MAURY USCG vessel records
← All vessels

NWM 802

Built
1978
Last inspected
3 December 2010
Documentation
Invalid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 3 December 2010
…with no type recorded48
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 26 calendar years (1984–2010)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-41479

Documentation record

Registered dimensions (L × B × D)295.0 ft × 52.5 ft × 12.0 ft
Registered tonnagegross 1,671 / net 1,671
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderASHLAND CITY, TN, UNITED STATES · built 1978
Hull materialSteel
PropulsionNone
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNot recorded
Endorsements, as the file codes themNot recorded
DocumentationInvalid
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1671 - Regulatory (Subpart C or D), Net Ton
1671 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 91 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 4 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest. Towing vessels are barely present in the record before 1992, so tow-unit membership for activities older than that is recorded only partially.

NL 267 Freight Barge · MISLE 123163 · 25 May 1999 · activity 158568MICHELLE ANN Towing Vessel · MISLE 198294 · 25 May 1999 · activity 158568EMC 407 Tank Barge · MISLE 40577 · 17 November 1991 · activity 147650TEMPLE HUCKABEE Towing Vessel · MISLE 112619 · 17 November 1991 · activity 147650

Inspection history · 91

3 December 2010 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3903750
19 August 2010 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3828209
5 August 2010 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3826514
19 June 2008 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3242306
15 June 2007 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2967211
17 May 2006 Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2651626
10 April 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2621054
4 August 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2451245
27 June 2005 COI Inspection · Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2405475
28 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2321092
18 March 2005 MTSA Verification
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2319541
10 November 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2238639
23 July 2004 Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2142854
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1984126
15 July 2003 Periodic Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1847055
26 August 2002 Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1666426
24 October 2001 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 772200
29 September 2000 Hull Examination · COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1369845
14 June 2000 Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1050811
1 July 1999 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1434897
3 June 1999 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 806076
25 May 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 158568
25 May 1999 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 800985
28 December 1998 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 756628
21 December 1998 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 190633
2 June 1998 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 793067
3 February 1998 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 642183
20 January 1998 Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1114718
21 December 1997 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 85799
21 December 1997 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 216040
8 July 1997 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1407926
17 January 1997 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 702167
2 January 1997 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 761115
30 December 1996 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 190620
30 December 1996 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 203772
30 December 1996 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 761113
21 October 1996 Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1164067
22 August 1996 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1250375
19 June 1996 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 496388
7 April 1996 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 523586
2 August 1995 COI Inspection · Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1380231
9 December 1994 Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 833863
7 July 1994 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 872720
1 June 1994 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 861161
22 October 1993 Type not recorded
No type recorded · DISTRICT 2 (M) · Activity 642151
16 October 1993 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 535622
8 September 1993 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 475054
5 August 1993 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 642140
17 July 1993 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 174942
7 May 1993 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1134716
13 October 1992 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 456729
8 August 1992 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 501810
1 July 1992 Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1256963
27 March 1992 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1267996
17 November 1991 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 147650
12 November 1991 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 449206
21 August 1991 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 642107
14 August 1991 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1247090
11 July 1991 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1247334
21 June 1991 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 497099
8 June 1991 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 934876
28 March 1991 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 899828
28 March 1991 Examination of Repairs · Damage Survey · COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1211313
17 December 1990 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 468425
5 July 1990 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 460260
26 June 1990 Hull Examination · Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 902692
12 December 1989 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 443200
15 June 1989 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 456505
20 March 1989 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 967568
26 January 1989 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 328175
22 November 1988 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1204636
14 October 1988 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 473232
14 October 1988 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 888996
5 April 1988 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 993417
24 February 1988 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 469907
11 August 1987 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1029734
6 August 1987 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1028018
15 June 1987 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 447182
24 April 1987 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1013063
23 February 1987 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 444902
27 October 1986 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1325876
16 October 1986 Damage Survey
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1317974
25 September 1986 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 518749
17 June 1986 Type not recorded
No type recorded · MSO CINCINNATI · Activity 513774
14 May 1986 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 513786
8 May 1986 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 986366
15 October 1985 Type not recorded
No type recorded · MSO CINCINNATI · Activity 460057
19 May 1985 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 527387
29 April 1985 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1289449
20 November 1984 Type not recorded
No type recorded · MSO CINCINNATI · Activity 505390
19 July 1984 Type not recorded
No type recorded · MSO CINCINNATI · Activity 539320

Deficiency record · 9

Operations/Management › Other Criminal/Civil Violations › Negligent Operations
Issued 22 February 2011 No resolution recorded
Barge has submitted the COI and need to have barge gas free to complete the inactive laid up status.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 March 2011 — due date passed with no resolution recorded
Construction/Loadline
Issued 25 May 1999 Resolved
MAKE PERMANANT REPAIRS TO 3'X1' GASH IN BOW RAKE HEADLOG.
Condition: Unknown
Due 1 June 1999
Resolved 15 June 1999
Construction/Loadline
Issued 8 June 1991 Resolved
CLEAN PORTSIDE HULL FORWARD OF THE THERMAL-FLUID HEATER WHERE FLUID RAN DOWN THE SIDE AS NECESSARY TO PREVENT FURTHER WATER POLLUTION PRIOR TO RELOADING THE VESSEL, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 8 June 1991
Resolved 8 June 1991
Deck/Cargo
Issued 8 June 1991 Resolved
THERMAL-FLUID HEATER PUMP LEAKS FLUID BY THE SHAFT SEAL, REPAIR AS NECESSARY TO PREVENT LEAKAGE PRIOR TO USE OF THE THERMAL-FLUID HEATER, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 8 June 1991
Resolved 8 June 1991
Deck/Cargo
Issued 14 October 1988 Resolved
REPAIR/REPLACE THE ULLAGE OPENING FLAME SCEENS ON #2 AND #3 CARGO TANKS PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 14 October 1988
Resolved 14 October 1988
Deck/Cargo
Issued 6 August 1987 Resolved
MAKE PERMANENT REPAIRS TO THE CARGO PUMP PRIOR TO THE NEXT OFFLOADING OF CARGO.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Deck/Cargo
Issued 24 April 1987 Resolved
MAKE BARGE AVAILABLE FOR THERMAL FLUID HEATER INTERNAL INSPECTION PRIOR TO LOADING CARGO BUT NOT LATER THAN 30 MAY 1987.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Construction/Loadline
Issued 16 October 1986 Resolved
PERMANENTLY REPAIR 5' HORIZONTAL SIDESHELL FRACTURE (AT 5' DRAFT) IN WAY OF#1 STBD AND #2 STBD WING VOIDS AND RENEW ASSOCIATED INTERNAL MEMBERS IN ACCORDANCE WITH GOOD MARINE PRACTICE, PRIOR TO LOADING CARGO BUT NOT LATER THAN 30OCT86.
Condition: Unknown
Due 16 October 1986
Resolved 16 October 1986
Deck/Cargo
Issued 16 October 1986 Resolved
PROVE CARGOTIGHT INTEGRITY OF #1 STBD AND #2 STBD CARGO TANKS IN WAY OF #1 STBD AND #2 STBD WING VOIDS PRIOR TO LOADING CARGO BUT NOT LATER THAN 30OCT86.
Condition: Unknown
Due 16 October 1986
Resolved 16 October 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.