MAURY USCG vessel records Sign in
← All vessels

MS D

MS D is a 1980 offshore supply vessel. The Coast Guard has recorded 57 inspections since 1981, most recently in January 2009, along with 44 deficiencies.

Records from 1981 to 2009. Most recent: inspection, 29 January 2009.

Built
1980
Last inspected
29 January 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB2534
Flag
UNITED STATES
366817560, 366876970 (licence lapsed)
Maury page id
psix-52314

Inspections, by type

…with no type recorded20
Years with a record 29 calendar years (1981–2009)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Net Ton
98 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB2534MMSI 366876970 · expired · compulsorily equipped · granted 18 December 2002, cancelled 23 February 2013
WDA5202MMSI 366817560 · cancelled · compulsorily equipped · granted 6 July 2001, cancelled 31 July 2006 · licensed under a name not among this hull’s recorded names (not shown)
WCV8520MMSI not assigned · expired · compulsorily equipped · granted 7 July 1999, cancelled 1 April 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CHRISTOS Freight Ship · MISLE 398583 · 30 January 2003 · activity 1779243

Inspection history · 57

29 January 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3397582
2 August 2008 Type not recorded
No type recorded · USCGC POMPANO (WPB 87339) · USCG East District (CGD-E) · Activity 3287304
12 December 2007 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3115530
8 February 2006 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2581489
7 October 2005 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2509640
15 December 2004 Re-Inspection · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2256378
4 February 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2003155
30 January 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1779243
14 November 2002 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1705313
16 May 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366377
9 February 2000 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458714
26 April 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453603
18 December 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 516123
12 October 1998 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 801497
15 June 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 93239
4 June 1998 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1131489
1 June 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 124737
22 April 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 766591
13 March 1998 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426058
16 January 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 203335
16 October 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1111381
17 September 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 773786
18 February 1997 COI Inspection · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416451
13 January 1997 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416422
12 January 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 115867
12 January 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 220983
12 January 1997 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1398607
25 July 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1089514
21 April 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 11998
10 April 1996 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1083630
26 February 1996 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383137
20 December 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1182698
18 December 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 883447
15 March 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 135527
20 December 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355042
21 December 1993 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438126
18 March 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 3636
15 December 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444691
27 October 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 43588
12 December 1991 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1258719
17 June 1991 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1348024
19 March 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1233120
4 December 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241793
31 January 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234579
4 December 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1219294
25 September 1989 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1321754
7 December 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899035
30 March 1988 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1033100
10 December 1987 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1322833
22 September 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318024
9 December 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310649
19 March 1986 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306596
9 December 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293598
7 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284271
23 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283365
5 November 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968510
22 October 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274083

