MAURY USCG vessel records
← All vessels

ADVENTURE BOUND

Built
1978
Last inspected
21 February 2024
Documentation
Expired · NVDC file of 10 August 2026
Controls
2 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 February 2024
…with no type recorded4
Operational controls 2 with no removal date recorded
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCY9685
236350
Flag
UNITED STATES
Maury page id
psix-236350

Documentation record

Registered dimensions (L × B × D)51.5 ft × 16.3 ft × 6.1 ft
Registered tonnagegross 42 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWALTER F BLANCHARD · WESTPORT, WA, UNITED STATES · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portJUNEAU, AK
Endorsements, as the file codes themcw_un, fi, rec, reg
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it42 - Regulatory (Subpart C or D), Gross Ton
33 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 27 inspections, each with its date, unit and type; 76 deficiencies with the resolution recorded against each, 23 without one; 2 operational controls with no removal date recorded; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPTAIN COOK Passenger (Inspected) · MISLE 49107 · 11 April 2022 · activity 7748795CAPTAIN COOK Passenger (Inspected) · MISLE 49107 · 29 June 2016 · activity 5930727

Inspection history · 27

21 February 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7869028
23 May 2023 COI Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7695245
13 May 2023 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7687188
10 April 2023 Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7656543
18 November 2022 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7597007
24 October 2022 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7583194
18 October 2022 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7623273
12 September 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7559208
29 August 2022 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7546665
17 June 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7479840
11 April 2022 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7748795
8 April 2022 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7427527
16 March 2022 COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7412502
24 May 2021 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7205937
13 January 2021 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7124106
18 March 2020 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6928137
9 March 2020 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6923879
20 March 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6655076
18 April 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6393691
14 March 2018 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6310983
15 March 2017 COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6103931
7 October 2016 Permit to Proceed · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6018509
1 July 2016 Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5926027
29 June 2016 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5930727
14 June 2016 In-Service Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5907704
14 April 2016 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5858902
17 March 2016 Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5835180

Deficiency record · 76

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2023 No resolution recorded
The fixed power bilge pump shall be self-priming and may be driven off the main engine. Identified Port engine driven bilge pump not operational. Prove proper operation of port engine driven bilge pump to attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2023 No resolution recorded
Fuel shutoff valves, installed as to close against the fuel flow shall be fitted in the fuel supply lines, one at the tank connection and one at the engine end. The shutoff valve at the tank shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck. Identified port and stbd fuel shutoff valve ram rod was installed using plastic zip ties and a metal bowl. Prove permanent methods to hold position of fuel shutoff reach rods access from weather deck.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2023 No resolution recorded
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Identified a hydraulic line to the steering wheel inside the cabinet behind the helm at operating station, was leaking onto electrical wires. Repair hydraulic leak and remove residual hydraulic fluid from electrical wires inside cabinet.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 May 2023 No resolution recorded
A suitable hull strainer must be installed in the circulating raw water intake line of an engine cooling system. The lazarette generator’s strainer element is deteriorated and requires replacement.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2023 No resolution recorded
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation. The port engine raw water intake flexible hose between suction and strainer is cracked, split and needs replacement.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 23 May 2023 No resolution recorded
All vessels except non-self propelled vessels shall be provided with suitable steering apparatus. Identified STBD steering gear mounted to board with inadequate hardware. Requires installation of proper length hardware and nuts.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2023 No resolution recorded
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Identified engine room bilge audible alarm was not functioning properly and was emitting erratic alarms at the operating station. Repair erratic alarm and prove proper operation to marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 23 May 2023 No resolution recorded
Except for engine exhausts, each inlet or discharge pipe that penetrates the hull 6 inches above the deepest waterline must have means to prevent water from entering the vessel if the pipe fractures or fails. Identified plastic cap on a thru hull fitting IVO Port side amidships. Replace plastic cap on pipe penetration with suitable metallic cap. 46CFR171.119(b)
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 May 2023 No resolution recorded
Each lifejacket carried on a vessel on oceans, coastwise route must have a life jacket light IAW 161.012. Light must be securely attached to front shoulder area of life jacket. Identified 15 lifejackets with inoperable lights and attached in wrong location. Prove proper operation of all life jacket lights.
