MAURY USCG vessel records Sign in
← All vessels

TRAVELER

TRAVELER is a 1994 passenger vessel (inspected). The Coast Guard has recorded 75 inspections since 1994, most recently in June 2026, along with 186 deficiencies, 1 operational control and 3 casualty investigations between 2013 and 2021.

Records from 1994 to 2026. Most recent: inspection, 2 June 2026.

Built
1994
Last inspected
2 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCX4343
405601
Flag
UNITED STATES
367171120
Maury page id
psix-405601

Inspections, by type

…with no type recorded7
Years with a record 28 calendar years (1994–2026)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)49.0 ft × 27.3 ft × 6.7 ft
Registered tonnagegross 24 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJAYNE'S MARITIME INC · ISLE OF PALMS, SC, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portFAJARDO, PR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Gross Ton
24 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCX4343MMSI 367171120 · active · compulsorily equipped · granted 30 March 2017, expires 28 April 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DANCING DOLPHIN Passenger (Inspected) · MISLE 427414 · 11 April 1997 · activity 23554

Inspection history · 75

2 June 2026 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8385391
2 September 2025 Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8225439
20 August 2025 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8209873
16 April 2025 Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8225435
27 March 2025 Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8225430
19 March 2025 Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8225420
3 March 2025 Drydock Exam · Internal Structural Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8067286
3 June 2024 Deficiency Check · Examination of Repairs · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7911474
11 July 2023 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7735908
9 February 2023 Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7634028
15 August 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7533953
25 March 2022 Administrative Inspection · Drydock Exam · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7418746
12 August 2021 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7285023
19 July 2021 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7261853
18 July 2021 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7261802
16 July 2021 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7258252
26 April 2021 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7195231
7 April 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7170286
4 November 2020 Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7089391
22 May 2020 Deficiency Check · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6950962
29 May 2019 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6697110
29 October 2018 Drydock Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6570251
8 May 2018 Annual Inspection · Examination of Repairs · DAPI Audit
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6408871
7 October 2017 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6289017
2 May 2017 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6136684
10 November 2016 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6039181
14 September 2016 Administrative Inspection · Examination of Repairs · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6000367
27 August 2014 Hull Examination · Deficiency Check · Deadweight Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4966699
28 May 2014 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4872297
20 May 2014 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4862994
26 June 2012 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4357346
13 June 2012 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4342561
13 June 2012 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4343096
30 May 2012 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4328193
9 September 2010 Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3847508
11 March 2010 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3696511
11 September 2008 Internal Structural Exam · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3351129
19 August 2008 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3305918
6 September 2006 Deficiency Check · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2773175
5 June 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2671019
22 September 2005 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2496858
20 June 2005 COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2396279
22 November 2004 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2245850
18 December 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1966018
21 November 2003 Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1951923
8 September 2003 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1900030
26 February 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1770390
5 December 2002 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1715523
28 October 2002 Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1696972
20 September 2002 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1681998
2 November 2001 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1450697
30 October 2001 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1076780
6 September 2000 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1417334
12 July 2000 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1439064
14 July 1999 Deficiency Check · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1461188
16 June 1999 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1434886
4 August 1998 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1428995
26 August 1997 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1446530
21 July 1997 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1364263
20 June 1997 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1406136
11 April 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 23554
11 April 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 229094
10 December 1996 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1093145
5 December 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 162276
1 March 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 884670
27 February 1996 Plan Review "T" Boat
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 884462
15 February 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 879435
17 January 1996 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1452102
17 October 1995 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 883860
20 September 1995 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 875518
6 September 1995 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1380290
9 September 1994 Excursion Permit
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 865519
25 July 1994 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1144402
10 July 1994 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 64400
2 July 1994 Hull Examination · Initial Certification · Plan Review "T" Boat
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1174369

Deficiency record · 186

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 June 2026 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. 01 fire bucket was fractured. Replace the fire bucket. 46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2026
Resolved 15 June 2026
Resolution: A new fire bucket was placed for service.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 June 2026 Resolved
Each collision bulkhead must not be fitted with any type of penetration or opening except penetrations may be made if they are located as high and as far inboard as practicable and they have a means to make them watertight. There was water intrusion near the starboard side collision bulkhead. Seal the penetrations. 46 CFR 179.310
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2026
Resolved 15 June 2026
Resolution: Water intrusion was found in the inner chainplate connecting to the cable that holds the bridle. It was sealed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 2 June 2026 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Wood rot near 02 backing plates next to the starboard water slide. Crop and renew the wood. 46 CFR 46 CFR 177.300 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2026
Resolved 15 June 2026
Resolution: Wood rot was repaired.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 2 June 2026 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. 02 areas of wood rot in the port side transom. Crop and renew the wood. 46 CFR 46 CFR 177.300 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2026
Resolved 15 June 2026
Resolution: Repaired
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 August 2025 Resolved
All vessels shall be provided with a suitable steering apparatus. Steering gear for the two outboard engines stopped working upon arrival to the dock. 46 CFR 182.30-1 Code 17C.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 August 2025
Resolution: Steering cable that operates the outboard engines was replaceed, tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 August 2025 Resolved
The bilge pipe in "s" vessels shall be not less than one inch nominal pipe size. The bilge suction shall be fitted with with a suitable strainers having an open area not less than 3 times the area of the bilge pipe. None of the fixed bilge hand pump hose outlets has a strainer installed to prevent debris to clog the pipe. 46 CFR 182.25-5 (b), Code 16C
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 31 August 2025
Resolution: Strainers installed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 August 2025 Resolved
vessel limited coastwise route must carry six hand red flare and six hand orange smoke distress signals. any of the hand orange smoke distress signals may be substituted for A rocket parachute flare, or A hand red flare distress signal. Vessel was missing one orange smoke and one red distress signals. 46 CFR 180.68 Code 16C.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 21 August 2025
