Records from 2010 to 2023. Most recent: inspection, 6 June 2023.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 June 2023
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The annual inspection anniversary date for the [name withheld] is February 15 and the annual inspection has not been scheduled to be completed by May 15.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2023
Resolved 6 June 2023
Resolution: Annual Inspection conducted on 06JUN2023.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 June 2023
Resolved
At each inspection, all generators, motors, lighting fixtures, and circuit interrupting devices shall be checked. Oil leaks identified on both port and starboard generators. Repair.
46 CFR 176.25-15
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 6 June 2023
Resolved 29 June 2023
Resolution: Oil leaks fixed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 June 2023
Resolved
Except as otherwise provided in this section, vessels in ocean service shall carry sufficient life floats for all persons on board. Vessel found with missing 24-person life float. Replace or provide appropriate life float to meet COI requirement.
46 CFR 180.10-5(a)
Action required: 60 - Rectify deficiencies prior to movement
Due 6 June 2023
Resolved 29 June 2023
Resolution: Life float replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 June 2023
Resolved
Main steering apparatus shall be tested for operation and inspection shall examine mechanism. Port rudder mechanical stops did not function as required, allowing rudder to continue to travel by shifting the mounting arrangements. Conduct needed repairs of steering system.
46 CFR 176.25-35(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2023
Resolved 30 June 2023
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 June 2023
Resolved
At each inspection, view vessel afloat and examine all visible parts of the exterior and interior of the hull. In forepeak IVO frwd centerline, an 8" section of side shell plate was missing the interior weld seam. Complete weld on plate.
46 CFR 176.25-5(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2023
Resolved 29 June 2023
Resolution: Plate welded.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 6 June 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Multiple box lighting fixtures in engine room found inoperable. Replace or repair fixtures.
46 CFR 183.01-15(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 June 2023
Resolved
Vessels shall be equipped with a suitable number of portable battery lights. Vessel’s portable lights found inoperable in engine room. Replace or repair.
46 CFR 184.30-1(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Starboard spotlight found inoperable. Replace or repair.
46 CFR 183.01-15(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Abandoned dead end wires found in old through hull fitting from previous transducer. Remove.
46 CFR 183.01-15(a)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2023
Resolved
At each inspection, examine and test the following items: (1) Electrical cable. The cable shall be examined as far as practicable without undue disturbance of the cable or electrical apparatus. Multiple dead end wires found underneath operating station console. Replace or repair.
46 CFR 176.25-15(a)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2023
Resolved
At each inspection, examine and test the following items: (4) Generators, etc. All generators, motors, lighting fixtures and circuit interrupting devices shall be checked. DC charger under operating station console not mounted properly. Fasten and mount charger correctly.
46 CFR 176.25-15(a)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 June 2023
Resolved
At each inspection, the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Perko switch from battery to generator found incorrectly fastened. Mount correctly.
46 CFR 176.25-50(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Main distribution panel found missing directory to each associated system. Provide labeling or directory.
46 CFR 183.01-15(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 June 2023
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit found with expired aspirin. Replace.
46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2023
Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Three life preservers found with severely faded retro reflective tape and one life preserver found with a broken float light. Replace retro reflective tape and float light.
46 CFR 180.25-5 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 6 June 2023
Resolved
The master of each vessel subject to this subpart shall ensure that suitable public announcements, instructive placards or both are provided with… Proper method of donning and adjusting life preservers of the type(s) carried on the vessel. Vessel missing four life jacket donning placards for the types that are carried onboard. Post correct placards.
46 CFR 185.25-1(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 June 2023
Resolved
All life floats and buoyant apparatus shall be conspicuously marked with the vessel’s name. In addition the number of persons allowed on each life float or buoyant apparatus shall be conspicuously marked. Severely faded markings identified on lifefloats. Appropriately remark lifefloats.
