Records from 1986 to 2024. Most recent: inspection, 21 February 2024.
Inspection history · 88
21 February 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7869028
23 May 2023
COI Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7695245
13 May 2023
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7687188
10 April 2023
Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7656543
18 November 2022
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7597007
24 October 2022
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7583194
18 October 2022
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7623273
12 September 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7559208
29 August 2022
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7546665
17 June 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7479840
11 April 2022
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7748795
8 April 2022
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7427527
16 March 2022
COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7412502
24 May 2021
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7205937
13 January 2021
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7124106
18 March 2020
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6928137
9 March 2020
Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6923879
20 March 2019
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6655076
18 April 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6393691
14 March 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6310983
15 March 2017
COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6103931
7 October 2016
Permit to Proceed · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6018509
1 July 2016
Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5926027
29 June 2016
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5930727
14 June 2016
In-Service Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5907704
14 April 2016
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5858902
17 March 2016
Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5835180
24 March 2010
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3699031
5 February 2010
Hull Examination · Examination of Repairs
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3627540
11 May 2009
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3472773
31 July 2008
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3289859
2 April 2008
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3151767
7 February 2008
Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3143504
1 May 2007
COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2919233
28 April 2006
In-Service Inspection · Administrative Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2638789
12 April 2006
Hull Examination · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2621391
14 November 2005
Type not recorded
No type recorded · Station Grays Harbor · USCG Northwest District (CGD-NW) · Activity 2534694
6 April 2005
Annual Inspection · Hull Examination · Examination of Repairs · Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2292896
13 April 2004
Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2045313
10 March 2004
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2018851
3 March 2004
Simplified Stability Test
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1985466
3 April 2003
Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1757454
13 June 2002
Deficiency Check · Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1630440
11 April 2002
Administrative Inspection
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1611724
28 March 2002
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1485701
23 May 2001
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1065115
11 April 2000
Deficiency Check · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1403152
5 April 2000
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 816431
17 July 1999
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 34218
14 June 1999
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 811385
19 May 1999
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 802688
12 April 1999
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1378671
29 March 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1115123
19 March 1998
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1381170
18 August 1997
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 29404
23 April 1997
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1443846
13 June 1996
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 143060
25 April 1996
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1431638
18 April 1996
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1385707
22 June 1995
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1189341
19 April 1995
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1165497
3 April 1995
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1431495
3 March 1995
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 856580
18 October 1994
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 658299
8 August 1994
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 155882
15 April 1994
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1440815
9 March 1994
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1356549
7 October 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 157449
31 March 1993
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 836588
11 March 1993
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 834926
11 March 1993
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1401683
17 April 1992
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1267751
27 February 1992
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1009316
6 August 1991
Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 932416
20 March 1991
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 924630
11 May 1990
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 922779
27 February 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1216270
13 February 1990
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1232509
6 February 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1218023
22 January 1990
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1225675
4 January 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 976173
7 November 1989
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1030913
12 July 1989
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1349595
25 April 1989
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1038279
28 April 1988
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1044387
6 April 1987
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1317768
28 May 1986
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1013042
13 March 1986
Credit Drydock
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 993397
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2023
No resolution recorded
The fixed power bilge pump shall be self-priming and may be driven off the main engine. Identified Port engine driven bilge pump not operational. Prove proper operation of port engine driven bilge pump to attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2023
No resolution recorded
Fuel shutoff valves, installed as to close against the fuel flow shall be fitted in the fuel supply lines, one at the tank connection and one at the engine end. The shutoff valve at the tank shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck. Identified port and stbd fuel shutoff valve ram rod was installed using plastic zip ties and a metal bowl. Prove permanent methods to hold position of fuel shutoff reach rods access from weather deck.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2023
No resolution recorded
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Identified a hydraulic line to the steering wheel inside the cabinet behind the helm at operating station, was leaking onto electrical wires. Repair hydraulic leak and remove residual hydraulic fluid from electrical wires inside cabinet.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 May 2023
No resolution recorded
A suitable hull strainer must be installed in the circulating raw water intake line of an engine cooling system. The lazarette generator’s strainer element is deteriorated and requires replacement.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2023
No resolution recorded
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation. The port engine raw water intake flexible hose between suction and strainer is cracked, split and needs replacement.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 23 May 2023
No resolution recorded
All vessels except non-self propelled vessels shall be provided with suitable steering apparatus. Identified STBD steering gear mounted to board with inadequate hardware. Requires installation of proper length hardware and nuts.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2023
No resolution recorded
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Identified engine room bilge audible alarm was not functioning properly and was emitting erratic alarms at the operating station. Repair erratic alarm and prove proper operation to marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 23 May 2023
No resolution recorded
Except for engine exhausts, each inlet or discharge pipe that penetrates the hull 6 inches above the deepest waterline must have means to prevent water from entering the vessel if the pipe fractures or fails. Identified plastic cap on a thru hull fitting IVO Port side amidships. Replace plastic cap on pipe penetration with suitable metallic cap. 46CFR171.119(b)
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 May 2023
No resolution recorded
Each lifejacket carried on a vessel on oceans, coastwise route must have a life jacket light IAW 161.012. Light must be securely attached to front shoulder area of life jacket. Identified 15 lifejackets with inoperable lights and attached in wrong location. Prove proper operation of all life jacket lights.
