Records from 1991 to 2025. Most recent: inspection, 13 November 2025.
Inspection history · 62
13 November 2025
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8269940
12 November 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8033871
17 December 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7839805
16 December 2023
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7839820
14 November 2023
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7824802
17 November 2022
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7596608
18 August 2021
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7290353
27 July 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7269917
22 February 2021
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7181277
12 November 2019
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6903158
20 December 2018
Damage Survey
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6600981
20 December 2018
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6601432
19 November 2018
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6589398
21 September 2018
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6566490
20 September 2018
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6566336
16 August 2018
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6514709
25 February 2018
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6364677
28 January 2018
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6420730
27 December 2017
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6381442
28 May 2017
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6229701
20 April 2017
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6128715
11 January 2017
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6072097
9 October 2015
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5770865
20 June 2015
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5168649
28 April 2015
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5116961
4 February 2015
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5064299
20 November 2014
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5031974
28 March 2014
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4836294
28 March 2014
Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4836334
22 February 2014
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4807139
1 December 2013
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4762096
13 September 2013
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4713889
27 March 2012
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4274662
7 March 2012
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4259325
7 April 2011
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3981838
1 February 2011
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3937359
9 November 2010
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3892327
8 July 2010
Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3796242
4 May 2010
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3733361
29 April 2010
Industry Initiated Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3730078
11 January 2010
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3662189
4 December 2009
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3646674
4 November 2009
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3627996
13 August 2009
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3570643
12 August 2009
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3578243
26 February 2009
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3426313
7 April 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2619340
4 August 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2450904
24 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2318867
18 March 2005
MTSA Verification
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2315276
10 November 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2238471
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1983802
16 February 2003
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1755625
12 February 2003
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1910310
19 November 2002
Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1723351
20 September 2001
Uninspected Towing Vessel
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 772909
24 May 2000
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 278216
23 August 1998
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 419650
2 May 1995
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 378065
17 January 1995
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 20001
2 November 1992
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 129583
12 September 1991
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 667244
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 12 November 2024
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. No covers installed to protect crew from the rotating Port and STBD shafts. Install protections for engine room propulsion shafting.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2024
Resolved 2 December 2024
Resolution: Received and reviewed photo documentation of deficiency correction.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 12 November 2024
Resolved
Fire detection control panel; Labels for all switches and indicator lights, identifying their functions. Fire control panel zones are not labeled for the areas they serve. Label fire detection control panel zones.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2024
Resolved 2 December 2024
Resolution: Received and reviewed photo documentation of deficiency correction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 November 2024
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
The front cover of the electrical breaker panel fwd of the STBD generator was loose exposing electrical components. Secure breaker panel front cover/door.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2024
Resolved 2 December 2024
Resolution: Received and reviewed photo documentation of deficiency correction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 November 2023
Resolved
At least one lifebuoy must have a lifeline, secured around the body of the lifebuoy. If more than one lifebuoy is carried, at least one must not have a lifeline attached. Remove lifeline from one lifebuoy.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2023
Resolved 7 December 2023
Resolution: Lifeline removed from lifebuoy.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 November 2023
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. The navigation assessment must incorporate the requirements of pilothouse resource management of § 140.640, assess operational risks, and anticipate and manage workload demands. It must include all items listed in 46 CFR 140.635.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2023
Resolved 7 December 2023
Resolution: Vessel implemented proper navigation assessment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 November 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Loose/ uncapped wires identified outboard the port main diesel engine. Terminate or cap loose wires.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2023
Resolved 7 December 2023
Resolution: Loose wires capped.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 November 2023
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Vessel missing covers on electrical junction boxes port and STBD side upper E/R near hydraulic system and air compressor.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2023
Resolved 7 December 2023
Resolution: Electrical junction boxe cover added to j-box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 November 2023
Resolved
Alarm set points must be tested Twice every 5 years, with no more than 3 years elapsing since last test. Provide report or documentation of alarm set point tests.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2023
Resolved 12 December 2023
Resolution: Received documentation of satisfactory machinery alarm set point testing
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 17 November 2022
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110. Each item of survival equipment with an expiration date must be replaced during the annual inspection if the expiration date has passed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2022
Resolved 16 December 2022
Resolution: replaced the floating waterlights
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 November 2022
Resolved
Each pyrotechnic distress signal carried to meet this section must be stowed in either:
(1) A portable watertight container carried at the operating station. Portable watertight containers for pyrotechnic distress signals must be of a bright color and must be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high with “DISTRESS SIGNALS
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2022
Resolved 16 December 2022
Resolution: provided a container and labled it
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 November 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. There was excessive oil and soot on the exhaust ventilation fans.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2022
Resolved 16 December 2022
Resolution: cleaned of the oil
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 18 August 2021
Resolved
Vessel is applicable to 33CFR156 pollution prevent regulations. Vessel has not completed required declarations of inspections. Complete declaration of inspections at every over the water transfer of fuel or oil based material.
Action required: 703 - Prior to bunkering operations
Due 18 August 2021
Resolved 19 August 2021
Resolution: Company generated and placed onboard applicable DOI's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 August 2021
Resolved
Vessels are to have lifebuoys connected correctly. Affix corrosion resistant clip to the waterlight and secure bag line to the body of the lifebuoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 19 August 2021
Resolution: Company affixed corrosion resistant clips.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 August 2021
Resolved
Vessel is to have visual distress signals and approved container. Vessel did not have approved visual distress signals or container. Place approved visual distress signals and container onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 19 August 2021
Resolution: Company purchased VDS.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 August 2021
Resolved
Vessel to have Health and Safety Plan specific to vessel operations. Have approved Health and Safety Plan onboard and IAW the 46CFR140.505
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 18 August 2021
Resolution: Company generated and placed Health and Safety Plan onboard the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 August 2021
Resolved
Vessel is required to have a Fuel Maintenance Plan IAW manufacter's specifications. Provide Fuel Maintenance plan and place onboard the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 10 September 2021
Resolution: Vessel Captain emailed excerpts from Fuel Maintenance Plan
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 August 2021
Resolved
Vessel has a foam suppression system onboard. Provide documentation of foam suppression system servicing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2021
Resolved 30 August 2021
Resolution: Received Foam Analysis Report.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 July 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2021
Resolved 18 August 2021
Resolution: MSD Quad Cities Issued COI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 December 2018
Resolved
The gasket failed on the port engine's gear box.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 20 January 2019
Resolved 20 December 2018
Resolution: Technician replaced O-ring in lube oil filter for reduction gear.