46 CFR 180.20-5(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 June 2023
Resolved
Each life float shall be fitted with a life line and shall be equipped with two paddles, a water light and a painter. Water light attached to life float found broken. Replace or repair.
46 CFR 180.15-1(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 6 June 2023
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. Public address system found inoperable. Replace or repair.
46 CFR 184.610(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 6 June 2023
Resolved
The licensed individuals employed upon any vessel subject to the provisions of this subchapter shall have their license in their possession and available for examination at all times. Master medical certificate found expired. Provide valid medical certificate.
46 CFR 185.10-1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 June 2023
Resolved
Each vessel in ocean and coastwise service must have an approved Class A emergency position indication radiobeacon (EPIRB) that is ---(1) Operative. Vessel rep unable to satisfactorily test EPIRB to show operative condition. Replace or repair.
46 CFR 180.40-1(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 June 2023
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1- inch letters: "Emergency Exit, Keep Clear." The markings found on the FWD Emergency exit in passenger space were small and sun damaged, making them difficult to read. Remark.
46 CFR 185.40-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2023
Resolved
At each inspection, the setting of the relief valves on unfired pressure vessels shall be checked. Unable to verify relief valves settings for Port/Starboard UPVs.
46 CFR 176.25-32(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 30 June 2023
Resolution: Vessel rep installed proper safety relief valves
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 June 2023
Resolved
At each inspection, view vessel afloat and examine all visible parts of the exterior and interior of the hull. In forepeak IVO hatch cover, found weld failures on insert, top aft weld seam. Conduct needed repairs of weld.
46 CFR 176.25-5(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 June 2023
Resolved
At each inspection, view vessel afloat and examine all visible parts of the exterior and interior of the hull. In lazerette starboard quarter IVO top round, found weld failures with evidence of water intrusion. Conduct needed repairs of weld.
46 CFR 176.25-5(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 June 2023
Resolved
At each inspection, examine and test the following items: (3) Engine control mechanisms. Port M/E solenoid valve found inoperable. Replace or repair.
46 CFR 176.25-10(a)(3)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Protection machines/parts
Issued 6 June 2023
Resolved
Protective gratings shall be provided at such locations where persons or gear might come in contact with the exhaust pipe. Port generator exhaust piping found missing portions of lagging. Install adequate lagging.
46 CFR 182.15-20(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 June 2023
Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. The no. 2 steering pump found with inadequate levels of hydraulic fluid. Restore hydraulic fluid in pump.
46 CFR 182.30-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 June 2023
Resolved
Minimum capacity of the fire pump shall be at least 60 PSI and pump outlet shall be fitted with a gauge. Gauge was found cracked. Renew.
46 CFR 181.10-1(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 June 2023
Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. Portable fire extinguisher mounts found removed from station. Reattach mounts.
46 CFR 181.30-10(b)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 29 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2023
Resolved
Rigid non-metallic piping is acceptable for non-vital systems. Bilge system throughout vessel has sections of flexible hoses; renew with approved material.
46 CFR 182.40-5(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2023
Resolved 29 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 June 2023
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Interconnected system not functioning as required. Repair.
46 CFR 181.405(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2023
Resolved 29 June 2023
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 December 2022
Resolved
AT EACH INITIAL AND SUBSEQUENT INSPECTION FOR CERTIFICATION OF A VESSEL, THE OWNER OR MANAGING OPERATOR SHALL BE PREPARED TO CONDUCT TESTS AND HAVE THE VESSEL READY FOR INSPECTIONS OF THE HULL STRUCTURE AND ITS APPURTENANCES, INCLUDING THE FOLLOWING: INSPECTION OF ALL ACCESSIBLE PARTS OF THE EXTERIOR AND INTERIOR OF THE HULL, THE WATERTIGHT BULKEADS, AND WEATHERTIGH BULKHEADS. WHILE CONDUCTING AN INSPECTION OF THE HULL, THE MARINE INSPECTOR IDENTIFIED A 6-9" SHARP INSET ON THE PORT BOW THAT GOES DIRECTLY INTO THE FOREPEAK. MARINE INSPECTIOR REQUIRES FOR THE VESSEL TO REPLACE IN KIND.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 29 December 2022
Resolved 12 January 2023
Resolution: Inspected interior and exterior welded insert in the port bow hull and conducted non-destructive testing with dye penetrant method, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 February 2022
Resolved
Port generator has excessive oil leaks. Make repairs to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 10 March 2022
Resolved 8 March 2022
Resolution: Conducted satisfactory repairs. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 February 2022
Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personal injury.