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 May 2023
No resolution recorded
Each ring life buoy must be marked in clearly legible block capital letters with the vessel’s name. Identified ring life buoy was not satisfactorily marked, retroreflective tape was found unsatisfactory and tear in seam. Replace with new life ring.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2023
No resolution recorded
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Identified ECM was unsatisfactorily zip tied to STBD Engine. Permanently affix ECM to STBD Engine. 46CFR183.01-15
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 May 2023
No resolution recorded
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Identified dead end wires behind steering console and in vicinity of VHF radio at the helm. 46CFR183.01-15
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2023
No resolution recorded
Protect crew, or other persons and the vessel from electrical hazards, including fire and electrical shock. Install protective covers over positive terminals of the battery installations.
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 May 2023
No resolution recorded
A vessel must carry either a first aid kit approved under 160.041 or a kit with equivalent contents. First aid kit expired, replace expired components
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 23 May 2023
No resolution recorded
The USCG will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners, will be issued for a maximum period of 5 years. Master of vessel is to provide proof of medical certificate to attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 May 2023
No resolution recorded
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board. No alcohol testing strips were on board. Provide sufficient number of alcohol test strips.
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 May 2023
No resolution recorded
Portable extinguishers must be inspected and maintained in accordance with NFPA 10 Annually. Identified portable extinguisher in the forward lower compartment had not received annual servicing. Provide evidence of serviced fire extinguisher as required by COI.
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 May 2023
No resolution recorded
EPIRB must be tested monthly. No records or logs of testing were available for EPIRB. Create new logbook to document monthly testing of EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 May 2023
No resolution recorded
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. No drill logs were available. Create new logbook for completing drills.
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 May 2023
No resolution recorded
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. No drill logs were available. Create new logbook for completing drills.
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 May 2023
No resolution recorded
Portable fire extinguisher monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. No records of inspection were available for vessel to maintain monthly checks. Create new logbook for completing required monthly interval inspection.
Action required: 701 - Prior to carriage of passengers/cargo
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 May 2023
No resolution recorded
As appropriate for the intended voyage, a vessel must carry adequate and up to date publications: U.S. Coast Pilot [name withheld] List and Navigation Rules were not onboard. Provide current publications for vessel’s intended route.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 November 2022
Resolved
All vessels...shall be provided with suitable steering apparatus. MIs found the steering gear mounted to a wooden board. The board had multiple severe cracks in it. Ensure the steering gear is mounted to a secure foundation and demonstrate proper operation to the satisfaction of the attending MI.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 12 April 2023
Resolution: Verified renewal of wood plank steering foundations; however, updated deficiency to reflect the requirement for additional foundation supports.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 November 2022
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. The bilge high level alarm in the lazarette was found lying on the bottom of the bilge. There was also standing water in the space and no alarm on the bridge. Demonstrate proper operation of bilge alarm in the lazarette.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 23 May 2023
Resolution: Lazarette bilge alarm reinstalled, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 November 2022
Resolved
Each…pipe that penetrates the hull below [the waterline] must have means to prevent water from entering the vessel. The owner stated that the heat exchanger on the generator had failed. MIs observed a stream of water coming from the generator and filling the bilge. Ensure proper repairs are made to the generator to prevent water ingress to the lazarette.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 23 May 2023
Resolution: Heat exchanger replaced, ops check good, no water leakage.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 November 2022
Resolved
Exhaust piping…shall be gas-tight throughout its length. MIs observed exhaust smoke in the engine room space. Ensure proper repairs are made to prevent exhaust leaks.
Action required: 30 - Ship detained
Resolved 23 May 2023
Resolution: Exhaust leaks repaired, ops check good.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 18 November 2022
Resolved
A periodic examination…shall include the throughhull fittings…and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Amidship, stbd thru-hull fitting above the waterline is broken and a possible ingress point for water. Replace.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 12 April 2023
Resolution: Verified a new through hull fitting was provided.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 November 2022
Resolved
A periodic examination…shall include the…rudder…and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Stbd rudder hull penetration is deteriorated. Remove rudder for closer inspection of penetration by CG marine inspector. Provide repair proposal.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 12 April 2023
Resolution: verified the installation of a new rudder port for the STBD rudder.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 November 2022
No resolution recorded
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Both engines had soft plastic orange fencing material installed to prevent contact with rotating machinery. Install permanent suitable covers to protect against contact on both engines.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 November 2022
Resolved
A periodic examination…shall include the underwater hull and appendages…and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Fiberglass along keel is damaged/deteriorated in multiple locations. Provide repair proposal.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2023
Resolution: Updated deficiency to reflect new hull damage
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2022
Resolved
A periodic examination…shall include the…rudder…and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Port rudder has pitting corrosion. Provide repair proposal or replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2023
Resolution: Verified weld reapair to the port rudder. Pitted areas were gouged and welded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2022
Resolved
A periodic examination…shall include the…rudder…and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Stbd Rudder has pitting corrosion, an approximate 6" crack, and is bent. Provide repair proposal or replace.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 12 April 2023
Resolution: Verified weld repairs to the stbd rudder. Pitted areas and the fracture were gouged and welded and the rudder stock was trued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2022
Resolved
A periodic examination…shall include the…propellers…and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Stbd propeller damaged with bends and chips in the blades and is loose fitting on the key way. Provide repair proposal or replace.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 12 April 2023
Resolution: STBD propeller was sent out for reconditioning. Verified installation of a fully reconditioned propeller.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 October 2022
Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. MIs found the steering gear mounted to a wooden board. The board had multiple severe cracks in it. Ensure the steering gear is mounted to a secure foundation and demonstrate proper operation to the satisfaction of the attending MI.