Resolution: Missing smoke and light flare placed on board.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 20 August 2025 Resolved
Every vessel shall be fitted with a suitable compass. Compass transparent plastic display is damaged, and all glycerin fluid leaked to empty 46 CFR 184.20-1, code 16C.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 29 August 2025
Resolution: A new compass was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 August 2025 Resolved
Fuel flexible hose may be used provided it is fitted with suitable connection fittings and has high resistance to saltwater, petroleum oils and vibrations. Fuel hoses from the engine to the filters, and from the filters to the portable gas tanks shows signs of UV damage. Replace flexible fuel hoses in both port and starboard engines, and filters. 46 CFR 182.15-40 code 16C.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 26 August 2025
Resolution: Hose was replaced.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 August 2025 Resolved
All vessels shall be provided with a suitable steering apparatus. Steering gear for the two outboard engines stopped working upon arrival to the dock. The port side handheld wood steering tiller is showing signs of wood rot at the base. Replace tiller. 46 CFR 182.30-1, Code 16C.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 31 August 2025
Resolution: New tiller installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 August 2025 Resolved
A vessel at anchor shall exhibit where it can best be seen In the fore part, an all-round white light or one ball. Vessel is missing the ball day shape while at anchor. 33 CFR 83.30 (a). Code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 29 August 2025
Resolution: Ball was placed on board for service.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 August 2025 Resolved
Sternlight means a white light placed as nearly as practicable at the stern showing an unbroken light over an arc of the horizon of 135 degrees and so fixed as to show the light 67.5 degrees from right aft on each side of the vessel. Sternlight was not found in compliance with with angle and was loose. 33 CFR 83.21 (c), Code 16C.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 12 September 2025
Resolution: New sternlight was installed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 20 August 2025 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space. Wood rot found in the compartment between mid ship and portside at the transom, on which a structural backing plate was found rotten, crop and renew. 46 CFR 176.600 (d), Code 16C.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 12 September 2025
Resolution: Wood rot was repaired.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 August 2025 Resolved
The master of the vessel shall ensure that the EPIRB is tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. No evidence was found that EPIRB was being tested and logged. Deficiency corrected on the sport by conducting EPIRB testing and logging it. 46 CFR 185.25-20, Code 10C corrected on the spot.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 20 August 2025
Resolution: Corrected on the Spot, by conducting the EPIRB testing and logging it.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 March 2025 Resolved
Aluminium support stanchion bases for the stern bench both were found corroded, allowing water to enter the under deck into the lazzarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2025
Resolved 28 August 2025
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 June 2024 Resolved
The construction and arrangements of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection considering provisions for a seaworthy hull. Provide a repair proposal with details of how the following areas found with wood will be repaired and addressed: a. Crop a renew two ring frames located in the starboard side hull, close to midship found rotten due to water saturation. b. Area of wood rot was found both port and starboard side hulls by mid-ship below waterline. c. Fracture found in centerline transverse frame, directly below where the mast is located. Once the hull plywood has been sanded, vessel owner shall notify USCG and request an attending USCG Marine Inspector to verify the condition of the wood, prior determine if the vessel shall conduct a credit for dry dock prior scheduled date in YR2025. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2024
Resolved 24 June 2024
Resolution: Vessel completed the repair plan and the dammaged wood was corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2024 Resolved
Before getting underway on a voyage or as soon as practicable thereafter, the master of a vessel shall ensure that suitable public announcements are made informing all passengers of the required safety items as established by Regulation 46 CFR 185.506(a). Vessel has been operating without providing an accurate safety orientation as required. 46 CFR 185.506(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2024
Resolved 17 June 2024
Resolution: Vessel created a training schedule and trained their personnel.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 3 June 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high-water level in each of the following normally unmanned spaces and a visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The port visual alarm indicator was found inoperative. 46 CFR 182.530(a)(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2024
Resolved 17 June 2024
Resolution: Rectified deficiency.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 3 June 2024 Resolved
At each inspection for certification and at every other vessel inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine that they are serviceable and in a sanitary condition. Vessel was found with pests, conduct a professional contracted fumigation service and provide a fumigating certificate. 46 CFR 176.818
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2024
Resolved 24 June 2024
Resolution: Vessel contracted professional fumigation services.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 11 July 2023 Resolved
14404 - When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include— (1) Closing each valve leading to an overboard discharge and removing the handle; (2) Padlocking each valve leading to an overboard discharge in the closed position; or (3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position. Marine inspector discovered that vessel is equipped with a type III holding tank with a macerator pump installed on the discharge side. The sewage piping seacock was missing the handle, the master stated that the valve was in the open position and they controlled the discharge of sewage by activating the breaker and manually starting the macerator pump. 33 CFR 159.7 (c) 705 C - prior to using marine head
Action required: 705 - Other - as specified
Resolved 14 July 2023
Resolution: New valve installed and secured.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 11 July 2023 Resolved
14404 - After January 30, 1980, subject to paragraphs (e) and (f) of this section, marine sanitation devices on all vessels on waters that are not subject to a prohibition of the overboard discharge of sewage, treated or untreated, as specified in paragraph (a)(1) of this section, shall be designed and operated to either retain, dispose of, or discharge sewage, and shall be certified by the U.S. Coast Guard. If the device has a discharge, the effluent shall not have a fecal coliform bacterial count of greater than 200 per 100 milliliters, nor suspended solids greater than 150 mg/1. Marine inspector questioned master how they discharge sewage from their type III holding tank, the master stated that he activates the macerator pump and discharges sewage every trip. The vessel's route is confined to 3 NM from Fajardo, an area where untreated sewage discharge is prohibited. 40 CFR 140.3 (d) 705 C
Action required: 705 - Other - as specified
Resolved 14 July 2023
Resolution: vessel drafted and implemented new sewage management procedures.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 19 August 2022 Resolved
Each ship transporting more than six passengers for hire equipped with a radio telephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements; where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. At the time of the inspection the vessel Master did not have a FCC Marine Radio Operator Permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 16 September 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2022 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions were not posted at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2022
Resolved 19 August 2022
Resolution: Images were emailed showing emergency instructions posted at the operating station after MI's had completed the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 19 August 2022 Resolved
Each vessel that operates on the high seas must have on board a FCC Type Accepted Category I, 406MHz EPIRB installed to automatically float free and actuate. The hydrostatic release was both expired and not functional.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2022
Resolved 23 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 August 2022 Resolved
At least one ring life buoy must be fitted with a lifeline. The lifeline attached to the ring life buoy was deteriorated and exhibited broken fibers throughout its entire length.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2022
Resolved 19 August 2022
Resolution: Images were emailed showing a new lifeline was installed and attached to the ring life buoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 August 2022 Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5gal buckets with an attached lanyard and the words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket. Two fire buckets did not have a lanyard, and one fire bucket was not properly stenciled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2022