Port generator windings coated in oil.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 12 March 2022
Resolved 8 March 2022
Resolution: Cleaned generator windings to satisfaction of inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 February 2022
Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personal injury.
Generator mountig bolts not properly secured.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2022
Resolved 8 March 2022
Resolution: Properly secured generator.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 15 February 2022
Resolved
A vessel must be fitted with a Federal Communications Commission (FCC) type accepted general marine radar system for surface navigation with a radar screen mounted at the primary operating station.
Radar is inoperable. Make repairs to the satisfaction of the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2022
Resolved 8 March 2022
Resolution: Radar is operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 February 2022
Resolved
Generators and motors for use in machinery spaces shall generally be designed for an ambient temperature of 50 degrees Celsius.
Both generators are rated at 40 degree Celsius. Generators will need to be derated 80% or prove the generator is adequate to 50 degrees Celsius to the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2022
Resolved 8 March 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 February 2022
Resolved
Examine and test by operation all watertight closures in the hull, decks and bulkheads.
Water tight forward gasket is caulked and not water tight. Make repairs to hatch gasket to the satisfaction of the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2022
Resolved 8 March 2022
Resolution: Gasket was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 February 2022
Resolved
The main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personal injury.
Port and Starboard air receiver relief valve did not operate as designed. Repair or replace to the satisfaction of the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2022
Resolved 8 March 2022
Resolution: Relief valves operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 February 2022
Resolved
The main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personal injury.
Replace oil cooling line, gauge, mechanical guards and remove corrosion to the satisfaction of the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2022
Resolved 8 March 2022
Resolution: Replaced oil cooling line, gauge, and mechanical guards.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 February 2022
Resolved
Each EPIRB must be tested monthly.
No records of EPIRB being tested monthly. Maintain logs for life saving equipment.
Action required: 60 - Rectify deficiencies prior to movement
Due 11 March 2022
Resolved 8 March 2022
Resolution: Provided logs.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 15 February 2022
Resolved
Each survival craft, rescue boat and launching apparatus must be inspected monthly per manufactures instructions.
grab line for life float deteriorated. Replace line, repaint and maintain log of lifesaving equipment maintenance to satisfaction of marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 March 2022
Resolved 8 March 2022
Resolution: Life float satisfactory.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 15 February 2022
Resolved
Junction boxes, connections boxes and outlet boxes for use in damp locations shall be of water tight construction.
Found engine room junction box to be full of water. Check all junction boxes and repair or replace to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Repaired to the satisfaction of the MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2022
Resolved
The generator circuit breakers must be interlocked to prevent the generators from simultaneously connected to the switch board.
Handle for interlock is broken. Repair or replace to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Handle repaired. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2022
Resolved
Equipment is so constructed or protected that is successful operation is not interfered with when subjected to falling moisture, dirt, or uninsulated parts cannot be touched or approached by any person
Breaker panel in engine room has excessive rust Clean or to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Breaker panels cleaned up to satisfaction of MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2022
Resolved
Equipment is so constructed or protected that is successful operation is not interfered with when subjected to falling moisture, dirt, or uninsulated parts cannot be touched or approached by any person
Distribution panel in galley is missing blanks. Install blanks where breakers are missing to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Installed blanks.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2022
Resolved
Equipment is so constructed or protected that is successful operation is not interfered with when subjected to falling moisture, dirt, or uninsulated parts cannot be touched or approached by any person
Galley hood light is missing guard. Replace guard to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Installed guard for lights.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 15 February 2022
Resolved
shall be fitted with matt black inboard screens and meet the requirements of § 84.15.
