Records from 1994 to 2025. Most recent: inspection, 11 September 2025.
Inspection history · 101
11 September 2025
Annual Inspection · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8231961
12 February 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8078909
11 February 2025
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8082140
11 December 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8045329
1 November 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8028158
9 September 2024
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8045885
8 May 2024
Drydock Extension
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7908793
15 November 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7825845
3 June 2023
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7745721
19 May 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7692247
24 March 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7656797
1 March 2023
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7647961
31 January 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7636640
18 October 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7575044
28 May 2022
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7473853
12 May 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7449132
26 October 2021
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7340370
6 November 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7089699
6 October 2020
Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7076481
9 March 2020
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6923458
3 January 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6884560
1 November 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6841137
28 December 2018
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6603654
25 November 2018
Security Breach
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6685740
16 November 2018
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6581034
6 November 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6576823
6 November 2018
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6576869
7 September 2018
Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6535064
1 June 2018
In-Service Inspection · Drydock Extension · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6431711
10 April 2018
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6389439
27 March 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6443291
23 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6360382
2 January 2018
Damage Survey · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6331634
3 November 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6294890
19 August 2016
Deficiency Check · MTSA Verification · Underwater Inspection in lieu of Drydock · COI Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5977653
3 March 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5828244
14 November 2015
Administrative Inspection · Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5764845
30 October 2015
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5755879
10 August 2015
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5764628
13 July 2015
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5183652
8 August 2014
Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4948043
19 May 2014
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4862383
1 May 2012
Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4317918
6 December 2011
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4203161
6 October 2010
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3870769
30 January 2009
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3404043
7 November 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3362310
7 October 2008
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3335740
13 June 2008
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3229213
21 May 2008
Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3201201
29 February 2008
Internal Structural Exam · Drydock Extension
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3155834
6 April 2007
MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2896015
31 January 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2866007
24 October 2006
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2808136
26 September 2006
Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2789141
5 April 2006
Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2617765
30 August 2005
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2479683
27 August 2005
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2480300
8 August 2005
MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2455956
16 August 2004
MTSA Verification · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2228739
26 April 2004
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2051295
8 April 2004
Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2040114
30 March 2004
In-Service Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2033920
27 February 2004
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2017546
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1971508
23 June 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1825874
7 February 2003
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1741576
23 January 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1734360
21 October 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1719663
26 June 2002
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1637758
19 April 2002
Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1616375
12 January 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1482378
2 January 2002
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1474234
8 August 2001
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1068946
25 July 2001
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1070950
28 June 2001
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1067137
9 June 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 162435
9 June 2001
Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1436581
4 June 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1470317
1 August 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 822424
7 June 2000
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1401238
20 May 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 171527
2 June 1999
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1360923
12 May 1999
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 796149
24 June 1998
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1411702
7 May 1998
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1411697
6 June 1997
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1392704
26 March 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1465298
13 September 1996
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 956811
6 August 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 153920
18 July 1996
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1090639
12 June 1996
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1394566
3 May 1996
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1416301
11 August 1995
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 872403
13 July 1995
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1383007
10 January 1995
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 858127
30 November 1994
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 871550
27 October 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1450908
27 September 1994
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1179138
27 July 1994
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1180079
15 July 1994
Plan Review "T" Boat · Inclining Experiment · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1397982
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 11 December 2024
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Vessel #2 end void 3 ddx plug leaking, temp repaired with belzona. Vessel to affect permanent repairs as soon as able.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 January 2025
Resolved 3 January 2025
Resolution: Leaking docking plug welded shut as temporary repair until vessel goes to drydock in 2026 to conduct permanent repair.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 December 2024
No resolution recorded
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel to submit plans and make permanent repairs to area of hull where docking plug in #3 void on the #2 end was welded in place. Repairs to be completed at vessels next scheduled drydock in 2026.