Resolved 23 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2022 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. The two batteries stored within the operating station had wing nuts on all four battery terminal posts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2022
Resolved 19 August 2022
Resolution: Images were sent showing wing nuts replaced with proper battery terminal nuts.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 August 2022 Resolved
A hatch exposed to the weather must be watertight. Hatches on port and starboard side were not watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2022
Resolved 8 September 2022
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 19 August 2022 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and informatio, specific to the individual vessel. An emergency broadcast placard was not posted at the operating station near the radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2022
Resolved 23 August 2022
Resolution: Image of emergency broadcast posted at operating station was emailed to SSJ.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 March 2022 Resolved
No major repairs or alterations affecting the safety of the vessel with regards to the hull, machinery or equipment, shall be made without the knowledge and approval of the OCMI, Marine Inspection. The portside rudder tube assembly in the lower and outer part of the hull was found to have a hull fracture of about 3" long; and the base of the of the fiberglass rudder tube where bond with the fiberglass bottom plate was found with a fracture that caused water ingress to the portside hull. 1. Submit a repair proposal to conduct permanent repairs for hull fracture and rudder tube base fracture. 2. Conduct all repairs must be conducted as in kind (original) approved plans and repair proposal. 46CFR176.20-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2022 Resolved
No major repairs or alterations affecting the safety of the vessel with regards to the hull, machinery or equipment, shall be made without the knowledge and approval of the OCMI, Marine Inspection. USCG Marine inspector found multiple unapproved welding repairs on existing fractures in several locations of the outboard engines mounting sled, including all structural stringers. 1. Uninstall engine sled to further examination for more stress fractures and damages. 2. Submit a repair proposal to address how these fractures will be corrected. 46CFR176.20-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2022
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 29 March 2022 Resolved
At each initial and subsequent inspection for certification, and reinspection the marine inspector shall examine the main steering apparatus to the extent necessary to determine that its condition is in satisfactory and that its fit for the service intended. 1. Remove and uninstall starboard side rudder post for inspection. 2. Replace all port & stbd cutless bearings; found wasted with excessive play. 46CFR176.25-35
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 March 2022 Resolved
The Marine Inspector shall examine all accessible parts of the vessel's hull, machinery, and equipment to be assured that they are in satisfactory condition. The wooden deck next to the net attachment, portside, was found to have multiple areas of wood rot. Crop and renew all areas found with wood rot. 46CFR176.10-5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2022 Resolved
No major repairs or alterations affecting the safety of the vessel with regards to the hull, machinery or equipment, shall be made without the knowledge and approval of the OCMI, Marine Inspection. Proposed alterations shall be approved by the OCMI, Marine Inspection, before work is started. Drawings will not be required for repairs or replacements in kind (original approved design). The attending USCG Marine Inspector noticed that the forward net attachment was altered from its original design noted in the plan SR 50-9 Rev. B dated 04/20/95. Vessel forward net attachment must be returned to its original construction as designed, or submit the existing net arrangement for approval to the USCG. 46CFR176.10-5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2022
Resolution: Net modification was brought to a higher standard than its original design.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2022 Resolved
The Marine Inspector shall examine all accessible parts of the vessel's hull, machinery, and equipment to be assured that they are in satisfactory condition. The forward netting ropes between port and starboard hull are showing signs of wastage and some are frayed. All forward netting ropes must be replaced by a strong, UV resistant rope 3/8" black poly as DWG# SR 49-5. 46CFR176.10-5.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2022
Resolution: Vessel provided UV resistant specifications on rope.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 29 March 2022 Resolved
The Marine Inspector shall examine all accessible parts of the vessel's hull, machinery, and equipment to be assured that they are in satisfactory condition. The wood and fiberglass structure that holds the forward ladder to embark passengers was found to have wood rot on several pad eyes, where the rope secures it in place. Also, it was noticeable several fractures at different locations. Uninstall and conduct proper repairs (if reparable), otherwise a new structure must be made in kind (original). 46CFR176.10-5.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 August 2021 Resolved
The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Marine inspectors observed multiple sections of the vessel's deck being removed due to wood rot. No repair proposals, plans, or requests were sent to OCMI for approval. Vessel is required to submit plans/scope of work being conducted as well as pictures of wood rot extent and current repair progress. Final repairs must be observed in person and approved by attending marine inspector prior to vessel operating.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 April 2021 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. The starboard side bilge high level alarm was inoperable.
Action required: 10 - Deficiency Rectified
Due 11 May 2021
Resolved 11 May 2021
Resolution: Corrected on the spot.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2021 Resolved
Provide the current main and jib sail square footage dimensions from a 3rd party sail and rigging surveyor in order to compare it current approved Marine Safety Center approved Sail Plan. Last sail and rigging 3rd party survey was missing the current sails dimensions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 16 July 2021
Resolution: Sail dimensions have been provided and found to be in compliance with current MSC Approved Sail Plan.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 April 2021 Resolved
The Rigging Preventive Maintenance Plan (PMP) general description, examination & maintenance schedule, inventory of rigging components must be reviewed and updated. Last version of the PMP found does not have any date and most of the information has changed. Conduct a full review and update of the PMP and submit to USCG Prevention, Inspections Office via email at [email withheld].
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 20 July 2021
Resolution: A new updated Rigging Preventive Maintenance Plan (PMP) has been submitted and reviewed by SSJ Office. PMP has been found in complaince with minimum recommendations in accordance with NVIC 02-16.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 May 2020 Resolved
The OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary. There was no record of the vessel conducting standing rigging maintenance as prescribed in their rigging survey.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2020
Resolved 28 May 2020
Resolution: Vessel will record drills in the future.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 May 2020 Resolved
Each EPIRB must be tested monthly and each test must be logged monthly. The 2020 vessel log did not show evidence of monthly EPIRB tests.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2020
Resolved 28 May 2020
Resolution: Vessel will record drills in the future.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 May 2020 Resolved
The master or managing operator shall instruct each crew member at least once every three months, the duties that the crew member is expected to perform in an emergency. The 2020 vessel log did not show evidence of conducting emergency drills.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2020
Resolved 28 May 2020
Resolution: Vessel will record drills in the future.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 May 2020 Resolved
Each ring life buoy must be marked with Type II retroreflective material. The vessels ring life buoy did not have Type II retroreflective tape.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2020
Resolved 28 May 2020
Resolution: Vessel owner sent picture of ring life bouoy with refelctive tape properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 May 2020 Resolved
A vessel must carry one floating waterlight. The battery within the waterlight had an expiration date of 01/20.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2020
Resolved 28 May 2020
Resolution: Recieved picture of new battery light.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 May 2020 Resolved
The items contained in an approved first-aid kit shall be as listed in Table 160.041-4(b). The vessels first-aid kit did not have all necessary contents.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2020
Resolved 28 May 2020
Resolution: Tourniquet and ammonia inhalants purchased.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 8 May 2018 Resolved
Vessel is required to have valid Radiotelephony certificate on board. Radiotelephony certificate on board was expired. 47CFR80.903 16c
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2018
Resolved 9 May 2018
Resolution: Vessel provided valid radiotelephony certificate.
