does not pass smoke test. Replace smoke detector with a functioning unit.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2021
Resolved 3 November 2021
Resolution: Smoke detector replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 October 2021 Resolved
Several life jackets were found to have worn/old retro reflective tape that no longer are effective. Replace retro reflective tape on those life jackets.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2021
Resolved 3 November 2021
Resolution: New retro reflective tape installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 November 2018 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 and arranged as specified by IMO Resolution A.658(16). Several life jackets had severely deteriorated retroreflective material.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 30 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 November 2018 Resolved
At least one life life buoy must be fitted with a lifeline meeting the requirements of 46 CFR 180.70(c). Vessel did not have required lifeline.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 28 November 2018
Resolution: Installed lifeline
10 - Safety of Navigation › N/A - No Subsystem › Compass correction log
Issued 16 November 2018 Resolved
Vessel is required to have a current magnetic compass deviation table or graph or compass comparison record for the steering compass, in the wheelhouse. Vessel's magnetic compass deviation table was last updated in 2010.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2018
Resolved 29 November 2018
Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 2 January 2018 Resolved
Emergency generator inoperative, repair generator to full capability and provide technician's report with problem and steps taken to rectify problem.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 January 2018
Resolved 2 January 2018
Resolution: Technician report received, def cleared vessel fit for service.
Lifesaving › Rescue Boat › Markings
Issued 3 November 2017 Resolved
Rescue boat marking missing from both sides of bow. Stencil the name of vessel and the number of persons capacity in clearly legible letters and numbers on each side othe bow of the rescue boat. 46 CFR 122.604.
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 14 December 2017
Resolution: Stenciled all required markings on rescue boat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 November 2016 Resolved
Vessel is past its Annual inspection 90 day window ending on 27 June 2016. Commence new COI inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 3 November 2016
Resolution: Vessel commenced new COI inspection.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 19 August 2016 Resolved
#2 Steering Gear room bilge alarm does not function. #2 Steering bilge shall be checked prior to departing docks on each run. Demonstrate bilge alarm to USCG inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2016
Resolved 9 November 2016
Resolution: Bilge alarm tested sat.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 August 2016 Resolved
Renew reflective tape on lifejackets designated during inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2016
Resolved 9 November 2016
Electrical › Electrical Distribution System (service) › Cable
Issued 19 August 2016 Resolved
Vessel has welding cable from pilothouse batteries to the main on/off switches. Renew with proper marine cable during next drydock in August 2018.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2018
Resolved 31 October 2018
Resolution: Cables replaced.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.