46CFR115.700
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 May 2023
Resolved
1 service generator is inoperable
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2023
Resolved 19 May 2023
Resolution: Tech rep from Tacoma Diesel came and installed a new oil pressure swtich. Verified operation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 March 2023
Resolved
The main steering gear and rudder stock must be of adequate strength for and capable of steering the vessel at maximum ahead service speed, which must be demonstrated to the satisfaction of the cognizant Officer in Charge, Marine Inspection. Vessel operator reported loss of steering on the #2 rudder while vessel was underway. Provide tech report to include any repairs and complete sea trials prior to departure.
Cite: 46CFR119.600, 46CFR58.25-10
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2023
Resolution: MI received Hamilton Jet technician report and witnessed successful sea trials.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 January 2023
Resolved
Fire pump was leaking while running and has pinhole leak in casing. Pressure at pump was 22psi.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2023
Resolved 23 March 2023
Resolution: Vessel replaced fire pump and MI's observed successful test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 31 January 2023
Resolved
#1 MDE high temp alarm was disconnected and inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2023
Resolved 1 March 2023
Resolution: Vessel O/O corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 January 2023
Resolved
Nonconductive mats were missing in front of main switchboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2023
Resolved 1 March 2023
Resolution: Vessel O/O corrected
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 January 2023
Resolved
Sprinkler head on #2 end, outboard side of car lane 4 was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2023
Resolved 1 March 2023
Resolution: Vessel O/O corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 January 2023
Resolved
Vessel was unable to test bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2023
Resolved 23 March 2023
Resolution: MI's observed successful test
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 October 2022
Resolved
Vessel installed new motor starter and alarm panel without notifying CG. Alterations to machinery or equipment affecting the safety of the vessel must not be made without the approval of the cognizant [name withheld] plans to MSC and provide CG proof of plan approval.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2023
Resolved 19 January 2023
Resolution: MI's confirmed newly installed equp, was installed IAW MSC approved plans.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 18 October 2022
Resolved
A vessel must be operated in accordance with applicable laws and regulations in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Until MSC approval of newly installed systems, limit vessel speed to 5 KTS or less within 200 yards of dock if possible given the current and sea state.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2023
Resolved 19 January 2023
Resolution: MI's confirmed newly installed equp, was installed IAW MSC approved plans.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 October 2022
Resolved
The master of a vessel shall have examined the propulsion controls of the vessel prior to getting underway. Until MSC approval of newly installed systems, vessel must conduct visual and operational inspections of the motor starters prior to carriage of passengers and keep logs of such inspections ready and available to inspectors upon request.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2023
Resolved 19 January 2023
Resolution: MI's confirmed newly installed equp, was installed IAW MSC approved plans.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 12 May 2022
Resolved
See activity 7449132.
Repairs or alterations to the hull, machinery or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] damage and heavy corrosion in the bottom hull plating between frames 5-7 reported to USCG by operator, shall be repaired at at next scheduled dry dock due NLT OCT 31, 2022. Prior to starting repairs, a proposed repair plan shall be submitted to the local OCMI for approval.
