Records from 1981 to 2023. Most recent: inspection, 6 June 2023.
Inspection history · 104
6 June 2023
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7686921
9 December 2022
Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7606754
15 February 2022
Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7384783
13 January 2022
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7380541
25 June 2021
Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7235947
1 December 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7096817
20 June 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6720369
19 May 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6945334
10 January 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6604868
19 July 2018
Annual Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6475913
11 April 2017
Deficiency Check · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6118962
21 October 2016
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6026968
28 June 2016
Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5917450
26 June 2014
Internal Structural Exam · Drydock Exam · Deficiency Check · Examination of Repairs · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4894052
18 January 2011
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3926501
30 December 2010
Examination of Repairs · In-Service Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3917304
16 March 2010
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3693931
2 April 2009
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3440517
7 August 2008
Administrative Inspection · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3289552
25 March 2008
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3168139
5 April 2007
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2902629
28 March 2007
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2896632
27 September 2006
Administrative Inspection · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2788268
28 June 2006
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2694748
16 August 2005
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2464552
14 June 2005
Examination of Repairs
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2391523
25 August 2004
Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2176680
21 July 2004
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2140861
22 June 2004
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2106634
7 May 2003
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1788632
15 April 2003
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1774019
11 March 2003
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1753310
14 August 2002
Administrative Inspection
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1661418
14 August 2002
Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1661778
2 April 2002
COI Inspection · Examination of Repairs
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1599899
9 July 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1075033
31 May 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1376617
14 August 2000
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1418756
16 March 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1459574
26 March 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 790542
19 March 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1441471
23 September 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 800186
21 August 1998
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1375466
14 August 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 156848
11 August 1998
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1431996
19 June 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396945
20 May 1998
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 790610
20 May 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1364737
1 May 1997
Deficiency Check · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1409676
23 February 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 129593
23 February 1997
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1096678
29 October 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1163470
18 October 1996
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407770
28 March 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1424210
21 March 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385661
3 January 1996
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1445034
30 December 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 19256
30 December 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 137848
14 December 1995
Damage Survey · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463928
13 December 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 21873
23 March 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1454167
10 November 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 867650
20 October 1994
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1182056
31 August 1994
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 472722
3 May 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 861789
14 April 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425434
23 December 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 506692
2 December 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 461746
3 August 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1151309
31 July 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 447356
1 July 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 849884
10 June 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1148351
6 May 1993
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1142412
12 April 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 509664
6 January 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 355745
23 October 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419057
9 June 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 953869
8 May 1992
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1260240
7 May 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1259071
2 July 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1252130
7 May 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1230513
16 April 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 919900
12 September 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902040
4 October 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1339465
29 September 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1031508
13 September 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034610
5 September 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1194750
21 June 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1200670
24 August 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1350461
4 April 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 993685
1 December 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1001096
9 October 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1322231
11 September 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1319458
1 September 1987
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1001929
2 December 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1330801
19 September 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004358
21 July 1986
Credit Drydock · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 990501
5 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982042
11 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286336
10 July 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973534
11 July 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967592
23 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965517
23 July 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 969710
23 July 1981
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1274182
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 June 2023
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The annual inspection anniversary date for the [name withheld] is February 15 and the annual inspection has not been scheduled to be completed by May 15.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2023
Resolved 6 June 2023
Resolution: Annual Inspection conducted on 06JUN2023.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 June 2023
Resolved
At each inspection, all generators, motors, lighting fixtures, and circuit interrupting devices shall be checked. Oil leaks identified on both port and starboard generators. Repair.
46 CFR 176.25-15
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 6 June 2023
Resolved 29 June 2023
Resolution: Oil leaks fixed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 June 2023
Resolved
Except as otherwise provided in this section, vessels in ocean service shall carry sufficient life floats for all persons on board. Vessel found with missing 24-person life float. Replace or provide appropriate life float to meet COI requirement.
46 CFR 180.10-5(a)
Action required: 60 - Rectify deficiencies prior to movement
Due 6 June 2023
Resolved 29 June 2023
Resolution: Life float replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 June 2023
Resolved
Main steering apparatus shall be tested for operation and inspection shall examine mechanism. Port rudder mechanical stops did not function as required, allowing rudder to continue to travel by shifting the mounting arrangements. Conduct needed repairs of steering system.
46 CFR 176.25-35(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2023
Resolved 30 June 2023
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 June 2023
Resolved
At each inspection, view vessel afloat and examine all visible parts of the exterior and interior of the hull. In forepeak IVO frwd centerline, an 8" section of side shell plate was missing the interior weld seam. Complete weld on plate.
46 CFR 176.25-5(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2023
Resolved 29 June 2023
Resolution: Plate welded.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 6 June 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Multiple box lighting fixtures in engine room found inoperable. Replace or repair fixtures.
46 CFR 183.01-15(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 June 2023
Resolved
Vessels shall be equipped with a suitable number of portable battery lights. Vessel’s portable lights found inoperable in engine room. Replace or repair.
46 CFR 184.30-1(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Starboard spotlight found inoperable. Replace or repair.
46 CFR 183.01-15(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Abandoned dead end wires found in old through hull fitting from previous transducer. Remove.
46 CFR 183.01-15(a)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2023
Resolved
At each inspection, examine and test the following items: (1) Electrical cable. The cable shall be examined as far as practicable without undue disturbance of the cable or electrical apparatus. Multiple dead end wires found underneath operating station console. Replace or repair.
46 CFR 176.25-15(a)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2023
Resolved
At each inspection, examine and test the following items: (4) Generators, etc. All generators, motors, lighting fixtures and circuit interrupting devices shall be checked. DC charger under operating station console not mounted properly. Fasten and mount charger correctly.
46 CFR 176.25-15(a)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 June 2023
Resolved
At each inspection, the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Perko switch from battery to generator found incorrectly fastened. Mount correctly.
46 CFR 176.25-50(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Main distribution panel found missing directory to each associated system. Provide labeling or directory.
46 CFR 183.01-15(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 June 2023
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit found with expired aspirin. Replace.
46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2023
Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Three life preservers found with severely faded retro reflective tape and one life preserver found with a broken float light. Replace retro reflective tape and float light.
46 CFR 180.25-5 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 6 June 2023
Resolved
The master of each vessel subject to this subpart shall ensure that suitable public announcements, instructive placards or both are provided with… Proper method of donning and adjusting life preservers of the type(s) carried on the vessel. Vessel missing four life jacket donning placards for the types that are carried onboard. Post correct placards.