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 May 2023 No resolution recorded
Each ring life buoy must be marked in clearly legible block capital letters with the vessel’s name. Identified ring life buoy was not satisfactorily marked, retroreflective tape was found unsatisfactory and tear in seam. Replace with new life ring.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2023 No resolution recorded
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Identified ECM was unsatisfactorily zip tied to STBD Engine. Permanently affix ECM to STBD Engine. 46CFR183.01-15
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 May 2023 No resolution recorded
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Identified dead end wires behind steering console and in vicinity of VHF radio at the helm. 46CFR183.01-15
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2023 No resolution recorded
Protect crew, or other persons and the vessel from electrical hazards, including fire and electrical shock. Install protective covers over positive terminals of the battery installations.
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 May 2023 No resolution recorded
A vessel must carry either a first aid kit approved under 160.041 or a kit with equivalent contents. First aid kit expired, replace expired components
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 23 May 2023 No resolution recorded
The USCG will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners, will be issued for a maximum period of 5 years. Master of vessel is to provide proof of medical certificate to attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 May 2023 No resolution recorded
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board. No alcohol testing strips were on board. Provide sufficient number of alcohol test strips.
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 May 2023 No resolution recorded
Portable extinguishers must be inspected and maintained in accordance with NFPA 10 Annually. Identified portable extinguisher in the forward lower compartment had not received annual servicing. Provide evidence of serviced fire extinguisher as required by COI.
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 May 2023 No resolution recorded
EPIRB must be tested monthly. No records or logs of testing were available for EPIRB. Create new logbook to document monthly testing of EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 May 2023 No resolution recorded
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. No drill logs were available. Create new logbook for completing drills.
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 May 2023 No resolution recorded
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. No drill logs were available. Create new logbook for completing drills.
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 May 2023 No resolution recorded
Portable fire extinguisher monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. No records of inspection were available for vessel to maintain monthly checks. Create new logbook for completing required monthly interval inspection.
Action required: 701 - Prior to carriage of passengers/cargo
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 May 2023 No resolution recorded
As appropriate for the intended voyage, a vessel must carry adequate and up to date publications: U.S. Coast Pilot [name withheld] List and Navigation Rules were not onboard. Provide current publications for vessel’s intended route.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 November 2022 Resolved
All vessels...shall be provided with suitable steering apparatus. MIs found the steering gear mounted to a wooden board. The board had multiple severe cracks in it. Ensure the steering gear is mounted to a secure foundation and demonstrate proper operation to the satisfaction of the attending MI.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 12 April 2023
Resolution: Verified renewal of wood plank steering foundations; however, updated deficiency to reflect the requirement for additional foundation supports.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 November 2022 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. The bilge high level alarm in the lazarette was found lying on the bottom of the bilge. There was also standing water in the space and no alarm on the bridge. Demonstrate proper operation of bilge alarm in the lazarette.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 23 May 2023
Resolution: Lazarette bilge alarm reinstalled, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 November 2022 Resolved
Each…pipe that penetrates the hull below [the waterline] must have means to prevent water from entering the vessel. The owner stated that the heat exchanger on the generator had failed. MIs observed a stream of water coming from the generator and filling the bilge. Ensure proper repairs are made to the generator to prevent water ingress to the lazarette.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 23 May 2023
Resolution: Heat exchanger replaced, ops check good, no water leakage.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 November 2022 Resolved
Exhaust piping…shall be gas-tight throughout its length. MIs observed exhaust smoke in the engine room space. Ensure proper repairs are made to prevent exhaust leaks.