Electrical › Electric Supply System (service) › Cable
Issued 8 May 2018 Resolved
Twist-on type may not be used for making joints in cables. The pump in the head on the starboard side of the vessel had two twist-on type joints in its wiring. 46CFR183.340.i.2 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 9 May 2018
Resolution: Vessel replaced twist-on type joint on the head on the starboard side of the vessel with approved type.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 7 October 2017 Resolved
Port and STBD void fwd of collision bulkhead are full of water. pump out and make ready for inspection
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2017
Communications › Audible Communications › SPD (Other)
Issued 2 May 2017 Resolved
Provide sound signal meeting Inland Nav Rules or prove conch shell meets requirements.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 2 May 2017
Resolution: Vessel purchased portable sound producing device that meet regulations.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 2 May 2017 Resolved
Provide 3 additional child life-jackets onboard.
Action required: 705 - Other - as specified
Due 2 May 2017
Resolved 2 May 2017
Resolution: 3 additional child life-jackets were provided.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 2 May 2017 Resolved
Stow adult life jackets and child life jackets in distinctly seperate locations.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 2 May 2017
Resolution: The adult and child life-jackets were stowed in distinctly seperate locations.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 2 May 2017 Resolved
Post missing donning placard for life jackets in easily visible location.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 2 May 2017
Resolution: Donning placard posted in easily visble location.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 November 2016 Resolved
Complete an Annual inspection prior to carrying passengers for hire, due to missing an Annual inspection 3 months of either side of COI anniversary date.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 November 2016
Resolution: The vessel completed an Annual inspection.
Engineering › Gas Turbine (propulsion-electric) › Mounting
Issued 14 September 2016 Resolved
Properly secure loose skid mounts and provide repair proposal.
Action required: 705 - Other - as specified
Resolved 30 September 2016
Resolution: Received repair proposal to install beam to connect and reinforce both mounting points to the bridgedeck. Installation and workmanship appeared satisfactory.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 14 September 2016 Resolved
Seal penetration in starboard collision bulkhead.
Action required: 705 - Other - as specified
Resolved 30 September 2016
Resolution: The penetration was properly sealed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 14 September 2016 Resolved
Provide annual service of portable fire extinguishers.
Action required: 705 - Other - as specified
Resolved 1 October 2016
Resolution: Received servicing report.
Lifesaving › Lifebuoys › Serviceable
Issued 14 September 2016 Resolved
Replace deteriorated ring buoy.
Action required: 705 - Other - as specified
Resolved 1 October 2016
Resolution: Received a picture with all the required markings and retro-reflective tape added.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 14 September 2016 Resolved
Install missing gaskets for port and starboard weathertight hatches.
Action required: 705 - Other - as specified
Resolved 30 September 2016
Resolution: New gaskets were installed in both weatherdeck hatches.
Engineering › Steering Gear System › Rudder Bearing
Issued 14 September 2016 Resolved
Replace all four worn rudder bearings and rudder post bolts with worn threads.
Action required: 705 - Other - as specified
Resolved 30 September 2016
Resolution: All bearings and bolts were replaced in kind with new parts.
Sail Rigging › Winches › Mast Mounted
Issued 14 September 2016 Resolved
Provide missing nuts for jib winch.
Action required: 705 - Other - as specified
Resolved 30 September 2016
Resolution: New nuts were installed to hold jib winch to the mast.
Sail Rigging › Deck Hardware › Travellers and Blocks
Issued 14 September 2016 Resolved
Replace worn starboard cleat used for boom pulley.
Action required: 705 - Other - as specified
Resolved 30 September 2016
Resolution: A new cleat was installed where the shackle had worn the cleat close to the securing bolt.
Construction/Loadline › Hull › Keel
Issued 14 September 2016 Resolved
Repair/reglass starboard bow IWO keel.
Action required: 705 - Other - as specified
Resolved 30 September 2016
Resolution: The area of delamination was properly reglassed and available for inspection prior to painting.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 September 2016 Resolved
Remove or properly secure hanging light assembly forward of collision bulkhead in both hulls.
Action required: 705 - Other - as specified
Resolved 30 September 2016
Resolution: The light assemblies were removed, and the former wire penetrations were sealed in both collision bulkheads.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 14 September 2016 Resolved
Replace cracked starboard bilge hatch cover IWO starboard sink.
Action required: 705 - Other - as specified
Resolved 30 September 2016
Resolution: A new bilge hatch cover was installed.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 14 September 2016 Resolved
Install missing power outlet dripshield forward of starboard sink.
Action required: 705 - Other - as specified
Resolved 30 September 2016
Resolution: A dripshield was installed on the outlet.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 14 September 2016 Resolved
Properly install too-large gasket IWO port sink.
Action required: 705 - Other - as specified
Resolved 30 September 2016
Resolution: The gasket was cut and secured to properly conform with the hatch and provide a seal.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 September 2016 Resolved
Secure hanging wire runs in transverse compartment, aft of companionway hatches.
Action required: 705 - Other - as specified
Resolved 30 September 2016
Resolution: The wires were properly secured.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 September 2016 Resolved
Properly terminate red dead-end wire in starboard compartment IWO sink.
Action required: 705 - Other - as specified
Resolved 30 September 2016
Resolution: The wire was removed and the penetrations through the adjacent (non-watertight) bulkhead was sealed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 December 2014 Resolved
Install backing plates for all rail stanchions or otherwise prove compliance with point load/static load strength requirement.
Action required: 705 - Other - as specified
Resolved 17 December 2014
Engineering › Bilge Water Management System › Not Installed
Issued 4 December 2014 Resolved
Replace bilge pumps with UL-listed bilge pumps rated for commercial service.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2014
Documentation › Certificates/Documents › Stability Letter
Issued 4 December 2014 Resolved
Provide valid stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2015
Resolution: MSC issued new stability letter and provided copy to Sector San Juan.
Sail Rigging › Chainplates › Materials
Issued 4 December 2014 Resolved
Provide rigging report including measurements of rigging components where not replaced in kind.
Due 11 December 2014
Resolved 17 December 2014
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 December 2014 Resolved
Prove proper operation of masthead light and steaming light (prior to operating after sunset or in restricted visibility.)
Action required: 705 - Other - as specified
Due 4 December 2014
Resolved 17 December 2014
Sail Rigging › Stays/Shrouds › Clevis Pins and Cotter Pins
Issued 4 December 2014 Resolved
Properly install cotter pin in lower port shroud.