46 CFR 185.25-1(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 June 2023
Resolved
All life floats and buoyant apparatus shall be conspicuously marked with the vessel’s name. In addition the number of persons allowed on each life float or buoyant apparatus shall be conspicuously marked. Severely faded markings identified on lifefloats. Appropriately remark lifefloats.
46 CFR 180.20-5(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 June 2023
Resolved
Each life float shall be fitted with a life line and shall be equipped with two paddles, a water light and a painter. Water light attached to life float found broken. Replace or repair.
46 CFR 180.15-1(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 6 June 2023
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. Public address system found inoperable. Replace or repair.
46 CFR 184.610(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 6 June 2023
Resolved
The licensed individuals employed upon any vessel subject to the provisions of this subchapter shall have their license in their possession and available for examination at all times. Master medical certificate found expired. Provide valid medical certificate.
46 CFR 185.10-1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 June 2023
Resolved
Each vessel in ocean and coastwise service must have an approved Class A emergency position indication radiobeacon (EPIRB) that is ---(1) Operative. Vessel rep unable to satisfactorily test EPIRB to show operative condition. Replace or repair.
46 CFR 180.40-1(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 June 2023
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1- inch letters: "Emergency Exit, Keep Clear." The markings found on the FWD Emergency exit in passenger space were small and sun damaged, making them difficult to read. Remark.
46 CFR 185.40-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2023
Resolved
At each inspection, the setting of the relief valves on unfired pressure vessels shall be checked. Unable to verify relief valves settings for Port/Starboard UPVs.
46 CFR 176.25-32(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 30 June 2023
Resolution: Vessel rep installed proper safety relief valves
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 June 2023
Resolved
At each inspection, view vessel afloat and examine all visible parts of the exterior and interior of the hull. In forepeak IVO hatch cover, found weld failures on insert, top aft weld seam. Conduct needed repairs of weld.
46 CFR 176.25-5(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 June 2023
Resolved
At each inspection, view vessel afloat and examine all visible parts of the exterior and interior of the hull. In lazerette starboard quarter IVO top round, found weld failures with evidence of water intrusion. Conduct needed repairs of weld.
46 CFR 176.25-5(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 June 2023
Resolved
At each inspection, examine and test the following items: (3) Engine control mechanisms. Port M/E solenoid valve found inoperable. Replace or repair.
46 CFR 176.25-10(a)(3)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Protection machines/parts
Issued 6 June 2023
Resolved
Protective gratings shall be provided at such locations where persons or gear might come in contact with the exhaust pipe. Port generator exhaust piping found missing portions of lagging. Install adequate lagging.
46 CFR 182.15-20(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 June 2023
Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. The no. 2 steering pump found with inadequate levels of hydraulic fluid. Restore hydraulic fluid in pump.
46 CFR 182.30-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 June 2023
Resolved
Minimum capacity of the fire pump shall be at least 60 PSI and pump outlet shall be fitted with a gauge. Gauge was found cracked. Renew.
46 CFR 181.10-1(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 June 2023
Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. Portable fire extinguisher mounts found removed from station. Reattach mounts.
46 CFR 181.30-10(b)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2023
Resolved
Rigid non-metallic piping is acceptable for non-vital systems. Bilge system throughout vessel has sections of flexible hoses; renew with approved material.
46 CFR 182.40-5(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2023
Resolved 29 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 June 2023
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Interconnected system not functioning as required. Repair.
46 CFR 181.405(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2023
Resolved 29 June 2023
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 December 2022
Resolved
AT EACH INITIAL AND SUBSEQUENT INSPECTION FOR CERTIFICATION OF A VESSEL, THE OWNER OR MANAGING OPERATOR SHALL BE PREPARED TO CONDUCT TESTS AND HAVE THE VESSEL READY FOR INSPECTIONS OF THE HULL STRUCTURE AND ITS APPURTENANCES, INCLUDING THE FOLLOWING: INSPECTION OF ALL ACCESSIBLE PARTS OF THE EXTERIOR AND INTERIOR OF THE HULL, THE WATERTIGHT BULKEADS, AND WEATHERTIGH BULKHEADS. WHILE CONDUCTING AN INSPECTION OF THE HULL, THE MARINE INSPECTOR IDENTIFIED A 6-9" SHARP INSET ON THE PORT BOW THAT GOES DIRECTLY INTO THE FOREPEAK. MARINE INSPECTIOR REQUIRES FOR THE VESSEL TO REPLACE IN KIND.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 29 December 2022
Resolved 12 January 2023
Resolution: Inspected interior and exterior welded insert in the port bow hull and conducted non-destructive testing with dye penetrant method, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 February 2022
Resolved
Port generator has excessive oil leaks. Make repairs to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 10 March 2022
Resolved 8 March 2022
Resolution: Conducted satisfactory repairs. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 February 2022
Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personal injury.
Port generator windings coated in oil.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 12 March 2022
Resolved 8 March 2022
Resolution: Cleaned generator windings to satisfaction of inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 February 2022
Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personal injury.
Generator mountig bolts not properly secured.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2022
Resolved 8 March 2022
Resolution: Properly secured generator.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 15 February 2022
Resolved
A vessel must be fitted with a Federal Communications Commission (FCC) type accepted general marine radar system for surface navigation with a radar screen mounted at the primary operating station.
Radar is inoperable. Make repairs to the satisfaction of the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2022
Resolved 8 March 2022
Resolution: Radar is operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 February 2022
Resolved
Generators and motors for use in machinery spaces shall generally be designed for an ambient temperature of 50 degrees Celsius.
Both generators are rated at 40 degree Celsius. Generators will need to be derated 80% or prove the generator is adequate to 50 degrees Celsius to the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2022
Resolved 8 March 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 February 2022
Resolved
Examine and test by operation all watertight closures in the hull, decks and bulkheads.
Water tight forward gasket is caulked and not water tight. Make repairs to hatch gasket to the satisfaction of the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2022
Resolved 8 March 2022
Resolution: Gasket was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 February 2022
Resolved
The main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personal injury.
Port and Starboard air receiver relief valve did not operate as designed. Repair or replace to the satisfaction of the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2022
Resolved 8 March 2022
Resolution: Relief valves operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 February 2022
Resolved
The main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personal injury.
Replace oil cooling line, gauge, mechanical guards and remove corrosion to the satisfaction of the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2022
Resolved 8 March 2022
Resolution: Replaced oil cooling line, gauge, and mechanical guards.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 February 2022
Resolved
Each EPIRB must be tested monthly.
No records of EPIRB being tested monthly. Maintain logs for life saving equipment.