46 CFR 182.610(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2022
Resolution: Deficiency re-issued as code 17C in Act#7597007
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 October 2022
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. The bilge high level alarm in the lazarette was found lying on the bottom of the bilge. There was also standing water in the space and no alarm on the bridge. Demonstrate proper operation of bilge alarm in the lazarette.
46 CFR 182.530(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2022
Resolution: Deficiency re-issued as code 17C in Act#7597007
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 October 2022
Resolved
Each pipe that penetrates the hull below the waterline must have a means to prevent water from entering the vessel. The owner stated that the heat exchanger on the generator had failed. MIs observed a stream of water coming from the generator and filling the bilge. Ensure proper repairs are made to the generator to prevent water ingress to the lazarette.
46 CFR 179.350(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2022
Resolution: Deficiency re-issued as code 17C in Act#7597007
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 24 October 2022
Resolved
Exhaust gas must not leak from the piping or any connections. MIs observed exhaust smoke in the engine room space. Ensure proper repairs are made to prevent exhaust leaks.
46 CFR 182.430(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2022
Resolution: Deficiency re-issued as code 17C in Act#7597007
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 August 2022
Resolved
Bends in PVC pipe were joined together with electrical tape for head sink drains. Secure all joints on PVC pipe with proper fittings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2022
Resolved 12 September 2022
Resolution: O/O made satisfactory repairs of pvc pipe for deck drains using PVC glue.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 29 August 2022
Resolved
Both engines had orange fencing material installed to prevent contact with rotating machinery. Install permanent suitable covers to protect against contact on both engines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2022
Resolved 18 November 2022
Resolution: Deficiency re-issued as code 17C in Act#7597007
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2022
Resolved
VESSEL HAS 13 OUTSTANDING DEFICIENCIES, 8 OF WHICH ARE PRIOR TO CARRIAGE OF PASSENGERS. VESSEL OPERATOR HAS NOT MADE VESSEL AVAILABLE TO CLEAR OUTSTANDING DEFICIENCIES AND CONTINUES TO OPERATE. VESSEL MAY NOT DEPART PORT UNTIL "PRIOR TO CARRIAGE OF PASSENGERS" DEFICIENCIES HAS BEEN CLEARED BY THE ATTENDING MARINE INSPECTOR.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2022
Resolution: Cleared "prior to carry pax" deficiencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2022
Resolved
Hydraulic ram ball joint attachemet to drag link loose leading to excessive rudder slop. Tighten ram ball joint connection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2022
Resolved 17 June 2022
Resolution: Steering inspected SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 March 2022
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel’s drydock exam deadline is 31MAR22, but is not scheduled for drydock until 08APR22. Vessel must complete satisfactory hull exam/internal structural exam prior to carriage of passengers.
46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2022
Resolution: Vessel received credit DDX/ISE.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 16 March 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems. No deckhands were available at time of inspection and no drills were conducted to determine operational readiness of vessel or crew. Conduct satisfactory man overboard, abandon ship, and firefighting drills in presence of marine inspector prior to carriage of passengers.
46 CFR 176.808(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2022
Resolution: Completed satisfactory MOB, abandon ship and FF drills.
10 - Safety of Navigation › N/A - No Subsystem › GNSS receiver/terrestrial radio navigation system
Issued 16 March 2022
Resolved
A vessel on an oceans route must be equipped with an electronic position fixing device. Vessel's GPS was inoperable. Restore GPS capability.
46 CFR 184.410
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2022
Resolution: O/O provided new GPS unit.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 March 2022
Resolved
A vessel must carry adequate and up-to-date…Charts of large enough scale to make safe navigation possible. Vessel had no electronic charting system or corrected paper charts on board. Obtain approved electronic charting system suitable for oceans route or appropriate paper charts for route and areas of operation.
46 CFR 184.420(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2022
Resolution: Charts provided electronically, in two means.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 16 March 2022
Resolved
Shutoff valves…shall be fitted in the fuel supply lines…The shutoff valve at the tank shall be operable from outside the tank compartment. The port F/O tank remote shutoff failed on attempted operation. Restore port F/O tank remote shutoff functionality.
46 CFR 182.20-40(b)(3) ("Old T")
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2022
Resolution: Witness satisfactory test of both port and starboard fuel shut off valves.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 16 March 2022
Resolved
Provision must be made for closing all supply duct cowls or scoops…for a space protected by a fixed gas extinguishing system. Starboard side engine room air supply vent has no provision for securing damper to vent. Provide means of securing damper to vent.
46 CFR 182.465(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2022
Resolution: Provided means of securing vents on both port and starboard side.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 March 2022
Resolved
Gages to indicate…lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. Port engine electronic oil gauge showed 0 psi and alarmed “CODE 36: OIL PRESSURE SENSOR LOW.” Repair port engine L/O gauge or sensor.
46 CFR 182.20-5(b) (“Old T”)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 17 June 2022
Resolution: Repaired using mechanic. Loose wire deemed the issue.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 March 2022
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Both engines had only orange plastic temporary fencing installed to prevent human contact with rotating machinery. Install permanent suitable guards or covers capable of preventing human contact with rotating machinery.
46 CFR 177.35-15(a) (“Old T”)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 29 August 2022
Resolution: Re-issued by Sector Juneau.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 16 March 2022
Resolved
At each inspection for certification…toilet and washing spaces…may be examined to determine that they are serviceable and in a sanitary condition. Starboard head sink pipe was disconnected, causing sink to drain directly into bilge. Bends in PVC pipe were joined with electrical tape. Secure all joints on PVC pipe line with proper fittings or restrict use of head sink.
