Records from 2007 to 2026. Most recent: inspection, 26 May 2026.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 May 2026
Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. Both fuel shutoff valves are not fully closing.
46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2026
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 26 May 2026
Resolved
The EPIRB's battery is replaced after it is used or before the date required by FCC regulations. EPIRB battery has expired.
46 CFR 185.728(b)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 May 2026
Resolved
All machinery and equipment must be installed and maintained in such a manner as toafford adequate protection from causing machinery failure. STBD side exhaust cooling has a small water leak.
46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 May 2025
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including installation certificates to be issued by the FCC. 46 CFR 184.502
Correct call sign on FCC Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2025
Resolved 27 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2025
Resolved
A vessel must carry one floating waterlight approved in accordance with 161.010 subchapter Q.
Repair/replace intermitantly operating float light.
46 CFR 180.70 (d)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2025
Resolution: Float light replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 May 2025
Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. 46 CFR 183.350(b)
Install battery lids and secure to prevent shifting.
Action required: 705 - Other - as specified
Due 22 May 2025
Resolved 22 May 2025
Resolution: Battery lids and retaining straps installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 May 2025
Resolved
Where a flexible fill pipe section is a nonconductor of electricity, the metallic sections of the fill pipe separated must be joined by a conductor for protection against generation of a static charge when filling with fuel.
Install bonding wires on fuel tank fill neck where required.
46 CFR 182.445(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 June 2025
Resolution: Vessel O/O emailed photos of bonding wire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 May 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure. While conducting sea trials, port MDE shutdown twice. Determine root cause and repair to the satisfaction of the CG Marine Insp.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2024
Resolution: Root cause determined. Sea trial conducted for 1.5 hours.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2024
Resolved
The bilge pump listed by an independent laboratory as meeting the requirements in UL 1113 must be provided. Forward bilge pump not UL listed. Listing of aft bilge pump could not be verified due to worn markings. Provide appropriate submersible bilge pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2024
Resolution: Verified new bilge pump installation.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 May 2024
Resolved
On a vessel of at least 26' in length, a visual and audible alarm must be provided at the operating station to indicate a high water level...Bilge high level alarm for the forward fuel tank void did not produce an audible alarm when tested. Repair and provide proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2024
Resolution: Audible alarm tested - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2024
Resolved
A positive shutoff valve must be installed at the hull penetration. Engine room electric submersible pump for the bilge did not have a positive shutoff valve installed in the line. Properly outfit discharge line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2024
Resolved 14 May 2024
Resolution: Discharge line properly outfitted.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 May 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Adequate number of sterile compression bandages and burn gel missing from first aid kit. Expiry dated items not listed on outside of container.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2024
Resolved 14 May 2024
Resolution: First aid kit properly outfitted and labeled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2024
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Mounted emergency instructions were missing heavy weather procedures. Post appropriate emergency instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2024
Resolved 14 May 2024
Resolution: Emergency instructions posted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 1 May 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. During ise discovered a cracked weld at the port side chine just below the hatch. Submit plans and make permanent repairs to the cracked weld. 46 CFR 177.100
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 May 2023
Resolution: Owner hired a professional welder that gouged and rewelded the crack - all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 1 May 2023
Resolved
Watertight Bulkheads; The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. The fwd engine room bulkhead, portside has two abandoned bulkhead penetrations that is open to the next fwd compartment. Properly seal off bulkhead penetrations. 46 CFR 179.320
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2023
Resolution: Owner sealed off the two bulkhead penetrations (bulk head fitting) by sealing with fire proof/ high temp sealant - all sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 1 May 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Renew expired items eyewash and aspiring. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2023
Resolution: Owner replaced expired first aid items - all sat.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 1 May 2023
Resolved
Emergency instructions.
(a) The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions.
(b) Except when in the judgment of the cognizant OCMI the operation of a vessel does not present one of the hazards listed, the emergency instruction placard should contain at least the applicable portions of the “Emergency Instructions” listed in § 185.512. The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel.
(c) If the cognizant OCMI determines that there is no suitable mounting surface aboard the vessel, the emergency instructions need not be posted but must be carried aboard the vessel and be available to the crew for familiarization. Emergency instructions not posted, properly post emergency instructions visible to crew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2023
Resolution: Owner posted emergency instructions visible to vessels crew - all sat.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 May 2022
Resolved
Vessel is required to have three 2.5 gal fire buckets, with lanyards attached stenciled FIRE BUCKET. Vessel only has two fire buckets onboard. Replace missing fire bucket. 46 CFR 181.610
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 24 May 2022
Resolution: Owner purchased a new fire bucket and placed onboard the vessel with a lanyard and stenciled "FIRE BUCKET" - all sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 12 May 2022
Resolved
Vessel is required to have onboard up to date; Coast Pilot, Light list, Navigation Rules, Charts, tides and currents for all areas the vessel operates. Vessel navigation publications are out of date.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 24 May 2022
Resolution: Owner updated all navigation publications - all sat.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 12 May 2022
Resolved
Vessels EPIRB must be registered with NOAA. Vessels NOAA registration has expired. 46 CFR 184.502
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 13 May 2022
Resolution: Vessels owner text me proof showing that the vessels EPIRB registration has been renewed with NOAA.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2021
Resolved
Remove fuel cocks from main engines fuel filters and install plug.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2021
Resolution: Owner sent photos showing metallic plugs installed into the metallic drain valves.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2021
Resolved
prove proper operation of anchor/stern light
Action required: 10 - Deficiency Rectified
Resolved 13 May 2021
Resolution: fixed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2021
Resolved
Remove all Plastic trash cans and replace with non combustible ones
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2021
Resolution: Owner sent photo showing a metalic garbage can onboard in place of the plastic garbage can.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 May 2021
Resolved
Replace expired hydrostatic release for EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2021
Resolution: vessel has new hydrostatic release
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 June 2020
Resolved
Displace correct hailing port on stern of vessel as listed on the COD
Action required: 705 - Other - as specified
Due 9 June 2020
Resolved 28 July 2020
Resolution: vessel has update hailing port
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2020
Resolved
rovide proof vessel’s crew is enrolled in a drug and
alcohol testing program as per 46 CFR 16.