Action required: 60 - Rectify deficiencies prior to movement
Due 11 March 2022
Resolved 8 March 2022
Resolution: Provided logs.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 15 February 2022
Resolved
Each survival craft, rescue boat and launching apparatus must be inspected monthly per manufactures instructions.
grab line for life float deteriorated. Replace line, repaint and maintain log of lifesaving equipment maintenance to satisfaction of marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 March 2022
Resolved 8 March 2022
Resolution: Life float satisfactory.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 15 February 2022
Resolved
Junction boxes, connections boxes and outlet boxes for use in damp locations shall be of water tight construction.
Found engine room junction box to be full of water. Check all junction boxes and repair or replace to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Repaired to the satisfaction of the MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2022
Resolved
The generator circuit breakers must be interlocked to prevent the generators from simultaneously connected to the switch board.
Handle for interlock is broken. Repair or replace to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Handle repaired. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2022
Resolved
Equipment is so constructed or protected that is successful operation is not interfered with when subjected to falling moisture, dirt, or uninsulated parts cannot be touched or approached by any person
Breaker panel in engine room has excessive rust Clean or to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Breaker panels cleaned up to satisfaction of MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2022
Resolved
Equipment is so constructed or protected that is successful operation is not interfered with when subjected to falling moisture, dirt, or uninsulated parts cannot be touched or approached by any person
Distribution panel in galley is missing blanks. Install blanks where breakers are missing to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Installed blanks.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2022
Resolved
Equipment is so constructed or protected that is successful operation is not interfered with when subjected to falling moisture, dirt, or uninsulated parts cannot be touched or approached by any person
Galley hood light is missing guard. Replace guard to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Installed guard for lights.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 15 February 2022
Resolved
shall be fitted with matt black inboard screens and meet the requirements of § 84.15.
VSL was not fitted with matt black. Paint to satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Matte black navigation light background.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 February 2022
Resolved
This part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personal injury.
all three reduction gear PSI gauges inoperative. Repair or replace to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Replaced PSI gauges on reduction gear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 February 2022
Resolved
This part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personal injury.
Witnessed multiple twisted hoses on machinery. Repair or replace hoses to satisfaction of marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Repaired machinery hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 February 2022
Resolved
This part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personal injury.
MDE fuel filter crimped. Replace to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Fuel filter replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2022
Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected.
Washer and Dryer were not secured for sea. Secure to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Washer and dryer secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2022
Resolved
Vessel shall be inspected for compliance with the standards required by this subchapter. For items not covered by these standards inspections shall be in accordance with with standards acceptable to the OCMI as good marine practice.
Vsl did not have collection system for dryer vent.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Installed collection for dryer vent.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 January 2022
Resolved
At each inspection for a vessel, all observed unsafe practices must be corrected; there was significiant oil accumulation in the engine room bilges.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2022
Resolved 15 February 2022
Resolution: Oil was cleaned up upon inspection.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 January 2022
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape; emergency lights leading out of the engine room were inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2022
Resolved 15 February 2022
Resolution: Emergency lights were operable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 January 2022
Resolved
Each distribution panel must be totally enclosed and of the deadfront type; breaker panel in the galley was completely exposed.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2022
Resolved 15 February 2022
Resolution: Panel was secured.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 January 2022
Resolved
All navigation lights must be in compliance with the inland and international navigation rules; all navigations lights are inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2022
Resolved 15 February 2022
Resolution: Navigation lights are operable.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 January 2022
Resolved
The master or owner shall ensure that crewmembers, prior to getting underway and at least once every three months, are instructed in the duties in the event of an emergency; drills have been irregularly logged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2022
Resolved 15 February 2022
Resolution: Created logs and plan for drills.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 January 2022
Resolved
Each inspection must include an inspection of the ship's lifesaving equipment; lifefloats had unapproved retro-reflective tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2022
Resolved 15 February 2022
Resolution: Retro was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 January 2022
Resolved
The master shall ensure that monthly EPIRB checks are completed; EPIRB checks have not been logged.
Action required: 10 - Deficiency Rectified
Due 13 January 2022
Resolved 13 January 2022
Resolution: Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 July 2021
Resolved
At each inspection the marine inspector shall examine the bilges and other spaces to see hat there is no accumulation of oil or other matter which might create a fire hazards. Discovered fuel leaking from port generator fuel return line. Make proper repairs to the satisfaction of the attending marine inspector.
46CFR176.25-50(b)
(old T)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 October 2021
Resolution: located and tightened a loose compression union on port generator fuel return line
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Water, pipes, tanks
Issued 15 July 2021
Resolved
All pressure vessels shall be subject to hydrostatic test of 1 1/4 times the maximum allowable working pressure. Discovered excessive corroding of both port and starboard start air compressor tanks. Conduct hydrostatic test and provide report to the attending marine inspector.
46CFR176.25-30(b)(4)
(Old T)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 September 2021
Resolution: Sept 28th 2021 performed hydrostatic pressure test on both port and starboard air receivers on [name withheld] both receivers from vessel and plugged all ports. Filled with water and pressured up to 225 psi. no leaks
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 15 July 2021
Resolved
All vessels shall be provided with two means of escape from all general areas. Emergency escape hatch to the bow was not maintained and dogs were inoperable, rectified before inspection finished.
46CFR177.15-1(a)
(Old T)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 July 2021
Resolved
Life floats stowed in tiers must be kept apart by spacers. Provide pictures of spacers installed between tier stowed life floats.
46CFR180.20-1(a)(7)
(Old T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2021
Resolved 13 October 2021
Resolution: inserted wood spacers between stowed life floats
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 July 2021
Resolved
Each class one door on a vessel in ocean service must be designed to withstand a head of water equivalent to a depth from the sill of the door to the margin line. Engine room door seal was damaged due to improper adjustment of the dogs. Provide proof of proper adjustment to the satisfaction of the attending marine inspector.
46CFR170.270(b)
(Old T)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 October 2021
Resolution: replaced hinges on engine room door to provide proper alignment of door to door opening. Adjusted dogs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 July 2021
Resolved
On metal vessels all frames of major electrical equipment shall be permanently grounded. Grounding strap for starboard generator was severed. Provide pictures of new grounding strap installed on STBD generator.
46CFR183.05-50(d)
(Old T)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 October 2021
Resolution: installed new grounding strap on Starboard generator
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 15 July 2021
Resolved
The marine inspector shall require that all observed unsafe hazardous situations be corrected. Vessel's hot water heater was severely corroded at the base, conduct maintenance or replace in kind to the satisfaction of the attending marine inspector.
