Inspection history · 93
3 September 2008
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3316664
28 December 2007
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3121903
2 November 2007
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3092003
18 January 2007
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2858151
17 January 2007
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2857246
8 January 2007
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2850237
5 December 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2834345
26 June 2006
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2692214
21 June 2006
Deficiency Check · Deadweight Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2687316
25 May 2006
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2658571
25 August 2005
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2475144
5 August 2005
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2452714
19 May 2005
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2362602
15 April 2005
Administrative Inspection
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2334448
24 February 2005
Administrative Inspection
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2298575
11 January 2005
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2274483
20 December 2004
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2262419
17 December 2004
Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2261213
1 December 2004
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2251333
22 July 2004
Deficiency Check · Annual Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2138028
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2006024
24 September 2003
Administrative Inspection
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1912145
26 August 2003
Administrative Inspection
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1887504
5 March 2003
Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1753058
8 January 2002
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1476378
17 January 2001
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1056836
16 October 2000
Examination of Repairs
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1462156
5 May 2000
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1049568
22 March 2000
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 816552
9 February 2000
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1365570
17 May 1999
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 797257
16 April 1999
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1453583
19 February 1999
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1129934
15 April 1998
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 756391
9 April 1998
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 190622
9 April 1998
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 528572
5 March 1998
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1431922
2 March 1998
Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1450089
26 June 1997
Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1113120
15 March 1997
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 487427
31 December 1996
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 760167
30 December 1996
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 190618
21 December 1996
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 470876
22 November 1996
Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1181354
12 September 1996
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 952567
22 August 1996
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1414685
7 April 1996
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 465783
24 March 1996
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 513696
20 September 1995
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1185707
6 March 1995
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 457158
3 January 1995
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 472473
28 December 1994
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 642178
26 December 1994
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 133901
7 October 1994
Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1174578
24 August 1994
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1175718
16 August 1994
Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1177847
4 October 1993
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 828871
3 August 1993
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1152451
30 July 1993
Damage Survey
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 842300
1 December 1992
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 489050
19 November 1992
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1138519
15 October 1992
Hull Examination · COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1266348
9 April 1992
Re-Inspection · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 951520
26 November 1991
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 528680
17 November 1991
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 147650
25 April 1991
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 919651
25 April 1991
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 919816
3 April 1991
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 477654
4 March 1991
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 530416
6 September 1990
Examination of Repairs
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1242516
29 August 1990
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 514079
18 May 1990
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1242615
27 February 1990
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 438872
25 August 1989
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 514781
28 June 1989
Examination of Repairs · Damage Survey
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1207082
9 May 1989
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1044252
19 July 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 484755
29 June 1988
Damage Survey · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1341812
8 April 1988
Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1035471
24 March 1988
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1294371
18 November 1987
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 512154
28 August 1987
Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1309342
28 August 1987
COI Inspection · Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1338849
11 February 1987
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1010793
7 November 1986
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1012422
26 September 1986
Deficiency Check · COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1008276
23 May 1986
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 518115
11 December 1985
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1296997
8 May 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 983257
30 April 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 507673
30 April 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 980356
14 November 1984
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 461349
30 June 1984
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 977315
Electrical › Electric Generation Source (service) › Panelboard
Issued 8 January 2007
Resolved
Renue voltage/amperage selector switch for AC generator. Switch is worn and knob is installed backwards.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 18 January 2007
Resolution: Selector switch installed correctly.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 8 January 2007
Resolved
Renue stick gauge for the number five port cargo tank. Tank is loaded and stick gauge does not indicate loaded condition.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2007
Resolution: Replaced stick gauge. All gauges tested sat.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 8 January 2007
Resolved
Prove proper operation of prime mover jacket water temperature gauge.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 18 January 2007
Resolution: New gauge installed. Witnessed operation.
Pollution Prevention/Response › Prevention Equipment › Designated Observation Area
Issued 8 January 2007
Resolved
Renue warning sign as required by 46CFR35.30-1.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 18 January 2007
Resolution: Warning sign renued.
Deck/Cargo › Cargo Heating › General
Issued 8 January 2007
Resolved
Remove or repair broken temperature gauges on deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 18 January 2007
Resolution: Broken temperature gauges removes and plugged.
Stability › Incline Test › General
Issued 25 May 2006
Resolved
Barge must conduct a deadweight survey as required by MSC letter 17 June 03 and submit the surveys results to Marine Safety Center for review. Prior to conducting cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2006
Resolution: Deadweight survey was conducted on June 26, 2006. The calculations were examined by MSC as per their letter C1-0602579.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 25 May 2006
Resolved
Prove proper operation of ground detection on main panel in accordance with 46 CFR 111.05-21.
Action required: 705 - Other - as specified
Due 25 June 2006
Resolved 21 June 2006
Construction/Loadline › Hull › Hull Plating
Issued 25 May 2006
Resolved
Discovered that company had made repairs to an 8" crack on the stern void, properly test repairs in attendance of USCG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2006
Engineering › Steam System (auxiliary) › Piping
Issued 25 May 2006
Resolved
Provide insulation of forward cross over valve on steam line in accordance with 38.05-20.
