MAURY USCG vessel records
← All vessels

MISS MAE

Built
1966
Last inspected
7 August 2024
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 7 August 2024
…with no type recorded24
Operational controls None recorded without a removal date
Years with a record 19 calendar years (1994–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK8677
Flag
UNITED STATES
Maury page id
psix-89797

Documentation record

Registered dimensions (L × B × D)49.1 ft × 22.0 ft × 6.9 ft
Registered tonnagegross 66 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT INC · JEFFERSONVILLE, IN, UNITED STATES · built 1966
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portRAYLAND, OH
Endorsements, as the file codes themcw_un
DocumentationValid · issued 16 March 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Regulatory (Subpart C or D), Net Ton
66 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 39 inspections, each with its date, unit and type; 38 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 17 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 17

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

R. H. BEYMER Towing Vessel · MISLE 246439 · 29 January 2015 · activity 5063180DOROTHY L Towing Vessel · MISLE 359953 · 18 May 2011 · activity 4015596ENID DIBERT Towing Vessel · MISLE 442707 · 18 May 2011 · activity 4015596CBC 302 Tank Barge · MISLE 14332 · 4 May 2010 · activity 3733361AO 302 Tank Barge · MISLE 41232 · 4 May 2010 · activity 3733361STACY MCCUNE Towing Vessel · MISLE 85232 · 4 May 2010 · activity 3733361LAURA K Towing Vessel · MISLE 213394 · 4 May 2010 · activity 3733361R. H. BEYMER Towing Vessel · MISLE 246439 · 4 May 2010 · activity 3733361CTC 9609 Freight Barge · MISLE 446666 · 4 May 2010 · activity 3733361CC 97527 Freight Barge · MISLE 458205 · 4 May 2010 · activity 3733361LOUISVILLE Towing Vessel · MISLE 562686 · 4 May 2010 · activity 3733361CINCINNATI Towing Vessel · MISLE 562687 · 4 May 2010 · activity 3733361TEXAS CITY Towing Vessel · MISLE 844157 · 4 May 2010 · activity 3733361CTC 0706 Freight Barge · MISLE 881843 · 4 May 2010 · activity 3733361CTC 0710 Freight Barge · MISLE 881847 · 4 May 2010 · activity 3733361ART 35041B Freight Barge · MISLE 954881 · 4 May 2010 · activity 3733361CBC 342 Tank Barge · MISLE 1019922 · 4 May 2010 · activity 3733361FLOAT 542 Tank Barge · MISLE 50822 · 12 July 1995 · activity 458786

Inspection history · 39

7 August 2024 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7976068
1 November 2023 Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7819236
31 October 2023 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7818187
3 November 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7590747
24 November 2021 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7357219
25 October 2021 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7268050
24 September 2020 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7064249
5 August 2020 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7024843
22 November 2019 In-Service Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6862635
22 April 2019 Initial Certification · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6667431
5 April 2016 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5853092
17 November 2015 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5766773
29 January 2015 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5063180
24 July 2014 Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5005631
12 July 2011 Industry Initiated Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4079093
18 May 2011 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4015596
9 November 2010 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3892369
2 June 2010 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3768197
4 May 2010 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3733361
29 April 2009 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3470488
31 March 2009 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3452495
22 January 2009 Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3398513
22 January 2009 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3401966
8 December 2008 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3376989
19 August 2008 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3304110
8 April 2008 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3180797
1 April 2008 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3176738
13 July 2006 MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2711699
15 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1992924
9 January 2001 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 285935
27 June 1996 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 659188
20 June 1996 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 659189
27 May 1996 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 48393
12 July 1995 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 458786
20 March 1995 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 659190
13 March 1995 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 376267
12 March 1995 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 64076
12 March 1995 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 226491
19 September 1994 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 71468