46CFR176.25-50(a)
(Old T)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2021
Resolved 13 October 2021
Resolution: cleaned surface rust, inspected and painted water heater
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 July 2021
Resolved
The master shall conduct drills and give instructions as necessary to ensure that all crew are familiar with their duties. Vessel has been laid up and no drills or maintenance conducted. Provide records of drills and maintenance prior to operation.
46CFR185.25-10
(Old T)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2021
Resolution: vessel provided proof of drills
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 25 June 2021
Resolved
The marine inspector shall require that all observed unsafe hazardous situations be corrected. Forward passenger seating compartment had water ingress from leaking windows saturating the particle board life vest storage bin/seating. Prove proper repairs to compartment windows stopping the ingress of water to the satisfaction of the attending marine inspector.
46CFR176.25-50(a)
(Old T)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2021
Resolution: Vessel provided pictures of repairs to the crew window in question, proof of repairs accepted
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 July 2018
Resolved
Fire pump un-able to gain prime.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2018
Resolved 2 August 2018
Resolution: Witnessed adequate priming, pressure, and satisfactory operation of fire pump / fire main system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2018
Resolved
Centerline main engine has major F/O leak on PORT side cylinder head. 1 drop per 5 seconds.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2018
Resolved 2 August 2018
Resolution: Verified repair to centerline engine; witness satisfactory leak-free operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2018
Resolved
STBD main engine air sep is leaking oil onto Inboard exhaust manifold.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2018
Resolved 2 August 2018
Resolution: Verified repair of STBD MDE; witnessed satisfactory leak-free operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 July 2018
Resolved
PORT GENSET un-able to hold ships load.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2018
Resolved 2 August 2018
Resolution: Witnessed Port Genset under load with no issues.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2018
Resolved
PORT Main engine F/O suspply line leaking fuel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 2 August 2018
Resolution: Verified fuel line fitting / tubing was remade and witnessed leak free operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2018
Resolved
STBD Main engine has exhaust leak on compressor side of turbo.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 2 August 2018
Resolution: Verified repair to gasket on turbocharger; witnessed leak-free operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 July 2018
Resolved
Steering fluid leak in steering space overhead tubing. 1 drop every 10 seconds
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 2 August 2018
Resolution: Section of hydraulic steering tubing was replaced and fittings retightened; Witnessed leak-free operation of steering system.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 19 July 2018
Resolved
Vessel only has life float capacity for 53 persons. COI states 56 persons. vessel has been reduced to carry 53 persons until corrected.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 2 August 2018
Resolution: Vessel removed incorrect Life float and replaced in kind with adequate life float.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 July 2018
Resolved
PORT battery bank has loose terminal
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 2 August 2018
Resolution: Verified all terminals on port battery bank were properly secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2018
Resolved
PORT Main engine exhaust discharge hose missing clamp on through hull fitting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 2 August 2018
Resolution: Second clamp was installed.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 10 May 2017
Resolved
Do not operate vessel more than 20 miles offshore until both the VHF-DSC and MF-DSC radios are functioning properly and verified to the satisfaction of attending marine inspector. 47 CFR 80.905
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 27 June 2017
Resolution: Reviewed docs and tested radio. All sat.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 11 April 2017
Resolved
Replace gauge on port side air receiver and conduct safety relief valve test to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 20 April 2017
Resolution: Witnessed replaced gauge on port side air receiver and observed satisfactory safety relief valve test.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 11 April 2017
Resolved
Repair aft port side ventilation and demonstrate to the satisfaction of attending Marine Inspector ability to close ventilation.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 20 April 2017
Resolution: Observed properation operation of ventilation on port aft of vessel.
Engineering › Steering Gear System › Hydraulic Hose
Issued 11 April 2017
Resolved
Replace hydraulic lines in steering compartment to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 20 April 2017
Resolution: Verified replaced hyrdaulic lines and expected for condition and leaks. All sat.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 11 April 2017
Resolved
Conduct Man Overboard Drill to the satisfaction of attending Marine Inspector.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 20 April 2017
Resolution: Conducted underway drills to the satisfaction of Attending CG Marine Inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 August 2016
Resolved
Vessels lower not under command nav light is cocked and needs proper installation.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 4 August 2016
Resolution: Light bracket repositioned
Electrical › Electric Generation Source (service) › Generator
Issued 28 June 2016
Resolved
Oil leak at governor area
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Oil leak corrected.
Electrical › Electric Generation Source (emergency) › Generator
Issued 28 June 2016
Resolved
Both generators are missing safety guards over front pulley
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Installed guards.
Engineering › Pressure Vessel › Relief Valve
Issued 28 June 2016
Resolved
Relief valves and data plates are painted over on both air receivers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Renewed nameplate and relief valves.
Engineering › Fuel Oil Service System › Hose
Issued 28 June 2016
Resolved
fuel tank bonding strap for fuel fill is broken and tank top has fuel on top.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Bonding strap installed and fuel removed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 June 2016
Resolved
Battery box has oil in it and improper terminal connector installed
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Battery connections corrected and oil removed from battery box.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 28 June 2016
Resolved
Excessive oil leak from top of cylinder head
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Oil leak corrected
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 28 June 2016
Resolved
MDE junction boxes have dead end wires and loose connections
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Dead end wires removed.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 28 June 2016
Resolved
RPM gauge removed with dead end wires hanging loose
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Gage wires removed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 28 June 2016
Resolved
missing lagging on exhaust piping
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Lagging installed.
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 28 June 2016
Resolved
improper installation of jacket water high temp alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Main Eng J/W sensors relocated and properly installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 28 June 2016
Resolved
hydraulic diverter valve above port engine excessive oil leak
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Diverter valve replaced.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 28 June 2016
Resolved
Various smoke detectors disabled and various non authorized detectors
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: New detectors installed throughout.
Operations/Management › Vessel Activity › Other
Issued 28 June 2016
Resolved
Various chemicals and cleaning agents located through out ship and not properly stored
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Chemicals removed or properly stowed.
Communications › Public Address System › Announcing Station
Issued 28 June 2016
Resolved
P/A system not funcyioning properly
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: P/A system repaired.
Engineering › Bilge Water Management System › Not Operational
Issued 28 June 2016
Resolved
Bilge pump system not functioning properly
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Bilge pump repaired and tested.
Fire Fighting › Fire Pumps › Pressure
Issued 28 June 2016
Resolved
Fire pump not operating properly
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Fire pump repaired and tested.
