Records from 1996 to 1998. Most recent: inspection, 7 January 1998.
Lifesaving
Issued 7 January 1998
Resolved
MAJOR LEAK IN EXHAUST MAINFOLD ON PORT LIFEBOAT MOTOR._x001C_ _x001C_ _x001C_ SOLAS 74(AMD) REG III/19-2_x001C_
Condition: Unknown
Due 16 January 1998
Resolved 16 January 1998
Lifesaving
Issued 7 January 1998
Resolved
LIFEBOAT OPERATING INSTRUCTIONS INADEQUATE_x001C_ _x001C_ _x001C_ SOLAS 74(AMD) REG III/9-2
Condition: Unknown
Due 16 January 1998
Resolved 16 January 1998
Documentation
Issued 7 January 1998
Resolved
OIL TRANSFER PROCEDURES INADEQUATE_x001C_ _x001C_ _x001C_ 33 CFR 155.720_x001C_
Condition: Unknown
Due 16 January 1998
Resolved 16 January 1998
Documentation
Issued 7 January 1998
Resolved
SOPEP NOT AVAILABLE IN ENGLISH_x001C_ _x001C_ _x001C_ 33 CFR 151.26(a)_x001C_
Condition: Unknown
Due 16 January 1998
Resolved 16 January 1998
Navigation
Issued 22 October 1997
Resolved
COAST PILOT AND LIGHT LIST WERE NOT UPDATED.
Condition: Unknown
Due 16 January 1998
Resolved 16 January 1998
Electrical
Issued 26 September 1997
Resolved
#2 GENERATOR PACKING LEAKING OIL._x001C_ _x001C_ SOLAS 74(AMENDED) II-2/11
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Lifesaving
Issued 26 September 1997
Resolved
HYDROSTATIC RELEASES PORT AND STBD LIFE RAFTS NOT SERVICED W/IN 12 MONTHS._x001C__x001C_ SOLAS 74(AMENDED) REGIII/19.9.1_x001C_
Condition: Unknown
Due 27 September 1997
Resolved 1 October 1997
Accommodation/Occupational Safety
Issued 26 September 1997
Resolved
INADEQUATE SUPPLIES ONBOARD FOR CREW(NO FOOD ON BOARD)._x001C_ _x001C_ ILO 147/PWSA 33 USC 1223(b)_x001C_
Condition: Unknown
Due 27 September 1997
Resolved 1 October 1997
Electrical
Issued 26 September 1997
Resolved
LIGHTS THROUGHOUT ENGINEROOM AND GALLEY MISSING LIGHT COVERS._x001C_ _x001C_ SOLAS 74(AMENDED) REG II-1/45_x001C_
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Lifesaving
Issued 26 September 1997
Resolved
MIDDLE LIFELINE CABLES MISSING PORT AND STBD BOAT DECKS._x001C_ _x001C_ ILO 147
Condition: Unknown
Due 27 September 1997
Resolved 1 October 1997
Lifesaving
Issued 26 September 1997
Resolved
EXPIRED SMOKE FLOAT LIGHTS PORT AND STBD BRIDGE WINGS._x001C_ _x001C_ SOLAS 74(AMENDED) REG III/7.1.3
Condition: Unknown
Due 27 September 1997
Resolved 1 October 1997
Lifesaving
Issued 26 September 1997
Resolved
EPIRB FLOAT FREE DEVICE DAMAGED, INOP._x001C_ _x001C_ SOLAS 74(AMENDED) IV/7
Condition: Unknown
Due 27 September 1997
Resolved 1 October 1997
Unknown
Issued 26 September 1997
Resolved
SEVEN FEET OF WATER IN STEERING ROOM BILGES._x001C_ _x001C_ ILLC 66 ANNEX I/17
Condition: Unknown
Due 27 September 1997
Resolved 1 October 1997
Unknown
Issued 26 September 1997
Resolved
TEN INCHES OF OIL IN ENGINE ROOM BILGES._x001C_ _x001C_ SOLAS 74(AMENDED) REG II-2/15.2_x001C_