46 CFR 115.700
Action required: 705 - Other - as specified
Due 31 October 2022
Resolved 1 December 2022
Resolution: Resolved during DDX, MISLE case 7575044.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2021
Resolved
Several ring buoys were found to have faded markings. Replace/restore markings on ring buoys.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2021
Resolved 3 November 2021
Resolution: Ring buoys markings restored.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2021
Resolved
Signage on fire extinguisher enclosures that describes how to open enclosure has faded. Restore or replace signage.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2021
Resolved 3 November 2021
Resolution: Signage restored.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2021
Resolved
#1 steering compartment has a broken bracket that is supposed to support deck plating in this space. As a regularly checked space, crew is suseptible to injury from stepping on decking when conducting their checks and maintenance. Repair bracket within 30 days.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2021
Resolved 18 November 2021
Resolution: Bracket has been welded and secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2021
Resolved
Women's head smoke detector broken/does not pass smoke test. Replace smoke detector with a functioning unit.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2021
Resolved 3 November 2021
Resolution: Smoke detector replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 October 2021
Resolved
Several life jackets were found to have worn/old retro reflective tape that no longer are effective. Replace retro reflective tape on those life jackets.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2021
Resolved 3 November 2021
Resolution: New retro reflective tape installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 November 2018
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 and arranged as specified by IMO Resolution A.658(16). Several life jackets had severely deteriorated retroreflective material.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 30 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 November 2018
Resolved
At least one life life buoy must be fitted with a lifeline meeting the requirements of 46 CFR 180.70(c). Vessel did not have required lifeline.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 28 November 2018
Resolution: Installed lifeline
10 - Safety of Navigation › N/A - No Subsystem › Compass correction log
Issued 16 November 2018
Resolved
Vessel is required to have a current magnetic compass deviation table or graph or compass comparison record for the steering compass, in the wheelhouse. Vessel's magnetic compass deviation table was last updated in 2010.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2018
Resolved 29 November 2018
Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 2 January 2018
Resolved
Emergency generator inoperative, repair generator to full capability and provide technician's report with problem and steps taken to rectify problem.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 January 2018
Resolved 2 January 2018
Resolution: Technician report received, def cleared vessel fit for service.
Lifesaving › Rescue Boat › Markings
Issued 3 November 2017
Resolved
Rescue boat marking missing from both sides of bow. Stencil the name of vessel and the number of persons capacity in clearly legible letters and numbers on each side othe bow of the rescue boat. 46 CFR 122.604.
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 14 December 2017
Resolution: Stenciled all required markings on rescue boat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 November 2016
Resolved
Vessel is past its Annual inspection 90 day window ending on 27 June 2016. Commence new COI inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 3 November 2016
Resolution: Vessel commenced new COI inspection.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 19 August 2016
Resolved
#2 Steering Gear room bilge alarm does not function. #2 Steering bilge shall be checked prior to departing docks on each run. Demonstrate bilge alarm to USCG inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2016
Resolved 9 November 2016
Resolution: Bilge alarm tested sat.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 August 2016
Resolved
Renew reflective tape on lifejackets designated during inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2016
Resolved 9 November 2016
Electrical › Electrical Distribution System (service) › Cable
Issued 19 August 2016
Resolved
Vessel has welding cable from pilothouse batteries to the main on/off switches. Renew with proper marine cable during next drydock in August 2018.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2018
Resolved 31 October 2018
Resolution: Cables replaced.
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 August 2015
Resolved
Crew found small hole on discharge side of raw water colling system for engine and reduction gear, allowing water to enter the engine room.
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 29 February 2016
Resolution: Verified the condition of permanent repairs to the cooling water system.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (electric)
Issued 10 July 2015
Resolved
# 2 Generator OOC due to bad starter. Prove operation of # 2 generator.
Due 17 July 2015
Resolved 14 July 2015
Resolution: Contractor Brendan Diesel removed broken starter and replaced with new starter on the morning of Tuesday July 14th. Operational tests successful.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 7 October 2008
Resolved
Recoat both shafts fiber glass protective coatings.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 October 2008
Resolved 20 October 2008
Engineering › Steering Gear System › Rudder Stock
Issued 7 October 2008
Resolved
Straighten bent #1 rudder stock.
Action required: 705 - Other - as specified
Due 20 October 2008
Resolved 20 October 2008
Construction/Loadline › Penetrations › Pipe Flange
Issued 13 June 2008
Resolved
Renew both #1 and 2 main engine S/W overboard hull connections.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 10 October 2008
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 21 May 2008
Resolved
Clean out 4 clogged sprinkler heads.
Due 15 June 2008
Resolved 13 June 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 May 2008
Resolved
Replace missing cover of emergency light and alarm light in #1 end of the engine room.
Due 15 June 2008
Resolved 13 June 2008
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 May 2008
Resolved
Ensure all lifebuoys are properly marked.