VSL was not fitted with matt black. Paint to satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Matte black navigation light background.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 February 2022
Resolved
This part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personal injury.
all three reduction gear PSI gauges inoperative. Repair or replace to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Replaced PSI gauges on reduction gear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 February 2022
Resolved
This part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personal injury.
Witnessed multiple twisted hoses on machinery. Repair or replace hoses to satisfaction of marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Repaired machinery hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 February 2022
Resolved
This part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personal injury.
MDE fuel filter crimped. Replace to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Fuel filter replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2022
Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected.
Washer and Dryer were not secured for sea. Secure to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Washer and dryer secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2022
Resolved
Vessel shall be inspected for compliance with the standards required by this subchapter. For items not covered by these standards inspections shall be in accordance with with standards acceptable to the OCMI as good marine practice.
Vsl did not have collection system for dryer vent.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 8 March 2022
Resolution: Installed collection for dryer vent.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 January 2022
Resolved
At each inspection for a vessel, all observed unsafe practices must be corrected; there was significiant oil accumulation in the engine room bilges.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2022
Resolved 15 February 2022
Resolution: Oil was cleaned up upon inspection.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 January 2022
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape; emergency lights leading out of the engine room were inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2022
Resolved 15 February 2022
Resolution: Emergency lights were operable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 January 2022
Resolved
Each distribution panel must be totally enclosed and of the deadfront type; breaker panel in the galley was completely exposed.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2022
Resolved 15 February 2022
Resolution: Panel was secured.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 January 2022
Resolved
All navigation lights must be in compliance with the inland and international navigation rules; all navigations lights are inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2022
Resolved 15 February 2022
Resolution: Navigation lights are operable.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 January 2022
Resolved
The master or owner shall ensure that crewmembers, prior to getting underway and at least once every three months, are instructed in the duties in the event of an emergency; drills have been irregularly logged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2022
Resolved 15 February 2022
Resolution: Created logs and plan for drills.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 January 2022
Resolved
Each inspection must include an inspection of the ship's lifesaving equipment; lifefloats had unapproved retro-reflective tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2022
Resolved 15 February 2022
Resolution: Retro was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 January 2022
Resolved
The master shall ensure that monthly EPIRB checks are completed; EPIRB checks have not been logged.
Action required: 10 - Deficiency Rectified
Due 13 January 2022
Resolved 13 January 2022
Resolution: Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 July 2021
Resolved
At each inspection the marine inspector shall examine the bilges and other spaces to see hat there is no accumulation of oil or other matter which might create a fire hazards. Discovered fuel leaking from port generator fuel return line. Make proper repairs to the satisfaction of the attending marine inspector.
46CFR176.25-50(b)
(old T)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 October 2021
Resolution: located and tightened a loose compression union on port generator fuel return line
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Water, pipes, tanks
Issued 15 July 2021
Resolved
All pressure vessels shall be subject to hydrostatic test of 1 1/4 times the maximum allowable working pressure. Discovered excessive corroding of both port and starboard start air compressor tanks. Conduct hydrostatic test and provide report to the attending marine inspector.
46CFR176.25-30(b)(4)
(Old T)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 September 2021
Resolution: Sept 28th 2021 performed hydrostatic pressure test on both port and starboard air receivers on [name withheld] both receivers from vessel and plugged all ports. Filled with water and pressured up to 225 psi. no leaks
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 15 July 2021
Resolved
All vessels shall be provided with two means of escape from all general areas. Emergency escape hatch to the bow was not maintained and dogs were inoperable, rectified before inspection finished.