Condition: Unknown
Due 27 September 1997
Resolved 1 October 1997
Unknown
Issued 26 September 1997
Resolved
HOLE IN DECK WALKWAY, PORT SIDE LADDER FWD MAIN SUPERSTRUCTURE._x001C_ _x001C_ ILLC 66 ANNEX I/25
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Engineering
Issued 26 September 1997
Resolved
DISCHARGE OF OIL PROHIBITED PLACARD MISSING._x001C_ _x001C_ 33 CFR 155.450
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Accommodation/Occupational Safety
Issued 26 September 1997
Resolved
MSD PLACARD MISSING._x001C_ _x001C_ 33 CFR 159.59
Condition: Unknown
Due 22 October 1997
Resolved 22 October 1997
Engineering
Issued 26 September 1997
Resolved
OILY WATER SEPARATER NOT OPERATING PROPERLY._x001C_ _x001C_ MARPOL 73/78 ANNEXI/16_x001C_
Condition: Unknown
Due 22 October 1997
Resolved 22 October 1997
Electrical
Issued 26 September 1997
Resolved
# 3 GENERATOR NOT FUNCTIONING._x001C_ _x001C_ SOLAS 74(AMENDED) I/11
Condition: Unknown
Due 16 January 1998
Resolved 16 January 1998
Engineering
Issued 26 September 1997
Resolved
COOLING WATER LEAKING FROM STBD MAIN DIESEL ENGINE._x001C_ _x001C_ SOLAS 74(AMENDED) I/11
Condition: Unknown
Due 27 September 1997
Resolved 1 October 1997
Electrical
Issued 26 September 1997
Resolved
#2 GENERATOR FUEL PUMP INOP._x001C_ _x001C_ SOLAS 74(AMENDED) I/11
Condition: Unknown
Due 27 September 1997
Resolved 1 October 1997
Unknown
Issued 26 September 1997
Resolved
SAFETY GUARDS ON REFER PUMPS NOT WORKING._x001C_ _x001C_ SOLAS 74(AMENDED) REG II-1/26
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Navigation
Issued 26 September 1997
Resolved
RUDDER POSTS LEAKING WATER._x001C_ _x001C_ ILLC 66 ANNEX I/17_x001C_
Condition: Unknown
Due 27 September 1997
Resolved 1 October 1997
Lifesaving
Issued 26 September 1997
Resolved
WINDOW BETWEEN ENGINE ROOM AND CONTROL ROOM BROKEN._x001C_ _x001C_ SOLAS 74(AMENDED) REG I/11_x001C_
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Lifesaving
Issued 26 September 1997
Resolved
LIFE RAFT WEAK LINKS MISSING PORT AND STBD RAFTS._x001C_ _x001C_ SOLAS 74(AMENDED) REG III/29_x001C_
Condition: Unknown
Due 27 September 1997
Resolved 1 October 1997
Lifesaving
Issued 26 September 1997
Resolved
PORT LIFE BOAT CABLES UNEVEN LENGHTS, UNABLE TO STOW BOAT._x001C_ _x001C_ SOLAS 74(AMENDED) REG III/19 _x001C_
Condition: Unknown
Due 27 September 1997
Resolved 1 October 1997
Accommodation/Occupational Safety
Issued 26 September 1997
Resolved
BOX PATCH ON MSD._x001C_ _x001C_ SOLAS 74(AMENDED) I/11
Condition: Unknown
Due 22 October 1997
Resolved 22 October 1997
Lifesaving
Issued 4 October 1996
Resolved
PROVE PROPER OPERATION OF PORT SIDE LIFEBOAT LIMIT SWITCH. (SOLAS 74 CH IIIREG 2)
Condition: Unknown
Due 22 December 1996
Resolved 22 December 1996