Due 15 June 2008
Resolved 13 June 2008
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 21 May 2008
Resolved
Demonstrate proper operation of low lube oil alarm, high temp alarm, and overspeed trips on main engines and generators to the satisfaction of the USCG inspector. Presently alarms are not indicating at all or are indicating for the wrong engine. Provide engineer to man engine room while underway until alarms are repaired.
Due 15 June 2009
Resolved 30 January 2009
Resolution: Tested alarms and indicators all sat.
Engineering › Pressure Vessel › Marking and Stamping
Issued 21 May 2008
Resolved
Hydrostatically test 3 pressure vessels listed on COI.
Due 15 June 2008
Resolved 13 June 2008
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 6 April 2007
Resolved
9 sprinkler heads were not operable.
Action required: 705 - Other - as specified
Resolved 6 April 2007
Resolution: Proved sprinkler heads were operable
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 September 2006
Resolved
Emergency lighting in engine room failed to operate properly.
Action required: 705 - Other - as specified
Due 27 September 2006
Resolved 27 September 2006
Resolution: Crew changed out 3 light bulbs and 1 light fixture in engine room.
Engineering › Generator (propulsion/auxiliary-electric) › Circuit Board
Issued 26 September 2006
Resolved
Alarms for both electrical generators failed to alarm during operational tests.
Due 22 December 2006
Resolved 1 February 2007
Resolution: Determined that vessel is an existing vessel and this requirement was given in error.
Engineering › Steering Gear System › Valve, Control
Issued 30 August 2005
Resolved
Lock valve on steering system #1 end not operating properly causing steering ineffective.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2005
Resolved 30 August 2005
Resolution: Replaced lock valve, oil and filter tested satisfactory.
Lifesaving › Buoyant Apparatus
Issued 27 February 2004
Resolved
Vessel route limited to no more than one mile from land untill all primary lifesaving equipment (inflatable buoyant aparratus) required by its COI are on board the vessel.
Action required: 705 - Other - as specified
Due 29 March 2004
Resolved 29 March 2004
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 2 January 2002
Resolved
Establish written instructions for the securing of the passenger elevator during layup periods that will prevent the possibility of someone being trapped.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 16 January 2002
Resolution: Recieved copy of " SECURING THE ELEVATOR" procedures from the vessels operator, Pacific Western Maritime, Inc.
Fire Fighting
Issued 25 July 2001
Resolved
CLEAN VEHICLE DECK SPRINKLER HEADS IN WAY OF #1 END PORT OUTBOARD FORWARD; AND, IN WAY OF #2 END PORT FORWARD OUTBOARD SECOND AFT.
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Fire Fighting
Issued 4 June 2001
Resolved
CLEAN VEHICLE DECK SPRINKLER HEADS.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Engineering
Issued 4 June 2001
Resolved
REPAIR OR REPLACE AND DEMONSTRATE PROPER OPERATION OF ENGINE ROOM ALARM PANEL. UNTIL THIS REQUIREMENT IS SATISFIED, ENGINE ROOM IS TO BE MANNED. WHEN THE NUMBER OF PASSENGERS ON BOARD EXCEEDS 149, AN ADDITIONAL DECKHAND SHALL BE PROVIDED FOR A TOTAL OF 4 DECKHANDS.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Electrical
Issued 12 June 1996
Resolved
PLACE ELECTRICAL INSULATING MATTING ON DECK BEHIND ELECTRICAL DISTRIBUTION PANEL IN ENGRM.
Condition: Unknown
Due 21 June 1996
Resolved 8 July 1996
Lifesaving
Issued 12 June 1996
Resolved
REPLACE LANYARD FOR WATERLIGHT ON PILOTHOUSE RING BUOY. EXISTING LANYARD ISTOO SHORT & DETERIORATED.
Condition: Unknown
Due 21 June 1996
Resolved 8 July 1996
Lifesaving
Issued 12 June 1996
Resolved
PROVIDE PROPER NUMBER OF LIFE PRESERVERS REQUIRED ONBD.