46 CFR 176.818
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 29 August 2022
Resolution: Re-issued by Sector Juneau.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 March 2022
Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected IAW standards acceptable to the cognizant OCMI as good marine practice. Potable water pump is designed to be securely mounted, but is unsecured and hanging freely by suction and discharge hoses in engine room space. Securely mount potable water pump.
46 CFR 176.800(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 17 June 2022
Resolution: Potable water pump mounted.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 16 March 2022
Resolved
A [marine sanitation] device must…be designed to prevent the overboard discharge of treated or untreated sewage. No valve exists between overboard discharge pump on type III MSD and overboard discharge through-hull fitting. Install valve between discharge pump and through-hull fitting.
46 CFR 184.704; 33 CFR 159.53(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 17 June 2022
Resolution: Through hull fitting installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2022
Resolved
Circuit breakers of the proper voltage rating shall be of the manually reset type…capable of repeatedly opening the circuit in which it is to be used without damage to the circuit breaker. AC Main, Reverse Polarity, and Outlets switches on 120 volt distribution panel at operating station are broken and incapable of manual reset. Replace broken switches.
46 CFR 183.10-35(e) (“Old T”)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 8 April 2022
Resolution: Breakers replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 March 2022
Resolved
A submersible electric bilge pump may be used…provided that…a positive shutoff valve is installed at the hull penetration. Ball valve of bilge line underneath main cabin was installed several feet inboard of hull penetration. Install positive shutoff valve at the through-hull penetration.
46 CFR 182.520(e)(7)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 8 April 2022
Resolution: Valve moved to through hull fitting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2022
Resolved
The enclosures and frames of electrical equipment must be bonded together to a common ground by a normally non-current carrying conductor. Starboard engine grounding wire was nearly detached from common ground, and port engine grounding wire was completely detached from common ground. Securely connect both engines to common ground.
46 CFR 183.372(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 17 June 2022
Resolution: Achieved common ground.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 May 2021
Resolved
Both main engines were missing guards to protect against rotating machinery. Install guards in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Owner installed required machinery guards.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 May 2021
Resolved
Both main engines have oil leaks at the turbo charger. Repair oil leaks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Owner repaired oil leak at the lube oil supply fitting for both the port and starboard main diesel engines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 May 2021
Resolved
Bilge alarm visual indicator on the bridge is not functioning. Repair visual indicator on the bridge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Owner repaired the indicator light at the operating station for the bilge alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2021
Resolved
Properly label fuel oil shutoff valves to include direction of closure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Owner restenciled the emergency fuel shut off valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2021
Resolved
Double clamp generator exhaust hose coupling as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Owner installed double hose clamps on all generator exhaust hose connections.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 May 2021
Resolved
Repair/replace broken receptacle cover in the fwd storage area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Owner replaced the broken receptacle cover in the fwd storage with a new one.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 May 2021
Resolved
Provide one additional portable light as required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2021
Resolved 7 June 2021
Resolution: Owner replaced the missing portable flashlight with a new one.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 18 March 2020
Resolved
Repair inoperable SSB radio (Icom IC-M700) or replace with MF-DSC frequency transmitter. Vessel’s route on COI is restricted to Coastwise, not more than 20 nautical miles offshore until MF radio operation is demonstrated on distress frequencies: 4125, 6215, 8291 or 12290 kHz voice. 46 CFR 184.502 / 47 CFR 80.905(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2020
Resolved 24 May 2021
Resolution: Amended route on COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2020
Resolved
Secure sea strainers for main engines; hanging by flexible hoses only. 46 CFR 182.100
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 18 April 2020
Resolved 15 April 2020
Resolution: Sea strainers refastened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2020
Resolved
Adjust hose clamps on flexible hose to water pump on port MDE. 46 CFR 182.20-40
Action required: 10 - Deficiency Rectified
Due 18 April 2020
Resolved 15 April 2020
Resolution: New hose clamps installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 March 2020
Resolved
Mark vessel name on ring buoy where lettering is coming off. 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 April 2020
Resolved 15 April 2020
Resolution: Lettering on ring buoy corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 March 2020
Resolved
Repair leak on flexible hose for crankcase exhaust on port engine that is venting into space. 46 CFR 182.100
Action required: 10 - Deficiency Rectified
Due 18 April 2020
Resolved 15 April 2020
Resolution: Flexible hose connected properly.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 March 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Due 18 April 2020
Resolved 15 April 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 March 2019
Resolved
Prove proper operation of Fireboy engine shutdown, manual override, and engine restart after simulated discharge. 46 CFR 181.420(b)(3)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2019
Resolution: New alarm panel and bridge circuit panel installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 March 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 April 2019
Resolution: Original on board.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 March 2018
Resolved
KK01- Provide proof of operation of audible and visual indicators for all three bilge alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2019
Communications › Radio Communications › EPIRB
Issued 14 March 2018
Resolved
Install new hydrostatic release unit for EPIRB.
Action required: 705 - Other - as specified
Resolved 17 April 2019
Resolution: Expiry: 03-2020
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 March 2018
Resolved
KK03- Replace one childsize lifejacket.
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 17 April 2019
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 14 March 2018
Resolved
KK04- Label both emergency fuel shut-offs and repair port bowl.