Stability › Watertight Integrity › General
Issued 26 June 2014
Resolved
Adjust engineroom watertight door.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2014
Resolution: Witnessed WTD adjusted satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 26 June 2014
Resolved
Make weld repairs to the following locations: Both SSDG exhaust cracks. B) Overhead by the engineroom emergency escape C) Stbd side midship frame. D) Port deck overhead
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2014
Resolution: All welds visually inspected sat and dye-penned satisfactory.
Engineering › Compressed Air System (start air) › Valve
Issued 26 June 2014
Resolved
Replace both air receiver relief valves.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2014
Resolution: Witnessed both air receiver relief valves replaced and popped at 150 psi.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 26 June 2014
Resolved
Make operable the ground indicator switchboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2014
Resolution: ground indicator switch now works.
Engineering › Fuel Oil Service System › Hose
Issued 26 June 2014
Resolved
Replace stb generator F/O hose sleeve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2014
Resolved 3 July 2014
Resolution: Witnessed new F/O hoses installed.
Engineering › Fuel Oil Service System › Hose
Issued 26 June 2014
Resolved
Provide chaffing gear for stbd generator F/O supply hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2014
Resolution: Witnessed new F/O hoses and chaffing gear installed on stbd generator.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 26 June 2014
Resolved
Adjust switchboard breaker interlock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2014
Resolution: Switchboard breaker interlock was adjusted
Construction/Loadline › Structures › End Bulkhead
Issued 26 June 2014
Resolved
Crop and renew port fwd bulkhead lazarette as marked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2014
Resolution: Witnessed satisfactory insert in bulkhead. Conducted sat visual inspection and dye-pen test.
Fire Fighting › Fire Pumps › Capacity
Issued 18 January 2011
Resolved
Fire pump was found to produce 54 PSI rather than the required 60 PSI
Due 20 January 2011
Resolved 20 January 2011
Resolution: Switched out fire pump. Tested new pump and found to produce well about the required 60 PSI.
Construction/Loadline › Hull › Side Shell
Issued 18 January 2011
Resolved
Observed crack on generator exhaust on port side.
Due 20 January 2011
Resolved 20 January 2011
Resolution: Gouged and re-welded around port generator exhaust. Found weld to be satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 18 January 2011
Resolved
Deck plates in center of engine room not secure to the extent they cause a personnel hazard.
Due 20 January 2011
Resolved 20 January 2011
Resolution: Examined secured deck plates in center of engine room.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 28 March 2007
Resolved
Provide a waste management plan/disposal log for the vsl in accordance with 33cfr151.57.
Due 28 April 2007
Resolved 30 March 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 March 2007
Resolved
properly label bilge alarm panel on bridge.
Due 28 April 2007
Resolved 28 March 2007
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 28 March 2007
Resolved
Provide proper day shapes for vsl.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 5 April 2007
Resolution: Proper day shapes provided.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 28 March 2007
Resolved
Paint draft marks a contrasting color on outer hull.
Due 28 April 2007
Resolved 28 March 2007
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 28 March 2007
Resolved
Provide and post required EAP information.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 5 April 2007
Resolution: Required EAP info provided and posted.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 28 March 2007
Resolved
Provide a proper means of immediate closure (ball type checks) for all fuel/oil tank vents on deck.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 5 April 2007
Resolution: Proper means of immediate closure for all fuel/oil tank vents on deck provided.
Stability › Watertight Integrity › General
Issued 28 March 2007
Resolved
Adjust w/t door dogs on fwd escape hatch and fwd e/r door.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 28 March 2007
Resolved
Provide insulation/lagging for stbd generator exhaust piping.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 5 April 2007
Resolution: Insulation/lagging provided for stbd generator exhaust piping.
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 28 March 2007
Resolved
Professionally clean armatures/windings for both vsl service generators.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 5 April 2007
Resolution: Armatures/windings for both vsl service generators professionally cleaned.
Engineering › Generator (propulsion/auxiliary-electric) › Battery Charging Circuitry
Issued 28 March 2007
Resolved
Hard wire battery charger for generator service batteries.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 5 April 2007
Resolution: Battery charger for generator service batteries hard wired.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 28 March 2007
Resolved
Provide proper marine mounting brackets for portable fire extinguishers.
Due 28 April 2007
Resolved 30 March 2007
Engineering › Lubricating Oil Service System › Piping
Issued 28 March 2007
Resolved
Double hose clamp all non-metalic lube oil tank lines.
Due 28 April 2007
Resolved 30 March 2007
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 March 2007
Resolved
Label 12-volt electrical service box with type of service.
Due 28 April 2007
Resolved 30 March 2007
Engineering › Lubricating Oil Service System › Valve
Issued 28 March 2007
Resolved
Provide a secondary means of closure (cap) for for lube oil storage tank discharge valve.
Due 28 April 2007
Resolved 30 March 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 March 2007
Resolved
Hard wire 110 volt inverter under the console in the wheel house.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 8 September 2016
Resolution: 110 volt inverter under the console in wheel house hard wired.
Lifesaving › Lifefloat › Painter
Issued 28 March 2007
Resolved
Provide tether between lifefloats of a sufficient length to reach the water when deploying one at a time.
Due 28 April 2007
Resolved 30 March 2007
Communications › Radio Communications › EPIRB
Issued 28 March 2007
Resolved
Provide a new antenna for EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2007
Engineering › Pressure Vessel › Relief Valve
Issued 28 March 2007
Resolved
Provide proper sized relief valves for both pressure vessels.
Due 28 April 2007
Resolved 30 March 2007
Stability › Watertight Integrity › General
Issued 28 March 2007
Resolved
Provide inner handle for escape hatch leading out of engine room on deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2007
Fire Fighting › Fire Pumps › Pressure
Issued 28 March 2007
Resolved
Make repairs to fire pump to provide required water pressure through one hose.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2007
Resolution: Repairs made to fire pump to allow for required water pressure through one house.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 28 March 2007
Resolved
Provide required alcohol test kit onboard vessel.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 5 April 2007
Resolution: Alcohol test kit provided onboard vsl.
Fire Fighting › Portable Foam Applicators › General
Issued 28 June 2006
Resolved
Portable Foam applicator, line eductor, and AFFF, required as per COI endorsement.
Action required: 705 - Other - as specified
Resolved 14 July 2006
Resolution: Corrected.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 28 June 2006
Resolved
Provide emergency lighting at the engine room escape scuttle.
Action required: 705 - Other - as specified
Due 15 July 2006
Resolved 14 July 2006
Resolution: Corrected.
Stability › Watertight Integrity › General
Issued 28 June 2006
Resolved
Adjust watertight door leading into the engine room.
Action required: 705 - Other - as specified
Due 15 July 2006
Resolved 14 July 2006
Resolution: Corrected.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 28 June 2006
Resolved
Provide FCC Marine Radio Operators License for the Master.