Deficiency record · 44

Stability › Watertight Integrity › General
Issued 29 January 2009 Resolved
Renew gaskets to engine room, parlor, and galley space and properly adjust watertight doors. This deficiency has shown up over last 3 inspections (2006, 2007, 2009).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2009
Documentation › Logs/Records › Logbook (official)
Issued 29 January 2009 Resolved
Logs not properly filled out iaw 46 USC. Pre-underway checklists not completed prior to vessel's departure.
Action required: 705 - Other - as specified
Due 30 January 2010
Resolved 24 May 2010
Documentation › Logs/Records › Logbook (official)
Issued 29 January 2009 Resolved
Properly fill out drills in official logbook. 08 drills conducted since last inspection in December 2007. Conduct 6 drills (3 fire drills- engine room/galley/deck, 1 abandon ship drill, 1 man overboard drill, and 1 hotwash of previous drills). Properly log drills in logbook.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2009
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 29 January 2009 Resolved
Passenger lists not kept by vessel. Create Passenger/Crew list for vessel.
Action required: 705 - Other - as specified
Resolved 30 January 2009
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 29 January 2009 Resolved
Lifesaving maintenance records not kept. Properly fill out maintenance records for lifesaving equipment iaw manufacturers instructions.
Action required: 705 - Other - as specified
Due 30 January 2010
Resolved 24 May 2010
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 29 January 2009 Resolved
Alcohol swabs not on board. Vessel was boarded by CG in August due to erratic vessel manuvering and required crew to use swabs. Swabs not replaced by vessel owners.
Action required: 705 - Other - as specified
Resolved 30 January 2009
Lifesaving › Lifefloat › Serviceable
Issued 29 January 2009 Resolved
Lifefloats in deteriorated condition. Require vessel service/replace lifefloats. Additionally, previous inspection required stenseling of vessel name on underside of lifefloat. Stenseling was not completed prior to this inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2009
Lifesaving › Lifefloat › Markings
Issued 12 December 2007 Resolved
Vessel name needs to be stenciled on the underside of the life floats and touched up on the life rings.
Due 12 January 2008
Resolved 30 January 2009
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 12 December 2007 Resolved
Draft marks need to be painted on the hull fore and aft.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 December 2007 Resolved
Replace old first aid kit with CG approved kit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2009
Resolution: New first aid kit installed.
Stability › Watertight Integrity › General
Issued 12 December 2007 Resolved
Repair water tight doors from Main deck to Salon area and from Salon into the galley to ensure proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2007
Resolution: Resolved by last inspection team (see thier narrative).
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 12 December 2007 Resolved
SSB not working properly during test. Correct and prove ability to transmit and receive traffic on 2182.0
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2007
Resolution: operation demonstrated with a radio check
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 12 December 2007 Resolved
Freezer on 2nd deck not installed properly. Either remove or mount properly and wire correctly into ships service system.
Condition: Improper Installation
Due 12 January 2008
Resolved 13 December 2007
Resolution: Freezer removed from vessel
Electrical › Lighting (service) › Lighting Fixture
Issued 12 December 2007 Resolved
Replace light bulb in crew berthing with working one.
Due 12 January 2008
Resolved 12 December 2007
Resolution: Light replaced prior to end of inspection
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 12 December 2007 Resolved
Bilges had water and oily mixtures in them. These need to be removed so that the bottom of the bilge can be seen.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2007
Resolution: Bilges pumped out into dirty oil tank.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 12 December 2007 Resolved
Crew couldn't demonstrate proper operation of overspeed devices or switchboard operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2007
Resolution: Overspeed devices were adjusted to trip and engineer demonstrated proper switchboard usage.
Engineering › Fuel Oil Service System › Hose
Issued 12 December 2007 Resolved
Fuel return hose was leaking on starboard generator
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2007
Resolution: Fuel line was fixed, no more leaks evident during operation.
Engineering › Fuel Oil Service System › Filter
Issued 12 December 2007 Resolved
Install metal shields on both generator fuel filters.
Due 12 January 2008
Resolved 30 January 2009
Accommodation/Occupational Safety › Potable Water System › General
Issued 12 December 2007 Resolved
Repair corroding elbow in potable water system where weld has a hole in it.
Due 12 January 2008
Resolved 13 December 2007
Resolution: Elbow weld was gouged and rewelded.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 12 December 2007 Resolved
Vessel needed 2 dry chem and 1 5-gal AFFF container on board to be in compliance with 49 CFR 176.315 for MPT carriage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2007
Resolution: Equipment on board and mounted.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 12 December 2007 Resolved
Emergency Escape Scuttle not marked.
Due 12 January 2008
Resolved 13 December 2007
Resolution: Scuttle stenciled with black paint.
