AO 35 is a 1942 tank barge. The Coast Guard has recorded 36 inspections since 1984, most recently in December 1995, along with 13 deficiencies.

Records from 1984 to 1995. Most recent: inspection, 26 December 1995.

Built
1942
Last inspected
26 December 1995
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-40558

Inspections, by type

…with no type recorded21
Years with a record 12 calendar years (1984–1995)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Tonnage as PSIX records it654 - Regulatory (Subpart C or D), Gross Ton
654 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 7

Inspection history · 36

26 December 1995 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 873387
17 January 1995 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 20001
14 December 1994 Deficiency Check · Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 837410
2 November 1993 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1146942
17 March 1993 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1143694
28 October 1992 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1270032
11 May 1992 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 958790
7 November 1991 COI Inspection · Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 937793
18 April 1991 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 513788
17 December 1990 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901660
1 December 1990 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1216541
10 October 1990 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 508914
13 September 1990 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1230278
17 February 1990 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 518933
29 November 1989 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 925213
10 August 1989 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 450145
19 December 1988 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 898607
4 October 1988 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 535664
4 October 1988 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1195329
4 January 1988 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 466884
11 December 1987 Re-Inspection · Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1314236
30 September 1987 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1319121
24 August 1987 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1338798
17 July 1987 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1326491
30 January 1987 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 468523
18 November 1986 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 508908
9 October 1986 Credit Drydock · COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1009247
1 August 1986 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1307401
5 November 1985 COI Inspection · Credit Drydock
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1297234
28 April 1985 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 534900
15 April 1985 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 510643
29 March 1985 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1287865
20 November 1984 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 479620
20 November 1984 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1284499
14 September 1984 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 539397
11 June 1984 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 437683

Deficiency record · 13

Construction/Loadline
Issued 14 December 1994 Resolved
Undergo all required hull examinations and make vessel ready for completionof Inspection for Certification prior to being placed back in service. This vessel must be boarded at least once a week to check for damage and/ortank intergrity by the owner's representative.
Condition: Unknown
Due 2 November 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 2 November 1993 Resolved
PRIOR TO LOADING CARGO, PRESENT THE VESSEL FOR A CARGO TANK INTERNAL AND INTERNAL STRUCTURAL EXAM(S).
Condition: Unknown
Due 2 November 1993
Resolved 2 November 1993
Construction/Loadline
Issued 7 November 1991 Resolved
UPON LOADING AND PRIOR TO RELOADING CARGO (ONE WAY TRANSIT SOUTH UNDER LOAD) MAKE THE VESSEL AVAILABLE FOR A CARGO TANK INTERNAL EXAM.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Deck/Cargo
Issued 7 November 1991 Resolved
UPON LOADING AND PRIOR TO RELOADING (ON WAY TRANSIT SOUTH UNDER LOAD) MAKE THE VESSEL AVAILABLE FOR AN INTERNAL STRUCTURAL EXAM.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Construction/Loadline
Issued 1 December 1990 Resolved
DRYDOCK, MAKE AVAILABLE FOR CG INSPECTION: BOW, MAKE PERMENENT REPAIRS TO STBD BOW SLOPE SHEET AND ASSOCIATED DAMAGED AREAS TO SATISFACTION OF ATTENDING CG INSPECTOR.
Condition: Unknown
Due 1 December 1990
Resolved 1 December 1990
Construction/Loadline
Issued 13 September 1990 Resolved
PERMANENTLY REPAIR 12" DECK KNUCKLE FRACTURE ON STBD BOW CORNER.
Condition: Unknown
Due 13 September 1990
Resolved 13 September 1990
Construction/Loadline
Issued 13 September 1990 Resolved
PERMANENTLY REPAIR 6" DECK KNUCKLE FRACTURE ON PORT BOW CORNER.
Condition: Unknown
Due 13 September 1990
Resolved 13 September 1990
Deck/Cargo
Issued 4 October 1988 Resolved
PROVIDE PROOF OF HYDROSTATIC TEST OF CARGO PIPING PRIOR TO NEXT DISCHARGE OF CARGO.
Condition: Unknown
Due 4 October 1988
Resolved 4 October 1988
Deck/Cargo
Issued 30 September 1987 Resolved
DETERMINE SOURCE OF PRODUCT LEAK INTO STEAM HEATING COIL OF THE #1 STBD CARGO TANK AND PERMANENTLY REPAIR SAME PRIOR TO LOADING CARGO IN THE #1 STBD CARGO TANK BUT NOT LATER THAN 31 AUG 87.
Condition: Unknown
Due 30 September 1987
Resolved 30 September 1987
Deck/Cargo
Issued 17 July 1987 Resolved
DETERMINE SOURCE OF PRODUCT LEAK INTO STEAM HEATING COIL OF THE #1 STBD CARGO TANK AND PERMANENTLY REPAIR SAME PRIOR TO LOADING CARGO IN THE #1 STBD CARGO TANK BUT NOT LATER THAN 31 AUG 87.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Construction/Loadline
Issued 9 October 1986 Resolved
ENTIRE SIDE SHELL, GUNWALE, BILGE KNUCKLE, PORT AND STBD RAKE KNUCKLE PLATERENEWED.
Condition: Unknown
Due 9 October 1986
Resolved 9 October 1986
Deck/Cargo
Issued 29 March 1985 Resolved
MAKE PERMANENT REPAIRS TO REMOTE EMERGENCY SHUTDOWN PRIOR TO OPERATION OF DECK MACHINERY BUT NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Deck/Cargo
Issued 20 November 1984 Resolved
MAKE PERMANENT REPAIRS TO EMERGENCY REMOTE SHUTDOWN . REPAIRS TO BE MADE PRIOR TO OPERATION OF DECK MACHINERY.
Condition: Unknown
Due 20 November 1984
Resolved 20 November 1984

Ownership record