Action required: 30 - Ship detained
Resolved 23 May 2023
Resolution: Exhaust leaks repaired, ops check good.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 18 November 2022 Resolved
A periodic examination…shall include the throughhull fittings…and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Amidship, stbd thru-hull fitting above the waterline is broken and a possible ingress point for water. Replace.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 12 April 2023
Resolution: Verified a new through hull fitting was provided.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 November 2022 Resolved
A periodic examination…shall include the…rudder…and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Stbd rudder hull penetration is deteriorated. Remove rudder for closer inspection of penetration by CG marine inspector. Provide repair proposal.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 12 April 2023
Resolution: verified the installation of a new rudder port for the STBD rudder.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 November 2022 No resolution recorded
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Both engines had soft plastic orange fencing material installed to prevent contact with rotating machinery. Install permanent suitable covers to protect against contact on both engines.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 November 2022 Resolved
A periodic examination…shall include the underwater hull and appendages…and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Fiberglass along keel is damaged/deteriorated in multiple locations. Provide repair proposal.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2023
Resolution: Updated deficiency to reflect new hull damage
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2022 Resolved
A periodic examination…shall include the…rudder…and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Port rudder has pitting corrosion. Provide repair proposal or replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2023
Resolution: Verified weld reapair to the port rudder. Pitted areas were gouged and welded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2022 Resolved
A periodic examination…shall include the…rudder…and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Stbd Rudder has pitting corrosion, an approximate 6" crack, and is bent. Provide repair proposal or replace.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 12 April 2023
Resolution: Verified weld repairs to the stbd rudder. Pitted areas and the fracture were gouged and welded and the rudder stock was trued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2022 Resolved
A periodic examination…shall include the…propellers…and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Stbd propeller damaged with bends and chips in the blades and is loose fitting on the key way. Provide repair proposal or replace.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 12 April 2023
Resolution: STBD propeller was sent out for reconditioning. Verified installation of a fully reconditioned propeller.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 October 2022 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. MIs found the steering gear mounted to a wooden board. The board had multiple severe cracks in it. Ensure the steering gear is mounted to a secure foundation and demonstrate proper operation to the satisfaction of the attending MI. 46 CFR 182.610(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2022
Resolution: Deficiency re-issued as code 17C in Act#7597007
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 October 2022 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. The bilge high level alarm in the lazarette was found lying on the bottom of the bilge. There was also standing water in the space and no alarm on the bridge. Demonstrate proper operation of bilge alarm in the lazarette. 46 CFR 182.530(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2022
Resolution: Deficiency re-issued as code 17C in Act#7597007
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 October 2022 Resolved
Each pipe that penetrates the hull below the waterline must have a means to prevent water from entering the vessel. The owner stated that the heat exchanger on the generator had failed. MIs observed a stream of water coming from the generator and filling the bilge. Ensure proper repairs are made to the generator to prevent water ingress to the lazarette. 46 CFR 179.350(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2022
Resolution: Deficiency re-issued as code 17C in Act#7597007
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 24 October 2022 Resolved
Exhaust gas must not leak from the piping or any connections. MIs observed exhaust smoke in the engine room space. Ensure proper repairs are made to prevent exhaust leaks. 46 CFR 182.430(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2022
Resolution: Deficiency re-issued as code 17C in Act#7597007
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 August 2022 Resolved
Bends in PVC pipe were joined together with electrical tape for head sink drains. Secure all joints on PVC pipe with proper fittings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2022
Resolved 12 September 2022
Resolution: O/O made satisfactory repairs of pvc pipe for deck drains using PVC glue.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 29 August 2022 Resolved
Both engines had orange fencing material installed to prevent contact with rotating machinery. Install permanent suitable covers to protect against contact on both engines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2022
Resolved 18 November 2022
Resolution: Deficiency re-issued as code 17C in Act#7597007
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2022 Resolved
VESSEL HAS 13 OUTSTANDING DEFICIENCIES, 8 OF WHICH ARE PRIOR TO CARRIAGE OF PASSENGERS. VESSEL OPERATOR HAS NOT MADE VESSEL AVAILABLE TO CLEAR OUTSTANDING DEFICIENCIES AND CONTINUES TO OPERATE. VESSEL MAY NOT DEPART PORT UNTIL "PRIOR TO CARRIAGE OF PASSENGERS" DEFICIENCIES HAS BEEN CLEARED BY THE ATTENDING MARINE INSPECTOR.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2022
Resolution: Cleared "prior to carry pax" deficiencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2022 Resolved
Hydraulic ram ball joint attachemet to drag link loose leading to excessive rudder slop. Tighten ram ball joint connection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2022
Resolved 17 June 2022
Resolution: Steering inspected SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 March 2022 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel’s drydock exam deadline is 31MAR22, but is not scheduled for drydock until 08APR22. Vessel must complete satisfactory hull exam/internal structural exam prior to carriage of passengers. 46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2022
Resolution: Vessel received credit DDX/ISE.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 16 March 2022 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems. No deckhands were available at time of inspection and no drills were conducted to determine operational readiness of vessel or crew. Conduct satisfactory man overboard, abandon ship, and firefighting drills in presence of marine inspector prior to carriage of passengers. 46 CFR 176.808(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2022
Resolution: Completed satisfactory MOB, abandon ship and FF drills.