Due 11 December 2014
Resolved 17 December 2014
Resolution: In lower port shroud where cotter pin should be a screw had broken off and remained inside. In lieu of extracting broke piece, a new screw was installed tighly against existing screw and secured with locktight.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 4 December 2014 Resolved
Prove compliance with documentation regulations for name and hailing port.
Due 11 December 2014
Resolved 17 December 2014
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 28 May 2014 Resolved
Post hotline numbers for Drug and Alcohol program
Action required: 705 - Other - as specified
Due 4 June 2014
Resolved 3 June 2014
Resolution: Received documentation of ASSMCA facilities with phone numbers and addresses.
Sail Rigging › Chainplates › Fasteners
Issued 28 May 2014 Resolved
Provide a copy of the vessels sail rigging preventive maintenance program and inventory.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2014
Resolved 3 June 2014
Resolution: Received rigging inspection regime.
Engineering › Fuel Oil Storage/Transfer System › Portable Fuel System
Issued 28 May 2014 Resolved
The design and construction of portable fuel tanks must meet the ABYC H-25 standards. The portable fuel tanks onboard are 12 gallons each.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 June 2014
Resolved 9 June 2014
Resolution: Fuel cans have been replaced in compliance with ABYC H-25 standards (6gal. each).
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 20 May 2014 Resolved
Post emergency instructions/ procedures in a conspicuous space.
Action required: 705 - Other - as specified
Due 27 May 2014
Resolved 28 May 2014
Resolution: Emergency procedures are posted near the operating station.
Sail Rigging › Sails › Correct Sail Area of Record
Issued 20 May 2014 Resolved
Post approved sail plan onboard the vessel in a suitable location IAW the approved stability letter.
Due 27 May 2014
Resolved 28 May 2014
Resolution: Approved Sail Plan dated 10Feb2012 posted onboard.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 20 May 2014 Resolved
Post hotline numbers for Drug and Alcohol program
Action required: 705 - Other - as specified
Due 27 May 2014
Resolved 28 May 2014
Resolution: Reissued to activity 4872297.
Sail Rigging › Chainplates › Fasteners
Issued 20 May 2014 Resolved
Provide a copy of the vessels sail rigging preventive maintenance program and inventory.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2014
Resolved 28 May 2014
Resolution: Reissued to activity 4872297.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 30 May 2012 Resolved
Replace corroded fire extinguisher.
Action required: 705 - Other - as specified
Due 13 June 2012
Resolved 13 June 2012
Resolution: New fire extinguisher was installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 May 2012 Resolved
Provide an approved type first aid kit.
Action required: 705 - Other - as specified
Due 30 May 2012
Resolved 30 May 2012
Resolution: Corrected on the spot, vessel owner/operator provided a new approved first aid kit prior finishing the inspection.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 30 May 2012 Resolved
Provide up to date FCC Radio Safety Certificate.
Action required: 705 - Other - as specified
Due 27 June 2012
Resolved 26 June 2012
Resolution: Copy of the FCC Radio Safety Certificate was provided via e-mail. Document was scanned into MISLE Documents.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 May 2012 Resolved
Properly label bilge alarms to indicate compartments.
Action required: 705 - Other - as specified
Due 13 June 2012
Resolved 13 June 2012
Resolution: Both bilge alarms were labeled.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 30 May 2012 Resolved
Provide an approved alcohol test kit.
Action required: 705 - Other - as specified
Due 13 June 2012
Resolved 30 May 2012
Resolution: Corrected on te spot. Vessel onwer/Operator provided a DOT approved alcohol test kit prior finishing the inspection.
Navigation › Piloting/Steering › Magnetic Compass
Issued 30 May 2012 Resolved
Prove proper operation of compass light. Vessel restricted to daylight operations only.
Action required: 705 - Other - as specified
Due 13 June 2012
Resolved 13 June 2012
Resolution: Compass light was in operation and daylight restriction was eliminated.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 30 May 2012 Resolved
Provide up to date marine chart, coast pilot and light list.
Action required: 705 - Other - as specified
Due 13 June 2012
Resolved 13 June 2012
Resolution: Publications were on board as requested.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 March 2010 Resolved
Vessel must ensure that all deck rails are in compliance with 46 CFR 177.900.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 May 2010
Resolved 24 May 2011
Resolution: Railing is currently 39.5 inches according as required by CFR.
Construction/Loadline › Hull › Hull Plating
Issued 6 September 2006 Resolved
Repair all gelcoat dings and delamination of FRP thru out the hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2006
Engineering › Steering Gear System › Rudder
Issued 6 September 2006 Resolved
Repair port bent rudder.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2006
Fire Fighting › Fire Bucket › Quantity
Issued 5 June 2006 Resolved
Missing two fire buckets, need to be stenciled and have line attached.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 June 2006
Resolved 7 June 2006
Resolution: Two fire buckets were placed on board. Buckets were stenciled and have lines attached.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 5 June 2006 Resolved
Need all publications on board.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 June 2006
Resolved 21 June 2006
Resolution: All publications are on board.
Electrical › Electric Supply System (service) › Cable
Issued 5 June 2006 Resolved
Wires for MSD need to be properly connected
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 June 2006
Resolved 7 June 2006
Resolution: Wires were properly connected.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 September 2005 Resolved
Repair cracked ladder fwd and install stainless safety pins.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2005
Resolution: New safety pins installed and latter renewed.
Engineering › Gasoline Engine (propulsion) › Crankcase (2 stroke)
Issued 22 September 2005 Resolved
Provide operational port outboard motor.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2005
Resolution: Port outboard engine operates properly.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 September 2005 Resolved
Renew or repair fwd bench in front of mast.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2005
Resolution: Fwd bench re-newed.
Construction/Loadline › Hull › Hull Plating
Issued 22 September 2005 Resolved
Repair all small nicks and dents thruout the hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2005
Resolution: Designated areas have been renewed.
Documentation › Certificates/Documents › Stability Letter
Issued 20 June 2005 Resolved
Post Stability Letter
Condition: Improper Installation
Due 20 June 2005
Resolved 20 June 2005
Resolution: Stability Letter posted
Lifesaving › Lifebuoys › Serviceable
Issued 20 June 2005 Resolved
Renew reflective tape on Lifering
Condition: Improper/Lack of Maintenance
Due 20 June 2005
Resolved 20 June 2005
Resolution: New reflective tape has been installed.
Engineering › Gasoline Engine (propulsion) › Ignition Wire (4 cycle)
Issued 20 June 2005 Resolved
Prove proper operation of stbd engine.
