Records from 1999 to 2003. Most recent: inspection, 31 January 2003.
Inspection history · 10
31 January 2003
Ballast Water Examination · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1738086
30 January 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1737811
30 January 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1779243
20 November 2002
Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1707627
3 April 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1600827
4 February 2002
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1483245
19 August 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 293025
21 June 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 720068
2 June 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 212700
1 June 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 429249
Engineering › Sea-water System (primary cooling) › Piping
Issued 31 January 2003
No resolution recorded
Salt water inlet to the main engine cooling has temporary patch.
Action required: 705 - Other - as specified
Due 1 March 2003 — due date passed with no resolution recorded
Construction/Loadline › Hull
Issued 31 January 2003
Resolved
Forepeak tank, port side, has shell plating and internals indented and fractured approximately 3 meters above bottom at frame 130, running vertically. The transverse underdeck stiffener below stringer is distorted and fractured. See attached Form B to NEWMS activity #1738086. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 1 February 2003
Resolution: Received class report from Lloyd''''''''s Register satisfying requirement.
Navigation › Emergency Steering
Issued 20 November 2002
Resolved
Steering failure audible/visual alarm on bridge is inoperative. LEGACY COMPONENT DESC: Communications to Emergency Steering
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2002
Resolution: Steering failure audible/visible alarm on bridge is operational.
Pollution Prevention/Response › Prevention Equipment
Issued 20 November 2002
Resolved
OWS not functioning properly. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2002
Resolution: OWS functioning properly.
Electrical
Issued 1 June 1999
Resolved
EMERGENCY GENERATOR INOP. REPAIR OR REPLACE (CLASS RPT REQUIRED)
Condition: Unknown
Due 1 June 1999
Resolved 3 June 1999
Electrical
Issued 1 June 1999
Resolved
MAIN SWITCHBOARD BREAKERS MISSING/ SWB INOP (CLASS RPT REQUIRED)
Condition: Unknown
Due 1 June 1999
Resolved 3 June 1999
Electrical
Issued 1 June 1999
Resolved
LIGHT COVERS MISSING IN ENGINE ROOM
Condition: Unknown
Due 19 August 2001
Resolved 19 August 2001
Electrical
Issued 1 June 1999
Resolved
NO ELECTRICAL MATTING IN FROUNT OF SWITCHBOARD
Condition: Unknown
Due 19 August 2001
Resolved 19 August 2001
Fire Fighting
Issued 1 June 1999
Resolved
AUTO CLOSURES WERE REMOVED FROM E/ROOM DOORS
Condition: Unknown
Due 19 August 2001
Resolved 19 August 2001