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 17 April 2019
Construction/Loadline › Hull › Side Shell
Issued 1 July 2016
Resolved
Submit repair proposal to the local OCMI for pre-approval to make permanent repairs to all areas of the hull and internal structure damaged by hitting iceberg on 29 June 2016.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2016
Resolution: Repair proposal has been received and repairs have been completed to the satisfaction of the attending marine inspector, Sector Puget Sound. Reference MISLE Activity #6018509 for details.
Communications › Radio Communications › EPIRB
Issued 14 June 2016
Resolved
Properly mark vessel name on the EPIRB.
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 16 June 2016
Resolution: Owner marked vsl's name onto the EPIRB with permanent marker.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 11 May 2009
Resolved
14 Adult PFDs and 1 Child PFD found to be non-compliant. Require replacement of 12 Adult PFDs in order for vessel to operate at full capacity as allowed by COI.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 May 2009
Resolution: Master purchased 16 new PFDs. Verified CG approval and vessel name stenciled on each PFD.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 May 2007
Resolved
Replace expired aspirin in med kit.
Due 14 May 2007
Resolved 14 May 2007
Resolution: New aspirin provided.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Determination of Alcohol/Drug Use
Issued 1 May 2007
Resolved
Provide DOT-approved alcohol test kits.
Due 14 May 2007
Resolved 14 May 2007
Resolution: Test kits provided.
Electrical › Electric Generation Source (service)
Issued 10 March 2004
Resolved
Complete inspection and testing of the newly installed genset. Genset is not to be operated while passengers are on board until inspection is completed by the attending marine inspector. LEGACY COMPONENT DESC: Generator
Due 30 April 2004
Resolved 13 April 2004
Lifesaving › Lifejacket/PFD (General)
Issued 10 March 2004
Resolved
Renew one adult size life jacket that was rejected due to rotten straps. Reduce total persons on board to 49 until renewed. LEGACY COMPONENT DESC: Condition
Due 30 April 2004
Resolved 13 April 2004
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 10 March 2004
Resolved
Renew broken window on starboard side of cabin.
Due 30 April 2004
Resolved 13 April 2004
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 3 April 2003
Resolved
Repair and demonstrate operation of engine shut-down for fixed firefighting system. This item must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Due 18 April 2003
Resolved 18 April 2003
Resolution: [name withheld] from MSO Puget Sound visited the vessel at Port Angeles, WA to clear the deficiencies.
Lifesaving › Inflatable Liferafts
Issued 3 April 2003
Resolved
Provide weak link for HAMMAR hydrostatic release for inflatable buoyant apparatus. This item must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Weak Link
Condition: Improper Installation
Due 18 April 2003
Resolved 9 April 2003
Lifesaving › Lifebuoys
Issued 3 April 2003
Resolved
Renew battery for ring buoy waterlight. This item must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Due 18 April 2003
Resolved 9 April 2003
Fire Fighting › Miscellaneous Items
Issued 3 April 2003
Resolved
Provide lines and label fire buckets. This item must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Buckets
Condition: Improper Installation
Due 18 April 2003
Resolved 9 April 2003
Communications › Radio Communications
Issued 3 April 2003
Resolved
Provide FCC Station license. LEGACY COMPONENT DESC: Station license
Condition: Unknown
Due 31 May 2003
Resolved 12 May 2003
Stability › Intact Righting Energy
Issued 3 April 2003
Resolved
Complete stability test and obtain new stability letter. This item is to be completed prior to starting the 2004 operating season, but in no case later than the compliance date. LEGACY COMPONENT DESC: Simplified Test
Due 1 May 2004
Resolved 3 March 2004
Resolution: Satisfactory simplified stability test witnessed at Westport, WA by [name withheld] and [name withheld] from MSO Portland. New letter to be issued by MSO Portland.
Stability › Incline Test
Issued 20 June 2002
Resolved
Conduct a simplified stability proof test to prove that the vessel possesses sufficient intact stability for the carriage of 51 persons on exposed waters per Title 46, Code of Federal Regulations, Part 178, Subpart C.
Action required: 705 - Other - as specified
Due 15 April 2003
Resolved 27 June 2002
Resolution: Requirement rescended. OCMI review of the vessel''s simplified stability proof test concluded that a new stability test is not required.
Stability › Weathertight Integrity
Issued 13 June 2002
Resolved
Make the door on the aft deck weathertight in accordance with 46CFR171.124(d) LEGACY COMPONENT DESC: Door
Due 30 May 2003
Resolved 3 April 2003
Lifesaving › Inflatable Liferafts
Issued 13 June 2002
Resolved
Prior to April 15, 2003, the vessel must be fitted with inflatable buoyant apparatus with a capacity for 100% of the persons carried aboard in accordance with US Coast Guard Seventeenth District policy.
Due 15 April 2003
Resolved 3 April 2003
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 April 2002
Resolved
Provide 4" maximum spacing of rail courses or equivalent per excursion vessel standards of 46 CFR 177.900(g). The vessel may be authorized to conduct excursions trips during the 2002 season only if an equivalency is granted by the cognizant OCMI per CGD17(moc) ltr 16711 of 11 Apr 2002. LEGACY COMPONENT DESC: Deck Rail
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2003
Resolved 30 April 2006
Resolution: Owner put up plastic mesh and zip tied it to his rails. This was granted as an equivalency by [name withheld] as long as it is maintained when ever the vessel is engaged in passenger excursions.