Condition: Improper/Lack of Maintenance
Due 20 June 2005
Resolved 20 June 2005
Resolution: Stater selinoid has beed renewed, engine starts and operates.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 20 June 2005 Resolved
Properly provide and install 3 B-II and 1 B-I portable fire ext as per COI.
Condition: Placed in Improper Service
Due 20 June 2005
Resolved 20 June 2005
Resolution: Fire ext installed properly.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 June 2005 Resolved
Ensure wiring throughout vessel meets 46 CFR 111.60, provide marine electrician report attesting to these requirements.
Condition: Placed in Improper Service
Due 20 June 2005
Resolved 20 June 2005
Resolution: Electrician ensured wiring was installed correctly, verified by attending MI.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 20 June 2005 Resolved
Rewire port bilge pump and alarm.
Condition: Improper/Lack of Maintenance
Due 20 June 2005
Resolved 20 June 2005
Resolution: Port bilge pump and alarm has been properly re-wired.
Engineering › Bilge Water Management System › Pump
Issued 20 June 2005 Resolved
Prove proper operation of stbd bilge pump, vsl to not carry passengers until bilge pump operates or provide portable hand pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2005
Resolution: New bilge pump has been installed and operates properly.
Lifesaving › Lifejacket/PFD (Type II) › Retroreflective Material
Issued 20 June 2005 Resolved
Replace reflective tape on 47 lifejackets or reduce passenger count to 13 and 3 crew, (vsl had extra LJ).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2005
Resolution: Vsl installed reflective tape however, reflective material does not meet SOLAS or USCG requirements, another requirement will address this.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 June 2005 Resolved
Provide COD
Condition: Unknown
Due 7 July 2005
Resolved 20 June 2005
Resolution: Verified COD with NVDC.
Communications › Radio Communications › EPIRB
Issued 20 June 2005 Resolved
Install registered EPIRB or lifefloats capable of carrying 26 persons in a float free arrangement.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2005
Resolution: Vessel received and installed registered EPIRB.
Lifesaving › Lifejacket/PFD (Type II) › Retroreflective Material
Issued 20 June 2005 Resolved
Replace unapproved reflective tape with SOLAS or USCG.
Condition: Improper Installation
Due 7 July 2005
Resolved 25 June 2005
Resolution: Vessel installed 3M SOLAS reflective tape #50051131886198.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 22 November 2004 Resolved
RENEW RETROTAPE ON ALL FADED LIFEJACKETS 18 TOTAL.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2004
Communications › Radio Communications › EPIRB
Issued 22 November 2004 Resolved
RENEW EXPIRED EPIRB HYDROSTATIC RELEASE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2004
Lifesaving
Issued 21 November 2003 Resolved
Renew expired epirb registration.
Action required: 705 - Other - as specified
Due 20 December 2003
Resolved 18 December 2003
Lifesaving › Lifejacket/PFD (General)
Issued 21 November 2003 Resolved
Segregate children lifejackets from adults.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 December 2003
Resolved 18 December 2003
Construction/Loadline › Hull › Hull Plating
Issued 8 September 2003 Resolved
Repair all chips & dents in various hull areas.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2003
Construction/Loadline › Hull › Hull Plating
Issued 8 September 2003 Resolved
Plug all old screw holes in stbd aft section.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2003
Engineering › Steering Gear System
Issued 8 September 2003 Resolved
Renew broken steering cable.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2003
Engineering › Steering Gear System
Issued 8 September 2003 Resolved
Repair port rudder fiberglass delamination
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2003
Construction/Loadline › Hull › Longitudinal Frame
Issued 8 September 2003 Resolved
Repair fwd topside hull dry rot area in port hull area by cargo net plate.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2003
Accommodation/Occupational Safety
Issued 8 September 2003 Resolved
Mount waterslide in permanent fashion
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2003
Accommodation/Occupational Safety
Issued 8 September 2003 Resolved
Replace PVC piping supporting fwd embarcation ladder with aluminum or stainless pipe.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2003
Fire Fighting
Issued 28 October 2002 Resolved
Provide one fire bucket and label it with the vessel's name. Prior to Oct 31, 2002. LEGACY COMPONENT DESC: Fire Bucket
Due 31 October 2002
Resolved 5 December 2002
Documentation › Certificates/Documents
Issued 28 October 2002 Resolved
Post the following documents as per 46 VFR Sub T; COI, COD, and Stability Lette. LEGACY COMPONENT DESC: Posting
Due 31 October 2002
Resolved 5 December 2002
Lifesaving › Hand Flares
Issued 28 October 2002 Resolved
Provide two night orange smoke signals (6 required, 4 present). LEGACY COMPONENT DESC: Quantity
Due 31 October 2002
Resolved 5 December 2002
Communications › Radio Communications
Issued 28 October 2002 Resolved
Replace expired EPIRB Battery prior to Oct 23, 2002; evidence of servicing report needs to be provided to clear requirement. LEGACY COMPONENT DESC: EPIRB
Due 5 December 2002
Resolved 5 December 2002
Lifesaving › Lifebuoys
Issued 28 October 2002 Resolved
Attach light to ring buoy, at least one ring buoy must be provided with a light, none of the ring buoys had a light LEGACY COMPONENT DESC: Self-igniting Lights
Due 31 October 2002
Resolved 5 December 2002
Operations/Management › Navigation Safety
Issued 28 October 2002 Resolved
Provide the required sections for the vessel's rout of the following navigational publications required as per 46 CFR Sub T; CG Light List, U.S. Coast Pilot, Tide tables and Tidal Current tables. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Due 31 December 2002
Resolved 26 February 2003
Construction/Loadline › Structures
Issued 20 September 2002 Resolved
The deck area starboard side forward of water slide was found soft. The area is to be reinforced with adequate sub structure prior to carrying passengers and permanent repairs to crop and renewed prior to 1 October 2003. LEGACY COMPONENT DESC: Deck Plating
Due 1 October 2003
Resolved 17 October 2002
Navigation
Issued 2 November 2001 Resolved
Replace Magnetic compass glass no later than 02DEC01.
Condition: Unknown
Due 2 December 2001
Resolved 3 December 2001
Resolution: Faxed statement attesting to repair from [name withheld]
Construction/Loadline
Issued 2 November 2001 Resolved
Repair/replace broken cleat on starboard side of mast.