Action required: 705 - Other - as specified
Due 25 June 2006
Resolved 21 June 2006
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 25 May 2006
Resolved
Properly provide O-ring for port side cargo tank #5 overfill protection stick gauge in accordance with 33 CFR 155.480.
Action required: 705 - Other - as specified
Due 25 June 2006
Resolved 21 June 2006
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (hydraulic)
Issued 25 May 2006
Resolved
Properly replace hydraulic hose line on cargo pump with approved SAE 1942 hose and SAE 1475 fittings in accordance with 46 CFR 32.35-1.
Action required: 705 - Other - as specified
Due 25 June 2006
Resolved 21 June 2006
Engineering › Diesel Engine (auxiliary) › Governor
Issued 25 May 2006
Resolved
Properly adjust generator speed, generator is currently running at 63-64 Hertz, to manufactures guidance, in accordance with 46 CFR 32.35-1.
Action required: 705 - Other - as specified
Due 25 June 2006
Resolved 21 June 2006
Engineering › Fuel Oil Service System › Filter
Issued 25 May 2006
Resolved
Properly install metal catchment bowl under fuel filter for thermal fluid heater.
Action required: 705 - Other - as specified
Due 25 June 2006
Resolved 21 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 May 2006
Resolved
Properly wire connections for burner eye on TFH, discovered wire lying in the bilge with a wire nut being used as a connection, in accordance with 46 CFR 111.60.
Action required: 705 - Other - as specified
Due 25 June 2006
Resolved 21 June 2006
Engineering › Generator (propulsion/auxiliary-electric) › Ground Detection Equipment Circuitry
Issued 5 August 2005
Resolved
Install ground detection on generator in accordance with 46 CFR 111.05-21 no later than 22 Aug 2005 to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 25 August 2005
Resolution: Ground detection installed.
Engineering › Fuel Oil Service System › Hose
Issued 19 May 2005
Resolved
Prove fuel oil supply and return hoses for the cargo pump engine, generator set and thermal fluid heater meet SAE J1942 for the intended service.
Due 19 June 2005
Resolved 22 July 2005
Deck/Cargo › Cargo Heating › General
Issued 19 May 2005
Resolved
Operation of the Generator set and thermal fluid heater is not authorized. Inspection and testing of generator set and thermal fluid heater must be conducted to the satisfaction of the attnding Coast Guard marine inspector, prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2005
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 19 May 2005
Resolved
Clean deck area under cargo pump engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2005
Construction/Loadline › Structures › Rake
Issued 17 December 2004
Resolved
Effect proper repair to hole in stbd bow box at the 1.5 draft mark hole is 2 in wide by 8 in long. Work is to be completes prior to cargo onload to the satisfation of an attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 December 2004
Resolution: Witnessed satisfactory air test of fracture on bow wrapper.
[name withheld]
Stability › Watertight Integrity › General
Issued 22 July 2004
Resolved
Ensure all wing tank hatch covers seal watertight.
Action required: 705 - Other - as specified
Due 20 August 2004
Resolved 23 July 2004
Construction/Loadline › Structures
Issued 5 March 2003
Resolved
COMPLETE CARGO TANK INTERNAL EXAM AND INTERNAL STRUCTURAL EXAM PRIOR TO ANY CARGO OPS AND BY 05JUN03 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Action required: 705 - Other - as specified
Due 5 June 2003
Resolved 28 January 2004
Resolution: REVIEWING PAST CASES MSO CHICAGO [name withheld] AND CTIE ON 17MAR03. CLEARED THIS 835 AND TRANSFERRED CONTROL OF BARGE TO MSO CHICAGO.
Construction/Loadline
Issued 16 October 2000
Resolved
See MINS for details.
Condition: Unknown
Due 16 November 2000
Resolved 24 October 2000
Deck/Cargo
Issued 22 March 2000
Resolved
MAKE PERMANENT REPAIRS TO THE DECK AREA UNDER THE PORT STERN CONTAINMENT AND THE #4 STBD CARGO TANK EXPANSION DOME.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Deck/Cargo
Issued 16 April 1999
Resolved
DEWATER AND GAS FREE VOID SPACES FOR INSPECTION. DETERMINE CAUSE OF PRODUCTIN THE VOIDS, MAKE REPAIRS AND CLEAN OIL PRODUCT FROM THE VOIDS PRIOR TO LOADING ANY CARGO, TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 16 April 1999
Resolved 16 April 1999
Construction/Loadline
Issued 16 April 1999
Resolved
MAKE WATERTIGHT ONE THRU FIVE PORT AND STBD VOID WATERTIGHT SCUTTLES PRIOR TO CONDUCTING CARGO OPERATIONS, TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 16 April 1999
Resolved 16 April 1999
Deck/Cargo
Issued 22 August 1996
Resolved
UPON DISCHARGE AND PRIOR TO LOADING, MAKE PERMANENT REPAIRS TO NO. 1,2,&3 CARGO TANK GOOSENECK VENT PIPES.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Construction/Loadline
Issued 22 August 1996
Resolved
DETERMINE SOURCE AND MAKE REPAIRS TO LEAK IN NO. 3 STARBOARD VOID.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Construction/Loadline
Issued 30 July 1993
Resolved
MAKE REPAIRS IN WAY OF 24" FRACTURE THAT IS LOCATED ON THE PORT BOW/SIDE WRAPPER PLATE. REPAIRS TO BE MADE PRIOR TO CARGO OPERATIONS.