46CFR177.15-1(a)
(Old T)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 July 2021
Resolved
Life floats stowed in tiers must be kept apart by spacers. Provide pictures of spacers installed between tier stowed life floats.
46CFR180.20-1(a)(7)
(Old T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2021
Resolved 13 October 2021
Resolution: inserted wood spacers between stowed life floats
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 July 2021
Resolved
Each class one door on a vessel in ocean service must be designed to withstand a head of water equivalent to a depth from the sill of the door to the margin line. Engine room door seal was damaged due to improper adjustment of the dogs. Provide proof of proper adjustment to the satisfaction of the attending marine inspector.
46CFR170.270(b)
(Old T)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 October 2021
Resolution: replaced hinges on engine room door to provide proper alignment of door to door opening. Adjusted dogs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 July 2021
Resolved
On metal vessels all frames of major electrical equipment shall be permanently grounded. Grounding strap for starboard generator was severed. Provide pictures of new grounding strap installed on STBD generator.
46CFR183.05-50(d)
(Old T)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 October 2021
Resolution: installed new grounding strap on Starboard generator
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 15 July 2021
Resolved
The marine inspector shall require that all observed unsafe hazardous situations be corrected. Vessel's hot water heater was severely corroded at the base, conduct maintenance or replace in kind to the satisfaction of the attending marine inspector.
46CFR176.25-50(a)
(Old T)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2021
Resolved 13 October 2021
Resolution: cleaned surface rust, inspected and painted water heater
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 July 2021
Resolved
The master shall conduct drills and give instructions as necessary to ensure that all crew are familiar with their duties. Vessel has been laid up and no drills or maintenance conducted. Provide records of drills and maintenance prior to operation.
46CFR185.25-10
(Old T)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2021
Resolution: vessel provided proof of drills
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 25 June 2021
Resolved
The marine inspector shall require that all observed unsafe hazardous situations be corrected. Forward passenger seating compartment had water ingress from leaking windows saturating the particle board life vest storage bin/seating. Prove proper repairs to compartment windows stopping the ingress of water to the satisfaction of the attending marine inspector.
46CFR176.25-50(a)
(Old T)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2021
Resolution: Vessel provided pictures of repairs to the crew window in question, proof of repairs accepted
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 July 2018
Resolved
Fire pump un-able to gain prime.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2018
Resolved 2 August 2018
Resolution: Witnessed adequate priming, pressure, and satisfactory operation of fire pump / fire main system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2018
Resolved
Centerline main engine has major F/O leak on PORT side cylinder head. 1 drop per 5 seconds.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2018
Resolved 2 August 2018
Resolution: Verified repair to centerline engine; witness satisfactory leak-free operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2018
Resolved
STBD main engine air sep is leaking oil onto Inboard exhaust manifold.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2018
Resolved 2 August 2018
Resolution: Verified repair of STBD MDE; witnessed satisfactory leak-free operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 July 2018
Resolved
PORT GENSET un-able to hold ships load.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2018
Resolved 2 August 2018
Resolution: Witnessed Port Genset under load with no issues.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2018
Resolved
PORT Main engine F/O suspply line leaking fuel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 2 August 2018
Resolution: Verified fuel line fitting / tubing was remade and witnessed leak free operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2018
Resolved
STBD Main engine has exhaust leak on compressor side of turbo.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 2 August 2018
Resolution: Verified repair to gasket on turbocharger; witnessed leak-free operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 July 2018
Resolved
Steering fluid leak in steering space overhead tubing. 1 drop every 10 seconds
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 2 August 2018
Resolution: Section of hydraulic steering tubing was replaced and fittings retightened; Witnessed leak-free operation of steering system.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 19 July 2018
Resolved
Vessel only has life float capacity for 53 persons. COI states 56 persons. vessel has been reduced to carry 53 persons until corrected.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 2 August 2018
Resolution: Vessel removed incorrect Life float and replaced in kind with adequate life float.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 July 2018
Resolved
PORT battery bank has loose terminal
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 2 August 2018
Resolution: Verified all terminals on port battery bank were properly secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2018
Resolved
PORT Main engine exhaust discharge hose missing clamp on through hull fitting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 2 August 2018
Resolution: Second clamp was installed.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 10 May 2017
Resolved
Do not operate vessel more than 20 miles offshore until both the VHF-DSC and MF-DSC radios are functioning properly and verified to the satisfaction of attending marine inspector. 47 CFR 80.905
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 27 June 2017
Resolution: Reviewed docs and tested radio. All sat.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 11 April 2017
Resolved
Replace gauge on port side air receiver and conduct safety relief valve test to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 20 April 2017
Resolution: Witnessed replaced gauge on port side air receiver and observed satisfactory safety relief valve test.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 11 April 2017
Resolved
Repair aft port side ventilation and demonstrate to the satisfaction of attending Marine Inspector ability to close ventilation.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 20 April 2017
Resolution: Observed properation operation of ventilation on port aft of vessel.