Deficiency record · 38

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 November 2022 Resolved
A vessel on a rivers route must carry 3 day and 3 night visual distress signals (or 3 approved under approval series 160.021 or 160.121 or 160.036 or 160.136 which are acceptable as both day and night signals). Visual distress signals expired. Supply the vessel with adequate number of valid visual distress signals.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2022
Resolution: Visual distress signals sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 November 2022 Resolved
Each type I lifejacket must have attached a light. 5 type I lifejackets found without operable lights (1 in the pilothouse & 4 in the locker). Attach lifejacket light approved under 161.012 or 161.112 as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2022
Resolution: Life jacket lights attached to life jackets
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 November 2022 Resolved
Starboard navigation light inoperable. Renew/replace with approved navigation light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2022
Resolution: Starboard nav light operable
08 - Alarms › N/A - No Subsystem › General alarm
Issued 3 November 2022 Resolved
In the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light must be installed. Light did not operate. Renew/replace light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2022
Resolution: New bulb installed, general alarm light operable
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 25 October 2021 Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Aft bulkhead of forward void waisted allowing water to enter from ballast tank. Soft patch being used as temp repair. Crop out wasted metal and repair IAW NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 25 October 2021 Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. Multiple deck hatches not marked. Correct as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 October 2021 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Jacket water leaking from starboard engine outboard side. Repair leak as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2021
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 25 October 2021 Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Hole found between main deck forward void (At bow on center line). Crop out wasted metal and repair IAW NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2021 Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. Generator starter wiring not marine rated (Welding cables). Replace cables with required type.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2021
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 25 October 2021 Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. In areas where space limitations make deck rails impractical, such as at narrow catwalks in way of deckhouse sides, hand grabs may be substituted. Stern of vessel is not equipped with rails. Install rails as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 October 2021 Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. Flammable and combustible products being stored in engine room. Store product in cabinet as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 October 2021
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 25 October 2021 Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including but not limited to slips, trips and falls. Starboard void ladder fell in bilge. Replace ladder.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2021 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Deadend wire found in engine room. Remove wire.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2021
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 25 October 2021 Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. (Alarm Setpoints - twice every 5 years) The tests required by this section must be recorded in accordance with part 140 of this subchapter. No documentation of alarm setpoints was provided. Conduct test and provide documentation as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2021
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 25 October 2021 Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. (Pressure vessel reilef valves - twice every 5 years) The tests required by this section must be recorded in accordance with part 140 of this subchapter. No documentation of pressure relief valve testing was provided for one pressure vessel. Conduct test or replace with new and provide documentation as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 October 2021 Resolved
Lifejackets must have the following attachments and fittings: (1) Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket. (2) Each lifejacket must have a whistle firmly secured by a cord to the lifejacket. 3 of 10 life jackets missing light and whistle. Install equipment as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2021
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 October 2021 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure all bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Oil and oil soaked rags found throughout engineroom bilge. Clean bilges and repair oil leaks.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 25 October 2021 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Starboard aft void space hatch seating surface waisted and not capable of properly sealing. Crop out and replace seating surface with new.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 25 October 2021 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Port aft void space hatch cover missing dogging clamp. Repair as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 25 October 2021 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Forward and port/starboard void space hatch covers missing gasket. Install gasket as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2021
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 25 October 2021 Resolved
The owner or managing operator must implement procedures for reporting unsafe conditions and must have records of the activities conducted under this section. New Health and Safety Manual has no procedures for reporting unsafe conditions.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2021
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 25 October 2021 Resolved
The owner or managing operator must implement a health and safety plan. The health and safety plan must document compliance with this part (Subchapter M) and include record keeping procedures. Health and safety plan references requirements found in Subchapter T (Passenger vessels). Update health and safety plan to reflect requirements found in Subchapter M.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 September 2020 Resolved
Fire detection systems including detectors and alarms must be tested. Records must include date when inspection and test were performed, identification of each unit tested, results of the test and name of person conducting test. Records showed none of the required information.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 September 2020
Resolved 24 September 2020
Resolution: Recieved newly designed record sheet
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 2 September 2020 Resolved
Port face wire has numerous broken strands; vessel must repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 September 2020
Resolved 9 September 2020
Resolution: Facing wire replaced with new
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 September 2020 Resolved
A record of type, size and service of each face wire is required to be available to CG MI for review. Vessel does not have any towing gear records.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2020
Resolved 8 September 2020
Resolution: Vessel presented newly designed record sheets
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 July 2019 Resolved
The 160-B Semi Portable fire extinguisher not properly secured to prevent rolling or movement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2019
Resolved 22 August 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 July 2019 Resolved
No proof that the portable fire pump can deliver the minimum 80 gallons per minute flow rate of the mionimum 60 pounds per square inch pressure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2019
Resolved 5 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 July 2019 Resolved
Electrical distribution panel in pilothouse not properly marked with current or voltage ratings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2019
Resolved 29 July 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 July 2019 Resolved
Vessel unable to display appropriate navigation dayshapes as required by the inland navigation rules.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2019
Resolved 17 August 2020
Resolution: D8 Policy Ltr determined vessel not required day shapes
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 25 July 2019 Resolved
Vessel does not have EAP information posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2019
Resolved 29 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 July 2019 Resolved
There is not a 40-B portable fire extinguisher located in the vicinity of the Flammable Storage Cabinet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2019
Resolved 22 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 25 July 2019 Resolved
Vessel does not have appropriate navigation publications on board, light List, LNM's, ACOE NN's, or inland Navigation Rules Amalgamated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2019
Resolved 5 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 July 2019 Resolved
Vessel does have alarms and monitoring for the propulsion engines, generators, and hydraulic steering reservoir.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2019
Resolved 5 September 2019
Unknown
Issued 9 January 2001 Resolved
Guards were not in place over rotating machinery.
Condition: Unknown
Due 23 February 2001
Resolved 22 February 2001
Unknown
Issued 9 January 2001 Resolved
Vessel is missing marpol placards.
Condition: Unknown
Due 23 February 2001
Resolved 22 February 2001
Engineering
Issued 9 January 2001 Resolved
Flamescreens were missing on from the fuel vents.
Condition: Unknown
Due 23 February 2001
Resolved 22 February 2001
Documentation
Issued 13 March 1995 Resolved
NO DISCHARGE OF OIL PROHIBITED PLACARD ONBOARD.
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995
Documentation
Issued 13 March 1995 Resolved
NO MARPOL GARBAGE DISCHARGE PLACARD ONBOARD.
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995

Ownership record