MAURY USCG vessel records Sign in
← All vessels

MOLDA

MOLDA is a 1994 tank ship. The Coast Guard has recorded 43 inspections since 1994, most recently in January 2009, along with 12 deficiencies and 10 operational controls.

Records from 1994 to 2009. Most recent: inspection, 20 January 2009.

Built
1994
Last inspected
20 January 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9039597 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
403814
Flag
NORWAY
—
Maury page id
psix-403814

Inspections, by type

…with no type recorded31
Years with a record 15 calendar years (1994–2009)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it30093 - Convention (Subpart B), Net Ton
52157 - Convention (Subpart B), Gross Ton
96347 - Dead Weight, Ton
112046 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ANGELINA AUTUMN Towing Vessel · MISLE 213884 · 9 June 2005 · activity 2407582

Inspection history · 43

20 January 2009 MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3395350
17 December 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3381511
16 December 2008 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3380644
7 September 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3354262
25 June 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3247778
24 January 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3135493
16 December 2007 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3113427
16 May 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2929154
30 March 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2898366
12 October 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2799487
10 July 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2708044
28 April 2006 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2636140
20 March 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2606108
16 March 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2603748
7 March 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2598285
3 March 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2595762
27 February 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2593052
6 December 2005 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2547223
7 August 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2458214
9 June 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2407582
27 January 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2284639
7 December 2004 ISPS II Exam · COC-TVE Renew
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2254955
10 March 2003 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1754966
18 September 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 293691
6 October 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 282875
26 August 2000 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 281496
24 June 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 475521
6 October 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 433314
6 October 1999 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1198193
30 November 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 422809
21 August 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 406939
21 August 1997 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1120266
7 December 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 398135
9 August 1996 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 447161
14 March 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 388974
18 November 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 384835
12 July 1995 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 703059
11 July 1995 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 380123
8 May 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 468209
16 November 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1356903
31 October 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 371870
14 June 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 368073
14 June 1994 Tank Vessel Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401887

Deficiency record · 12

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 December 2008 Resolved
The vessel's OWS system is not functioning properly.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: The unapproved installed permanent pneumatic pump in line with vessel''s fixed bilge pump was removed. after completion of restoring to orig piping arrangement the oily bilge system was operation/function tested with satisfactory results.
Engineering › Bilge Water Management System › Piping
Issued 16 December 2008 Resolved
The vessel installed a permanent pneumatic pump in line with the vessel's fixed bilge pump. The crew was unable to demonstrate proper operation of the fixed bilge pump. Additionally the pneumatic pump and associated piping are not shown on the approved ships piping diagram. The crew shall remove the piping configuration or have it approved by certificate issuing authority.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: Piping restored and blanked off as verified by Cert Issuing Authority.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 December 2008 Resolved
The vessel's Oil content meter is not of the approved type shown on the IOPP nor is the required type required by MARPOL. The vessel shall have the approved type OCM installed and reflected on the IOPP prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: Installed new OCM to comply with MEPC 107(49).
Documentation › Logs/Records › Oil Record Book
Issued 16 December 2008 Resolved
Oil Record Book is inaccurate. Entrees are missing and entered incorrectly.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 January 2009
Resolved 18 December 2008
Resolution: ORB ammended with correct dates and proper entries. Verified by Certificate Issuing Authority.
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 16 December 2008 Resolved
The vessel's crew is unable to provide suitable means for the Zero and Span calibration of the fixed oxygen meter. The vessel must procure span gas, and demonstrate proper calibration and operation of the oxygen meter to the satisfaction of the certificate issuing authority.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: New span gas bottle supplied on board to comply with requirements.
Documentation › Certificates/Documents › IOPP Certificate
Issued 16 December 2008 Resolved
Vessel is transferring sludge through a piping modification into the bilge water holding tank. The piping is not reflected on any piping diagrams and the bilge water holding tank is not authorized for storage of sludge according to the vessel's IOPP. The vessel shall remove piping or have current piping documented on the piping diagrams and the sludge system approved by certificate issuing auth.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: Diagrams now reflect changes and approved by Certificate Issuing Authority.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 16 December 2008 Resolved
The vessel's piping for the sludge system has been modified from the original Administration approved system and piping diagram. The vessel shall return system to original configuration or have current piping documented on piping diagram and oil reside system approved by certificate issuing authority.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: Diagram matches configuration and verified by Cert Issuing Authority.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Liner
Issued 24 January 2008 Resolved
This office received report of vessels number 2 and 6 fracture cylinder liners. Request to conduct repairs at Big Stone has been granted by this office. The vessel needs to submit classification report prior to movement from Big Stone anchorage.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 January 2008
Resolved 27 January 2008
Resolution: Recieved class report on proper repairs of cylinder liners.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 December 2005 Resolved
OWS-OCM not functioning. Not electricity is powering the unit. Unit circuit board is not functioning, ship has already placed an order for a new circuit board. Repair/Replace to satisfaction of IOPP issuing authority.
Action required: 705 - Other - as specified
Due 20 December 2005
Resolved 14 December 2005
Resolution: Received report from class attesting to the proper operation of the vessels OCM, electrical power was restored.
Lifesaving
Issued 6 October 1999 Resolved
VESSEL STARBOARD LIFEBOAT FAIL TO LAUCH DURING LIFEBOAT DRILL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 August 2000
Resolved 26 August 2000
Navigation
Issued 11 July 1995 Resolved
MANUVERING INFORMATION FACT SHEET IS MISSING THE WARNING STATEMENT AS REQUIRED BY TITLE 33 C.F.R. 164.35(g)(7).
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Deck/Cargo
Issued 11 July 1995 Resolved
MAKE PREMANENT REPAIRS TO THE VESSEL'S OIL DISCHARGE MONITORING EQUIPMENT (ODME) PRIOR TO DISCHARGING OVERBOARD ANY CARGO TANK RESIDUES. PROVIDE DOCUMENTATION FROM VESSEL'S FLAG ADMINISTRATION OR D.N.V. STATING THAT THE ODME IS FUNCTIONING PROPERLY PRIOR TO RETURNING TO U.S. WATERS._x001C_
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.