Construction/Loadline › Structures
Issued 28 March 2002
Resolved
Make the diamond plate on the main deck water tight. LEGACY COMPONENT DESC: Deck Plating
Condition: Unknown
Due 28 April 2002
Resolved 11 April 2002
Construction/Loadline › Structures
Issued 28 March 2002
Resolved
Tighten hand rails around entire vessel. LEGACY COMPONENT DESC: Hand Rails
Condition: Improper/Lack of Maintenance
Due 28 April 2002
Resolved 11 April 2002
Construction/Loadline › Hull
Issued 28 March 2002
Resolved
Make repairs to gel coat on portside of vessel near transom LEGACY COMPONENT DESC: Gel Coat
Condition: Unknown
Due 28 April 2002
Resolved 11 April 2002
Stability › Watertight Integrity
Issued 28 March 2002
Resolved
Make repairs to the collision bulkhead (split on portside) LEGACY COMPONENT DESC: Collision Bulkhead
Condition: Unknown
Due 28 April 2002
Resolved 11 April 2002
Construction/Loadline › Penetrations
Issued 28 March 2002
Resolved
Remove hose from through hose fitting and have it capped. LEGACY COMPONENT DESC: Through hole fittings
Condition: Improper Installation
Due 28 April 2002
Resolved 11 April 2002
Construction/Loadline › Penetrations
Issued 28 March 2002
Resolved
Make bulkheads watertight. LEGACY COMPONENT DESC: Bulkhead penetrations
Condition: Placed in Improper Service
Due 28 April 2002
Resolved 11 April 2002
Documentation › Safety/Response Plans/Programs
Issued 28 March 2002
Resolved
Provide waste management plan. LEGACY COMPONENT DESC: Waste Management Plan
Condition: Unknown
Due 28 April 2002
Resolved 11 April 2002
Documentation › Markings/Placards
Issued 28 March 2002
Resolved
Provide Marpol placard. LEGACY COMPONENT DESC: Marpol
Condition: Unknown
Due 28 April 2002
Resolved 11 April 2002
Personnel › Training
Issued 28 March 2002
Resolved
Provide valid drug testing program. LEGACY COMPONENT DESC: Drug testing program
Condition: Unknown
Due 28 April 2002
Resolved 11 April 2002
Communications › Radio Communications
Issued 28 March 2002
Resolved
Provide FCC operator license. LEGACY COMPONENT DESC: FCC license
Condition: Unknown
Due 28 April 2002
Resolved 11 April 2002
Lifesaving › Buoyant Apparatus
Issued 28 March 2002
Resolved
Provide retro tape for ring buoy. LEGACY COMPONENT DESC: Ring Buoy
Condition: Unknown
Due 28 April 2002
Resolved 11 April 2002
Navigation › Piloting/Steering
Issued 28 March 2002
Resolved
Provide Rules of the Road book. LEGACY COMPONENT DESC: Inland Navigation Rules
Condition: Unknown
Due 28 April 2002
Resolved 11 April 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 28 March 2002
Resolved
Renew expired items in the first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Placed in Improper Service
Due 28 April 2002
Resolved 11 April 2002
Construction/Loadline
Issued 23 May 2001
Resolved
SEAL OR MODIFY PIPING PENETRATIONS IN STERN TO RESTORE WATERTIGHT INTEGRITYOF HULL.
Condition: Unknown
Due 23 June 2001
Resolved 4 June 2001
Engineering
Issued 23 May 2001
Resolved
PROPERLY GROUND F/O FILL HOSES AND TANKS.
Condition: Unknown
Due 23 June 2001
Resolved 4 June 2001
Accommodation/Occupational Safety
Issued 23 May 2001
Resolved
CLOSE SEWAGE OVERBOARD DISCHARGE VALVE WHENEVER WITHIN 3 NM OF SHORE AND PROVIDE POSITIVE LOCKING DEVICE FOR VALVE.
Condition: Unknown
Due 23 June 2001
Resolved 4 June 2001
Electrical
Issued 23 May 2001
Resolved
REPLACE BROKEN ELECTRICAL OUTLET ON BRIDGE.
Condition: Unknown
Due 23 June 2001
Resolved 4 June 2001
Electrical
Issued 23 May 2001
Resolved
REPLACE MISSING LIGHT FIXTURE IN MEN'S HEAD OR REMOVE AND ENCASE EXPOSED WIRES.
Condition: Unknown
Due 23 June 2001
Resolved 4 June 2001
Construction/Loadline
Issued 23 May 2001
Resolved
PROVIDE SUITABLE WEATHER TIGHT DOOR WITH 6" WT COAMING FOR AFT DOOR.
Condition: Unknown
Due 23 June 2001
Resolved 27 June 2002
Resolution: Required 6 inch coaming is installed. Reissued requirement for door only. The compliance date has been extended to May 30, 2003 per D17(m) letter dated July 16, 2002.
Construction/Loadline
Issued 23 May 2001
Resolved
SEAL AND SECURE METAL "DIAMOND PLATE" ACCESS HATCH ABOVE FUEL TANK SPACE TOMAKE WATERTIGHT.
Condition: Unknown
Due 23 June 2001
Resolved 4 June 2001
Navigation
Issued 23 May 2001
Resolved
PROVIDE LIGHT LIST AND TIDAL CURRENT TABLES FOR AREAS OF OPERATION.
Condition: Unknown
Due 30 May 2003
Resolved 3 April 2003
Electrical
Issued 23 May 2001
Resolved
PROVIDE CHAF-PROTECTED METALLIC SUPPORTS AT 24" INTERVALS FOR ALL ELECTRICAL RUNS.