Condition: Unknown
Due 2 December 2001
Resolved 3 December 2001
Resolution: Faxed statement attesting to repair from [name withheld]
Documentation
Issued 2 November 2001 Resolved
Provide proof that 50% of crew have had first aid/CPR training no later than 02DEC01
Condition: Unknown
Due 2 December 2001
Resolved 3 December 2001
Resolution: Faxed statement attesting to repair from [name withheld]
Fire Fighting
Issued 2 November 2001 Resolved
Replace and install third B-II fire extinguisher. Provide evidence via fax to our office.
Condition: Unknown
Due 2 December 2001
Resolved 3 December 2001
Resolution: Faxed statement attesting to repair from [name withheld].
Navigation
Issued 14 July 1999 Resolved
PROVIDE UPDATED CHARTS FOR OPERATING AREA.
Condition: Unknown
Due 14 August 1999
Resolved 30 August 1999
Documentation
Issued 14 July 1999 Resolved
PROVIDE 50% OF CREW WITH CURRENT CPR CERTIFICATION.
Condition: Unknown
Due 14 August 1999
Resolved 30 August 1999
Documentation
Issued 14 July 1999 Resolved
PROVIDE EVIDENCE IN OFFICIAL LOGBOOK THAT ALL DRILLS ARE BEING CONDUCTED, AND LIFESAVING/FIREFIGHTING EQUIPMENT IS BEING CHECKED.
Condition: Unknown
Due 14 August 1999
Resolved 30 August 1999
Construction/Loadline
Issued 14 July 1999 Resolved
PROVIDE VISUAL INDICATOR FOR AUTOMATIC BILGE PUMP OPERATION.
Condition: Unknown
Due 14 August 1999
Resolved 30 August 1999
Navigation
Issued 14 July 1999 Resolved
PROVIDE APPLICABLE EXCERPTS OF TIDE TABLES, COAST PILOT, AND LIGHT LIST FOROPERATING AREA.
Condition: Unknown
Due 14 August 1999
Resolved 30 August 1999
Lifesaving
Issued 14 July 1999 Resolved
RENEW EPIRB HYDROSTATIC RELEASE MECHANISM.
Condition: Unknown
Due 14 August 1999
Resolved 30 August 1999
Unknown
Issued 14 July 1999 Resolved
PROVIDE DISPLAY FOR EMPLOYEE ASSISTANCE PROGRAM ACCESSIBLE TO ALL CREW.
Condition: Unknown
Due 14 August 1999
Resolved 30 August 1999
Documentation
Issued 14 July 1999 Resolved
POST EMERGENCY OPERATING INSTRUCTIONS
Condition: Unknown
Due 14 August 1999
Resolved 30 August 1999
Construction/Loadline
Issued 14 July 1999 Resolved
DEMONSTRATE PROPER OPERATION OF HIGH BILGE LEVEL ALARMS.
Condition: Unknown
Due 21 July 1999
Resolved 30 August 1999
Documentation
Issued 14 July 1999 Resolved
POST LIFEJACKET DONNING INSTRUCTIONS
Condition: Unknown
Due 14 August 1999
Resolved 30 August 1999
Construction/Loadline
Issued 16 June 1999 Resolved
Schedule an Inspector to attend vessel and evaluate rot in port sided cabinat entrance to port pontoon. Conduct at each inspection and at 6 month intervals until Dry Dock in Fall of 2000. See MINS.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Construction/Loadline
Issued 16 June 1999 Resolved
Provided high bilge level alarm system IAW 46CFR182.530.
Condition: Unknown
Due 16 July 1999
Resolved 30 August 1999
Deck/Cargo
Issued 16 June 1999 Resolved
Provide mast rigging report for main mast prior to operating vessel.
Condition: Unknown
Due 18 June 1999
Resolved 28 June 1999
Documentation
Issued 4 August 1998 Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING FOR CREW (VIA) CONSORTIUM.
Condition: Unknown
Due 8 September 1998
Resolved 12 October 1998
Unknown
Issued 21 July 1997 Resolved
SECURE OR REMOVE FREEZER BOX.
Condition: Unknown
Due 21 August 1997
Resolved 4 September 1997
Fire Fighting
Issued 21 July 1997 Resolved
PROVIDE MAINTENANCE TO FIRE EXIT STARBOARD SIDE.
Condition: Unknown
Due 21 August 1997
Resolved 4 September 1997
Engineering
Issued 21 July 1997 Resolved
SECURE FUEL TANKS BEFORE USING VESSEL WITH PASSENGERS.
Condition: Unknown
Due 21 August 1997
Resolved 24 July 1997
Unknown
Issued 21 July 1997 Resolved
PROVIDE A COAST GUARD APPROVED FIRST AID KIT.
Condition: Unknown
Due 21 August 1997
Resolved 4 September 1997
Electrical
Issued 21 July 1997 Resolved
SECURE ELECTRICAL WIRES TO MSD.
Condition: Unknown
Due 21 August 1997
Resolved 4 September 1997
Accommodation/Occupational Safety
Issued 21 July 1997 Resolved
PROVIDE EVIDENCE THAT MSD IS COAST GUARD APPROVED.
Condition: Unknown
Due 21 August 1997
Resolved 4 September 1997
Lifesaving
Issued 21 July 1997 Resolved
INSTALL DARK COLOR LINE ON LIFEFLOAT'S WATERLIGHTS.
Condition: Unknown
Due 21 August 1997
Resolved 4 September 1997
Construction/Loadline
Issued 21 July 1997 Resolved
DOUBLE CLAMP FLEXIBLE HOSES FOR BILGE PUMP PORT AND STARBOARD PONTOONS.
Condition: Unknown
Due 21 August 1997
Resolved 4 September 1997
Navigation
Issued 21 July 1997 Resolved
REPLACE LIGHT BULB TO MAST NAVIGATION LIGHT.
Condition: Unknown
Due 21 August 1997
Resolved 4 September 1997
Lifesaving
Issued 21 July 1997 Resolved
LABEL CONTAINER FOR FLARES.
Condition: Unknown
Due 21 August 1997
Resolved 4 September 1997
Lifesaving
Issued 21 July 1997 Resolved
MOUNT EPIRB BEFORE USING VESSEL WITH PASSENGERS.
Condition: Unknown
Due 21 July 1997
Resolved 24 July 1997
Construction/Loadline
Issued 21 July 1997 Resolved
INSTALL COTTER PIN ON CHAIN PLATE PORT SIDE AFT.
Condition: Unknown
Due 21 August 1997
Resolved 4 September 1997
Lifesaving
Issued 21 July 1997 Resolved
INSTALL DARK COLOR LINE ON RING BUOY WATERLIGHT.
