MAURY USCG vessel records Sign in
← All vessels

SENANG SPIRIT

SENANG SPIRIT is a 1994 tank ship. The Coast Guard has recorded 40 inspections since 1994, most recently in December 2009, along with 4 deficiencies and 7 operational controls.

Records from 1994 to 2009. Most recent: inspection, 29 December 2009.

Built
1994
Last inspected
29 December 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9041382 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
399099
Flag
BAHAMAS, THE
—
Maury page id
psix-399099

Inspections, by type

…with no type recorded22
Years with a record 13 calendar years (1994–2009)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it111561 - Displacement, Ton
95649 - Dead Weight, Ton
52508 - Convention (Subpart B), Gross Ton
28208 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

JOSEPH W CARL Towing Vessel · MISLE 178304 · 23 January 2001 · activity 21499OR 3988 Freight Barge · MISLE 202630 · 23 January 2001 · activity 21499

Inspection history · 40

29 December 2009 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3656415
22 December 2009 COE-Offshore
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3653994
22 June 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2970008
30 January 2007 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2863838
30 January 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2863957
7 October 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2797173
1 July 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2697384
22 June 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2688044
23 March 2006 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2607933
7 March 2006 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2597603
24 January 2006 Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2572130
14 December 2005 Type not recorded
No type recorded · Vessel Traffic Service Houston-Galveston · USCG Heartland District (CGD-H) · Activity 2551044
9 December 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2548831
23 July 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2439483
21 July 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2435150
26 May 2005 ISPS II Exam
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2363555
25 January 2005 COC-TVE Renew · ISPS III Exam
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2280620
24 January 2005 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2280309
6 May 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2060649
29 April 2004 MTSA/ISPS Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2056305
10 April 2004 MTSA/ISPS Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2041675
3 March 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2018229
31 January 2004 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1998316
26 July 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1857465
11 June 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1814876
29 January 2003 Certificate of Compliance
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1737935
1 July 2001 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 291352
23 January 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 21499
7 July 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 279545
5 July 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 430205
13 January 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 445099
24 June 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 416842
23 June 1998 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1419958
18 January 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 399710
18 January 1997 Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1383428
7 September 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 382388
17 January 1995 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 494506
30 August 1994 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 524963
30 August 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1354901
3 August 1994 Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1439542

Deficiency record · 4

Deck/Cargo › Cargo Stowage › General
Issued 25 January 2007 Resolved
Cargo tank vents pressure side not functioning properly. Vent bullet heads won't activate or when activate won't close, 3 of the bullet heads contained paint.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2007
Resolution: Cargo tank vents sat.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 24 January 2006 Resolved
Have Classification Society evaluate Lighting Fixture in crew staterooms. Fixtures have no bulb covers and present an electrical shock hazard IAW SOLAS CH II-2 Reg 45.1.3.
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 7 March 2006
Resolution: Received Class Report that there was no requirement for covers on the fluorescent light fittings, and that the above condition was acceptable.
Engineering › Feedwater/Condensate Water System › Valve
Issued 24 January 2006 Resolved
Repair/Replace deck water seal bypass line or valve in pump room to the satisfaction of class society. SOLAS II-1 Reg 26
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 7 March 2006
Resolution: Received Class Report stating that the deck seal valve and by-pass pipe leading to IG deck seal valve were renewed to their satistfaction.
Navigation › Piloting/Steering
Issued 6 May 2004 Resolved
Vessel reported inoperable gyro compass. LEGACY COMPONENT DESC: Gyro Compass
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2004
Resolution: Received technicians report attesting to satisfactory repair to gyro compass.

Ownership record