Condition: Unknown
Due 23 June 2001
Resolved 4 June 2001
Electrical
Issued 23 May 2001
Resolved
MOUNT OR PROPERLY SECURE HYDRAULIC FIXTURE W/HOSES ABOVE STBD MAIN BATTERY BANK.
Condition: Unknown
Due 23 June 2001
Resolved 4 June 2001
Electrical
Issued 23 May 2001
Resolved
SECURE LIGHT FIXTURE THAT HANGS BY WIRE (OUTBOARD OF STBD MDE).
Condition: Unknown
Due 23 June 2001
Resolved 4 June 2001
Engineering
Issued 23 May 2001
Resolved
INSTALL SECONDARY HOSE CLAMPS ON P/S SHAFT HOSE SEAL.
Condition: Unknown
Due 23 June 2001
Resolved 4 June 2001
Construction/Loadline
Issued 23 May 2001
Resolved
REMOVE OR CAP UN-USED PIPES AND HOSES THAT PENETRATE WT BULKHEADS/HULL.
Condition: Unknown
Due 23 June 2001
Resolved 4 June 2001
Documentation
Issued 23 May 2001
Resolved
PROVIDE EVIDENCE OF VALID MARINE OPERATORS PERMIT.
Condition: Unknown
Due 23 June 2001
Resolved 4 June 2001
Accommodation/Occupational Safety
Issued 23 May 2001
Resolved
LABEL LOCATION OF FIRST AID KIT.
Condition: Unknown
Due 23 June 2001
Resolved 4 June 2001
Accommodation/Occupational Safety
Issued 23 May 2001
Resolved
PROVIDE ADDITIONAL RAIL COURSES OR EQUIVALENT FOR DECK RAILS.
Condition: Unknown
Due 23 June 2001
Resolved 11 April 2002
Resolution: D17(moc) formally addressed the operator’s appeal of MSO Juneau CG-835 requirement of 27 Aug 01 to provide suitable rails for excursion vessel service per ltr 16711 of 11 Apr 02. Reissued req''t under case 1611724.
Lifesaving
Issued 23 May 2001
Resolved
PROVIDE NOAA REGISTRATION FOR EPIRB.
Condition: Unknown
Due 23 June 2001
Resolved 28 June 2001
Accommodation/Occupational Safety
Issued 23 May 2001
Resolved
REMOVE OR REPLACE ALL COMBUSTABLE WASTE RECEPTACLES WITH APPROVED METAL TYPE.
Condition: Unknown
Due 23 June 2001
Resolved 4 June 2001
Fire Fighting
Issued 5 April 2000
Resolved
Provide proof of servicing of fire extinguishers.
Condition: Unknown
Due 5 April 2000
Resolved 5 April 2000
Lifesaving
Issued 5 April 2000
Resolved
Provide hydrostatic release mechanism for liferaft prior to carrying passengers.
Condition: Unknown
Due 5 April 2000
Resolved 5 April 2000
Documentation
Issued 5 April 2000
Resolved
Provide proof of valid vessel documentation.
Condition: Unknown
Due 5 April 2000
Resolved 5 April 2000
Fire Fighting
Issued 12 April 1999
Resolved
COMPLETE INSTALLATION OF FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 17 April 1999
Resolved 4 May 1999
Engineering
Issued 12 April 1999
Resolved
REPLACE COOLING WATER INJECTION HOSES ON PORT SIDE ENGINE.
Condition: Unknown
Due 17 April 1999
Resolved 4 May 1999
Documentation
Issued 12 April 1999
Resolved
PROVIDE VALID SHIP STATION LICENSE.
Condition: Unknown
Due 17 April 1999
Resolved 4 May 1999
Lifesaving
Issued 12 April 1999
Resolved
PROVIDE LIFE JACKET DONNING PLACARD.
Condition: Unknown
Due 17 April 1999
Resolved 4 May 1999
Documentation
Issued 12 April 1999
Resolved
MAKE DRUG TESTING PROGRAM INFORMATION AVAILABLE.
Condition: Unknown
Due 17 April 1999
Resolved 4 May 1999
Fire Fighting
Issued 29 March 1999
Resolved
SUBMIT PLANS FOR APPROVAL OF FIXED FIREFIGHTING SYSTEM. UPON APPROVAL OF_x001C_ PLANS, COMPLETE INSTALLATION OF SYSTEM AND MAKE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Engineering
Issued 19 March 1998
Resolved
MAKE THE VESSEL AVAILABLE FOR AN OPERATIONAL TEST OF THE PROPULSION,_x001C_ STEERING, AND BILGE SYSTEM.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Navigation
Issued 19 March 1998
Resolved
PROVIDE CURRENT NAVIGATIONAL PUBLICATIONS.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Lifesaving
Issued 25 April 1996
Resolved
Conduct man overboard drills in presence of marine inspector.
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Lifesaving
Issued 25 April 1996
Resolved
Apply retroreflective tape to ringbuoy.
Condition: Unknown
Due 5 May 1996
Resolved 14 May 1996
Lifesaving
Issued 3 April 1995
Resolved
PROVIDE PROOF OF NEW BATTERY FOR EPIRB PRIOR TO OPERATING VESSEL BEYOND 20 MILES.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Documentation
Issued 11 March 1993
Resolved
PROVIDE DOCUMENTATION OF DRUG TESTING PROGRAM FOR CREW MEMBERS.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Construction/Loadline
Issued 27 February 1992
Resolved
MAKE PERMANENT REPAIR TO HOUSE DECK AND BULKHEAD STRENGTH MEMBER ON STBD SIDE FWD OF AND UNDER LADIES HEAD. SHALL BE LIMITED TO COASTWISE UNTIL_x001C_ COMPLETED.