Action required: 705 - Other - as specified
Due 15 July 2006
Resolved 14 July 2006
Resolution: Corrected.
Fire Fighting › Fire Pumps › Pressure
Issued 28 June 2006
Resolved
Provide new fire pump gauge.
Action required: 705 - Other - as specified
Due 15 July 2006
Resolved 14 July 2006
Resolution: Corrected.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 16 August 2005
Resolved
Provide written evidence that the master of the vessel has the appropriate radio operators license.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2005
Resolved 14 July 2006
Resolution: Corrected.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 16 August 2005
Resolved
Provide proof the air receivers have been inspected, or make both air receivers available for inspection.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 28 September 2006
Navigation › Piloting/Steering › Marine Charts
Issued 22 June 2004
Resolved
Prove charts are being corrected for the area the vessel operates in.
Due 22 July 2004
Resolved 22 July 2004
Electrical › Lighting (service) › Conductor
Issued 22 June 2004
Resolved
Replace electrical wires leading to light switch in lazarette.
Due 22 July 2004
Resolved 22 July 2004
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 22 June 2004
Resolved
Replace hoses and piping (with elbow connection) leading to oil tank in lazarette.
Due 22 July 2004
Resolved 22 July 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 22 June 2004
Resolved
Replace lagging on both generator exhausts and starboard and port main engines.
Due 22 July 2004
Resolved 22 July 2004
Engineering › Compressed Air System (start air) › Control Gear
Issued 22 June 2004
Resolved
Find and repair oil leak around starboard air throttle actuator.
Due 22 July 2004
Resolved 22 July 2004
Engineering › Generator (propulsion-electric) › Outlet Box
Issued 22 June 2004
Resolved
Repair excessive lube oil leaks on starboard generator.
Due 22 July 2004
Resolved 22 July 2004
Accommodation/Occupational Safety
Issued 7 May 2003
Resolved
test
Due 9 May 2003
Resolved 9 May 2003
Electrical › Electrical Distribution System (service)
Issued 6 March 2003
Resolved
Provide and install blank cover in electrical distribution panel on bridge.
Due 11 April 2003
Resolved 15 April 2003
Engineering › Bilge Water Management System
Issued 6 March 2003
Resolved
Prove high level bilge alarm for the engine room.
Due 11 April 2003
Resolved 15 April 2003
Electrical › Electric Supply System (service)
Issued 6 March 2003
Resolved
Remove power strip and ext. cords under console and properly mount electrical box under the same.
Due 11 April 2003
Resolved 15 April 2003
Lifesaving › Buoyant Apparatus
Issued 6 March 2003
Resolved
Properly secure paddles to life floats.
Due 11 April 2003
Resolved 15 April 2003
Lifesaving › Buoyant Apparatus
Issued 6 March 2003
Resolved
Provide and replace painter lines on all life floats and provide proper weak link.
Due 11 April 2003
Resolved 15 April 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 6 March 2003
Resolved
Provide first aid kit.
Due 11 April 2003
Resolved 15 April 2003
Construction/Loadline › Penetrations
Issued 6 March 2003
Resolved
Provide and install proper gasket for hatch in forward crew compartment . LEGACY COMPONENT DESC: Gasket
Due 11 April 2003
Resolved 8 May 2003
Stability › Watertight Integrity
Issued 6 March 2003
Resolved
Repair port lights in forward crew compartment. LEGACY COMPONENT DESC: port lights
Due 11 April 2003
Resolved 8 May 2003
Stability › Watertight Integrity
Issued 6 March 2003
Resolved
Crop and renew hole in hull on port side just below the main deck in forward crew compartment. LEGACY COMPONENT DESC: hull
Due 11 April 2003
Resolved 8 May 2003
Resolution: Completed.
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 6 March 2003
Resolved
Provide rack lights for all crew racks in berthing compartment. LEGACY COMPONENT DESC: Berth
Due 11 April 2003
Resolved 8 May 2003
Resolution: Lights installed.
Electrical › Electric Supply System (service)
Issued 6 March 2003
Resolved
Provide an approved rubber mat for the electrical switch board in the engine room.
Due 11 April 2003
Resolved 15 April 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 6 March 2003
Resolved
Remove all oil and open containers in front of the switch board.
Due 11 April 2003
Resolved 15 April 2003
Construction/Loadline › Hull
Issued 2 April 2002
Resolved
Repair (2) two broken welds where marked in lazaret. LEGACY COMPONENT DESC: Weld
Condition: Unknown
Due 2 May 2002
Resolved 11 April 2002
Resolution: Welds repaired.
[name withheld]
Engineering › Compressed Air System (control)
Issued 2 April 2002
Resolved
Unable to read Stbd side air compressor tank PSI. Prove Max PSI or replace. LEGACY COMPONENT DESC: Compressor
Condition: Improper/Lack of Maintenance
Due 2 May 2002
Resolved 11 April 2002
Resolution: Proved Max PSI.
[name withheld]
Lifesaving › Buoyant Apparatus
Issued 2 April 2002
Resolved
Vessel COI allows for a total of 64 persons on board. Vessel is outfitted with buoyant apparatus capable of carrying only 62 Crew and personal.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 8 September 2016
Resolution: The Owner Operator of the [name withheld] has requested in the form of a letter to reduce his Passengers to 58 on his COI.
Lifesaving
Issued 31 May 2001
Resolved
INSTALL WEAKLINK ON 25 PERSON LIFERAFT WITH COAST GUARD APPROVAL TAG ATTACHED.
Condition: Unknown
Due 31 May 2001
Resolved 31 May 2001
Navigation
Issued 31 May 2001
Resolved
PROVE CHARTS ARE BEING CORRECTED.
Condition: Unknown
Due 31 May 2001
Resolved 31 May 2001
Electrical
Issued 31 May 2001
Resolved
INSTALL NON CORROSIVE LINING IN BATTERY BOX ON PORT SIDE AFT OF ENGINE ROOM.
Condition: Unknown
Due 31 May 2001
Resolved 31 May 2001
Navigation
Issued 31 May 2001
Resolved
PROVE COMPASS LIGHT WORKS.
Condition: Unknown
Due 31 May 2001
Resolved 31 May 2001
Navigation
Issued 31 May 2001
Resolved
INSTALL PUBLIC ADDRESS SYSTEM ON VESSEL.
Condition: Unknown
Due 31 May 2001
Resolved 31 May 2001
Construction/Loadline
Issued 31 May 2001
Resolved
PAINT DRAFT MARKS IN CONTRASTING COLOR TO THE HULL.