Condition: Unknown
Due 12 June 1996
Resolved 8 July 1996
Fire Fighting
Issued 12 June 1996
Resolved
PROVIDE PROOF OF SERVICING OF INSTALLED FIREFIGHTING SYSTEM & PORTABLE EXTINGUISHERS.
Condition: Unknown
Due 21 June 1996
Resolved 8 July 1996
Engineering
Issued 12 June 1996
Resolved
REPAIR OR REPLACE JOHN CRANE STERN TUBE SEAL THAT IS EXCESSIVELY LEAKING ATNO. 2 END. UNTIL CORRECTED, INSPECT CONDITION EVERY 30 MINS, PUMP AS NECESSARY, & PREPARE AIRLINE & HARDWARE TO INFLATE EMERGENCY BOOT IN EVENT OF FAILURE.
Condition: Unknown
Due 21 June 1996
Resolved 8 July 1996
Lifesaving
Issued 12 June 1996
Resolved
PROVIDE WATERTIGHT, BRIGHTLY COLORED LOCKER FOR SIGNALLING DEVICES.
Condition: Unknown
Due 21 June 1996
Resolved 8 July 1996
Lifesaving
Issued 12 June 1996
Resolved
DEMONSTRATE PROPER OPERATION OF RESCUE BOAT RELEASING GEAR IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 21 June 1996
Resolved 8 July 1996
Accommodation/Occupational Safety
Issued 12 June 1996
Resolved
PROPERLY LABEL EMERGENCY ESCAPES FROM ENGRM.
Condition: Unknown
Due 21 June 1996
Resolved 8 July 1996
Electrical
Issued 13 July 1995
Resolved
PROVIDE BLANK CIRCUIT BREAKERS FOR BREAKERS #20 THROUGH #30 ON DISTRIBUTIONPANEL MP-3P-P1 LOCATED IN THE ENGINE ROOM.
Condition: Unknown
Due 28 July 1995
Resolved 14 August 1995
Construction/Loadline
Issued 13 July 1995
Resolved
PROVIDE RETAINING DEVICES FOR ALL MAINDECK HATCHES.
Condition: Unknown
Due 28 July 1995
Resolved 14 August 1995
Lifesaving
Issued 13 July 1995
Resolved
SECURE GRAPPLING HOOK ON CAR DECK.
Condition: Unknown
Due 28 July 1995
Resolved 14 August 1995
Lifesaving
Issued 13 July 1995
Resolved
DEMONSTRATE OPERATION OF VESSEL'S AUTOMATION SYSTEM.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Lifesaving
Issued 13 July 1995
Resolved
GREASE ALL CAR DECK LIFE PRESERVER RELEASING HATCHES.
Condition: Unknown
Due 28 July 1995
Resolved 14 August 1995
Lifesaving
Issued 13 July 1995
Resolved
MARK ALL PFD'S WITH VESSELS NAME.
Condition: Unknown
Due 14 August 1995
Resolved 14 August 1995
Documentation
Issued 13 July 1995
Resolved
PROVIDE DOCUMENTATION FOR DRUG SCREENING POLICY.
Condition: Unknown
Due 14 August 1995
Resolved 1 August 1995
Electrical
Issued 13 July 1995
Resolved
INSTALL BLANK IN ELECTRICAL PANEL MP-3P-P-2.
Condition: Unknown
Due 28 July 1995
Resolved 14 August 1995
Navigation
Issued 13 July 1995
Resolved
PROVE OPERATION OF RELIEF VALVES INSTALLED ON THE THREE AIR RECEIVERS LOCATED IN THE ENGINE ROOM.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Accommodation/Occupational Safety
Issued 13 July 1995
Resolved
REPAIR WASHBASINS IN MEN'S BATHROOM.
Condition: Unknown
Due 14 August 1995
Resolved 14 August 1995
Construction/Loadline
Issued 13 July 1995
Resolved
MAKE MAIN DECK HATCH FOR VOID LOCATED AT FRAMES 23-29 WATERTIGHT.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Electrical
Issued 13 July 1995
Resolved
DEMONSTRATE OPERATION OF NAVIGATION LIGHT ALARM PANEL.