10 - Safety of Navigation › N/A - No Subsystem › GNSS receiver/terrestrial radio navigation system
Issued 16 March 2022 Resolved
A vessel on an oceans route must be equipped with an electronic position fixing device. Vessel's GPS was inoperable. Restore GPS capability. 46 CFR 184.410
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2022
Resolution: O/O provided new GPS unit.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 March 2022 Resolved
A vessel must carry adequate and up-to-date…Charts of large enough scale to make safe navigation possible. Vessel had no electronic charting system or corrected paper charts on board. Obtain approved electronic charting system suitable for oceans route or appropriate paper charts for route and areas of operation. 46 CFR 184.420(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2022
Resolution: Charts provided electronically, in two means.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 16 March 2022 Resolved
Shutoff valves…shall be fitted in the fuel supply lines…The shutoff valve at the tank shall be operable from outside the tank compartment. The port F/O tank remote shutoff failed on attempted operation. Restore port F/O tank remote shutoff functionality. 46 CFR 182.20-40(b)(3) ("Old T")
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2022
Resolution: Witness satisfactory test of both port and starboard fuel shut off valves.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 16 March 2022 Resolved
Provision must be made for closing all supply duct cowls or scoops…for a space protected by a fixed gas extinguishing system. Starboard side engine room air supply vent has no provision for securing damper to vent. Provide means of securing damper to vent. 46 CFR 182.465(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2022
Resolution: Provided means of securing vents on both port and starboard side.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 March 2022 Resolved
Gages to indicate…lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. Port engine electronic oil gauge showed 0 psi and alarmed “CODE 36: OIL PRESSURE SENSOR LOW.” Repair port engine L/O gauge or sensor. 46 CFR 182.20-5(b) (“Old T”)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 17 June 2022
Resolution: Repaired using mechanic. Loose wire deemed the issue.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 March 2022 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Both engines had only orange plastic temporary fencing installed to prevent human contact with rotating machinery. Install permanent suitable guards or covers capable of preventing human contact with rotating machinery. 46 CFR 177.35-15(a) (“Old T”)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 29 August 2022
Resolution: Re-issued by Sector Juneau.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 16 March 2022 Resolved
At each inspection for certification…toilet and washing spaces…may be examined to determine that they are serviceable and in a sanitary condition. Starboard head sink pipe was disconnected, causing sink to drain directly into bilge. Bends in PVC pipe were joined with electrical tape. Secure all joints on PVC pipe line with proper fittings or restrict use of head sink. 46 CFR 176.818
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 29 August 2022
Resolution: Re-issued by Sector Juneau.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 March 2022 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected IAW standards acceptable to the cognizant OCMI as good marine practice. Potable water pump is designed to be securely mounted, but is unsecured and hanging freely by suction and discharge hoses in engine room space. Securely mount potable water pump. 46 CFR 176.800(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 17 June 2022
Resolution: Potable water pump mounted.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 16 March 2022 Resolved
A [marine sanitation] device must…be designed to prevent the overboard discharge of treated or untreated sewage. No valve exists between overboard discharge pump on type III MSD and overboard discharge through-hull fitting. Install valve between discharge pump and through-hull fitting. 46 CFR 184.704; 33 CFR 159.53(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 17 June 2022
Resolution: Through hull fitting installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2022 Resolved
Circuit breakers of the proper voltage rating shall be of the manually reset type…capable of repeatedly opening the circuit in which it is to be used without damage to the circuit breaker. AC Main, Reverse Polarity, and Outlets switches on 120 volt distribution panel at operating station are broken and incapable of manual reset. Replace broken switches. 46 CFR 183.10-35(e) (“Old T”)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 8 April 2022
Resolution: Breakers replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 March 2022 Resolved
A submersible electric bilge pump may be used…provided that…a positive shutoff valve is installed at the hull penetration. Ball valve of bilge line underneath main cabin was installed several feet inboard of hull penetration. Install positive shutoff valve at the through-hull penetration. 46 CFR 182.520(e)(7)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 8 April 2022
Resolution: Valve moved to through hull fitting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2022 Resolved
The enclosures and frames of electrical equipment must be bonded together to a common ground by a normally non-current carrying conductor. Starboard engine grounding wire was nearly detached from common ground, and port engine grounding wire was completely detached from common ground. Securely connect both engines to common ground. 46 CFR 183.372(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 17 June 2022