Engineering › Steering Gear System › Hydraulic Hose
Issued 11 April 2017
Resolved
Replace hydraulic lines in steering compartment to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 20 April 2017
Resolution: Verified replaced hyrdaulic lines and expected for condition and leaks. All sat.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 11 April 2017
Resolved
Conduct Man Overboard Drill to the satisfaction of attending Marine Inspector.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 20 April 2017
Resolution: Conducted underway drills to the satisfaction of Attending CG Marine Inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 August 2016
Resolved
Vessels lower not under command nav light is cocked and needs proper installation.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 4 August 2016
Resolution: Light bracket repositioned
Electrical › Electric Generation Source (service) › Generator
Issued 28 June 2016
Resolved
Oil leak at governor area
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Oil leak corrected.
Electrical › Electric Generation Source (emergency) › Generator
Issued 28 June 2016
Resolved
Both generators are missing safety guards over front pulley
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Installed guards.
Engineering › Pressure Vessel › Relief Valve
Issued 28 June 2016
Resolved
Relief valves and data plates are painted over on both air receivers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Renewed nameplate and relief valves.
Engineering › Fuel Oil Service System › Hose
Issued 28 June 2016
Resolved
fuel tank bonding strap for fuel fill is broken and tank top has fuel on top.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Bonding strap installed and fuel removed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 June 2016
Resolved
Battery box has oil in it and improper terminal connector installed
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Battery connections corrected and oil removed from battery box.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 28 June 2016
Resolved
Excessive oil leak from top of cylinder head
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Oil leak corrected
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 28 June 2016
Resolved
MDE junction boxes have dead end wires and loose connections
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Dead end wires removed.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 28 June 2016
Resolved
RPM gauge removed with dead end wires hanging loose
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Gage wires removed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 28 June 2016
Resolved
missing lagging on exhaust piping
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Lagging installed.
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 28 June 2016
Resolved
improper installation of jacket water high temp alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Main Eng J/W sensors relocated and properly installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 28 June 2016
Resolved
hydraulic diverter valve above port engine excessive oil leak
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Diverter valve replaced.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 28 June 2016
Resolved
Various smoke detectors disabled and various non authorized detectors
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: New detectors installed throughout.
Operations/Management › Vessel Activity › Other
Issued 28 June 2016
Resolved
Various chemicals and cleaning agents located through out ship and not properly stored
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Chemicals removed or properly stowed.
Communications › Public Address System › Announcing Station
Issued 28 June 2016
Resolved
P/A system not funcyioning properly
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: P/A system repaired.
Engineering › Bilge Water Management System › Not Operational
Issued 28 June 2016
Resolved
Bilge pump system not functioning properly
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Bilge pump repaired and tested.
Fire Fighting › Fire Pumps › Pressure
Issued 28 June 2016
Resolved
Fire pump not operating properly
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2016
Resolution: Fire pump repaired and tested.