Action required: 705 - Other - as specified
Due 9 June 2020
Resolved 13 July 2020
Resolution: RCVD Drug testing program with TSS, INC
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2020
Resolved
Provide and post community service hot-line telephone
number for crewmember assistance.
Action required: 10 - Deficiency Rectified
Due 9 June 2020
Resolved 11 June 2020
Resolution: Vessel has posted hotline number
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 9 June 2020
Resolved
Provide FCC Station license for vessel
Action required: 705 - Other - as specified
Due 9 June 2020
Resolved 13 July 2020
Resolution: vessl has station license
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 9 June 2020
Resolved
Provide FCC Radio Safety Telephony Certificate for vessel
Action required: 705 - Other - as specified
Due 9 June 2020
Resolved 28 July 2020
Resolution: Vessel has RCVD FCC Radio Safety Telephony Certificate
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 June 2020
Resolved
Replaced all expired items in the first aid kit
Action required: 705 - Other - as specified
Due 9 June 2020
Resolved 13 July 2020
Resolution: vessel has repalced all expired items
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 June 2020
Resolved
Replaced expired battery in the EPIRB
Action required: 705 - Other - as specified
Due 9 June 2020
Resolved 13 July 2020
Resolution: vessel has replaced battery
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 June 2020
Resolved
Replace expired Battery in life ring bouy.
Action required: 10 - Deficiency Rectified
Due 9 June 2020
Resolved 11 June 2020
Resolution: Vessel has replaced Battery
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 June 2020
Resolved
Provide Charts for the area of operation for vessel
Action required: 705 - Other - as specified
Due 9 June 2020
Resolved 28 July 2020
Resolution: Vessel has charts for AOR.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 9 June 2020
Resolved
Provide guards for all rotating machinery in engine room. Both engines need guards for drive shafts and
pulleys on front of engines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 5 August 2020
Resolution: vessel has installed guards, all sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 June 2020
Resolved
Mark correct hailing port on life ring buoy.
Action required: 705 - Other - as specified
Due 9 June 2020
Resolved 28 July 2020
Resolution: vessel has update hailing port
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 June 2020
Resolved
Replace or remove 2 children’s lifejackets
Action required: 10 - Deficiency Rectified
Due 9 June 2020
Resolved 9 June 2020
Resolution: Vessel removed 2 extra childerns lifejacktes
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 9 June 2020
Resolved
Install Max load mark as per Stability Letter
Action required: 705 - Other - as specified
Due 11 June 2020
Resolved 28 July 2020
Resolution: vessel has installed max load line
Lifesaving › Hand Flares › Quantity
Issued 3 May 2017
Resolved
A vessel on a limited coastwise route must carry six (6) hand red flare distress signals. Vessel only had four (4). 46 CFR 180.68(a)(1) Vessel restricted to 30 minute runs until corrected.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 8 May 2017
Resolution: Rcvd picture of newly acquired flares. Restriction removed.
Construction/Loadline › Hull › Transverse Frame
Issued 3 May 2017
Resolved
Vee & reweld cracked weld IWO TDWF #1 on port side @ chine – space #2.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 June 2017
Resolved 9 May 2017
Resolution: Rcvd pic of repair.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 3 May 2017
Resolved
A vessel must carry adequate & up to date current tables. No current tables aboard. 46 CFR 184.420(a)(5)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2017
Resolved 8 May 2017
Resolution: Rcvd pic of current tables.
Documentation › Logs/Records › MIS Form
Issued 3 May 2017
Resolved
No MIS report available. 46 CFR 16.500(b)(1)
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 June 2017
Resolved 8 May 2017
Resolution: MIS rpt fwd'd to HQ.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 3 May 2017
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers [name withheld] available.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 11 May 2017
Resolution: Reviewed EAP documentation & Supervisory Trng Certificate.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 1 March 2016
Resolved
Various 12v pumps and electrical components are grounded directly to the vessels hull.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 April 2016
Resolved 4 March 2016
Resolution: Owner ran a ground conductor to the main ground bus bar so none of the electrical equipment is grounded to the vessels hull.
Electrical › Electrical Distribution System (service) › Conductor
Issued 1 March 2016
Resolved
Properly terminate dead end wiring in the vessels fuel tank void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2016
Resolved 4 March 2016
Resolution: Owner reconnected dead end live wires to the waste pump motor and tested SAT.
Engineering › Bilge Water Management System › Valve
Issued 1 March 2016
Resolved
Properly install marine grade valve at the discharge on all electric submersible bilge pumps. Bilge pump in the fuel tank void is missing an overboard valve.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 April 2016
Resolved 4 March 2016
Resolution: Owner installed a new marine grade overboard valve for the fuel tank void submersible bilge overboard discharge.