Resolution: Achieved common ground.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 May 2021 Resolved
Both main engines were missing guards to protect against rotating machinery. Install guards in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Owner installed required machinery guards.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 May 2021 Resolved
Both main engines have oil leaks at the turbo charger. Repair oil leaks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Owner repaired oil leak at the lube oil supply fitting for both the port and starboard main diesel engines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 May 2021 Resolved
Bilge alarm visual indicator on the bridge is not functioning. Repair visual indicator on the bridge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Owner repaired the indicator light at the operating station for the bilge alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2021 Resolved
Properly label fuel oil shutoff valves to include direction of closure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Owner restenciled the emergency fuel shut off valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2021 Resolved
Double clamp generator exhaust hose coupling as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Owner installed double hose clamps on all generator exhaust hose connections.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 May 2021 Resolved
Repair/replace broken receptacle cover in the fwd storage area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Owner replaced the broken receptacle cover in the fwd storage with a new one.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 May 2021 Resolved
Provide one additional portable light as required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2021
Resolved 7 June 2021
Resolution: Owner replaced the missing portable flashlight with a new one.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 18 March 2020 Resolved
Repair inoperable SSB radio (Icom IC-M700) or replace with MF-DSC frequency transmitter. Vessel’s route on COI is restricted to Coastwise, not more than 20 nautical miles offshore until MF radio operation is demonstrated on distress frequencies: 4125, 6215, 8291 or 12290 kHz voice. 46 CFR 184.502 / 47 CFR 80.905(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2020
Resolved 24 May 2021
Resolution: Amended route on COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2020 Resolved
Secure sea strainers for main engines; hanging by flexible hoses only. 46 CFR 182.100
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 18 April 2020
Resolved 15 April 2020
Resolution: Sea strainers refastened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2020 Resolved
Adjust hose clamps on flexible hose to water pump on port MDE. 46 CFR 182.20-40
Action required: 10 - Deficiency Rectified
Due 18 April 2020
Resolved 15 April 2020
Resolution: New hose clamps installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 March 2020 Resolved
Mark vessel name on ring buoy where lettering is coming off. 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 April 2020
Resolved 15 April 2020
Resolution: Lettering on ring buoy corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 March 2020 Resolved
Repair leak on flexible hose for crankcase exhaust on port engine that is venting into space. 46 CFR 182.100
Action required: 10 - Deficiency Rectified
Due 18 April 2020
Resolved 15 April 2020
Resolution: Flexible hose connected properly.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 March 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Due 18 April 2020
Resolved 15 April 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 March 2019 Resolved
Prove proper operation of Fireboy engine shutdown, manual override, and engine restart after simulated discharge. 46 CFR 181.420(b)(3)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2019
Resolution: New alarm panel and bridge circuit panel installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 March 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 April 2019
Resolution: Original on board.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 March 2018 Resolved
KK01- Provide proof of operation of audible and visual indicators for all three bilge alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2019
Communications › Radio Communications › EPIRB
Issued 14 March 2018 Resolved
Install new hydrostatic release unit for EPIRB.
Action required: 705 - Other - as specified
Resolved 17 April 2019
Resolution: Expiry: 03-2020
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 March 2018 Resolved
KK03- Replace one childsize lifejacket.
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 17 April 2019
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 14 March 2018 Resolved
KK04- Label both emergency fuel shut-offs and repair port bowl.
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 17 April 2019
Construction/Loadline › Hull › Side Shell
Issued 1 July 2016 Resolved
Submit repair proposal to the local OCMI for pre-approval to make permanent repairs to all areas of the hull and internal structure damaged by hitting iceberg on 29 June 2016.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2016
Resolution: Repair proposal has been received and repairs have been completed to the satisfaction of the attending marine inspector, Sector Puget Sound. Reference MISLE Activity #6018509 for details.
Communications › Radio Communications › EPIRB
Issued 14 June 2016 Resolved
Properly mark vessel name on the EPIRB.
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 16 June 2016
Resolution: Owner marked vsl's name onto the EPIRB with permanent marker.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.