Records from 1981 to 2010. Most recent: inspection, 21 December 2010.
Inspection history · 73
21 December 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3914274
21 December 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3914277
21 December 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3914279
3 November 2010
Examination of Repairs · Internal Structural Exam · Hull Examination · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3883514
22 September 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3914211
22 December 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3654037
5 January 2009
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 3389184
2 July 2008
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3255139
11 June 2008
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3233586
14 February 2008
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3147625
2 November 2007
Administrative Inspection · Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3092128
5 June 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2952764
24 May 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2939294
22 August 2006
Deficiency Check · Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2758361
13 February 2006
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2584982
18 October 2005
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2517200
26 September 2005
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2501223
5 December 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2256826
24 August 2004
Hull Examination · Re-Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2168058
2 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979709
30 October 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1938924
22 October 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1693945
24 September 2002
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1679563
6 September 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1671698
17 June 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1632228
25 March 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1632167
8 March 2002
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1597394
7 November 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441933
13 September 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 773109
16 March 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1059916
2 January 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1060974
22 September 2000
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417125
25 July 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1051383
1 November 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 767015
27 October 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 197017
13 May 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404756
9 March 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 797333
22 December 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 808352
3 December 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 665759
23 July 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 197018
19 March 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466027
16 April 1997
COI Inspection · Hull Examination · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446500
17 March 1997
Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1390471
12 March 1997
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1458386
11 March 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 72101
11 March 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 221572
23 February 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 129593
23 February 1997
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1096676
17 October 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461739
21 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 77081
5 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 126558
23 February 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 112640
23 October 1995
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439660
17 November 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1177381
20 October 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356881
30 November 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438116
26 October 1992
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471293
15 October 1991
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1249871
19 October 1990
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899919
5 October 1989
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1329108
15 October 1988
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 887640
14 October 1987
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1018115
30 June 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013329
10 April 1987
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1311696
15 October 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010698
16 October 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293381
7 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291665
20 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978676
18 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976690
20 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278489
2 August 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968261
28 October 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274334
30 October 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 964667
Fire Fighting › Fire Main › Condition
Issued 3 November 2010
Resolved
Unable to witness proper operation of Fire Main do to location of vsl (water level to low, unable to catch suction). Demonstrate proper operation of fire main prior to operating vsl.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2011
Resolution: Witnessed proper operation of fire main.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 July 2008
Resolved
STBD nav light fixture is busted and has melted lens. Replace fixture.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2008
Resolution: Vsl rep reported via fax that deficiency was corrected.
Navigation › Piloting/Steering › Marine Charts
Issued 2 July 2008
Resolved
Missing approach chart for Fourchon, LA. Provide chart.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2008
Resolution: Vsl rep reported via fax that deficiency was corrected.
Electrical › Electrical Distribution System (service) › Conductor
Issued 2 July 2008
Resolved
Provide metal ties for electrical wires in engine room.
Action required: 705 - Other - as specified
Due 2 August 2008
Resolved 2 July 2008
Resolution: Vsl rep reported via fax that deficiency was corrected.
Fire Fighting › Nozzles › Condition
Issued 2 July 2008
Resolved
Fire hose nozzle's fog adapter not working properly / lever is missing screw. Fix or replace nozzle.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2008
Resolution: Vsl rep reported via fax that deficiency was corrected.
Fire Fighting › Fire Hydrants › Condition
Issued 2 November 2007
Resolved
The valve on the starboard fire station was leaking.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 November 2007
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 2 November 2007
Resolved
The manual vent cover leading to the laundry space was stuck in the open position due to painting.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 November 2007
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 2 November 2007
Resolved
Nine kapok life jackets had air leaks and were destroyed on the spot.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 November 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 August 2006
Resolved
Replace all expired eye wash solution bottles.
Due 28 September 2006
Resolved 29 August 2006
Engineering › Freshwater System (cylinder head cooling) › Sensor
Issued 22 August 2006
Resolved
Repair or renew stbd main engine temperature gauge on bridge at main steering stand.
Due 28 September 2006
Resolved 29 August 2006
Engineering › Freshwater System (cylinder head cooling) › Charging Tank
Issued 22 August 2006
Resolved
Repair/renew port side coolant charging tank for main engine.
Due 28 September 2006
Resolved 29 August 2006
Documentation › Certificates/Documents › Stability Letter
Issued 13 February 2006
Resolved
Issued NOV Warning: Failure to be in compliance with the terms of the COI when operating.
Found vsl overloaded per stability ltr.
Due 13 April 2006
Resolved 13 February 2006
Fire Fighting › Portable Foam Applicators
Issued 7 October 2002
Resolved
PROVIDE ADDITIONAL FIRE PROTECTION FOR THE CARRIAGE OF MARINE PORTABLE TANKS. LEGACY COMPONENT DESC: MPT FIRE PROTECTION
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 November 2002
Resolved 8 October 2002
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 7 October 2002
Resolved
REPAIR AND TEST THE SSB RADIO.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2002
Resolved 8 October 2002
Navigation › Piloting/Steering › Compass Deviation Table
Issued 7 October 2002
Resolved
PROVIDE UPDATED COMPASS DEVIATION CARD.
Action required: 705 - Other - as specified
Due 7 November 2002
Resolved 7 October 2002
Electrical › Electric Generation Source (service) › Generator Cable
Issued 7 October 2002
Resolved
REPLACE GENERATOR STARTER CABLES ON BOTH GENERATORS.
Action required: 705 - Other - as specified
Due 7 November 2002
Resolved 7 October 2002
Construction/Loadline
Issued 22 September 2000
Resolved
DEMONSTRATE PROPER OPERATION OF BILGE ALARM VISUAL INDICATOR IN WHEEL HOUSETO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 January 2001
Resolved 3 January 2001
Deck/Cargo
Issued 20 October 1994
Resolved
HYDROSTATICLY TEST F/O TRANSFER HOSES IAW 33 CFR 156.170.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Accommodation/Occupational Safety
Issued 19 October 1990
Resolved
MOVE LOCATION OF STOVE TO AN EXCESSABLE AREA AWAY FROM THE OVEN.
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Accommodation/Occupational Safety
Issued 19 October 1990
Resolved
INSTALL BUG SCREENS ON F/W TANK VENTS.
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Construction/Loadline
Issued 19 October 1990
Resolved
RENEW GASKETS ON ALL WATER TIGHT DOORS AND HATCHES; ADJUST DOGS AND DOORS.
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Accommodation/Occupational Safety
Issued 19 October 1990
Resolved
REPAIR HAND RAIL IN LADDER AREAS.
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Construction/Loadline
Issued 19 October 1990
Resolved
INSERT DECK WHERE SAND BLASTED BLEW THROUGH.
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Accommodation/Occupational Safety
Issued 19 October 1990
Resolved
FASTEN DOWN WASHER, DRYER, AND FREEZER IN HOLD BEFORE ENGINE ROOM.
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990