Deck/Cargo › Ballast › Vents
Issued 12 December 2007 Resolved
Didn't have plugs for ballast tank vents
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2007
Resolution: Plugs were attached to each vent.
Lifesaving › Lifefloat › Serviceable
Issued 12 December 2007 Resolved
Spacer was not provided between the two lifefloats and needs to be added.
Due 12 January 2008
Resolved 29 January 2009
Resolution: Spacers added.
Fire Fighting › Fire Main › Material
Issued 12 December 2007 Resolved
Repair leaks on firemain piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2007
Resolution: Spool flange bolts were tightened and tested to inspector''s satisfaction.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 12 December 2007 Resolved
Emergency Escape not labeled in E/R
Due 12 January 2008
Resolved 29 January 2009
Resolution: Marked from deck and in E/R.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 12 December 2007 Resolved
Reroute washing machine drain currently going into bilges.
Due 12 January 2008
Resolved 29 January 2009
Resolution: Piped into sewage tank.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 December 2007 Resolved
Remove fixture in between main engines or put a bulb and cover on it.
Due 12 January 2008
Resolved 13 December 2007
Resolution: It was an old fixture and removed from the engine room.
Stability › Watertight Integrity › General
Issued 12 December 2007 Resolved
Label E/R doors to keep close when u/w at all times.
Due 12 January 2008
Resolved 13 December 2007
Resolution: Labling put on all doors in the e/r.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 8 February 2006 Resolved
Paint draft marks.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2006
Resolved 9 February 2006
Resolution: Painted draft marks.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 8 February 2006 Resolved
Renew and demonstrate proper operation of engine room escape hatch.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2006
Resolved 9 February 2006
Resolution: Replaced engine room escape hatch.
Deck/Cargo › Holds/Tanks › Coaming
Issued 8 February 2006 Resolved
Demonstrate proper operation of two water tight doors.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2006
Resolved 9 February 2006
Resolution: Repaired water tight doors (2).
Accommodation/Occupational Safety › Potable Water System › General
Issued 8 February 2006 Resolved
Install screen on potable water vent.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2006
Resolved 9 February 2006
Resolution: Installed screen on potable water vent.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 8 February 2006 Resolved
Demonstrate proper operation of SSB.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2006
Resolved 9 February 2006
Resolution: Demonstrated proper operation of SSB.
Engineering › Steering Gear System › Pump
Issued 22 January 2003 Resolved
PORT STEERING PUMP INOPERABLE.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2003
Resolved 24 January 2003
Resolution: REPAIRED PUMP/MOTOR ASSEMBLY.
Communications › Radio Communications › EPIRB
Issued 22 January 2003 Resolved
PROVIDE EPIRB REGISTRATION.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2003
Resolved 24 January 2003
Resolution: EPIRB REGRISTRATION PROVIDED.
Fire Fighting › Fire Pumps › Capacity
Issued 22 January 2003 Resolved
PROVIDE OPERATIONAL FIRE PUMP.
Action required: 705 - Other - as specified
Due 22 February 2003
Resolved 24 January 2003
Resolution: NEW FIRE PUMP PROVIDED AND TESTED TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Communications › Internal Communications System
Issued 22 January 2003 Resolved
PROVIDE PA SPEAKER IN LOWER BUNK ROOM. LEGACY COMPONENT DESC: PA SPEAKER
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2003
Resolved 24 January 2003
Engineering › Fuel Oil Service System › Hose
Issued 22 January 2003 Resolved
RENEW ALL FUEL HOSES ON BOTH MAIN ENGINES, SUPPLY AND RETURN.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2003
Resolved 24 January 2003
Lifesaving › Launching Appliances
Issued 22 January 2003 Resolved
PROVIDE STOKES LITTER TO RESCUE INJURED PERSON FROM WATER AS PER 8TH DISTRICT POLICY. LEGACY COMPONENT DESC: STOKES LITTER
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2003
Resolved 24 January 2003
Resolution: VESSEL PROVIDED STOKES LITTER BASKET AND J-BAR FOR LIFTING STOKES LITTER.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 22 January 2003 Resolved
PROVIDE REFUSE LOG.
Action required: 705 - Other - as specified
Due 22 February 2003
Resolved 24 January 2003
Resolution: REFUSE LOG PROVIDED.
Documentation › Logs/Records › Logbook (official)
Issued 22 January 2003 Resolved
PROVIDE RADIO LOGBOOK.
Action required: 705 - Other - as specified
Due 22 February 2003
Resolved 24 January 2003
Resolution: RADIO LOGBOOK PROVIDED.
Construction/Loadline
Issued 13 January 1997 Resolved
WORK IN THE M AND O INDUSTRY AND PASSENGERS ARE ALLOWED. AFFECT REPAIRS TOPORT FOREPEAK AND BULWARK AS ORIGINAL. REPAIRS TO BE CONDUCTED TO THE SATISFACTION OF AN ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 13 January 1997
Resolved 13 January 1997
Construction/Loadline
Issued 12 January 1997 Resolved
REPAIR DAMAGE TO PORT BOW AS ORIGINAL. VSL TO PROCEED TO FRESH WATER CITY TO AFFECT REPAIRS. REPAIRS TO BE CONDUCTED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR, PRIOR TO NEXT CARGO OPS OR CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 12 January 1997
Resolved 12 January 1997
Documentation
Issued 26 February 1996 Resolved
PROVIDE ONBOARD A VALID FCC SAFETY RADIOTELEPHONY CERTIFICATE PER 47 CFR 80.903 NLT 26APR96.
Condition: Unknown
Due 26 February 1996
Resolved 26 February 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.