Condition: Unknown
Due 31 May 2001
Resolved 31 May 2001
Deck/Cargo
Issued 16 March 2000
Resolved
Povide and install anchor windlass on forecastle deck.
Condition: Unknown
Due 16 March 2000
Resolved 16 March 2000
Accommodation/Occupational Safety
Issued 19 March 1999
Resolved
REPLACE HOT WATER HEATER RELIEF VALVE WITH 100 PSI RELIEF VALVE.
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Electrical
Issued 21 August 1998
Resolved
PROPERLY ATTACH LIGHTING WIRING IN OVERHEAD, PORT LAZARETTE.
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Construction/Loadline
Issued 21 August 1998
Resolved
C/R THREE TRIPPED SIDESHELL LONGITUDINAL FRAMES AND ASSOCIATED GUSSETS IN PORT AFT CORNER IN LAZARETTE. WRAP AROUND TO BE C/R IF NECESSARY.
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Lifesaving
Issued 20 May 1998
Resolved
REPLACE WATERLIGHT LANYARD ON PORT SIDE LIFE BUOY WITH PROPER LENGTH AND WITH PROPER CLIP.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Accommodation/Occupational Safety
Issued 20 May 1998
Resolved
RE-STENCIL PILOTHOUSE EMERGENCY ESCAPE HATCH AND REPAIR DOGS.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Engineering
Issued 20 May 1998
Resolved
RENEW AS NECESSARY ALL WASTED EXHAUST LAGGING ON ALL MDE's AND BOTH GENERATORS.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Engineering
Issued 20 May 1998
Resolved
REPAIR HOLE IN STBD MDE EXHAUST.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Construction/Loadline
Issued 20 May 1998
Resolved
SUBMIT PLANS SHOWING TANK SIZE CHANGES FOR NEW POTABLE WATER TANK.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Electrical
Issued 20 May 1998
Resolved
RELINE/REPAIR BATTERY BOX UNDER CONSOLE. REPAIR UNJACKETED WIRES.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Engineering
Issued 1 May 1997
Resolved
PROVIDE & TEST RELIEF VALVE FOR STBD AIR RECEIVER.
Condition: Unknown
Due 7 May 1997
Resolved 7 May 1997
Electrical
Issued 1 May 1997
Resolved
PROVIDE PROPER CORD FOR FREEZER.
Condition: Unknown
Due 7 May 1997
Resolved 7 May 1997
Construction/Loadline
Issued 1 May 1997
Resolved
MAKE PERMANENT REPAIRS TO SIDESHELL IN WAY OF STBD EXHAUST.
Condition: Unknown
Due 7 May 1997
Resolved 7 May 1997
Lifesaving
Issued 1 May 1997
Resolved
PROVIDE APPROPRIATE SIZED WEAK LINK FOR PORT SIDE LIFEFLOAT.
Condition: Unknown
Due 7 May 1997
Resolved 7 May 1997
Construction/Loadline
Issued 18 October 1996
Resolved
Gouge and reweld cracks at manhole cover to forepeak.
Condition: Unknown
Due 18 October 1996
Resolved 18 October 1996
Construction/Loadline
Issued 18 October 1996
Resolved
Reweld cracked welds (3) in forepeak as marked
Condition: Unknown
Due 18 October 1996
Resolved 18 October 1996
Construction/Loadline
Issued 18 October 1996
Resolved
Reweld cracks in lazerette as marked.
Condition: Unknown
Due 18 October 1996
Resolved 18 October 1996
Engineering
Issued 21 March 1996
Resolved
Tighten packing gland for stbd stern tube in engine room.
Condition: Unknown
Due 21 March 1996
Resolved 21 March 1996
Accommodation/Occupational Safety
Issued 21 March 1996
Resolved
Provide screen/cover for galley range.
Condition: Unknown
Due 21 March 1996
Resolved 21 March 1996
Lifesaving
Issued 21 March 1996
Resolved
Provide electrical safety mat for generator switchboard.
Condition: Unknown
Due 21 March 1996
Resolved 21 March 1996
Construction/Loadline
Issued 21 March 1996
Resolved
Provide plug for a/c drain overboard piping in void #4 portside.
Condition: Unknown
Due 21 March 1996
Resolved 21 March 1996
Electrical
Issued 21 March 1996
Resolved
Prove proper operation of e/r watertight door indicator in pilothouse.
Condition: Unknown
Due 21 March 1996
Resolved 21 March 1996
Engineering
Issued 21 March 1996
Resolved
Provide marine approved hose for L/O fill line in lazarette.
Condition: Unknown
Due 21 March 1996
Resolved 21 March 1996
Navigation
Issued 21 March 1996
Resolved
Provide current Coast Pilot [name withheld], Tide/Current Tables and up-to-datechart 11361.
Condition: Unknown
Due 21 March 1996
Resolved 21 March 1996
Electrical
Issued 20 October 1994
Resolved
INSTALL LIGHT GLOBES AND GUARDS IN AFT STEERING.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Construction/Loadline
Issued 20 October 1994
Resolved
REPAIR SIDE SHELL FRACTURE AFT STEERING PORT SIDE AFT OF LADDER APPROX 1 FTFROM DECK.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Deck/Cargo
Issued 20 October 1994
Resolved
REPAIR AND MAKE FAST FRESH WATER TANK IN AFT STEERING.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Construction/Loadline
Issued 20 October 1994
Resolved
REPAIR FRACTURED THRU HULL PENETRATION ON STBD GENERATOR EXHAUST.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Construction/Loadline
Issued 20 October 1994
Resolved
REPAIR BULL WORK AND RAIL ON BOW AS ORIGINAL.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Engineering
Issued 20 October 1994
Resolved
REPLACE PORT AND STBD SEA SUCTION STRAINERS.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Construction/Loadline
Issued 20 October 1994
Resolved
CROP AND RENEW DECK AT STBD AMIDSHIPS BIT AS ORIGINAL. APPROX 36"x24" INSERT.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Construction/Loadline
Issued 14 April 1994
Resolved
MAKE PERMANENT REPAIRS TO CRACKED WELDS AND HOLES IN STERN BULKHEAD, PORT AND STARBOARD.
Condition: Unknown
Due 14 April 1994
Resolved 14 April 1994
Electrical
Issued 14 April 1994
Resolved
RENEW/REPLACE WORN SHORE POWER CABLE IN ENGINE ROOM.