Condition: Unknown
Due 27 February 1992
Resolved 27 February 1992
Construction/Loadline
Issued 27 February 1992
Resolved
ATTACH LATCHING BOLT FOR ENGINE ROOM HATCH WITH RETAINING WIRE.
Condition: Unknown
Due 27 February 1992
Resolved 27 February 1992
Lifesaving
Issued 27 February 1992
Resolved
ATTACH RINGBUOY LIGHT TO RINGBUOY ON SEPARATE LINE <12 FT LONG).
Condition: Unknown
Due 27 February 1992
Resolved 27 February 1992
Fire Fighting
Issued 27 February 1992
Resolved
HYDRO SERVICE TWO B-II FIRE EXTINGUISHERS DATED 1986.
Condition: Unknown
Due 27 February 1992
Resolved 27 February 1992
Engineering
Issued 27 February 1992
Resolved
VERIFY SATISFACTORY OPERATION OF PROPULSION MACHINERY, GENERATOR AND BILGE PUMPS AT SEA TRIALS.
Condition: Unknown
Due 27 February 1992
Resolved 27 February 1992
Construction/Loadline
Issued 27 February 1992
Resolved
PROVIDE EMERGENCY COVERS FOR LOUVRE VENTS TO ENGINE.
Condition: Unknown
Due 27 February 1992
Resolved 27 February 1992
Lifesaving
Issued 27 February 1992
Resolved
PURCHASE APPROVED EPIRB OR VERIFY SATISFACTORY COMPLIANCE WITH FCC FOR_x001C_ 121 MHZ EPIRB. LIMITED TO COASTWISE ROUTE UNTIL COMPLETE.
Condition: Unknown
Due 27 February 1992
Resolved 27 February 1992
Construction/Loadline
Issued 13 February 1990
Resolved
RESEAL ALUMINUM MAIN DECK INSERT AND PROVE WATERTIGHT INTEGRITY IN PRESENCE OF CG INSPECTOR.
Condition: Unknown
Due 13 February 1990
Resolved 13 February 1990
Engineering
Issued 13 February 1990
Resolved
SUBMIT REQUIRED PLANS OF GENERATOR INSTALLATION TO USCG FOR APPROVAL.
Condition: Unknown
Due 13 February 1990
Resolved 13 February 1990
Engineering
Issued 13 February 1990
Resolved
REPLACE GENERATOR SET FUEL HOSES WITH APPROVED TYPE.
Condition: Unknown
Due 13 February 1990
Resolved 13 February 1990
Construction/Loadline
Issued 22 January 1990
Resolved
PROVE WATERTIGHT INTEGRITY OF ALUMINUM DECK INSERT ON MAIN DECK AND ENGINE ROOM HATCH COVER.
Condition: Unknown
Due 22 January 1990
Resolved 22 January 1990
Construction/Loadline
Issued 22 January 1990
Resolved
SUBMIT WEIGHT CALCULATIONS OF ALUMINUM DECK INSERT, TO INCLUDE WEIGHT OF DECK AREA REMOVED.
Condition: Unknown
Due 22 January 1990
Resolved 22 January 1990
Construction/Loadline
Issued 22 January 1990
Resolved
RE-ATTACH LAZARETTE COVER LANYARD.
Condition: Unknown
Due 22 January 1990
Resolved 22 January 1990
Engineering
Issued 22 January 1990
Resolved
PROVIDE REACH ROD FOR PORT FUEL SHUT OFF.
Condition: Unknown
Due 22 January 1990
Resolved 22 January 1990
Engineering
Issued 22 January 1990
Resolved
PROVIDE PLANS FOR GENERATOR INSTALLED IN ENGINE ROOM. INCLUDE ELECTRICAL DIAGRAM, COOLING WATER, EXHAUST INSTALLATION, AND FUEL SUPPLY.
Condition: Unknown
Due 22 January 1990
Resolved 22 January 1990
Engineering
Issued 22 January 1990
Resolved
PROVIDE DOUBLE CLAMPS ON FUEL FILL HOSES.
Condition: Unknown
Due 22 January 1990
Resolved 22 January 1990
Electrical
Issued 22 January 1990
Resolved
PROPERLY CONNECT LOOSE WIRES IN FOREPEAK COMPARTMENT.
Condition: Unknown
Due 22 January 1990
Resolved 22 January 1990
Engineering
Issued 22 January 1990
Resolved
PROPERLY LABEL FUEL SHUT OFFS ON MAIN DECK. INCLUDE DIRECTIONAL ARROWS.
Condition: Unknown
Due 22 January 1990
Resolved 22 January 1990
Lifesaving
Issued 25 April 1989
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE RENEW ALL RED AND ORANGE FLARES.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Lifesaving
Issued 25 April 1989
Resolved
VESSEL RESTRICTED TO COASTWISE ROUTE UNTIL LIGHTS ARE PROVIDED FOR ALL PFD'S THAT ARE OPERABLE.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Lifesaving
Issued 25 April 1989
Resolved
RENEW CRACKED PADDLE FOR LIFE FLOAT.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Lifesaving
Issued 6 April 1987
Resolved
PROVIDE ADDITIONAL CHILDREN'S PFD (FOR A TOTAL OF FOUR) PRIOR TO CARRYING MORE THAN THREE CHILDREN.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987