Condition: Unknown
Due 14 August 1995
Resolved 14 August 1995
Lifesaving
Issued 13 July 1995
Resolved
PROVIDE PLAN TO UPGRADE RESCUE BOAT OPERATION (DAVIT SYSTEM CURRENTLY PROVIDES NO SAFETY SYSTEMS FOR OPERATOR FROM FALLING OVERBOARD AND NO MEANSTO BRING ABOARD AN INJURED OR HYPOTHERMIC VICTIM SATISFACTORILY)
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Engineering
Issued 13 July 1995
Resolved
REMOVE EXCESS FUEL LOCATED IN BUCKET UNDER #1 GENERATOR F/O FILTER.
Condition: Unknown
Due 14 July 1995
Resolved 14 August 1995
Construction/Loadline
Issued 13 July 1995
Resolved
SERVICE THE MAIN SHAFT PACKING GLAND LOCATED AT THE #1 END.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Engineering
Issued 27 October 1994
Resolved
EXCEPT IN AN EMERGENCY SITUATION, DO NOT EXCEED 250 SHAFT RPM'S PULL AND 300 SHAFT RPM'S PUSH UNTIL SYSTEM IS DEMONSTATED TO OPERATE PROPERLY IN A CRASH STOP SITUATION.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Accommodation/Occupational Safety
Issued 27 October 1994
Resolved
MAKE MODIFICATIONS FOR STAIRWAYS TO ENSURE PASSENGER SAFETY WHEN WET.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Accommodation/Occupational Safety
Issued 27 October 1994
Resolved
PROVIDE PROOF OF SERVICING AND PROVE PROPER OPERATION OF PASSENGER_x001C_ ELEVATOR.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Navigation
Issued 27 October 1994
Resolved
MAKE OPERATIONAL THE LIGHTS FITTED ON EACH MAGNETIC COMPASS.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Navigation
Issued 27 July 1994
Resolved
PROVIDE CURRENT CHARTS FOR AREA OF OPERATION.
Condition: Unknown
Due 27 July 1994
Resolved 27 July 1994
Navigation
Issued 27 July 1994
Resolved
PROVIDE PUBLICATIONS AS FOLLOWS: 1). 46 CFR PARTS 1-199 2). RULES OF THEROAD.
Condition: Unknown
Due 27 July 1994
Resolved 27 July 1994
Fire Fighting
Issued 27 July 1994
Resolved
PROVIDE APPROVED PLANS FOR FIXED CO2 SYSTEM IN ENGINE ROOM.
Condition: Unknown
Due 27 July 1994
Resolved 27 July 1994
Accommodation/Occupational Safety
Issued 27 July 1994
Resolved
SECURELY MOUNT HYDRAULIC HOSE IN ELEVATOR MACHINERY SPACE FROM ANY MOVEMENTOR CHAFING.
Condition: Unknown
Due 27 July 1994
Resolved 27 July 1994
Navigation
Issued 27 July 1994
Resolved
PROVIDE COMPASS DEVIATION TABLE FOR BOTH BRIDGE COMPASSES. COMPASS MAY NEED TO BE MOVED AWAY FROM FORWARD BULKHEAD SO STEEL WILL NOT AFFECT THE SWING.
Condition: Unknown
Due 27 July 1994
Resolved 27 July 1994
Engineering
Issued 27 July 1994
Resolved
PROVE PROPER OPERATION OF HIGH TEMP ALARM ON #2 MDE.