Condition: Unknown
Due 21 August 1997
Resolved 4 September 1997
Lifesaving
Issued 21 July 1997 Resolved
PROVIDE ONE HAND FLARE.
Condition: Unknown
Due 21 August 1997
Resolved 4 September 1997
Construction/Loadline
Issued 10 December 1996 Resolved
REINSTALL PORT AFT BOOM SHEET BLOCK U-BOLT WITH BACKING PLATE.
Condition: Unknown
Due 13 December 1996
Resolved 12 December 1996
Navigation
Issued 10 December 1996 Resolved
REPAIR BOTH RUDDERS AS ORIGINAL.
Condition: Unknown
Due 11 December 1996
Resolved 12 December 1996
Construction/Loadline
Issued 10 December 1996 Resolved
REPAIR PORT KEEL AS ORIGINAL.
Condition: Unknown
Due 11 December 1996
Resolved 12 December 1996
Construction/Loadline
Issued 10 December 1996 Resolved
REPAIR STBD KEEL AS ORIGINAL AT JULY 1997 DRYDOCK.
Condition: Unknown
Due 21 July 1997
Resolved 21 July 1997
Documentation
Issued 10 December 1996 Resolved
FILE REPORT OF MARINE CASUALTY WITH THE U.S. COAST GUARD.
Condition: Unknown
Due 13 December 1996
Resolved 20 December 1996
Accommodation/Occupational Safety
Issued 15 February 1996 Resolved
PROVIDE PROPOSAL ON HAND RAILING FROM FORWARD COCKPIT TO FORWARD SEATING AREA TO [name withheld], PUERTO RICO.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Navigation
Issued 15 February 1996 Resolved
PROVIDE REPAIR PROPOSAL FOR PORT AND STBD RUDDER POST LEAKS.
Condition: Unknown
Due 15 March 1996
Resolved 19 March 1996
Lifesaving
Issued 17 January 1996 Resolved
PERMANENTLY MARK PASSENGER AREAS FORWARD; AFT OF THE FORWARD SEAT AND AFT OF THE TRAMPOLINE, "NO PASSENGERS". TO BE COMPLETED PRIOR TO THE CARRYING OF PASSENGERS.
Condition: Unknown
Due 17 January 1996
Resolved 17 January 1996
Accommodation/Occupational Safety
Issued 17 January 1996 Resolved
PROVIDE DRAWINGS OF INTERNAL AND EXTERNAL ACCOMODATIONS. TO BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 January 1996
Resolved 17 January 1996
Engineering
Issued 17 January 1996 Resolved
STRAIGHTEN AFT STAY CABLE, AREA OF THE 2 TO 1 CONNECTION, 10 FEET DOWN FROMTHE TOP OF THE MAST. TO BE COMPLETED PRIOR TO CARRYING OF PASSENGERS.
Condition: Unknown
Due 17 January 1996
Resolved 17 January 1996
Accommodation/Occupational Safety
Issued 17 January 1996 Resolved
INSTALL GRAB LINES ON THE LOWER MAINSTAYS, TWO ON EACH SIDE. TO BE COMPLETED PRIOR TO THE CARRYING OF PASSENGERS.
Condition: Unknown
Due 17 January 1996
Resolved 17 January 1996
Documentation
Issued 17 January 1996 Resolved
POST STABILITY LETTER AND COI. TO BE COMPLETED PRIOR TO THE CARRYING OF PASSENGERS.
Condition: Unknown
Due 17 January 1996
Resolved 17 January 1996
Lifesaving
Issued 6 September 1995 Resolved
CONDUCT UNDERWAY DRILLS IN ACCORDANCE WITH 46 CFR 185.25-10. IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 6 September 1995
Resolved 6 September 1995
Fire Fighting
Issued 6 September 1995 Resolved
SERVICE OR RENEW ONE B1 AND THREE B2 FIRE EXTINGUISHERS IN ACCORDANCE WITH 46 CFR 176.25-25. THIS IS TO BE COMPLETED PRIOR TO OPERATION.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Documentation
Issued 6 September 1995 Resolved
SUPPLY APPLICATION FOR FCC SAFETY CERTIFICATE IN ACCORDANCE WITH 46 CFR 176.05-5(C). VESSEL RESTRICTED TO 1000 FEET FROM SHORE UNTIL IN COMPLIANCE.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Documentation
Issued 6 September 1995 Resolved
PROVIDE COMPANY DRUG TESTING POLICY IN ACCORDANCE WITH 46 CFR 16-205.
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Engineering
Issued 6 September 1995 Resolved
RENEW FASTENERS FROM BOOM TO GOOSE NECK IN ACCORDANCE WITH 46 CFR 176.30-1.THIS IS TO BE COMPLETED PRIOR TO OPERATION.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Lifesaving
Issued 6 September 1995 Resolved
POST EMERGENCY CHECK-OFF LIST IN ACCORDANCE WITH 46 CFR 185.25-1. THIS IS TO BE PROVIDED PRIOR TO OPERATION.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Lifesaving
Issued 6 September 1995 Resolved
PROVIDE CHILDRENS LIFE PRESERVERS (6) IN ACCORDANCE WITH 46 CFR 180.25-5. THIS IS TO BE PROVIDED PRIOR TO OPERATION.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Lifesaving
Issued 6 September 1995 Resolved
PROVIDE EMERGENCY CHECK-OFF LIST IN ACCORDANCE WITH 46 CFR 185.25-1. THIS IS TO BE PROVIDED PRIOR TO OPERATION.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Lifesaving
Issued 2 July 1994 Resolved
POST EMERGENCY CHECKOFF PROCEDURES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 July 1994
Resolved 15 August 1995
Lifesaving
Issued 2 July 1994 Resolved
PROVIDE DRY STOWAGE FOR CHILDREN'S PFDS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 July 1994
Resolved 15 August 1995
Construction/Loadline
Issued 2 July 1994 Resolved
PROVIDE STOP VALVES AT ALL THROUGH HULL FITTINGS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 July 1994
Resolved 16 August 1995
Accommodation/Occupational Safety
Issued 2 July 1994 Resolved
NO PASSENGERS SHALL MOVE FORWARD UNTIL SATISFACTORY RAILS, BARRIERS, AND STEPS ARE PROVIDED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 September 1994
Resolved 15 August 1995
Documentation
Issued 2 July 1994 Resolved
PROVIDE OIL POLLUTION AND TRASH PLACARDS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 July 1994
Resolved 15 August 1995

Casualty record · 3

9 November 2013Routine · role: Involved in a Marine Casualty · 1 injured · activity 4750946
18 July 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 7261802
19 July 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7261853
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.