Condition: Unknown
Due 31 August 1993
Resolved 9 August 1993
Deck/Cargo
Issued 15 October 1992
Resolved
COMPLETE REPAIRS AS DETAILED IN AMENDED ASHLAND OIL WORKLIST DATED_x001C_ 08/31/92 IN WAY OF THE #2 AND #7 CARGO TANKS.
Condition: Unknown
Due 15 October 1992
Resolved 15 October 1992
Construction/Loadline
Issued 6 September 1990
Resolved
THE UPPER STBD STERN TRANSOM WRAPPER PLATE WAS SET IN AND FRACTURED. A 2' X 2' AREA WAS CROPPED AND RENEWED AND 3 CORNER BRACKETS RENEWED. ALL REPAIRS AND AIR TESTS WERE SATISFACTORY.
Condition: Unknown
Due 6 September 1990
Resolved 6 September 1990
Construction/Loadline
Issued 24 March 1988
Resolved
GAS FREE #5 CARGO TANK AND #3 STARBOARD WING VOID AND PRESENT FOR COAST GUARD INSPECTION TO DETERMINE LOCATION OF LEAK BETWEEN CARGO TANK AND WING VOID. REQUIREMENT TO BE COMPLETED PRIOR TO LOADING OR CARRYING PRODUCT.
Condition: Unknown
Due 24 March 1988
Resolved 24 March 1988
Construction/Loadline
Issued 28 August 1987
Resolved
ENTIRE BOTTOM RENEWED AS ORIGINAL.
Condition: Unknown
Due 28 August 1987
Resolved 28 August 1987
Deck/Cargo
Issued 26 September 1986
Resolved
MAKE PERMANENT REPAIR TO ALL MISSING/BROKEN BUTTERWORTH PLATE BOLTS PRIOR TO LOADING CARGO BUT NOT LATER THAN 31OCT86.
Condition: Unknown
Due 26 September 1986
Resolved 26 September 1986
Construction/Loadline
Issued 26 September 1986
Resolved
MAKE PERMANENT REPAIRS TO 12" HORIZONTAL FRACTURE AT DECK IN WAY OF PORT STERN CORNER WRAPPER AT NEXT GAS FREE AVAILIBILITY BUT NOT LATER THAN 31MAR87.
Condition: Unknown
Due 26 September 1986
Resolved 26 September 1986
Deck/Cargo
Issued 26 September 1986
Resolved
PROVIDE WRITTEN PROOF OF COAST GUARD APPROVAL FOR ALL PRESSURE VACUUM VALVES OR RENEW EXISTING PRESSURE VACUUM VALVES WITH COAST GUARD APPROVED PRESSURE VACUUM VALVES PRIOR TO 31OCT86.
Condition: Unknown
Due 26 September 1986
Resolved 26 September 1986
Deck/Cargo
Issued 30 April 1985
Resolved
REPLACE VALVE WITH THREADED PIPE CAP ON CONDENSATE DISCHARGE LINE IN WAY OF#4 CARGO TANK. THIS PIPE CAP SHALL BE MAINTAINED TO AVOID INADVERTENT DISCHARGE OF PRODUCT THROUGH AN APPARENT LEAK INTO STEAM PIPING SYSTEM.
Condition: Unknown
Due 30 April 1985
Resolved 30 April 1985
Construction/Loadline
Issued 30 June 1984
Resolved
MAKE PERMANENT REPAIRS TO NINE (9) FRACTURES IN WAY OF DECK KNUCKLE.
Condition: Unknown
Due 30 June 1984
Resolved 30 June 1984
Construction/Loadline
Issued 30 June 1984
Resolved
REMOVE TEMPORARY PATCH IN WAY OF LOWER HORIZONTAL CORNER STBD SIDE OF BOW BOX AND MAKE PERMANENT REPAIRS.
Condition: Unknown
Due 30 June 1984
Resolved 30 June 1984
Construction/Loadline
Issued 30 June 1984
Resolved
1 AUTHORIZED VOYAGE HOUSTON, TX.-CATLETTSBURG, KY. CARGO MAY BE CARRIED EN-ROUTE BUT REMOVED UPON ARRIVAL THEN DRYDOCKED & CARGO TANKS INTERNALLY INSP
Condition: Unknown
Due 30 June 1984
Resolved 30 June 1984