Records from 1995 to 1996. Most recent: operational control imposed, 3 September 1996.
Inspection history · 11
3 September 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 395002
30 September 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 62015
22 August 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 35172
22 August 1995
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421009
19 August 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 3076
15 August 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 35022
23 June 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 138667
11 May 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 378053
3 May 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 377802
21 April 1995
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 463512
21 April 1995
Tank Vessel Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 875587
Accommodation/Occupational Safety
Issued 3 September 1996
Resolved
RENEW AS ORIGINAL THE DETERIORATED GREY WATER PIPING LOCATED ON THE STBD SIDE, LOWER LEVEL OF ENGINE ROOM BETWEEN THE SEWAGE TANKS ABOVE THE GREY WATER OVERBOARD VALVE._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Fire Fighting
Issued 3 September 1996
Resolved
INSTALL A MACHINERY GUARD ON THE EMERGENCY DIESEL FIRE PUMP._x001C_ SEE ILO-147
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Fire Fighting
Issued 3 September 1996
Resolved
UPDATE FIRE CONTROL PLAN TO INCLUDE "A" AND "B" CLASS DIVISIONS, VENTILATION SYSTEMS AND REMOTE SHUTDOWNS._x001C_ SEE SOLAS 74 AMENDED II-2/20
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Documentation
Issued 3 September 1996
Resolved
UPDATE THE VESSELS SOPEP TO REFLECT THE REMOVAL OF THE INERT GAS SYSTEM_x001C_ SEE MARPOL 73/78 ANNEX 1 R.20 AND 33 CFR 151.25
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Documentation
Issued 3 September 1996
Resolved
AMMEND OIL TRANSFER PROCEDURES TO ACCOUNT FOR DISCONNECTION OF INERT GAS SYSTEM._x001C_ SEE 33 CFR 155.720
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Accommodation/Occupational Safety
Issued 3 September 1996
Resolved
RENEW AS ORIGINAL THE DETERIORATED HIGH SEA CHEST PIPING LOCATED ON THE PORT SIDE LOWER LEVEL OF THE ENGINE ROOM INBOARD OF THE MAIN CONDENSOR BELOW THE DECK PLATES. SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Fire Fighting
Issued 3 September 1996
Resolved
RENEW AS ORIGINAL THE DETERIORATED FIREMAIN PIPING IN THE FOLLOWING LOCATIONS: STBD SIDE MAIN DECK ABOVE #1 CENTER CARGO TANK, ABOVE #3 CARGO TANK(FWD), ABOVE #3 CARGO TANK(AFT), ABOVE #4 CARGO TANK(FWD), ABOVE #4 CARGO TANK(AFT), FWD AFT CARGO ROOM BLKHD. SEE SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Documentation
Issued 3 September 1996
Resolved
PROVIDE ONBOARD AN APPROVED VESSEL RESPONSE PLAN._x001C_
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Navigation
Issued 21 April 1995
Resolved
PROVIDE COMPLETE MANEUVERING INFORMATION IN ACCORDANCE WITH 33CFR164.35(g)
Condition: Unknown
Due 21 October 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 21 April 1995
Resolved
REPAIR THE RUDDER ANGLE INDICATOR IN WHEELHOUSE. IAW 33CFR164.35(f).
Condition: Unknown
Due 21 October 1995
Resolved 5 June 1995