Condition: Unknown
Due 27 July 1994
Resolved 27 July 1994
Lifesaving
Issued 15 July 1994
Resolved
PROPERLY MOUNT AND STENCIL RING BUOYS.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Engineering
Issued 15 July 1994
Resolved
PROPERLY LABEL F.O. SHUT OFF REACH RODS AND DIRECTION OF CLOSURE.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Documentation
Issued 15 July 1994
Resolved
PROVIDE ON BOARD PERMANENT FCC RADIO STATION LICENSE.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Electrical
Issued 15 July 1994
Resolved
PROVIDE GFI OUTLETS IN BOTH HEADS AND METAL COVERS FOR E/R OUTLETS.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Engineering
Issued 15 July 1994
Resolved
PROVE PROPER OPERATION OF M/E'S AND S/S GENERATOR'S LOW LUBE OIL AND HIGH WATER TEMP. ALARMS.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Engineering
Issued 15 July 1994
Resolved
PROVIDE GUARDS ON S/S GENERATOR FRONTS
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Fire Fighting
Issued 15 July 1994
Resolved
PROVIDE GUARDS OVER CO2 RELEASE HANDLES IN CO2 ROOM.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Fire Fighting
Issued 15 July 1994
Resolved
PROVIDE INSTRUCTION PLACARDS FOR CO2 RELEASES.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Documentation
Issued 15 July 1994
Resolved
PROVIDE ON BOARD ORIGINAL STABILITY LETTER.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Fire Fighting
Issued 15 July 1994
Resolved
PROVIDE APPROVED DRAWING, MILL CERTS AND BILL OF MATERIALS FOR CO2 SYSTEM PIPING.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Lifesaving
Issued 15 July 1994
Resolved
PROPERLY INSTALL BUOYANT APPARATUS SEA PAINTER.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Lifesaving
Issued 15 July 1994
Resolved
PROVIDE A NO LOAD RELEASE HOOK FOR RESCUE BOAT.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Accommodation/Occupational Safety
Issued 15 July 1994
Resolved
PROVIDE PROPER LENGTH OF HOSE < 30" (76.2CM) ON ELEVATOR HYDRAULICS.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Navigation
Issued 15 July 1994
Resolved
PROVIDE ON BOARD ALL APPLICABLE CHARTS AND PUBS AS REQUIRED BY LOCAL OCMI.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Accommodation/Occupational Safety
Issued 15 July 1994
Resolved
TO THE SATISFACTION OF AN ATTENDING INSPECTOR PROVE ALL REQUIRED STENCILS, LABELS AND PLACARDS.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Fire Fighting
Issued 15 July 1994
Resolved
TO THE SATISFACTION OF AN ATTENDING INSPECTOR, PROVE PROPER INSTALLATION OFSTRUCTURAL FIRE PROTECTION INSULATION IN ACCORDANCE WITH APPROVED DRAWINGS.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Fire Fighting
Issued 15 July 1994
Resolved
TO THE SATISFACTION OF AN ATTENDING INSPECTOR, PROVE THE PROPER INSTALLATION OF ALL FIRE STOP WIRE RACE WAYS.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Documentation
Issued 15 July 1994
Resolved
PROVIDE ON BOARD A COPY OF APPROVED FUEL OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Construction/Loadline
Issued 15 July 1994
Resolved
PROVIDE HANGERS FOR DECK HATCH WRENCHES.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Lifesaving
Issued 15 July 1994
Resolved
PROVIDE PLACARD FOR RESCUE BOAT STATING THAT PERSONNEL SHOULD BE CENTERED IN BOAT AND REMAIN SEATED DURING RAISING AND LOWERING OF RESCUE BOAT.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Electrical
Issued 15 July 1994
Resolved
FIND AND ELIMINATE ELECTRICAL SYSTEM GROUND FAULT
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Navigation
Issued 15 July 1994
Resolved
PROVIDE VALID COMPASS DEVIATION CARD.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Navigation
Issued 15 July 1994
Resolved
SHOW PROPER OPERATION OF # 1 END SHIP'S WHISTLE.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Engineering
Issued 15 July 1994
Resolved
PROVIDE AU-1 FORM FOR AIR RECEIVER'S AND HAVE ATTENDING INSPECTOR MARK A/R'S WITH PROPELLER STAMP.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Engineering
Issued 15 July 1994
Resolved
DEMONSTRATE OPERATION OF ALL AIR RECEIVER RELIEF VALVES.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994