Records from 1994 to 2009. Most recent: inspection, 20 January 2009.
Inspection history · 43
20 January 2009
MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3395350
17 December 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3381511
16 December 2008
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3380644
7 September 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3354262
25 June 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3247778
24 January 2008
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3135493
16 December 2007
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3113427
16 May 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2929154
30 March 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2898366
12 October 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2799487
10 July 2006
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2708044
28 April 2006
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2636140
20 March 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2606108
16 March 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2603748
7 March 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2598285
3 March 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2595762
27 February 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2593052
6 December 2005
ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2547223
7 August 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2458214
9 June 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2407582
27 January 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2284639
7 December 2004
ISPS II Exam · COC-TVE Renew
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2254955
10 March 2003
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1754966
18 September 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 293691
6 October 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 282875
26 August 2000
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 281496
24 June 2000
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 475521
6 October 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 433314
6 October 1999
Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1198193
30 November 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 422809
21 August 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 406939
21 August 1997
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1120266
7 December 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 398135
9 August 1996
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 447161
14 March 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 388974
18 November 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 384835
12 July 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 703059
11 July 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 380123
8 May 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 468209
16 November 1994
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1356903
31 October 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 371870
14 June 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 368073
14 June 1994
Tank Vessel Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401887
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 December 2008
Resolved
The vessel's OWS system is not functioning properly.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: The unapproved installed permanent pneumatic pump in line with vessel''s fixed bilge pump was removed. after completion of restoring to orig piping arrangement the oily bilge system was operation/function tested with satisfactory results.
Engineering › Bilge Water Management System › Piping
Issued 16 December 2008
Resolved
The vessel installed a permanent pneumatic pump in line with the vessel's fixed bilge pump. The crew was unable to demonstrate proper operation of the fixed bilge pump. Additionally the pneumatic pump and associated piping are not shown on the approved ships piping diagram. The crew shall remove the piping configuration or have it approved by certificate issuing authority.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: Piping restored and blanked off as verified by Cert Issuing Authority.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 December 2008
Resolved
The vessel's Oil content meter is not of the approved type shown on the IOPP nor is the required type required by MARPOL. The vessel shall have the approved type OCM installed and reflected on the IOPP prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: Installed new OCM to comply with MEPC 107(49).
Documentation › Logs/Records › Oil Record Book
Issued 16 December 2008
Resolved
Oil Record Book is inaccurate. Entrees are missing and entered incorrectly.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 January 2009
Resolved 18 December 2008
Resolution: ORB ammended with correct dates and proper entries. Verified by Certificate Issuing Authority.
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 16 December 2008
Resolved
The vessel's crew is unable to provide suitable means for the Zero and Span calibration of the fixed oxygen meter. The vessel must procure span gas, and demonstrate proper calibration and operation of the oxygen meter to the satisfaction of the certificate issuing authority.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: New span gas bottle supplied on board to comply with requirements.
Documentation › Certificates/Documents › IOPP Certificate
Issued 16 December 2008
Resolved
Vessel is transferring sludge through a piping modification into the bilge water holding tank. The piping is not reflected on any piping diagrams and the bilge water holding tank is not authorized for storage of sludge according to the vessel's IOPP. The vessel shall remove piping or have current piping documented on the piping diagrams and the sludge system approved by certificate issuing auth.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: Diagrams now reflect changes and approved by Certificate Issuing Authority.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 16 December 2008
Resolved
The vessel's piping for the sludge system has been modified from the original Administration approved system and piping diagram. The vessel shall return system to original configuration or have current piping documented on piping diagram and oil reside system approved by certificate issuing authority.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Resolution: Diagram matches configuration and verified by Cert Issuing Authority.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Liner
Issued 24 January 2008
Resolved
This office received report of vessels number 2 and 6 fracture cylinder liners. Request to conduct repairs at Big Stone has been granted by this office. The vessel needs to submit classification report prior to movement from Big Stone anchorage.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 January 2008
Resolved 27 January 2008
Resolution: Recieved class report on proper repairs of cylinder liners.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 December 2005
Resolved
OWS-OCM not functioning. Not electricity is powering the unit. Unit circuit board is not functioning, ship has already placed an order for a new circuit board. Repair/Replace to satisfaction of IOPP issuing authority.
Action required: 705 - Other - as specified
Due 20 December 2005
Resolved 14 December 2005
Resolution: Received report from class attesting to the proper operation of the vessels OCM, electrical power was restored.
Lifesaving
Issued 6 October 1999
Resolved
VESSEL STARBOARD LIFEBOAT FAIL TO LAUCH DURING LIFEBOAT DRILL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 August 2000
Resolved 26 August 2000
Navigation
Issued 11 July 1995
Resolved
MANUVERING INFORMATION FACT SHEET IS MISSING THE WARNING STATEMENT AS REQUIRED BY TITLE 33 C.F.R. 164.35(g)(7).
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Deck/Cargo
Issued 11 July 1995
Resolved
MAKE PREMANENT REPAIRS TO THE VESSEL'S OIL DISCHARGE MONITORING EQUIPMENT (ODME) PRIOR TO DISCHARGING OVERBOARD ANY CARGO TANK RESIDUES. PROVIDE DOCUMENTATION FROM VESSEL'S FLAG ADMINISTRATION OR D.N.V. STATING THAT THE ODME IS FUNCTIONING PROPERLY PRIOR TO RETURNING TO U.S. WATERS._x001C_
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995