Records from 1984 to 1995. Most recent: inspection, 26 December 1995.
Inspection history · 36
26 December 1995
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 873387
17 January 1995
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 20001
14 December 1994
Deficiency Check · Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 837410
2 November 1993
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1146942
17 March 1993
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1143694
28 October 1992
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1270032
11 May 1992
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 958790
7 November 1991
COI Inspection · Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 937793
18 April 1991
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 513788
17 December 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901660
1 December 1990
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1216541
10 October 1990
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 508914
13 September 1990
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1230278
17 February 1990
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 518933
29 November 1989
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 925213
10 August 1989
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 450145
19 December 1988
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 898607
4 October 1988
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 535664
4 October 1988
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1195329
4 January 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 466884
11 December 1987
Re-Inspection · Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1314236
30 September 1987
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1319121
24 August 1987
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1338798
17 July 1987
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1326491
30 January 1987
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 468523
18 November 1986
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 508908
9 October 1986
Credit Drydock · COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1009247
1 August 1986
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1307401
5 November 1985
COI Inspection · Credit Drydock
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1297234
28 April 1985
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 534900
15 April 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 510643
29 March 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1287865
20 November 1984
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 479620
20 November 1984
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1284499
14 September 1984
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 539397
11 June 1984
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 437683
Construction/Loadline
Issued 14 December 1994
Resolved
Undergo all required hull examinations and make vessel ready for completionof Inspection for Certification prior to being placed back in service. This vessel must be boarded at least once a week to check for damage and/ortank intergrity by the owner's representative.
Condition: Unknown
Due 2 November 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 2 November 1993
Resolved
PRIOR TO LOADING CARGO, PRESENT THE VESSEL FOR A CARGO TANK INTERNAL AND INTERNAL STRUCTURAL EXAM(S).
Condition: Unknown
Due 2 November 1993
Resolved 2 November 1993
Construction/Loadline
Issued 7 November 1991
Resolved
UPON LOADING AND PRIOR TO RELOADING CARGO (ONE WAY TRANSIT SOUTH UNDER LOAD) MAKE THE VESSEL AVAILABLE FOR A CARGO TANK INTERNAL EXAM.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Deck/Cargo
Issued 7 November 1991
Resolved
UPON LOADING AND PRIOR TO RELOADING (ON WAY TRANSIT SOUTH UNDER LOAD) MAKE THE VESSEL AVAILABLE FOR AN INTERNAL STRUCTURAL EXAM.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Construction/Loadline
Issued 1 December 1990
Resolved
DRYDOCK, MAKE AVAILABLE FOR CG INSPECTION: BOW, MAKE PERMENENT REPAIRS TO STBD BOW SLOPE SHEET AND ASSOCIATED DAMAGED AREAS TO SATISFACTION OF ATTENDING CG INSPECTOR.
Condition: Unknown
Due 1 December 1990
Resolved 1 December 1990
Construction/Loadline
Issued 13 September 1990
Resolved
PERMANENTLY REPAIR 12" DECK KNUCKLE FRACTURE ON STBD BOW CORNER.
Condition: Unknown
Due 13 September 1990
Resolved 13 September 1990
Construction/Loadline
Issued 13 September 1990
Resolved
PERMANENTLY REPAIR 6" DECK KNUCKLE FRACTURE ON PORT BOW CORNER.
Condition: Unknown
Due 13 September 1990
Resolved 13 September 1990
Deck/Cargo
Issued 4 October 1988
Resolved
PROVIDE PROOF OF HYDROSTATIC TEST OF CARGO PIPING PRIOR TO NEXT DISCHARGE OF CARGO.
Condition: Unknown
Due 4 October 1988
Resolved 4 October 1988
Deck/Cargo
Issued 30 September 1987
Resolved
DETERMINE SOURCE OF PRODUCT LEAK INTO STEAM HEATING COIL OF THE #1 STBD CARGO TANK AND PERMANENTLY REPAIR SAME PRIOR TO LOADING CARGO IN THE #1 STBD CARGO TANK BUT NOT LATER THAN 31 AUG 87.
Condition: Unknown
Due 30 September 1987
Resolved 30 September 1987
Deck/Cargo
Issued 17 July 1987
Resolved
DETERMINE SOURCE OF PRODUCT LEAK INTO STEAM HEATING COIL OF THE #1 STBD CARGO TANK AND PERMANENTLY REPAIR SAME PRIOR TO LOADING CARGO IN THE #1 STBD CARGO TANK BUT NOT LATER THAN 31 AUG 87.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Construction/Loadline
Issued 9 October 1986
Resolved
ENTIRE SIDE SHELL, GUNWALE, BILGE KNUCKLE, PORT AND STBD RAKE KNUCKLE PLATERENEWED.
Condition: Unknown
Due 9 October 1986
Resolved 9 October 1986
Deck/Cargo
Issued 29 March 1985
Resolved
MAKE PERMANENT REPAIRS TO REMOTE EMERGENCY SHUTDOWN PRIOR TO OPERATION OF DECK MACHINERY BUT NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Deck/Cargo
Issued 20 November 1984
Resolved
MAKE PERMANENT REPAIRS TO EMERGENCY REMOTE SHUTDOWN . REPAIRS TO BE MADE PRIOR TO OPERATION OF DECK MACHINERY.
Condition: Unknown
Due 20 November 1984
Resolved 20 November 1984