Condition: Unknown
Due 14 April 1994
Resolved 14 April 1994
Documentation
Issued 6 May 1993
Resolved
OBTAIN STBILITY LETTER FOR INTENDED ROUTE (OCEANS SERVICE)_x001C_
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Navigation
Issued 6 May 1993
Resolved
OBTAIN/INSTALL SECOND VHF TRANSMITTER/RECEIVER.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Documentation
Issued 6 May 1993
Resolved
PRESENT FOR INSPECTION FCC STATION LICENSE.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Electrical
Issued 6 May 1993
Resolved
INSTALL COVER ON ELECTRICAL JUNCTION BOX TO ENGINE RM WATER HTR.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Lifesaving
Issued 6 May 1993
Resolved
OBTAIN/INSTALL CLASS "A" EPIRB MANUFACTURED ON OR AFTER 1OCT88 OR A 406 MHZSATELLITE EPIRB.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Navigation
Issued 7 May 1992
Resolved
REPLACE OPAQUE, DISCOLORED NAVIGATIONAL SIDELIGHTS
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Engineering
Issued 7 May 1992
Resolved
INSTALL PROTECTIVE GUARDS AT FIRE AND BILGE PUMPS
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Engineering
Issued 7 May 1992
Resolved
INSTALL PROTECTIVE GUARDS AT PORT GENERATOR AND CENTER MAIN ENGINES
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Electrical
Issued 7 May 1992
Resolved
REPLACE INCORRECT WHEELHOUSE PANEL FUSES
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Electrical
Issued 7 May 1992
Resolved
REPAIR/REPLACE INOPERATIVE ENGINE ROOM LIGHT FIXTURES
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Accommodation/Occupational Safety
Issued 7 May 1992
Resolved
STENCIL MARKINGS AT FORWARD ACCOMODATION SPACE AND ENGINE ROOM EMERGENCY EXITS IN ACCORDANCE WITH 46 CFR 185.30-15.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Construction/Loadline
Issued 7 May 1992
Resolved
REPAIR DECK PLATE FRACTURE AT STBD BOW MOORING BITT
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Electrical
Issued 7 May 1992
Resolved
PROVE PROPER OPERATION OF ENGINE ROOM DOOR CLOSURE INDICATOR
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Lifesaving
Issued 7 May 1992
Resolved
INSTALL NON-CONDUCTIVE FLOOR MAT AT ENGINE ROOM DISTRIBUTION PANEL
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Accommodation/Occupational Safety
Issued 7 May 1991
Resolved
INSTALL AND DEMONSTRATE PROPER OPERATION OF BOTH PRESSURE RELIEF VALVES ON SHIP'S SERVICE AIR TANKS (P/S) TO COGNIZANT OCMI.
Condition: Unknown
Due 7 May 1991
Resolved 7 May 1991
Navigation
Issued 12 September 1990
Resolved
PROVIDE UPDATED TIDE TABLE AND TIDAL CURRENT PUBLICATION.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Lifesaving
Issued 12 September 1990
Resolved
PROVIDE 2 CHILD PFDS VESSEL RESTRICTED TO 13 CHILDREN UNTIL CLEARED.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Construction/Loadline
Issued 12 September 1990
Resolved
DEMONSTRATE PROPER OPERATION OF ENGINE ROOM WATER TIGHT DOOR WARNING LIGHT.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Engineering
Issued 29 September 1989
Resolved
HYDROTEST BOTH AIR RECEIVERS TO 1.25 TIMES MAXIMUM ALLOWABLE WORKING PRESSURE.
Condition: Unknown
Due 29 September 1989
Resolved 29 September 1989
Construction/Loadline
Issued 13 September 1989
Resolved
REPAIR CRACKS OR RENEW SEATING RING ON ALL THREE DECK ACCESS HATCHES.
Condition: Unknown
Due 13 September 1989
Resolved 13 September 1989
Construction/Loadline
Issued 13 September 1989
Resolved
REPAIR CRAKCS WHERE PORT AND STARBOARD EXHAUST COVER BOXES ATTACHED TO HULL
Condition: Unknown
Due 13 September 1989
Resolved 13 September 1989
Fire Fighting
Issued 5 September 1989
Resolved
PROVIDE NEW 1 1/2 FIRE HOSE.
Condition: Unknown
Due 5 September 1989
Resolved 5 September 1989
Lifesaving
Issued 5 September 1989
Resolved
PROVIDE LINE FROM FLOATING APPARATUS TO WATERLIGHT.
Condition: Unknown
Due 5 September 1989
Resolved 5 September 1989
Lifesaving
Issued 5 September 1989
Resolved
PROVIDE 6 HAND FLARES AND 6 HAND SMOKE SIGNALS.
Condition: Unknown
Due 5 September 1989
Resolved 5 September 1989
Construction/Loadline
Issued 21 June 1989
Resolved
REPAIR CRACKS OR RENEW SEATING RING ON ALL THREE MAIN DECK ACCESS HATCHES.
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Construction/Loadline
Issued 21 June 1989
Resolved
REPAIR CRACKS WHERE PORT AND STBD EXHAUST COVER BOXES ATTACH TO HULL.
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Lifesaving
Issued 24 August 1988
Resolved
REPLACE OR REPARI WORN LIFEFLOAT. SHELL HAS NUMEROUS CRACKS IN IT.
Condition: Unknown
Due 24 August 1988
Resolved 24 August 1988
Electrical
Issued 11 September 1987
Resolved
PROVIDE OPERATIONAL TEST OF OVERSPEED TRIPS ON 2 AUX. GENERATORS, PRESENTLYINOPERATIVE.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Fire Fighting
Issued 11 September 1987
Resolved
REPLACE ONE 50' LENGTH OF 1&1/2" FIRE HOSE WHICH RUPTURED DURING TESTING.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Engineering
Issued 19 September 1986
Resolved
PROVIDE DOCUMENTATION FROM MANUFACTURERS REPRESENTATIVE TO ATTEST TO THE SAFETY OF THE MAIN DIESEL ENGINES (3 EACH) IN THEIR PRESENT CONDITION. (IN REFERENCE TO THE REMOVABLE AIR BOX FLAPPERS.)
Condition: Unknown
Due 19 September 1986
Resolved 19 September 1986
Accommodation/Occupational Safety
Issued 19 September 1986
Resolved
EXTEND HAND RAIL HEIGHT UP TO 42 INCHES WITH ACCOMPANYING BULWARKS, CHAIN LINK FENCING, WIRE MESH OR THE EQUIVALENT (46 CFR 177.35-1(C) (REFER TO SPECIAL NOT AT THE BOTTOM OF THIS FORM.
Condition: Unknown
Due 19 September 1986
Resolved 19 September 1986